Supply Installation Testing Commissioning Of Addressable Fire Detection And Alarm System In Iaf Nfs Site At Kerseong , ( Priority-Ii , Package-Ii ) In West Bengal, Kerseong, Darjeeling-West Bengal

Bharat Sanchar Nigam Limited-BSNL has published Supply Installation Testing Commissioning Of Addressable Fire Detection And Alarm System In Iaf Nfs Site At Kerseong , ( Priority-Ii , Package-Ii ) In West Bengal. Submission Date for this Tender is 09-12-2020. Fire Alarm Systems Tenders in Kerseong, Darjeeling West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26121725
Corrigendum : Supply Installation Testing Commissioning Of Addressable Fire Detection And Alarm System In Iaf Nfs Site At Kerseong , ( Priority-Ii , Package-Ii ) In West Bengal
Open Tender
Indian
West Bengal
Kerseong, Darjeeling
09-12-2020

Tender Details

Supply Installation Testing Commissioning Of Addressable Fire Detection And Alarm System In Iaf Nfs Site At Kerseong , ( Priority-Ii , Package-Ii ) In West Bengal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Dec-2020 SITC of addressable fire detection and alarm system in IAF NFS site at Kerseong, (Priority-II, Package-II) in West Bengal. Technical Bid 09-12-2020

Key Value

Document Fees
INR 590 /-
EMD
INR 8127.0 /-
Tender Value
INR 4.06 Lakhs /-

BOQ Items

Name of work:- SITC of addressable fire detection and alarm system in IAF NFS site at Kerseong, (Priority-II, Package-II) in West Bengal
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Main Fire Alarm Control Panel : SITC of Analogue addressable UL/FM/EN54/VDS Listed Micro Processor controlled, Standalone Main Fire Alarm Control Panel having 1 loop (1 Loop Card) (with minimum 126 devices capacity per loop card) capable of being networked to the central monitoring System to monitor and integrate with Access Control Panel, Detectors, LCP's, hooters, control modules, monitor modules Fault Isolation Modules, response indicators, fire/fault indicators, audio-visual signals, central processing units, complete with coloured TFT display, indicating LEDs, having multiple access levels, event history file in non-volatile memory (EEPROM) and colour screen as per the detailed specification, complete with PSU, Battery backup along with charger for 24 hours in non-alarm condition and 30 minutes in alarm condition etc. as required for each panel. item1 1 No
2 1.02 Addressable Multisensor Detector: Supply, Installation, Testing and Commissioning of Addressable Analogue MULTISENSOR / MULTICRITERIA type, UL/FM/EN54/VDS Listed photo cum thermal detectors (for smoke as well as heat) with solid state design, in-built fault isolator, indicating LEDs, single LED which covers 360º, mounting base, mounting bracket, base box, loop in & loop out gland as per requirement and detailed specifications attached. (Note :- Date of manufacturing of Detectors shall not be more than 6 months at time of supply also Make of Detectors and its base should be same) item2 38 No
3 1.03 Addressable control modules: \nSupply Installation Testing and Commissioning of UL/FM/EN54/VDS Listed, Addressable control module with in-built fault isolator complete with junction box etc. for control options for Hooters & for other control options like PA evacuation, Package AC trip etc.and hooters in case of emergency, etc., complete as required. item3 3 No
4 1.04 Fault Isolator Module: Supply Installation Testing and Commissioning of UL/FM/EN54/VDS Listed Fault isolation module to electrically isolate different sections of detector loops (for every 20 detectors/devices) as per detailed specifications.etc complete as required. item4 2 No
5 1.05 Addressable Manual Call Point: \nSupply Installation Testing and Commissioning of UL/FM/EN54/VDS Listed addressable Manual call points with built-in fault isolator & NO/NC contacts slim type with Pull type/break glass with Reset Lock & Key arrangement suitable for addressable function, etc., complete as required. item5 5 No
6 1.06 Addressable Electronic Hooter Cum Strobe: \nSupply Installation Testing and Commissioning of UL/FM/EN54/VDS Listed addressable Hooter/sounder cum strobe having three distinct sounds with addressable relay module and strobe light with minimum 85 db from 1Mtr distance, with built-in fault isolator, etc., complete as required. item6 2 No
7 1.07 Response Indicators:\nSupply, Installation, Testing and Commissioning of Response Indicator having twin LEDs for mounting on false ceiling/wall/ at the entries of the cabin for indicating the operation of detectors in the above false ceiling/below false flooring detectors, etc., as required. item7 24 No
8 1.08 Exit Signage :\nSupply Installation Testing and Commissioning of LED Emergency Exit signage with 3 hour battery backup etc. as required. item8 3 No
9 1.09 Copper Cable:\nSupplying and laying 2X1.5sq. mm. FRLS PVC insulated PVC sheathed armoured single/multi strand copper conductor cable on surface as required. item9 250 No
10 1.1 CO2 Fire Extinguishers:\nSupplying and fixing wall mounted CO2 type fire extinguisher of 4.5 kg capacity complete with Valve Bend with ABS horn, handle, wall Fixing bracket, discharge hose and including initial charge as required confirming to IS : 2878. (both body and valve shall be ISI marked) item10 4 No