Special Repair Of Building No . P-19 ( Jco Md Accn ) In Sect A Of 2 Mtn Div Signal Regt At Dinjan Mil Stn Under Ge Dinjan

Tender Notice

26118916
Corrigendum : Special Repair Of Building No . P-19 ( Jco Md Accn ) In Sect A Of 2 Mtn Div Signal Regt At Dinjan Mil Stn Under Ge Dinjan
Indian
Assam
30-12-2020
01-01-2021
02-01-2021

Tender Details

Special Repair Of Building No . P-19 ( Jco Md Accn ) In Sect A Of 2 Mtn Div Signal Regt At Dinjan Mil Stn Under Ge Dinjan

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-202 83052AmendmentI Date 23-12-2020
2 12-Dec-202 83052AmendmentII BOQ 23-12-2020
3 23-Dec-202 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-12-2020
4 30-Dec-202 DRT EXTENDED-2 Date 01-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 74800.00 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIR OF BULDING NO. P-19 (JCO MD ACCN) IN SECT ‘A’ OF 2 MTN DIV SIGNAL REGT AT DINJAN MIL STN UNDER GE DINJAN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed. 21022A 18 Sqm
2 2 S & F 1.00 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. 10029C 18 Sqm
3 3 M & L for plain, galvanised, mild steel sheeting with grade of zinc coating 275, 0.80 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed. 11012B 20 Sqm
4 4 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exceeding 10 kg each brackets (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed. 10010A 62 Kg
5 5 Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified. 21042B 120 sqm
6 6 Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position 21020A 0.55 Cum
7 7 Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge. 10094A 120 Sqm
8 8 M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture as approved of Make Armstrong/Everest/ Ramco, fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified as by the Engineer-in-Charge. 12021M 120 Sqm
9 9 Preparation of newly plastered surfaces/boards on ceilings and applying three coats of white wash complete all as specified and as directed. 15007C 170 Sqm
10 10 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 18059A 100 Running Metre
11 11 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 18059B 65 Running Metre
12 12 Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 18047A 62 Running Metre
13 13 Fixing only to walls and ceilings or laid in floors 15 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 18051A 38 Running Metre
14 14 Supplying & laying in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 18047B 55 Running Metre
15 15 Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. 18060B 10 Running Metre
16 16 Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., exceeding 10 cm but not exceeding 20 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. 05046A 48 Running Metre
17 17 Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed. 18080B 8 Each
18 18 S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. 18082B 8 Each
19 19 S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete 18104B 8 Each
20 20 S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed. 18105B 8 Each
21 21 Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed. 14041A 580 Sqm
22 22 Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. 14005E 310 Sqm
23 23 Material and labour for plastering 10 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed. 14002O 190 Sqm
24 24 Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and fair complete all as specified and as directed. 14001G 50 Sqm
25 25 M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed 15009A 310 Sqm
26 26 Complete removal of existing treatment of wall and M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer over putty to match the surfaces complete all as specified and as directed 15009B 480 Sqm
27 27 Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed. 15007D 280 Sqm
28 28 M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. 15022A 190 Sqm
29 29 M & L for complete removal of existing finish on walls including chajjas, facias etc and applying two coat of weather proof acrylic exterior paint (100% Acrylic)over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. 15022C 250 Sqm
30 30 Preparation of old decorated surfaces on walls and applying one coat of white wash complete all as specified and as directed. 15006D 25 Sqm
31 31 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed 08069D 88 Each
32 32 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed 08072D 75 Each
33 33 S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed. 10082B 130 Running Metre
34 34 S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile B, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed. 10082A 165 Running Metre
35 35 S & F solid PVC wall lining consisting of 3 mm thick coloured PVC sheet inclusive of solvent cement and preparing existing surface and fixing at site on as cupboard etc. as specified and directed 08113C 82 Sqm
36 36 M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge. 04029C 4.1 Cum
37 37 Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed. 08075D 16 Each
38 38 S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (multi panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated. 08015K 95 Sqm
39 39 S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (one panel) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated. 08021A 65 Sqm
40 40 M & L for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed. 10090A 105 Sqm
41 41 Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick single side prelam PVC sheet and edge will be printed to match with prelam sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge. 08097A 80 Running Metre
42 42 S & F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with particle board core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. 08101A 25 Sqm
43 43 S & F aluminium anodised sections, minimum anodic coating of grade AC 15 for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified. \r\nNote : (i) Glass panes, wire mesh & handle will be measured & paid separately . \r\n(ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately.\r\n(iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. 10089E 760 Kg
44 44 S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. 09158A 30 Sqm
45 45 S & F butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 150A22 as per IS 205: 1992 complete all as specified and as directed. 09052A 198 Each
46 46 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 09004E 32 Each
47 47 S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 09083C 32 Each
48 48 S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 09083D 96 Each
49 49 S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 09019D 56 Each
50 50 S & F prelaminated particle board (decorative lamination on both sides), 20 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWP adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in table tops, counter, furniture tops, etc. complete all as specified and as directed. 12049D 50 Sqm
51 51 Preparation of previously primed steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge 17029E 40 Sqm
52 52 M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 17001F 150 Sqm
53 53 M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 17001G 12 Sqm
54 54 S & F 50 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 09028C 48 Each
55 55 S & F timber species of group I for frames and durability class I as per IS 12896: 1990 for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like articles not exceeding 200 cucm each complete all as specified and as directed. 08061B 48 Each
56 56 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge. 21004A 2 Cum
57 57 M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. 05004H 2 Cum
58 58 Demolition of lime concrete of any description and in any position not otherwise specifically provided for 21017A 10 Cum
59 59 M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed 04033A 1.1 Cum
60 60 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. 10034F 65 Kg
61 61 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and smooth using extra cement complete all as specified and directed. 13036D 30 Sqm
62 62 Supply & fix glass dividing strip 38 mm wide and 3 mm thick complete all as specified and as directed. 13062C 15 Running Metre
63 63 M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed. 13034B 40 Sqm
64 64 M & L for forming 12 mm thick expansion joints in 100 mm thick slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed. 20079A 5 10 Running Metre
65 65 M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed. 13049A 180 Sqm
66 66 M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified & directed by Engineer-in-Charge. 13050A 180 Sqm
67 67 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 13109A 500 Sqm
68 68 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. 13037A 260 Sqm
69 69 M & L for non skid, rectified, colour ceramic floor tiles (group B II), 300 mm X 300 mm X 7 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed. 13082B 35 Sqm
70 70 M & L for glazed, colour ceramic wall tiles (group B III), 300 mm X 200 mm X 7 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed. 13080B 200 Sqm
71 71 M & L for non skid, rectified, colour ceramic floor tiles (group B II), 400 mm X 400 mm X 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed. 13083B 300 Sqm
72 72 M & L for non skid, rectified, colour ceramic floor tiles (group B II), 400 mm X 400 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed. 13083D 25 Sqm
73 73 M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 13013C 35 Sqm
74 74 M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed. 13015C 6 Sqm
75 75 Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc. 21009B 0.7 10 Sqm
76 76 M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade including 20 mm thick screed in cement mortar 1:4 including grinding and polishing complete all as specified and as directed. 13022A 8 Sqm
77 77 S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. 18248H 2 Each
78 78 S & F in repairs PVC low/high level flushing cistern white 10 liters capacity including PVC inlet pipe with brass check nuts low level full both sides along with PVC flush pipe 32 mm dia jointed to WC and handle including brackets fixed in repairs all as specified and as directed. Note:- Rate includes removing existing flushing system of CI or any other quality including brackets. 18266A 2 Each
79 79 S & F vitreous china semi pedestal pattern(Anglo-Indian Type), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. 18247C 6 Each
80 80 S & F in repairs health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed by Engineer-in-Charge. 18357B 6 Each
81 81 S & F in repairs in repairs thermoplastic seats and covers of grade 2 type, recessed with hinging device of bronze or brass with nickel chromium plating complete all as specified and as directed. 18327B 6 Each
82 82 S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. 18316A 8 Each
83 83 Providing and fixing galvanised steel holder bat clamps of approved design to 100 mm dia/ bore rain water pipe/ soil waste pipe embedded in and including cement concrete blocks 100 mm X 100 mm X 100 mm of Nominal Mix (M15) using 20 mm nominal size graded crushed stone aggregate and cost of cutting holes and making good at any floor complete all as specified and as directed. 18169C 24 Each
84 84 Dismantling of cast iron or reinforced concrete drain pipes of size 100 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. 21054A 45 Running Metre
85 85 S & F grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed. 18136A 24 Each
86 86 S & F in repairs swivel shower of PTMT any colour for fixing with 15 mm pipe. minimum weight 40 gms complete all as specified and as directed. 18142B 8 Each
87 87 S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. 18269M 8 Each
88 88 S & F 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed. 18132A 8 Each
89 89 S & F pillar taps of PTMT, any colour, high pressure, minimum weight 100 grams, screwed for steel tube for nominal size 15 mm complete all as specified and as directed. 18123A 8 Each
90 90 S & F 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 18337A 8 Each
91 91 S & F in repairs bib tap standard of PTMT, any colour, high pressure, minimum weight 90 grams, screwed for steel tube for nominal size 15 mm complete all as specified and as directed. 18119F 40 Each
92 92 S & F in repairs stop valves of PTMT, any colour, high pressure, minimum weight 90 grams, screwed for steel tube for nominal size 15 mm complete all as specified and as directed. 18125F 16 Each
93 93 S & F angle stop valve of PTMT, any colour, high pressure, minimum weight 90 grams, screwed for steel tube for nominal size 15 mm complete all as specified and as directed. 18127A 8 Each
94 94 M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 18150C 16 Each
95 95 S & F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastics cleats, minimum weight 190 gms complete all as specified and as directed. 18148A 8 Each
96 96 M & L for precast cement concrete louvers and jallies, 25 mm thick (measured solid) in cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate including all mouldings but excluding frame and fixed in position using cement mortar (1:4) complete all as specified and as directed. 04034A 15 Sqm
97 97 Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge. 18214C 8 Each
98 98 S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge. 18181A 10 Running Metre
99 99 S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge. 18183A 24 Running Metre
100 100 S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. 18185A 8 Each
101 101 S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge. 18181B 20 Running Metre
102 102 S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge. 18183B 50 Running Metre
103 103 S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. 18185F 4 Each
104 104 S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. 18185B 8 Each
105 105 S & F UPVC Tee(87.5°) single, 110 mm dia with inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. 18188F 8 Each
106 106 S & F in repairs sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 18277B 8 Each
107 107 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 32 mm including all fittings and fixtures in trenches complete all as specified and as directed. 18065D 8 Running Metre
108 108 S & F in repairs to replace old and or decayed boarding fixed in roofs, ceilings, partitions, fascia, barge, soffit, etc. (except flooring and skirting) in patches including cutting out old, piecing, heading joints etc., structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn with butt joints in boarding, 15 mm thick fixed with nails in any situation complete all as specified and as directed. 07045K 32 Sqm
109 109 S & F 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 18103A 8 Each
110 110 S & F in repairs 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed. 09143C 120 Running Metre
111 111 M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed. 13102C 35 Sqm
112 112 M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 04041B 1.2 Cum
113 113 M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed. 07010A 17 Sqm
114 114 Demolition of cement concrete(unreinforced) above ground floors exceeding 15 cm thickness (below or above ground level) 21016B 2.5 Cum
115 115 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. 14001N 25 Sqm
116 116 Supply only integral water proofing compound. 04099A 12 Kg
117 117 M&L for applying two coats of water proofing coating by using super latest manufactured by pidilite industries limited (or equivalent product manufactured by Sika/fosroc/choksey chemical), water and cement ratio 1:4:7 or the ratio as instructed by manufacture on sunken floor and wall complete all as specified and as directed. 71030C 25 Sqm
118 118 S & F Kitchen stainless steel plate rack of size 31" X 30" X 10" as per catalogue No. P-346 of Prayag or equivalent of Make mentioned under Appendix ‘B’ to Particular Specification including necessary fixing / fittings & making good the existing surfaces complete all as specified and directed. 18478K 8 Each
119 119 Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clean and washing down complete all as specified and as directed. 11153B 130 Sqm
120 120 Material & labour for rendering 20 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction finished even and fair complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only) 11155B 130 Sqm
121 121 M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/ sqm ± 5 % per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc. and including applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed. 11154A 130 Sqm
122 122 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 40 mm thick as levelling course of roof padding complete all as specified and as directed. 13037E 2.5 Cum
123 123 M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. 05011I 22 Sqm
124 124 Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings. 21033B 80 Sqm
125 125 S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. 10046A 200 Kg
126 126 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 11017A 80 Sqm
127 127 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 11018A 20 Sqm
128 128 Material, T&P and labour for cleaning of sewage line of any dia/bore using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed. 18491B 20 Running Metre
129 129 Material, T&P and labour for cleaning of manholes using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed. 18492D 20 Each Job
130 130 Material, T&P and labour for cleaning of blockage of WC, wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying soil waste) in any length upto the first manhole using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed. 18492C 4 Each Job
131 131 Material, T&P and labour for cleaning/ desludging of septic tank/ soak well of capacity from 200 users to 201 users using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land complete all as specified and as directed. 18493E 4 Each Job
132 132 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 19303A 216 Point
133 133 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be measured and paid separately.) 19305K 136 Point
134 134 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19313C 32 Point
135 135 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19326A 24 Point
136 136 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19314C 24 Point
137 137 S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 19386A 160 Each
138 138 S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 19415A 32 Each
139 139 S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 19419A 40 Each
140 140 S & F switch socket combination with (3 pin and 3 pin) having two earthing pins combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and indicator and fuse complete all as specified and as directed. 19421A 24 Each
141 141 S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 19469A 88 Each
142 142 S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed. 19505A 24 Each
143 143 S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 19394A 8 Each
144 144 S & F call bell suitable for single phase, AC, 240 volts complete all as specified and as directed. 19397A 8 Each
145 145 S & F LED tube light nominal power 18 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1800, lumen efficacy of minimum 100 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, CRI greater than 80%, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.90 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No. LHLDCLXNUJ7Z018 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed. 19918M 44 Each
146 146 S & F batten including tube light 10W, Polycarbonate co-extrusion tube housing, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 140 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1000, lumen efficacy of minimum 100 lumens per watt, low loss constant current driver (>85% efficiencies with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, THD less than 20%, CW available CCT of 5700K, power factor of minimum 0.95, life span of minimum 50000 working hours as per Product Code 112407, catalogue reference BCLSB 10 WH of Bajaj or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed. 19915D 16 Each
147 147 Taking down existing old fluorescent tube light fittings/ bulk head light fittings/ ceiling light fittings/ building light fittings including lamp any capacity, any type complete all as specified and as directed. 19801X 56 Each
148 148 S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. 19385A 40 Each
149 149 S & F LED Bulb/ lamp non-dimmable type 10 watts with high power LEDs as light source and electronic driver complete all as specified and as directed. 19601E 40 Each
150 150 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 19455O 9 Each
151 151 S & F circuit breakers (MCB), Double pole (DP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 19445N 8 Each
152 152 S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 19445J 60 Each
153 153 S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 19456D 1 Each
154 154 S & F circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 19449M 1 Each
155 155 Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed. 19507I 160 Running Metre
156 156 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. \nNote - Two runs of 6 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. 19510C 160 Running Metre
157 157 S & F LED street light/ building security light nominal power 25 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, lumen output of minimum 4500, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. ENDURAPEARLSL25WLED757SASYTOPC of Havells or equivalent of Make mentioned under Appendix "B" including 1.5 metre medium grade galvanized iron pipe bracket made of suitable nominal bore and necessary nuts, bolts, clamps including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. 19915L 4 Each
158 158 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. 19471A 2 Each
159 159 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 03006A 11.6 Cum
160 160 Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point 03029A 4.1 Cum
161 161 M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. 03019A 3.4 Cum
162 162 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 03009A 7.5 Cum
163 163 M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed. 19216C 340 Each
164 164 Supplying & laying in trenches 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 18046F 6 Running Metre
165 165 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 19244C 50 Running Metre
Disclaimer :