Development And Upgradation Of Agatti Airport Sh Construction Of Terminal Building Atc Tower Cum Technical Block Dvor Building At Kalpatti Island With Construction Of Associate Buildings And Allied Works Including Operation And Aicmc At Agatti

Tender Notice

26103615
Corrigendum : Development And Upgradation Of Agatti Airport Sh Construction Of Terminal Building Atc Tower Cum Technical Block Dvor Building At Kalpatti Island With Construction Of Associate Buildings And Allied Works Including Operation And Aicmc At Agatti
Indian
Lakshadweep
01-01-2021
01-02-2021
08-02-2021

Tender Details

Development And Upgradation Of Agatti Airport Sh Construction Of Terminal Building Atc Tower Cum Technical Block Dvor Building At Kalpatti Island With Construction Of Associate Buildings And Allied Works Including Operation And Aicmc At Agatti

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Dec-202 Corrigendum II Other 16-01-2021
2 15-Dec-202 Corrigendum II BOQ BOQ 16-01-2021
3 01-Jan-202 Corrigendum 3 Dates Date 01-02-2021

Key Value

Document Fees
INR 11800 /-
EMD
INR 18600000.00 /-
Tender Value
INR 140.16 Crore /-

Attachment

FileName File Description File Size
Tendernotice_1.pdf Tender Document-NIT 139.78
BOQ_67769.xls Tender Document-BOQ 279.50
VOLUME2.pdf Tender Document-Tender Document II DBR and Specifications 8282.18
VOLUME3.pdf Tender Document-Tender Document Volume III Drawings 32848.75
75977597-1E89-49D7-ACC8-20419D103E69.html Tender Notice-Tender Notice 0
VOLUME1.pdf Tender Document-Tender Document Volume I NIT GCC SCC SOQ 24393.21

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: “Development and Upgradation of Agatti Airport. SH: Construction of Terminal Building, ATC Tower cum Technical Block, DVOR Building at Kalpatti Island with Construction of Associate Buildings and Allied works including Operation and AICMC at Agatti Airport”
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Construction of the Project/Work on the Site set forth in Schedule A and as specified in Schedule-B together with provision of Project Facilities as specified in Schedule-C, and in conformity with the Specifications and Standards set forth in Schedule-D Performance and fulfilment of all other obligations of the Contractor and ensuring compliance to all provisions contained elsewhere in the contract and in accordance with the provisions of this Agreement and matters incidental thereto or necessary for the performance of any or all of the obligations of the Contractor under this Agreement. 1 Job
2 2 Operation & Maintenance and Repair/AICMC BI01010001010000000000000515BI0100001112
3 2.01 Operational and Service Charges for 07 years including Defect liability period of 02 Years (24x7x365 days as specified in tender document) after completion of work. \nNote: Amount to be quoted for First Year only.\nYearly 10% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\nFinal amount for 7 years shall be automatically calculated and will be reflected in total Amount quoted.\n 7 Years
4 2.02 Annual Repair works including Preventive Maintenance for 05 Years after Defect liability period of 02 Years.\nNote: Amount to be quoted for First Year only.\nYearly 7% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\nFinal amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted. BI01010001010000000000000515BI0100001114 5 Years
5 2.03 Providing manpower for Operation of DG sets,Substation equipments, Internal & external electrical installation, HVAC (VRF/VRV), Fire Fighting, Fire alarm System , WTP, STP etc. as per standard OEM recommendations , maintenance schedules & practices as per manpower/ shift schedule mentioned in special conditions of contract.(For 07 years including 02 years of DLP)\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 10% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 05 years shall be automatically calculated and will be reflected in total Amount quoted.\n BI01010001010000000000000515BI0100001115 7 Years
6 2.04 All inclusive Comprehensive Maintenance of sub station equipments including HT/LT panel , DG sets, UPS,SPD etc. and associated system, after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified.For 05 yesrs after DLP of 02 Years\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 05 years shall be automatically calculated and will be reflected in total Amount quoted. BI01010001010000000000000515BI0100001116 5 Years
7 2.05 All inclusive Comprehensive Maintenance of internal and external installations including all associated accessories such as DB,swithches ,socket, wiring ,lighting control system, occupancy sensor ,automatic sliding doors etc. excluding LED fixtures/fittings after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified.For 05 yesrs after DLP of 02 Years\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 05 years shall be automatically calculated and will be reflected in total Amount quoted.\n\n BI01010001010000000000000515BI0100001125 5 Years
8 2.06 All inclusive Comprehensive Maintenance of Lifts and boom barrier after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified for 05 after Defect liability period of 02 Years.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted.\n 5 Years
9 2.07 All inclusive Comprehensive Maintenance of photo voltaic Solar power generation system after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified.Note: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 05 years shall be automatically calculated and will be reflected in total Amount quoted. BI01010001010000000000000515BI0100001119 5 Years
10 2.08 All inclusive Comprehensive Maintenance of HVAC system (VRV/VRF) airconditioning system including ventilation and smoke extractor system etc. and associated system after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified for 05 after Defect liability period of 02 Years.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted. BI01010001010000000000000515BI0100001120 5 Years
11 2.09 All inclusive Comprehensive Maintenance of of water supply system including hydopenumatic system , WTP,RO system, water coolers, hand driers etc after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified for 05 after Defect liability period of 02 Years.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted. BI01010001010000000000000515BI0100001121 5 Years
12 2.1 All inclusive Comprehensive Maintenance of Fire hydrant and sprinkler sytem , Gas Suppression system etc. Fire Alarm and associated system, after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted. BI01010001010000000000000515BI0100001122 5 Years
13 2.11 All inclusive Comprehensive Maintenance of Sewarage Treatment Plant and its associated system etc. after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted. 5 Years
14 2.12 All inclusive Comprehensive Maintenance of PAVA and its associated system etc. after DLP of Two years as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 07% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 5 years shall be automatically calculated and will be reflected in total Amount quoted. 5 Years
15 2.13 AICMC of Airport System Works\nCost of 3 years CAMC is included in constrcution cost ,CAMC is to be done for form 4 year to 7 year.\nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 10% cumulative enhancement on first year cost shall be applicable from fifth Year onwards.\n iii) Final amount for 04 years shall be automatically calculated and will be reflected in total Amount quoted. 4 Years
16 2.14 AICMC Cost of IT Works\nCost of 5years CAMC for ICT is included in construction cost ,CAMC is to be done from 6 year to 7 year. \nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 10% cumulative enhancement on first year cost shall be applicable for Seventh Year.\n iii) Final amount for 02 years shall be automatically calculated and will be reflected in total Amount quoted. 2 Years
17 2.15 Cost of O&M (IT Works) Support Engineer Two ( L1+L3) \nNote: i) Amount to be quoted for First Year only.\n ii) Yearly 10% cumulative enhancement on first year cost shall be applicable from Second Year onwards.\n iii) Final amount for 07 years shall be automatically calculated and will be reflected in total Amount quoted. 7 Years
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail