Provision Of Security Guard Post And Boom Barrier At Cvrde Arch Avadi .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-12-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 16200.0 /-
Tender Value
INR 8.10 Lakhs /-

BOQ Items

NAME OF WORK : Provision of Security guard post and boom barrier at CVDRE Arch Avadi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation of trenches, n.exc 1.5 wide and n.exc 1.5 in depth for fondation etc, or for shafts, well , cesspits, manholes pier holes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil. 21 Cum
2 2 M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete. 0.7 Cum
3 3 Brick work with fly ash bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. 4 Cum
4 4 Use and waste of rough finished surfaces formwork (Flat surface) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter 25 Sqm
5 5 Use and waste of rough finished surfaces formwork (Flat surface) to sides of pillars, posts, struts, piers, columns, and stanchions 12 Sqm
6 6 Use and waste of rough finished surfaces formwork (Flat surface) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. 5 Sqm
7 7 Use and waste of formwork (Flat surface) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with rough finishes of surfaces 20 Sqm
8 8 Use and waste of formwork (Flat surface) to edge of concrete flats, treads, breaks in floors, window cills, concrete railing , opening in concrete wall, floors and roof and side of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for rough finished surfaces. 15 RM
9 9 TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. 525 Kg
10 10 All as per item No. 9 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders 180 Kg
11 11 M&L for RCC 1: 1.5:3 type A1 using 20mm graded aggregate as in Columns, pillars, piers, posts and struts all as specified and as directed. 1 Cum
12 12 M&L for RCC 1: 1.5:3 type A1 using 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as specified and as directed. 1.5 Cum
13 13 M&L for RCC 1: 1.5:3 type A1 using 20mm graded aggregate as in Roof Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and as directed. 0.8 Cum
14 14 M&L for RCC 1: 1.5:3 type A1 using 20mm graded aggregate as for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajja etc and the like all as specified and as directed. 2.5 Cum
15 15 M&L for rendering 10mm thick in CM 1:4 on wall surfaces as in backing coat for wall tiling all as specified and as directed. 1.3 Sqm
16 16 M&L for 5mm thick rendering in CM 1:3 on ceiling of roof slab and finished the surfaces even and smooth without using extra cement all as specified 22 Sqm
17 17 M&L for 15mm thick cement plaster in CM 1:4 in two coats on concrete and brick masonry surface 10mm thick first coat and 05 secoud coat mixed with WPC @ 3% by the weight of cement and finsished the surfaces even and smooth without using extra cement all as specified and directed. 30 Sqm
18 18 M&L for 15 mm thick cement plaster in CM 1:6 on concrete and brick masonry surface and finsished the surfaces even and smooth without using extra cement all as specified and directed. 29 Sqm
19 19 M & L three coat of white wash on new plastered surfaces on ceiling including preparation of new plastered surfaces all as specified and directed. 22 Sqm
20 20 M&L for two coats of exterior acrylic based paint over a coat of primer on new plastered surfaces including preparation of new plastered surfaces all as specified and directed. 30 Sqm
21 21 M&L for two of coats distempering walls with distemper oil emulsion, white or tinted over a coat of primer and 02mm thick wall putty on new plastered surfaces including preparation of new surfaces all as specified and as directed by Engr-in-Charge. 29 Sqm
22 22 Hard core of broken stone gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed. 4.8 Cum
23 23 M&L for coloured Vetrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 all as specifed. 12.8 Sqm
24 24 M&L for coloured Vetrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing plaster in CM 1:4 all as specifed. 1.5 Sqm
25 25 Supply and fixing powder coated aluminium three track sliding window brown/ivory colour made out of extruded aluminium section (using 18mm series of JINDAL) having minimum 50 micron thick coating as mentioned below. Each window having 03 glazed shutters with locking arrangement, Glazed shutter to be glazed with 5.5mm thick tinted coloured glass (colour as approved by engineer-in-Charge) with rubber beading/gasket, anodised aluminium beading, screws, nylon wool pile weather strip, nylon rollers including assembly etc complete all as specified and as directed & approved by Engineer-in-Charge.\nChowkat frame : 31.75x92.00x2.00mm \nShutter vertical stlies 18.00x40.00x 1.95mm\nShutter top rail 18.00x40.00x 1.95mm\nShutter bottom rail 18.00x40.00x 1.95mm\n\n 6 Sqm
26 26 S&F aluminium powder coated deco grill of 10mm thick fixed with 'F' section frame of 2mm thick complete all as specified and directed by Engineer-in-Charge. 6 Sqm
27 27 Supply only integral waterproofing compound. 8 Kg
28 28 Plain cement concrete 1:3:6 type C-1 (20mm graded aggregate), 75mm thick as in plinth protection complete all as specified and directed by Engineer-in-Charge. 15 Sqm
29 29 M & L PCC 1:4:8 type D2 (40mm graded aggregate) 100mm thick as in sub base of floors all as specified and directed by Engineer-in-Charge. 4.8 Sqm
30 30 Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 cum for hard / dense soil complete all as specified and directed. 13 Cum
31 31 Removing excavated material exc 250m and n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point for soil complete all as specified and directed. 8 Cum
32 32 S&F Aluminium powder coated door frame with shutter, single shutter with top panels of tinted glass 5.5mm thick fixed with rubber packing and glazing clips and bittom panel of PVC sheet 5.0mm thick fixed with rubber packing and glazing clips. The door frame shall be jointed with joining cleats and shall be fixed in existing wall with thurst bolt suitable size as all as specified and directed. The door frame and shutter shall be made as under:-\n(a) Aluminium colour coated door frame of section 101 x 44 x 3mm \n(b) Aluminium colour coated bottom rails of shutter section 200 x 44 x 3mm\n(c) Aluminium colour coated top, middle/lock, side rail of shutter section 150x44x3mm.\n(d) Six lever mortice lock brass Make: GODREJ/ARGENT 01 No.\n(e) Aluminium colour coated tower bolt 200mm long 02 Nos each door\n(f) Aluminium colour coated handle 150mm long 2 nos\n(g) Heavy duty double auction door floor spring hudraulically regulated.\n(h) PVC sheet 5.0 mm thick fixed with rubber beading and glazing clips.\n(i) Tinted glass 5.5 mm thick fixed with rubber beading and glazing clips. 2.1 Sqm
33 33 M&L for Chequered cement concrete tiles of size 300mm x 300mm x 25mm thick set and jointed and pointing in neat cement sallary in floors with with white cement and pigment to match colour on 15mm thick screed bed in CM 1:6 all as specified and directed. 2.5 Sqm
34 34 Demolition of cement concrete in any position and of any description all as specified (Note : cutting of edges of concrete shall be done by using dimond cutter machine) 4 Cum
35 35 M&L for granite (of any type) size shall be 2.84 x 0.75mm in single stone, 20mm thick, machine cut, both length edges full bull nosing, as in counter laid over 15mm thick screed bed over RCC Salb all as specified and directed. 2 Sqm
36 36 M&L terracotta decorative colour roof tiles 10mm thick laid on slope roof surfaces with 15mm thick cement mortar 1:4 including 3% WPC all as specified and directed.\nNote: The Colour and design of terracotta shall as approved by AGE (I). 20 Sqm
37 37 Supply, Install, testing and commissioning of boom barrier Eectromechanical drive type 230V, 50Hz micro processor based controller unit, 6 metre long sturdy steel structure beam, scratch proof casting (RAL 2000) powder coated round/bar aluminium boom with reflected stickers,loop detector,safety optical sensor, push button, remote control, flash light, traffic light with pole, mounting accessories, key operated system for manual operation, suitable for outdoor duty and erection as per OEM specfication including copper conductor control cable to optical sensor from control cubile, masonary work, foundation bolts, nuts etc and making good the disturbed surface as existing complete all as specified and as directed. \nMake: Goodrej model GVB6 or its equivalent as approved by accepting officer. 2 Each
38 38 Dry river sand cushioning / sand covering for underground cable protection complete all as specified. Note : Punned down thickness only shall be measured complete all as specifed and directed 4 Cum
39 39 Supply and lay pld size brick of size 230x115x75mm burnt clay building brick sub class B for protection LTUG cable complete all as specifed and directed 434 Each
40 40 Supply and lay XLPE insulated, armoured heavy duty electric cable with\naluminium conductor, 1100 volts grade, cross-sectional area 10sqmm 2core, incl provision of cable glands, termination in panels/DB complete complete all as specifed and directed. 100 RM
41 41 M&L for GI tubes light grade 40mm dia laid under floor/road with fittings, clamps etc for protection of cable complete all as specifed and directed. 15 RM
42 42 M&L for GI tubes light grade 50mm dia fixed on wall/pole with fittings, clamps etc complete all as specifed 18 RM
43 43 Supply and fix LED flood light fittings not less than100W,240V,50Hz, luminus efficiency 100lumes/watt, 5700K made up epoxy powder coated die-cast aluminium housing incl heat sink, toughened glass integrated electronic LED driver with protection circuits and suitable for mounting on pole/surface with including provison of GI bracket / MS clams botls complete all as specifed and directed.\n“Make :- JETAIRISFLS100WLED757APNBLTG of Havells /\nLFLN-100-CDL/60 of CG/\nBJFL 100W LED I of Bajaj” 2 Each
44 44 Supply and fix junction box made of inpact resistance plastic & heat resistant materials of size not less than 140x140x95mm, IP 66 protection, single left hinged door including provision of suitable terminal connector 16A capacity with MCB SP 6A and fixing to the surface/light pole with suitable sizes of clamps, nuts and bolts complete all as specifed and directed. 2 Each
45 45 M&L for cutting of cement concrete road unreinforced floor n.exe 15cm thickness for laying pipe and making good disturbed surface PCC 1:1.5:3 complete all as specified and directed. \nNote : Cutting of road shall be carried out using diamond cutter. 1 Cum
46 46 M&L for GI tubes light grade 15mm dia laid under floor/road with fittings, clamps etc for protection of cable complete all as specifed and directed. 12 RM
47 47 M&L for Point wiring with PVC insulated, FRLS PVC unsheathed, two single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into and including concealed rigid non-metallic PVC conduit not less then 20mm wide, ISI marked with 1.5 Sqmm unsheathed, stranded copper FRLS cable for continuous earth wire and including pressed modular metal concealed terminal boxes of reqd size and suitable size inner frame with outer cover suitable for modular switches/ sockets/regulators all as specified & directed for the following :-
48 48 (a) One light/fan point controlled by one single pole 5A switch 3 Point
49 49 (b) One switch socket out let point 5A on independent board 1 Point
50 50 (c) One switch socket out let point 5A on same board. 1 Point
51 51 Modular switch 6 Amps, single pole,oneway,1 module complete all as specified and as directed 5 Each
52 52 Modular Socket, 6A - 2/3 pin combined 2 module,complete all as specifed and directed. 2 Each
53 53 S&F for modular type fan regulator 120W 2 Module type all as specifed and directed. 1 Each
54 54 Sheet metal enclosure for MCB DB SPN 8 way, 240 Volts, single phase, double door with IP-43 protection with100 Amps rated busbar suitable for DP MCB as incomer and DP/SP MCB as outgoing, flushed on wall surface and wrting letters as DB Title/Incomer/ Outgoing details in paint over DB door complete all as specified and directed. 1 Each
55 55 S&F for ceiling rose surface bakelite size 65x50mm three terminal 230V, 50Hz complete all as all as specifed and directed. 3 Each
56 56 S&F batten 4 feet LED tube light fitting 20W high lumen efficiency, min 5700K and extruded aluminium/polycarbonate/CRCA body with suitable electronic driver, 230V with all accessories pre wired, connecting up with and including twin core twisted flexible copper cable complete inclluding taking down unserviceable FTL fitting any type any watts all as specified and directed. \nMake: Havells Cat No LUMILINEBS20WLED865SPCWH/CG Cat No LCTLN-20-CDL/ WIPRO Cat No LL20-221-XXX-65NE3/PHILIPS Cat No BN021C LED20S PSU CW GR S2 2 Each
57 57 Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, including provision of 4mm dia GI wire as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, provision of 15mm dia GI pipe light grade for protection of GI wire connected from earth plate electrode to main DB, provision of 20mm dia GI pipe medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos x 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc. 50m, provision of charcoal and salt complete all as specified and directed and testing on completion. \nNote: (i) Cost of GI earth lead wire and GI protection pipe upto 7.5m length deemed to be included in the rate quoted.\n(ii) Quoted rate shall deemed to include the cost of excavation and earth work in any type of strata. 1 Each
58 58 Ceiling fan 5 star rated, 1200mm sweep, energy efficient suitable to function on 230Volt, single phase AC supply, complete including regulator and connecting with and including provision of PVC sheathed 3 core 1.5 sqmm flexible copper conductor from ceiling rose to fan connector, complete all as specified and directed.\nMAKE:- Cat No. ES-50 premium of Havells or techno-commercially equivalent model in Uhsa / Crompton greaves\n 1 Each