Military Engineer Services-MES has published Periodical Services To Security /Jaffri Wall And Repairs To Chain Linik Fencing , Barbed Wire Fencing , Footpath , Storm Water Drains In North East Zone At Rms. Submission Date for this Tender is 09-12-2020. Building Repair Tenders in Rangapahar Nagaland. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-Dec-2020 | Due Date Extended | Admin Corrigendum Date Extend | 09-12-2020 |
Name of Work: PERIODICAL SERVICES TO SECURITY /JAFFRI WALL AND REPAIRS TO CHAIN LINIK FENCING, BARBED WIRE FENCING, FOOTPATH, STORM WATER DRAINS IN NORTH EAST ZONE AT RMS. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of brick work/stone boulder masonry, built in cement mortar including all quoins, pillars, etc. but excluding ashler facing, dressed stone work and precast concrete articles. | 199.25 | Cum | |
2 | 2 | Demolition of cement concrete in ground floor and pavings n.exc 15 cm thick below or above ground level. | 49.25 | Cum | |
3 | 3 | M & L for PCC (1:2:4) type B-2 using 40mm graded aggregate as bond stone including necessary form work complete all as specified. | 2 | Cum | |
4 | 4 | M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation complete all as specified and directed. | 5 | Cum | |
5 | 5 | M & L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping including necessary form work all as specified and directed. | 2 | Cum | |
6 | 6 | M & L for walling of random rubble, uncoursed well bounded bedded and solidly hearted, built in CM (1:6) including provision of weep holes complete all as specified and directed. | 140 | Cum | |
7 | 7 | All as per ser No 6 here-in-before but except stones | 5 | Cum | |
8 | 8 | M&L for raised pointing to random or polygonal rubble uncoursed or brought up to course in CM (1:4) complete all as specified and directed. | 10 | Per 10 Sqm | |
9 | 9 | S&F for 110 mm dia PVC (SWR) pipe single socketed in any length with rubber joints laid in trenches/,floor/weep holes and similar work all as specified. | 60 | Rm | |
10 | 10 | Demolition of reinforced cement concrete in any position not other wise described. | 5.02 | Cum | |
11 | 11 | Dismantling posts or struts (wood, steel or RCC) any section embeded in concrete, brick work,masonary , incl taking out embedded portion and making good disturbed ground. | 222 | RM | |
12 | 12 | M&L for brick work white sub class 'B' brick straight or curved on plan exceeding 6.00 m mean radius with old size bricks built in cement mortar 1:6complete all as specified and as directed. | 42 | Cum | |
13 | 13 | All as per ser No 12 here-in-before but except bricks. | 3 | Cum | |
14 | 14 | Material & labour for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4. | 50 | Sqm | |
15 | 15 | Taking down cement plaster on brick or stone nails, etc including raking out joints, hacking for key, scrubbing down with water etc. | 400 | Sqm | |
16 | 16 | Demolition and breaking up drain pipes (salt glazed, stoneware, AC or reinforced concrete) set in cement 'mortar 300mm dia fixed in position. | 10 | RM | |
17 | 17 | M&L reinforced concrete pipes, class NP 2 ,300 mm dia laid and jointed complete with collars complete all as specified and directed. | 10 | RM | |
18 | 18 | Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed. | 75 | Each | |
19 | 19 | M&L for PCC type C-1, 1:3:6 (20mm graded aggregate) for bed blocks and similar work as specified. | 9.1 | Cum | |
20 | 20 | M&L in repair for 35 mm thick pre-cast RCC jalli including moulding cement concrete 1:2:4 type B-0 set in CM 1:4 complete all as specified and directed. | 120 | Sqm | |
21 | 21 | M & L Reinforced cement concrete(Nominal Mix) Type B1 1:2:4 using 20mm graded stone agg as in for lintels beams over 1.5m span etc complete | 2.8 | Cum | |
22 | 22 | M&L RCC nomial mix type1:11/2:3 (using 20mm graded stone aggregate) as in slabs and chajjas | 2.7 | Cum | |
23 | 23 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape reqired including cranking, bending spirally for hooping ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT bars | 400 | Kg | |
24 | 24 | ditto item no 23 but, 8 mm dia for stirrups. | 180 | Kg | |
25 | 25 | S&F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) | 18 | Sqm | |
26 | 26 | S&F Form work to edges of rough finished surfaces of concrete flats breaks in floors,openings in concrete walls floors and roofs and sides of RCC/PCC bands in walls horizontal or sloping and similar work | 36.9 | Sqm | |
27 | 27 | M&L for 15 mm thick rendering in CM 1:4 on brick work or concrete surface, including preparation of surfaces and finishing the surfaces fair and even. | 130 | Sqm | |
28 | 28 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished fair and even without using extra cement. | 710 | Sqm | |
29 | 29 | M&L for 75mm thk PCC 1:3:6 type C-2 using 40mm graded agg as in Sub floors,sub bases,floors and paving finished even and smooth without using extra cement | 290 | Sqm | |
30 | 30 | M&L roughening surface of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc. | 80 | Sqm | |
31 | 31 | M&L for 50mm thk PCC 1:2:4 type B-2 using 40mm graded agg as in paving . | 65 | Sqm | |
32 | 32 | M&L for 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. | 350 | Sqm | |
33 | 33 | M & L chequered cement concrete tiles 30cmx 30cm x25mm thick anti fungal with grey cement and pigment set, jointed and pointed in neat cement slurry in floors complete all as specified. | 350 | Sqm | |
34 | 34 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thick (M-40 grade) as in pavement,complete all as specified. etc laying as directed by engr in charge. | 115 | Sqm | |
35 | 35 | M&L Sand filling under floors or in foundations including watering and consolidation | 5.5 | Cum | |
36 | 36 | S&F for mild steel work in post & struts in fencing including cutting tips to shape as directed ,drilling holes notching for wire etc including flat iron fillets for securing wire mesh etc including all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 | 1400 | Kg | |
37 | 37 | S&F Framed work as in grills, gratings, gates etc with ends of bars shouldered and/riveted, or gorged into spikes confirming to Fe-410-0 or Fe-310--0 | 700 | Kg | |
38 | 38 | S&F in repairs 2 strand, steel bared wire 2.24 mm dia bared with 2 mm dia barbed at 75 mm spacing and straining and fixing to any type of standard rail, straining bolts, including securing or tying at crossings with and provision of galvanised MS wire staples of steel pins etc | 22 | Per 100 RM | |
39 | 39 | Supply only chain link MS galvanisd fencing, any size or type all as specified and directed. | 705 | Kg | |
40 | 40 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc; including provision of binding wire. | 500 | Sqm | |
41 | 41 | S & F Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long ( Diameter of neck in n exc 12mm) complete all as specified and as directed. | 25 | Kg | |
42 | 42 | S&F MS round bars 10mm dia and over cut to length bend to shape as required for fixing of chain link fencing. | 150 | Kg | |
43 | 43 | M&L for boulder filling dry, handpacked tightly, as in wire crate apron bunds (Wire crate measured separately) complete all as specified and directed. | 3 | Cum | |
44 | 44 | All as item No 43 here-in-before but except boulder | 0.5 | Cum | |
45 | 45 | S&F for 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling | 10 | Sqm | |
46 | 46 | M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. | 2 | Cum | |
47 | 47 | Precast RCC (1:2:4) type B-1 in drain slab cover etc including necessary form work complete set in cement mortar 1:6 complete. | 2.2 | Cum | |
48 | 48 | Extra for forming fair finished drain or channel 30 cm girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc | 50 | RM | |
49 | 49 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto | 482 | RM | |
50 | 50 | M & L for preparation of new surfaces of wall including scrapping down, smoke soot, efflorescent salts trading oil and greasy spots etc by applying two coat of white wash on walls | 60 | Sqm | |
51 | 51 | M&L for Preparation of old decorated surfaces and appplying one coat of white wash on walls, cornices etc. complete all as specified and directed. | 600 | Sqm | |
52 | 52 | Material and labour for preparation of new external surfaces of walls including cornices, plasters etc (Plastered or un plastered surfaces) and applying two coats of cement paint over one coat of primer complete all as per manufacture instructions all as specified and as diredted by Engineer-in-Charge . | 710 | Sqm | |
53 | 53 | M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade on walls all as specified and directed by Engineer-in-Charge | 1100 | Sqm | |
54 | 54 | M& L for preparation and one coat of Weather proof exterior emulsion paint on brick /concrete surfaces/plasterd surfaces of wall including all scafolding up to 3 storey bldg complete all specified and as directed by Engr in Charge. | 200 | Sqm | |
55 | 55 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and as directed. | 100 | Sqm | |
56 | 56 | All as per item No 55 hereinbefore but applying two coat of synthetic enamel paint over a coat of red oxide on new surfaces. | 70 | Sqm | |
57 | 57 | M&L for preparation of old decorated surfaces of walls including cornices, pilasters etc (plastered or unplastered surfaces) and applying one coat of cement base paint complete as specified and as directed. | 700 | Sqm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy