| 1 | 1 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\n(i) Pakur Variety\na)Ground Floor [Ref : P.W.D.(Bldg.), Page-26, Item No. 10] | | 18.575 | Cu.M.\n |
|---|
| 2 | 2 | Hire and labour charges for shuttering withcentering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)\n(a) 25 mm to 30 mm thick wooden shuttering\nas per decision & direction of Engineer-In- Charge.\ni) Ground Floor [Ref : P.W.D.(Bldg.), Page-42, Item No. 36] | | 186.3 | Sq.m |
|---|
| 3 | 3 | Brick work with 1st class bricks in cement mortar (4:1) (b) In superstructure, ground floor i) Ground Floor [Ref : P.W.D.(Bldg.), Page-15, Item No. 7] | | 91.3 | M3 |
|---|
| 4 | 4 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.\n(a) For works in foundation, basement and\nupto roof of ground floor/upto 4 m\n(i) Tor steel/Mild Steel I. SAIL/ TATA/RINL\n[Ref : P.W.D.(Bldg.), Page-43, Item No. 40] | | 1.8 | M.T.\n |
|---|
| 5 | 5 | 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in first floor. [Ref : P.W.D.(Bldg.), Page-16, Item No. 16] | | 130 | M2 |
|---|
| 6 | 6.1 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor). (ii) With 4:1 cement mortar.i)Ground floor (a) 20 mm thick plaster | | 280 | M2 |
|---|
| 7 | 6.2 | (b) 15 mm thick plaster\n | | 210 | M2 |
|---|
| 8 | 6.3 | (c) 10 mm thick plaster\n[Ref : P.W.D.(Bldg.), Page-189, Item No. 1] | | 75 | M2 |
|---|
| 9 | 7 | Artificial stone in floor, dado, staircase etc. with cement concrete (4:2:1) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring works,using cement @1.75 kg./sq.m. all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted) with ordinary cement. (iii) 35 mm. thick.[Ref : P.W.D.(Bldg.), Page-48, Item No. 6] | | 75 | M2 |
|---|
| 10 | 8 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\n(c) Sal : Siliguri.\n[Ref : P.W.D.(Bldg.), Page-114, Item -1] | | 0.562 | Cu.M\n |
|---|
| 11 | 9 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.\nIn ground floor.\n(In case of non-supply of single plank, penal rate of reduction of 20% will be made)\n(iii) 35mm thick shutters with 19mm thick\npanel of size 30to 45 Cm.\n(a) Ordinary Teak Wood.\n[Ref : P.W.D.(Bldg.), Page-117, Item -1] | | 46.2 | Sq.M |
|---|
| 12 | 10 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\n(Add extra @ 1% for each addl. floor upto\n4th floor and @ 1.25% for each addl. floor above 4th floor)\n(ii) Grill weighing above 16 Kg./sq.mtr and\nabove\n[Ref : P.W.D.(Bldg.), Page-104 Item No. 13] | | 6.72 | Qntl |
|---|
| 13 | 11 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.[Ref : P.W.D.(Bldg.), Page-200, Item -1 (b)] | | 92.4 | M2 |
|---|
| 14 | 12 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.[Ref : P.W.D.(Bldg) 2017, Page-200 , Item No.1(a)] | | 67.2 | M2 |
|---|
| 15 | 13 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) (iv) Two coats (with any shade except white) [Ref : P.W.D.(Bldg) 2017, Page-200 , Item No.2(A)(a)(iv)] | | 92.4 | Sq.M. |
|---|
| 16 | 14 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : With super gloss (hi-gloss) (iv) Two coats (with any shade except white) [Ref : P.W.D.(Bldg) 2017, Page-200 , Item No.2(A)(b)(iv)] | | 67.2 | Sq.m |
|---|
| 17 | 15 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)\n(a) One Coat\ni) Water based interior grade Acrylic Primer\n[Ref: P.W.D (Bldg.), Page -195, Item.- 7] | | 285 | %Sq.M\n |
|---|
| 18 | 16 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification)including cleaning and smoothning of surface.\nTwo Coats [Ref : P.W.D.(Bldg.), Page-196, Item-10] | | 285 | Sq.M |
|---|
| 19 | 17 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer[Ref : P.W.D.(Bldg) 2017, Page-195, Item No.7, a, i] | | 280 | %M2 |
|---|
| 20 | 18 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1000 litre capacity [Ref : P.W.D.( S & P.), Pg. -37, It.-6, (b)] | | 1 | Each |
|---|
| 21 | 19 | 1/2 HP Pump.As per market rate. | | 1 | Each |
|---|
| 22 | 20 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (A)(I) CPVC Pipes Class-1,SDR-1125 mm[Ref : P.W.D.( S & P.), Pg. -30, It.-2, (A) (I)] | | 51 | M |
|---|
| 23 | 21 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (E) Reducing Elbow 25 mm X20 mm[Ref : P.W.D.( S & P.), Pg. -31, It.-2, (E)] | | 20 | Nos |
|---|
| 24 | 22 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (C) Equal Tee 25 mm[Ref : P.W.D.( S & P.), Pg. -30, It.-2, (C)] | | 10 | Each |
|---|
| 25 | 23 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (N) Union 25 mm[Ref : P.W.D.( S & P.), Pg. -32, It.-2, (N)] | | 7 | Each |
|---|
| 26 | 24 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (B) Socket 25 mm[Ref : P.W.D.( S & P.), Pg. -30, It.-2, (B)] | | 7 | Each |
|---|
| 27 | 25 | Labour for fitting and fixing G.I. specials including cost of jointing materials. (d) Cross, Union, Long screw(i) Upto 25 mm dia.[Ref : P.W.D.( S & P.), Pg. -23, It.-35, (d)(i)] | | 14 | Each |
|---|
| 28 | 26 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (Q) Ball Valve 25 mm[Ref : P.W.D.( S & P.), Pg. -33, It.-2, (Q)] | | 4 | Each |
|---|
| 29 | 27 | Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.(iii) 25 mm [Ref : P.W.D.( S & P.), Pg. -53, It.-2, (iii)] | | 2 | Each |
|---|
| 30 | 28 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (O) Reducing Tee 25 mm x 25mm x20mm[Ref : P.W.D.( S & P.), Pg. -33, It.-2, (O)] | | 13 | Each |
|---|
| 31 | 29 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (G) End Cap 25 mm[Ref : P.W.D.( S & P.), Pg. -31, It.-2, (G)] | | 6 | Each |
|---|
| 32 | 30 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (J) Male threaded adopter 25 mm[Ref : P.W.D.( S & P.), Pg. -32, It.-2, (J)] | | 6 | Each |
|---|
| 33 | 31 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (R) Female threaded adopter 25 mm [Ref : P.W.D.( S & P.), Pg. -33, It.-2, (R)] | | 5 | Each |
|---|
| 34 | 32 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (P) Pipe Clip 25 mm [Ref : P.W.D.( S & P.), Pg. -32, It.-2, (P)] | | 25 | Each |
|---|
| 35 | 33 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (A)(I) CPVC Pipes Class-1,SDR-1120 mm[Ref : P.W.D.( S & P.), Pg. -30, It.-2, (A) (I)] | | 37 | M |
|---|
| 36 | 34 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (C) Equal Tee 20 mm [Ref : P.W.D.( S & P.), Pg. -30, It.-2, (C)] | | 12 | Each |
|---|
| 37 | 35 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (E) Reducing Elbow 20 mm X15 mm [Ref : P.W.D.( S & P.), Pg. -31, It.-2, (E)] | | 21 | Each |
|---|
| 38 | 36 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (X) Male Elbow (Brass threaded) (Dia) 20mm [Ref : P.W.D.( S & P.), Pg. -34, It.-2, (X)] | | 13 | Each |
|---|
| 39 | 37 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (R) Female threaded adopter 20mm [Ref : P.W.D.( S & P.), Pg. -33, It.-2, (R)] | | 7 | Each |
|---|
| 40 | 38 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (B) Socket 20mm [Ref : P.W.D.( S & P.), Pg. -30, It.-2, (B)] | | 6 | Each |
|---|
| 41 | 39 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (Q) Ball Valve 20 mm [Ref : P.W.D.( S & P.), Pg. -33, It.-2, (Q)] | | 4 | Each |
|---|
| 42 | 40 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (P) Pipe Clip 20 mm [Ref : P.W.D.( S & P.), Pg. -32, It.-2, (P)] | | 30 | Each |
|---|
| 43 | 41 | Supplying, fitting and fixing bib cock or stop cock. (c) (i) Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand ).\n[Ref: P.W.D (S & P), Page - 5, Item.- 7] | | 6 | Each |
|---|
| 44 | 42 | GST 12% | | 1 | LS |
|---|
| 45 | 43 | Labour wellfare Cess 1% | | 1 | LS |
|---|