Repair And Maintenance Of External Electrification , Lt Panel Board , Dg Sets And Fire Fighting System At Ins Agrani Coimbatore

Tender Notice

26055394
Repair And Maintenance Of External Electrification , Lt Panel Board , Dg Sets And Fire Fighting System At Ins Agrani Coimbatore
Indian
Tamil Nadu
20-11-2020
08-12-2020
10-12-2020

Tender Details

Repair And Maintenance Of External Electrification , Lt Panel Board , Dg Sets And Fire Fighting System At Ins Agrani Coimbatore

Key Value

Document Fees
INR 500 /-
EMD
INR 26000.00 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
BOQ_442729.xls Tender Document-BOQ 1204.00
Tendernotice_1.pdf Tender Document-NOTICE INVITING TENDER 66.95
Tenderdoc.pdf Tender Document-TENDER DOCUMENTS 188.00
A79A854F-83AC-4A36-9A03-B823CA8C9816.html Tender Notice-Tender Notice 0

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIFICATION, LT PANEL BOARD, DG SETS AND FIRE FIGHTING SYSTEM AT INS AGRANI COIMBATORE
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for laying UG cable and getting out in hard / dense soil complete all as specified and as directed. 100 Cum
2 2 Returning filling in soil including spreading, levelling , watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.. 64 Cum
3 3 Removing excavated materials not exceeding 50 Mtr depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.. 36 Cum
4 4 Surface dressing of sub station yards and transformer surroundings not exceeding 15cm deep including removal of vegetation / shrubs/ under growth and carrying away rubbish outside MD land and apply 24 'D' oil mixed with weedicides or mixed with veedol chemical solution and sprayed in the places of possible growth of weeds complete all as specified and directed. 200 Sqm
5 5 M & L for River sand filling in trenches for cushioning of HT / LT cables punning after filling complete all as specified and as directed.\nNote: Punned thickness shall only be measured and paid 30 Cum
6 6 Supply and lay one layer of new sub class 'B' bricks for protection of cable laid flat butting to each other complete.\nNote: While laying, the length of the brick shall be at right angle to the central axis of cable. 3.27 1000 Nos.
7 7 M&L for PCC (1:3:6) type C1 using 20mm graded stone aggregate as in coping of poles above ground level and finishing the exposed concrete surfaces even and fair including provision of necessary form work for fair finished surfaces complete all as specified 1 Cum
8 8 Supply and laying in trenches, or fixing on walls or passing through cable duct / pipe, XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of following sizes including necessary thimble, gland, etc after taking down old item from any situation all as specified:-
9 8.1 90 Sq mm 3.5 core 45 RM
10 8.2 70 Sqmm 3.5 core 80 RM
11 8.3 50 Sq mm 3.5 core 95 RM
12 8.4 35 Sq mm 3.5 core 80 RM
13 8.5 25 Sqmm 3.5 core 60 RM
14 8.6 16 Sqmm 4 core 60 RM
15 8.7 16 Sqmm 2 core 50 RM
16 9 M&L for taking out faulty UG cable and cutting the faulty end and making joint using out door, cable straight through heat shrinkable jointing kit (Epoxy/Heat Shrinkable type) suitable for PVC/XLPE under ground aluminium conductor cable, 1100 Volts grade including crimping aluminium sockets of suitable size complete of following cross sectional area :-
17 9.1 70 -150 Sqmm 3.5 core 5 Each
18 9.2 25-50 Sqmm 3.5 core 8 Each
19 9.3 10-16 Sqmm 4/3.5 core 4 Each
20 9.4 10-16 Sqmm 2 core 3 Each
21 10 M&L for taking out faulty UG cable and cutting the faulty end and making joint using cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. 1 Each
22 11 M&L for taking out faulty UG cable and cutting the fault end and making joint using cable jointing kit 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. \nNote for item No. 9, 10 & 11:- Excavation & earth work, sand cushioning, bricks for protection etc if necessary shall be measured and paid separately. \nMake : Raychem/Cab seal/M-Seal/Denson 1 Each
23 12 M&L synthetic insulating mat of size 2m x 1m x 12 mm for power house complete all as specified and directed. 1 Each
24 13 Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 45 cm for laying GI pipe including making good the surface by returning filling in layers nexc 25cm thick, watering, well ramming in layers and top layer using 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones complete all as specified and directed. 16 SQM
25 14 Supply and lay GI tubing light grade in trenches/under roads/crossings or fixed to wall/pole of following sizes for protection of UG cables including taking down old GI pipe complete all as specified and directed. . Note : Excavation and earth work shall be measured and paid separately under relevant items of Schedule.
26 14.1 80 mm dia 6 RM
27 14.2 50 mm dia 20 RM
28 14.3 25 mm dia 20 RM
29 15 M&L for Servicing of LV ACB of capacity 800 Amps, Ics=100%Icu, ICW 65 kA/1s, cat. B, Micro logic 2.0 A by OEM (i.e. Schneider) . \n 1 Each job
30 15.1 The quoted rate for servicing of ACB shall be inclusive of the following :-\n(a) Dismantling, cleaning and assembling of front cover, push button, locking devices.\n(b) Dismantling, cleaning of arc chute cover and terminal shield.\n(c) Dismantling, cleaning, checking and assembling of arc chute.\n(d) Dismantling, cleaning / greasing and assembling of electrical spring charging motor.\n(e) Dismantling, cleaning, checking / testing and assembling of tripping coil / closing coil.\n(f) Dismantling, cleaning and tightening of protection relay.\n(g) Checking of main contact wear by physical inspection.\n(h) Cleaning and greasing of breaker main mechanism by Schneider recommended fully synthetic imported multipurpose grease to increase the reliability in terms of mechanical as well as electrical properties and their endurance.\n(j) Inspection of main spring/tripping spring/locking spring.\n(k) Dismantling / cleaning and greasing of spring charging handle.\n(l) Inspection / cleaning of breaker rear terminals and greasing them.\n(m) Inspection / cleaning of the changeover contacts of the OF Switch.\n(n) Dismantling, cleaning, greasing and assembling of cluster.\n(o) Checking and cleaning, greasing of hand pull-out system, racking mechanism of.\n(p) Chassis and function position indicators\n(q) Checking and tightening of control unit connection block and chassis rear terminals.\n(r) Cleaning & cleaning of tightness of wires on WAGO terminals.\n(s) Checking healthiness of protection relay type Micro logic mounted on Breaker (Tripping current and tripping time) by dedicated Schneider Test kit.\nNote :- RAR / Payment for this item will be allowed only after submission of detailed report from the OEM of ACB i.e. Schneider.
31 16 Supply and fix lightning arresters expulsion type complete with all fittings transmission class, discharge capacity of 65 kilo amphere suitable for 11KV complete all as specified and directed \nMake :BHEL/MEI/GEC 6 Each
32 17 M&L Pin type porcelain, vitreous white, Brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150mm height 150mm dia for 11000Volts grade complete all as specified . Make:BHEL/Mysore porcelain/madras porcelain 5 Each
33 18 M&L for painting existing feeder pillar boxes and numbering and mark the location from where the cables incoming and outgoing, with two coats of synthetic enamel paint over a coat of red oxide primer after preparing the old painted surfaces by rubbing and cleaning the dust, rust in FP boxes and Panel board installed in various location complete all as specified and directed by Engr -in-Charge. 30 Sqm
34 19 S&F in repairs Digital Multi function Energy meters accuracy class 0.5 Feeder pillar /panel Board mounted type to measure Electrical parameters of V, A, F, PF, kW, kVA, etc including suitable ratio CTs in FP boxes and Panels installed at in various locations of INS Agrani including replacement of connected wiring with multistranded copper conductor cable etc complete including testing on completion. (Note: Disturbed surfaces of Panel Board to be rectified neatly) Make : L & T/Siemens/Schneider 2 Each Job
35 20 S&F cable route indicator over the LT cables made out of cast iron block of size 100mm dia and thickness 10mm fixed with MS angle of size 25 x 25 x4 mm up to length 1 ft and marked with 'MES LT cable ___ sqmm' or LOOP OF LT CABLE ___ sqmm' as required on cast iron block including PCC 1:2;4 type B1 100x100x150mm and earth work complete all as specified and as directed. 20 Each
36 21 S&F cable route indicator over the HT cables made out of cast iron block of size 150mm dia and thickness 10mm fixed with MS angle of size 25 x 25 x4 mm upto length 1 ft and marked with 'MES LT cable ___ sqmm' or LOOP OF HT CABLE ___ sqmm' as required on cast iron block including PCC 1:2;4 type B1 100x100x150mm and earth work complete all as specified and as directed. 10 Each
37 22 S&F danger notice plate 25 x 20 cm, 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts for HT. 5 Each
38 23 S&F danger notice plate of 20 x 15 cm,1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts for LT . 10 Each
39 24 Disconnecting 4 core cables from the existing MCCB/MCB's installed in LT panel and reconnecting the same with new lugs /thimbles to the existing MCCB/MCB in FP box and Panel Boards installed in various location including repair the panel board by welding as required, fixing new hinges 04 Nos, bends, dents etc and replacement of lock complete all as specified and directed. \nNote : Complete Panel MCCB measured as one Job. 15 Each Job
40 25 M&L AIR BREAK, GANG OPERATED SWITCHES 11 KV triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating upto 200 amps including all connection complete all as specified and directed. 1 Each
41 26 M&L expulsion fuses single phase 11 KV above 10 Amps & upto 30 Amps complete all as specified and directed. 14 Each
42 27 M&L Aluminium Conductor Steel Reinforced for jumper including PVC sleeves complete all as specified and directed.\nNote:-\n(i) The rates quoted shall include supply and fixing of copper binding wire or aluminium tapes which shall not be included in the weight of conductors. \n(ii) Weight of conductors shall be calculated from the tables given in the relevant I.S. \n 0.5 Qtl
43 28 S&F MCCB 4 pole 160 amps of breaking capacity 36 kA conforming to IS /IEC 60947-2, Ics=100%Icu adjustable over load from 0.8 0 1.0 x In, Adjustable short circuit from 6 - 10 x Ir, complete all as specified and directed by Engr-in-Charge. \nModel/Make : Cat part No. CM92109OON1OG of make L&T or Cat part No. 3VL2716-2EM46-0AA0 of make Siemens or equivalent in Schneider. 2 Each
44 29 All as per item No.28 above but MCCB 4 pole 100 amps capacity. Model/Make : Cat part No. CM92108OOL1OG of make L&T or equivalent in Schneider / Siemens. 2 Each
45 30 All as per item No.28 above but MCCB 4 pole 200 amps capacity. Model/Make : Cat part No. MC92109OON1OG of make L&T or equivalent in Siemens/Schneider. 1 Each
46 31 All as per item No.28 above but MCCB 4 pole 250 amps capacity. Model/Make : Cat part No. CM92109OOP1OG of make L&T or equivalent in Schneider / Siemens. 1 Each
47 32 Supply and filling in Transformers with Transformer oil of dielectric strength not less than 40 KV and conforming to IS-335. 50 Ltr
48 33 De-hydration/ filtration of transformer oil by employing on line filtration plant to achieve di-electric strength not less than minimum 40 KV including following work services :- \n(a) Removal of all suspended particles such as dust, rust, scales, collided Carbone oxidation sludge, etc upto < 1 micron. (b) De-hydration of transformer oil under vacuum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level.\nNOTE : (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately as "Supply only" (iii) Conducting field testing of di-electric strength of the transformer oil before and after filtration (iv) Checking the megger/earth resistance values with battery operated megger of 5 KV 920 Ltr
49 34 Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with galvanised strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified including taking down of old item and as directed by the Engr-in-Charge. \nNOTE :- (i) Cost of GI pipe light grade 40 mm shall deemed to be included in the quoted rate (ii) GI strip and GI pipe length of upto 7.5 RM shall deemed to be included in the quoted rate and over and above shall be measured and paid separately 6 Each Job
50 35 M&L for Painting "HT 2 pole structure of steel tubular poles including cross arms, back plates, bracings of all exposed surfaces of steel items fixed with pole" n.exc 60 cm girth with two coats of aluminium paint over a coat of red oxide primer after preparing the old painted surface by rubbing and cleaning the dust, rust complete all as specified and directed. 20 10 RM
51 36 Disconnecting all cable connections from existing LT panel board including taking down existing MCCB/MCB's etc and fixing the LT panel board and accessories in new location as per direction of Engr-in-Charge and reconnecting the cable including making the foundation as required complete all as specified and directed.\nNote:- Before quoting the rate, the bidder shall visit the site to ascertain the size and type of panel board and no claim will be entertained at a later stage regarding the scope of work. The quoted rate shall be inclusive of PCC (1:2:4) foundation similar to that existing at site. 3 Each Job
52 37 M&L for general servicing the existing outdoor type Ring Main Unit - SF 6 unit with one incoming load breaker switch and three outgoing VCB 630A, 12 KV, 21 KA from OEM i.e. M/s Schneider including following work:-\nNote :- \n(a) All the necessary consumable which are used during the servicing are imported exclusively for Schneider.\n(b) RAR/Payment will be allowed only after submission of detailed service report from OEM (M/s Schneider). 1 Each Job
53 37.1 (i) cleaning/decarbonizing of all, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc for proper functioning, \n(ii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, de-moisturing of all parts \n(iii) Testing of relay tripping performance of RMU. Following tests will be carried out :- \n (a) Primary injection test .\n (b) IR test with megger.\n(iv) Checking of all relays and interlocking if any \n(v) Calibration, performance testing and necessary adjustment of relays for successful operation at the time of fault occurrence etc,\n(vi) Checking of operating mechanism adjustments, measurements of the mechanical clearances of the operating mechanism, internal wiring circuit etc, tightening of all connections, replacement of unserviceable fuse/MCB SP including removing moisture deposit inside the RMU \n(vii) Checking all end terminals, lighting the nut, bolt and washers, replace the unserviceable nut, bolt & washers, engage the RMU with the supply system and testing for smooth functioning complete all as specified.
54 38 Dismantling the existing lightening conductor from MAP building and Overhead water tank and refixing the same with provn of new PVC saddles of suitable size complete all as specified and directed by Engr-in-Charge.\n Note :- \n(a) The contractor shall make his own arrangement of scaffolding required for the dismantling or refixing of the lightening conductor. \n(b) The rates includes installation and dismantling scaffolding after completion of Work. 140 RM
55 39 M&L for air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed. 4 Each
56 40 M &L for test terminal block made of gun metal or phosphorus bronze of size 75X75X25mm drilled and screened including 3 Nos 8mm dia 25mm long hexagonal screws all as specified. 8 Each
57 41 M&L earth continuity conductor or main earthing lead fixed to wall on bittern or recess or chase or buried in ground or drawn in conduit or pipe or fixed to poles or any other indicated situation for loop earthing etc of 25 x 3 mm size aluminium strip complete all as specified and directed by Engr-in-Charge. 20 RM
58 42 M&L for Replacement of set of fuel pre-filters and fine filters as per sample and make for following capacities of DG sets . \nNote: Each set comprising of the complete pre/fine filters shall be provided at site
59 42.1 100 KVA DG set 2 EACH SET
60 42.3 30 KVA DG set (For NST). 1 EACH SET
61 42.4 10 KVA DG set (for NOM). 1 EACH SET
62 43 M&L for Replacement of set of lub/engine oil filters as per sample and make of the following capacities of DG sets.
63 43.1 100 KVA DG set 2 EACH SET
64 43.2 30 KVA DG set (For NST). 1 EACH SET
65 43.3 10 KVA DG set (for NOM). 1 EACH SET
66 44 M&L for Replacement of flexible fuel pipes with banjo bolts and nuts as per sample length and size to meet the requirement of site condition. 2 EACH
67 45 S&F Battery terminal clamp made up of brass with bolts and nuts. 6 EACH
68 46 Repair/ servicing of radiator assembly complete by cleaning cooling water spaces, and replace unserviceable rubber hose, pipes, circlip, clamps, cleaning of radiator mixed with appropriate cleaning agent, de-scaling by means of scale solvent as well as neutralizing agent to arrest leakages by means of brazing etc all as directed of following capacities:- \nNote: \n(i)These servicing includes necessary replacement of gaskets, sealing rings, cleaning agents etc all as directed by Engineer in Charge.\n(ii)coolant will be measured and paid separately.
69 46.1 100 KVA DG set 2 EACH JOB
70 46.2 30 KVA DG set (For NST). 1 Each job
71 47 Repair/servicing /overhauling/ calibration of the fuel injection pump with injectors of following capacities of DG sets. Note: The rate is deemed to be included for necessary sealing rings, ‘O’ rings if needs replacement etc and render necessary test/servicing certificate from the authorized dealer. ( Note: if required item will be measured)
72 47.1 100 KVA DG set 2 Each
73 47.2 30 KVA DG set (For NST). 1 Each
74 47.3 10 KVA DG set (for NOM). 1 Each
75 48 M&L for servicing of after cooler (turbo cooler) in radiator assembly complete for cleaning, cooling air spaces, and replace unserviceable rubber hose, pipes, circlip, clamps, cleaning of after cooler in radiator mix with appropriate cleaning agent, de-rusted by means of scale solvent as Specified and directed for 100 KVA DG set . 2 Each Job
76 49 M&L for servicing Turbo charger 4K Model 1080TA part no 4H.1437.10 Make : TEL with all connected accessories all as specified and directed. 2 Each job
77 50 M&L for servicing Load unbalance controller with replacing of burn out wiring in power alternator all as specified and directed. 2 Each job
78 51 Supply and fix in repairs AVR suitable for 100KVA DG set all as specified and directed. 2 Each
79 52 Supply and fix in repairs Battery charger 12 Volt 10 amps SMPS trigger and boost with connected accessories and wiring all as specified and directed. \nMake: Nagoba/ TVS or Equivalent. (10 KVA - 01 No and 30 KVA- 01 No.) 2 EACH JOB
80 53 M&L for radiator anticorrosive coolant conditioner properly mixed up with the radiator water (K cool/MAK/Bosch) all as specified and directed.\nNote; on every service of radiator the coolant will be changed completely and according the hrs of run the coolant will be top up. 130 LTRS
81 54 Supply and filling engine oil 20W - 40 ( Note : The quoted rate including of drain out old unserviceable engine oil from engine oil sum on occasion of clean the Oil Sump and according the Hrs of run oil will be top up ) all as specified and directed. 65 LTRS
82 55 Repair/servicing/cleaning of diesel tank thoroughly and drain out of diesel complete and keep in safe custody for reuse and clean the dirt/sedimentation in the tank , refilling the diesel to the tank and all as specified and directed for the following capacities of DG sets:-\nNote: (i) Container for drain out of DHPP to be provided by the contractor.\n
83 55.1 100 KVA DG set 2 EACH JOB
84 55.2 30 KVA DG set (For NST). 1 EACH JOB
85 55.3 10 KVA DG set (for NOM). 1 EACH JOB
86 56 Repair/servicing of 12 volts lead acid batteries all plates including reconditioning, replacing the old electrolyte, refilling the batteries with fresh electrolyte, recharging the batteries to its required specific gravity and re-fixing and testing all as directed. 3 EACH JOB
87 57 M&L for servicing of self starter assembly of DG sets 24/12 volts of following capacities by disconnecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, bushes, contact plates,bentex, jumping levels etc and rewinding the unserviceable field coil and varnishing all as directed.
88 57.1 100 KVA DG set 2 EACH JOB
89 57.2 30 KVA DG set (For NST). 1 EACH JOB
90 57.3 10 KVA DG set (for NOM). 1 EACH JOB
91 58 Repair/Replacement of dynamo after removing from the DG set of capacity 100 KVA and transporting to an authorised service centre including replacement of following parts :-\n(i) Armature of suitable size 1 No. \n(ii) Bearing bushes of suitable size 1 set \n(iii) Voltage regulator of suitable size 1 EACH JOB
92 59 Supply only Ignition key suitable for DG set panel/control panel 1 EACH
93 60 Supply only MCCB 63 amps breaking capacity 25 KA, 3 Pole suitable for Control panel/AMF panel 2 EACH
94 61 Supply only Main contactor suitable for 100 KVA AMF Panel 2 EACH
95 62 Supply only Main contactor suitable for 30 KVA AMF Panel 1 EACH
96 63 Supply only Auxiliary/Control contactors (2NO, 2NC) of suitable ratings for AMF Panels of 100 KVA capacity 1 EACH
97 64 Supply only Plug in relay 12 V DC 8/11 pins suitable for AMF Panels 1 EACH
98 65 Supply only multifunction digital meter (in lieu of voltmeter, ammeter, PF meter) suitable for new version AMF Panels 1 EACH
99 66 Supply only CT's of suitable rating for Control panel/AMF panel for 100KVA DG set 1 EACH
100 67 Supply and fixing of battery of capacity 2 x 12 volts of any make and model.:Exide or its equivalent 1 EACH
101 68 Supply and replacement of hinges of canopy door of DG set. (Left &right Casting hitches) 4 EACH
102 69 Supply and fix radiator fan "V' belt for DG set t 100 KVA 2 EACH
103 70 Supply and fix radiator fan "V' belt for DG set t 30 KVA 1 EACH
104 71 Supply and fix radiator fan "V" belt for DG set 10 KVA 1 EACH
105 72 Replacement of extension of exhaust pipe size 100 mm dia with 40x4 mm angle support and ss cladding with asbestos packing all as specified and directed by Engineer in charge.\nNote:- work has to be executed in three different locations for two number 100 kva dg set and one 30 kva dg set. 6 RM
106 73 M&L for removing electric connection and taking down the fire pump set 20 HP capacity from roof of MAP Building and transporting the same to work shop and dismantling the pump set and servicing all the effected parts like, bronze impeller, casing, gland with robe shaft synthetic rubber push and replacing unserviceable parts if any and reconnecting the pump set, painting with two coat of synthetic enamel paint and bringing back to the original location / site and commissioning, testing to the entire satisfaction of Engineer in charge \nNote:-\n(i) The quoted rate is inclusive of cost of all unserviceable items to be replaced and transportation to and from the workshop.\n(ii) .Before commencement of the work/ taking down fire pump, the contractor shall to inform the same to unit I/C and JE in charge being emergency fire motor (FIRE PUMP) 1 Each Job
107 74 S&F in repairs CI butterfly valve conforming to IS 13095, 80mm (3") dia 1 Each Job
108 75 S&F in repairs hose reel of 20mm dia and 30 mtr length conforming to IS 5132. 1 Each Job
109 76 S&F in repairs hose box for keeping 2 Nos hose pipe of length 15 m each branch pipe nozzle coupling etc of MS sheet of thickness 2.0mm.at Ground floor. 2 Each Job
110 77 S&F in repairs 63mm dia gun metal branch with 12.5 mm nozzle conforming to IS 903. 1 Each Job