Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-12-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-12-2020 |
| 2 | 15-12-2020 | 82094 Corrigendum 1 | Financial Bid | 18-12-2020 |
| Name of the Work: Special repairs to Building No. P – 33 at INHS Kalyani, Visakhapatnam | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001111 | 928 | Square Metre |
| 2 | 2 | M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001112 | 2848 | Square Metre |
| 3 | 3 | M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001113 | 2068 | Square Metre |
| 4 | 4 | M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 4380 | Square Metre |
| 5 | 5 | M & L for preparation of old painted wood and wood based surfaces of any description not other wise described over 10 cm width or girth and applying Two coats of synthetic enamel paint complete all as specified and directed. | BI01010001010000000000000515BI0100001115 | 1569 | Square Metre |
| 6 | 6 | M & L for Complete removal of existing treatment of any description on Wall surfaces and applying three coats of white washing complete all as specified and as directed. | BI01010001010000000000000515BI0100001116 | 206 | Square Metre |
| 7 | 7 | M & L for Complete removal of existing treatment of any description on Ceiling surfaces and applying three coats of white washing complete all as specified and as directed. | BI01010001010000000000000515BI0100001117 | 1621 | Square Metre |
| 8 | 8 | M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001118 | 265 | Square Metre |
| 9 | 9 | Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. | BI01010001010000000000000515BI0100001119 | 2924 | Square Metre |
| 10 | 10 | M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.\nNote: Water proofing compound will be measured and paid separately. | BI01010001010000000000000515BI0100001120 | 703.2 | Square Metre |
| 11 | 11 | M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001121 | 2623.5 | Square Metre |
| 12 | 12 | S & F in repairs Plain Aluminium Sheet Alloy 31000 H4 in Ridges, Hips, Valley Gutter, drip and straight flashing, Cover for Crumple Joint, of 0.71 mm thick complete all as specified and as directed. | BI01010001010000000000000515BI0100001122 | 100 | Square Metre |
| 13 | 13 | M & L for Cutting / Chipping and removing loose material from existing crumple joint of any description and trimming, cleaning the surfaces of any thickness and filling the groove of size 25mmX10mm with Cement Mortar 1:3 duly modifying the mortar with Nito Bond SBR of Fosroc Chemicals or its equivalent in Sika India Pvt Ltd / Choksey Chemicals / Bostik India Pvt Ltd / Dr. Fixit @ 2 Litres per Bag of cement and sealing with Thioflex 600GG two-part polysulphide sealant including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. | BI01010001010000000000000515BI0100001123 | 190 | Running Metre |
| 14 | 14 | M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. | BI01010001010000000000000515BI0100001124 | 298 | Square Metre |
| 15 | 15 | M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. | BI01010001010000000000000515BI0100001125 | 100 | Square Metre |
| 16 | 16 | M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. | BI01010001010000000000000515BI0100001126 | 50 | Square Metre |
| 17 | 17 | M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.\nNote: Water proofing compound will be measured and paid separately. | BI01010001010000000000000515BI0100001127 | 450 | Square Metre |
| 18 | 18 | M & L for 40 mm average thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Padding over roof slabs etc. including mixing water proofing compound as per manufacturers instructions and finishing the top surface rough complete all as specified and as directed.\nNote: Water proofing compound will be measured and paid separately. | BI01010001010000000000000515BI0100001128 | 1306 | Square Metre |
| 19 | 19 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description including PCC padding of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.\nNote: Water proofing compound will be measured and paid separately. | BI01010001010000000000000515BI0100001129 | 1306 | Square Metre |
| 20 | 20 | M & L for Plain / Chequered Cement Concrete Tiles of size 250 X 250 mm / 300 X 300 mm, 25mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. | BI01010001010000000000000515BI0100001130 | 1306 | Square Metre |
| 21 | 21 | S & F Calcium Silicate False Ceiling made out of 15mm thick, 595 x 595 mm size Tiles of siliceous and calcareous material reinforced with cellulose fibre fixed to the Exposed Metal Frame Ceiling Grid of 600mm x 600mm size and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer and including Exposed Metal Frame Work using GI Main \"T\" Runner of size 25X35mm, 0.7mm thick, spaced 1200mm centre to centre, Cross \"T\" of size 25X35mm, 0.7mm thick, 1200 mm long spaced between Main \"T\" at 600 mm centre to centre to form a grid of 1200X600 mm and secondary Cross \"T\" of 600mm long and of size 25X35mm, 0.7mm thick of the 1200x600mm panel to form grid of size 600x600mm, resting on periphery walls / partitions on GI Perimeter Wall Angle of size 25X25X3000 mm, 0.70 mm thick with the help of rawl plugs at 450mm centre to centre with 35mm long dry wall screws including cutting/making opening for services like diffusers, grills, light fittings, smoke detectors etc., wherever required. Main \"T\" Runners shall be suspended from ceiling using GI Soffit Cleats made of GI Channels of 1.8 mm thick, having unequal flanges of 37 mm and of 25 mm and web of 25 mm fixed to ceiling with 6mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised steel level clips of size 85x30x2mm, spaced at 1200mm centre to centre along Main \"T\". Bottom exposed width of 25 mm of all sections shall be pre-painted with polyester baked paint at all heights including Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed. | BI01010001010000000000000515BI0100001131 | 2130 | Square Metre |
| 22 | 22 | Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. | BI01010001010000000000000515BI0100001132 | 144 | Cubic Metre |
| 23 | 23 | Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed. | BI01010001010000000000000515BI0100001133 | 3735 | Square Metre |
| 24 | 24 | M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for flooring complete all as specified and as directed. | BI01010001010000000000000515BI0100001134 | 3123 | Square Metre |
| 25 | 25 | M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 8 to 9 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. | BI01010001010000000000000515BI0100001135 | 2400 | Square Metre |
| 26 | 26 | M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE. | BI01010001010000000000000515BI0100001136 | 3401 | Square Metre |
| 27 | 27 | M & L for Glazed Polish finished coloured Chequered Cement Concrete Tiles of thickness 23 to 25mm, made with M-25 Grade Precast Cement Concrete, Hydraulically pressed of size not less than 300 X 300 mm, of approved shape, colour and pattern, set, jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. | BI01010001010000000000000515BI0100001137 | 352 | Square Metre |
| 28 | 28 | Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed. | BI01010001010000000000000515BI0100001138 | 306 | Each |
| 29 | 29 | Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed. | BI01010001010000000000000515BI0100001139 | 319 | Each |
| 30 | 30 | S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. | BI01010001010000000000000515BI0100001140 | 5 | Cubic Metre |
| 31 | 31 | S & F Factory made, 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. | BI01010001010000000000000515BI0100001141 | 181 | Square Metre |
| 32 | 32 | S & F Factory made, 30mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [b] and fitted to Chowkats complete all as specified and as directed. | BI01010001010000000000000515BI0100001142 | 37 | Square Metre |
| 33 | 33 | M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, Window, Ventilator Shutters, Sliding or Openable Type, with or without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos], Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc. per Door Shutter complete all as specified and as directed. \nNote: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I.\n[b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately.\n[c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze / Grills etc. | BI01010001010000000000000515BI0100001143 | 4351 | Kilogram |
| 34 | 34 | S & F Aluminium Powder Coated [Minimum 50 Micron thick] Sections as in Window and Ventilator Shutters, Sliding / Side Hung Type, without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No] per Shutter complete all as specified and as directed.\nNote: [a] Supply only panel inserts such as Glass / Gauge / Grills will be measured and paid separately.\n[b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Locking Arrangement and fixing only of Panel inserts such as Glass / Gauge / Grills etc. | BI01010001010000000000000515BI0100001144 | 468 | Square Metre |
| 35 | 35 | S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed. | BI01010001010000000000000515BI0100001145 | 420 | Running Metre |
| 36 | 36 | S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \"C\" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed. | BI01010001010000000000000515BI0100001146 | 69 | Square Metre |
| 37 | 37 | S & F Factory Made Solid PVC Moulded Door Shutter, with Particle Board Core, 28 to 30mm thick [Stiles], with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing shown on Serial Page No. 161 of MES Schedule Part - II complete all as specified and as directed. | BI01010001010000000000000515BI0100001147 | 69 | Square Metre |
| 38 | 38 | Supply only 5mm thick Sheet Glass ordinary quality in squares exceeding 0.5 Sq.m in each pane complete all as specified and as directed. | BI01010001010000000000000515BI0100001148 | 530 | Square Metre |
| 39 | 39 | S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. | BI01010001010000000000000515BI0100001149 | 202 | Each |
| 40 | 40 | S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed. | BI01010001010000000000000515BI0100001150 | 236 | Each |
| 41 | 41 | Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104, including Powder Coated Aluminium Channel of size 30 X 12 X 1.5mm for fixing Deco Grill complete all as specified and as directed. | BI01010001010000000000000515BI0100001151 | 838 | Square Metre |
| 42 | 42 | Supply only 12mm thick, Prelaminated Particle Board, One Side Decorative Choice Lamination and other side Balancing White, Medium Density, Interior Grade complete all as specified and as directed. | BI01010001010000000000000515BI0100001152 | 38 | Square Metre |
| 43 | 43 | S & F 125 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed. | BI01010001010000000000000515BI0100001153 | 606 | Each |
| 44 | 44 | S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed. | BI01010001010000000000000515BI0100001154 | 168 | Each |
| 45 | 45 | S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed. | BI01010001010000000000000515BI0100001155 | 404 | Each |
| 46 | 46 | S & F Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed. | BI01010001010000000000000515BI0100001156 | 126 | Each |
| 47 | 47 | S & F Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or stainless steel wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001157 | 297 | Square Metre |
| 48 | 48 | S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed. | BI01010001010000000000000515BI0100001158 | 118 | Each |
| 49 | 49 | S & F PVC Solid Ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube, the two vatted profiles are to be reinforced with 19 x 19mm MS square tube, 50% of bottom portion is fixed with 4mm thick pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass louvers and covered with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001159 | 30 | Square Metre |
| 50 | 50 | M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001160 | 596 | Square Metre |
| 51 | 51 | S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed. | BI01010001010000000000000515BI0100001161 | 719 | Running Metre |
| 52 | 52 | S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001162 | 350 | Each |
| 53 | 53 | S & F in repairs 50mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed. | BI01010001010000000000000515BI0100001163 | 621 | Running Metre |
| 54 | 54 | S & F 50 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001164 | 300 | Each |
| 55 | 55 | S & F 75 mm bore PVC [SWR] Junction Single [Single \"T\"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001165 | 102 | Each |
| 56 | 56 | Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, Cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed. | BI01010001010000000000000515BI0100001166 | 1041 | Running Metre |
| 57 | 57 | Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. | BI01010001010000000000000515BI0100001167 | 27 | Cubic Metre |
| 58 | 58 | Demolition of Reinforced Cement Concrete as in Roof, Floors [other than ground floor], beams, staircase, landing, Chajjas and similar suspended work including reinforcement cut as required to facilitate demolition and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. | BI01010001010000000000000515BI0100001168 | 13 | Cubic Metre |
| 59 | 59 | M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed. | BI01010001010000000000000515BI0100001169 | 31 | Cubic Metre |
| 60 | 60 | M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed. | BI01010001010000000000000515BI0100001170 | 221 | Square Metre |
| 61 | 61 | M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Facias & fins etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001171 | 19 | Cubic Metre |
| 62 | 62 | M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001172 | 8 | Cubic Metre |
| 63 | 63 | M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Chajjas and the like complete all as specified and as directed. | BI01010001010000000000000515BI0100001173 | 7 | Cubic Metre |
| 64 | 64 | M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves, Chajjas and the like including use and removal of steel formwork for fair finished surfaces complete all as specified and directed. | BI01010001010000000000000515BI0100001174 | 9 | Cubic Metre |
| 65 | 65 | Use and removal of steel formwork to Fins, Louvers, Fascia and similar works for fair finished surfaces of concrete complete all as specified and as directed. | BI01010001010000000000000515BI0100001175 | 389 | Square Metre |
| 66 | 66 | Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for fair finished surfaces of concrete complete all as specified and as directed. | BI01010001010000000000000515BI0100001176 | 107 | Square Metre |
| 67 | 67 | Use and removal of steel formwork to Chullah hoods, Chajjas, troughs and similar items including edges and similar works for fair finished surfaces of concrete complete all as specified and as directed. | BI01010001010000000000000515BI0100001177 | 91 | Square Metre |
| 68 | 68 | Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed. | BI01010001010000000000000515BI0100001178 | 45 | Square Metre |
| 69 | 69 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. | BI01010001010000000000000515BI0100001179 | 4887 | Kilogram |
| 70 | 70 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. | BI01010001010000000000000515BI0100001180 | 831 | Kilogram |
| 71 | 71 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. | BI01010001010000000000000515BI0100001181 | 572 | Kilogram |
| 72 | 72 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. | BI01010001010000000000000515BI0100001182 | 95 | Cubic Metre |
| 73 | 73 | M & L for preparing surfaces of sunken floor and applying a coat of Brush Bond of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed at site. | BI01010001010000000000000515BI0100001183 | 240 | Square Metre |
| 74 | 74 | M & L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting Cement Slurry mixed with Grout Admixture \"CONBEXTRA EP 10\" of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. at 225 Grams for 50 KG of cement complete all as per manufacturers instructions and as directed. | BI01010001010000000000000515BI0100001184 | 240 | Square Metre |
| 75 | 75 | M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:3, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.\nNote: Water proofing compound will be measured and paid separately. | BI01010001010000000000000515BI0100001185 | 240 | Square Metre |
| 76 | 76 | M & L for PCC 1:5:10, Type E-2, using 40mm graded stone aggregate as in Sunken Floors etc complete all as specified and as directed. | BI01010001010000000000000515BI0100001186 | 79 | Cubic Metre |
| 77 | 77 | M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. | BI01010001010000000000000515BI0100001187 | 158 | Square Metre |
| 78 | 78 | S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001188 | 210 | Running Metre |
| 79 | 79 | S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001189 | 210 | Running Metre |
| 80 | 80 | S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001190 | 336 | Running Metre |
| 81 | 81 | S & F GI water tubing of 40 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001191 | 100 | Running Metre |
| 82 | 82 | S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed. | BI01010001010000000000000515BI0100001192 | 42 | Each |
| 83 | 83 | S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 40 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed. | BI01010001010000000000000515BI0100001193 | 4 | Each |
| 84 | 84 | S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001194 | 42 | Each |
| 85 | 85 | S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed. | BI01010001010000000000000515BI0100001195 | 42 | Each |
| 86 | 86 | S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed. | BI01010001010000000000000515BI0100001196 | 42 | Each |
| 87 | 87 | S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001197 | 42 | Each |
| 88 | 88 | S & F in repairs Two Way Bib Tap, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001198 | 42 | Each |
| 89 | 89 | S & F in repairs, Stop / Angle Valves, 15 mm bore dia of pipe, Fancy type, Chromium Plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed. | BI01010001010000000000000515BI0100001199 | 126 | Each |
| 90 | 90 | S & F in repairs Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed. | BI01010001010000000000000515BI0100001200 | 42 | Each |
| 91 | 91 | S & F 110mm bore PVC [SWR] \"P\" & \"S\" Trap with grating including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001201 | 42 | Each |
| 92 | 92 | S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed. | BI01010001010000000000000515BI0100001202 | 744 | Running Metre |
| 93 | 93 | S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. | BI01010001010000000000000515BI0100001203 | 50 | Running Metre |
| 94 | 94 | S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001204 | 200 | Each |
| 95 | 95 | S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. | BI01010001010000000000000515BI0100001205 | 50 | Running Metre |
| 96 | 96 | S & F in repairs 32mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. | BI01010001010000000000000515BI0100001206 | 42 | Running Metre |
| 97 | 97 | S & F 75 mm bore PVC [SWR] Junction Single [Single \"T\"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001207 | 102 | Each |
| 98 | 98 | S & F 110 mm bore PVC [SWR] Junction Single [Single \"T\"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001208 | 102 | Each |
| 99 | 99 | S & F in repairs 600 mm X 450 mm Bevelled Edge Mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed. | BI01010001010000000000000515BI0100001209 | 42 | Each |
| 100 | 100 | S & F in repairs 1200 mm X 1000 mm Bevelled Edge Mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed. | BI01010001010000000000000515BI0100001210 | 42 | Each |
| 101 | 101 | S & F in repairs 75mm bore PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001211 | 84 | Each |
| 102 | 102 | S & F in repairs Health Faucet with 1 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-577 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. | BI01010001010000000000000515BI0100001212 | 42 | Each |
| 103 | 103 | S & F in repairs Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc., grating and union for discharge pipe, CP screws etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001213 | 14 | Each |
| 104 | 104 | M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection / Hardstanding etc. surface finished even and smooth with out using extra cement complete all as specified and as directed. | BI01010001010000000000000515BI0100001214 | 183 | Square Metre |
| 105 | 105 | M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed. | BI01010001010000000000000515BI0100001215 | 164 | Running Metre |
| 106 | 106 | M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed. | BI01010001010000000000000515BI0100001216 | 1000 | Square Metre |
| 107 | 107 | M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed. | BI01010001010000000000000515BI0100001217 | 450 | Running Metre |
| 108 | 108 | Dismantling of Structural Steel work including Doors, Gates etc but excluding framed trusses complete all as specified and as directed. | BI01010001010000000000000515BI0100001218 | 5 | Quintal |
| 109 | 109 | M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness, conducting Phenolphthalein test and cleaning the surface and ensuring the surface is clean and free from loose particles including disposal and depositing the demolished material out of MD land complete all as specified and as directed. \nNote: During the Phenolphthalein test if it is found that there is no change in the colour, the cutting / chipping of the concrete shall be carried out further down until reaching the good or uncontaminated concrete. | BI01010001010000000000000515BI0100001219 | 150 | Square Metre |
| 110 | 110 | M & L for preparation of the surface by wire brushing and thoroughly cleaning the surface with dry cloth to remove all the dust and applying One Coat of Alkaline Rust Converter of M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions by brush to all accessible parts of exposed rusted metal surface and allowed to react with the chemical for 16-24 hours and the surface shall be again wire brushed to remove any leftover loose particles and finally the surface shall be thoroughly cleaned with clean water complete all as specified and as directed. | BI01010001010000000000000515BI0100001220 | 15 | Kilogram |
| 111 | 111 | M & L for applying One Coat of Corrosion Inhibitor of M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions on entire repair area complete all as specified and as directed. Note: The Corrosion Inhibitor shall be applied after provision of additional reinforcement etc. if any. | BI01010001010000000000000515BI0100001221 | 150 | Square Metre |
| 112 | 112 | M & L for applying Two Coats of Epoxy Phenolic Based / Epoxy Based Anti-Corrosive Protective Coating of M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions by preparing the chemical using a slow speed heavy duty drilling machine fitted with mixing paddle and the prepared solution shall be applied immediately to the cleaned reinforcement and allowed to dry complete all as specified and as directed. | BI01010001010000000000000515BI0100001222 | 20 | Litres |
| 113 | 113 | M & L for applying One Coat / providing impregnation into prepared concrete by using Low Viscosity Resin M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions over the entire repair surface including the portion where new screed is to be laid as per manufacturer’s recommendations and at the rate of not less than 0.25 KG / Sq.m by brush and the resin shall be worked in to all the cracks by repeated application by brush to seal all the cracks by capillary action complete all as specified and as directed. | BI01010001010000000000000515BI0100001223 | 35 | Kilogram |
| 114 | 114 | M & L for applying One Coat of Epoxy Bond Coat [Twp Pack] M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions to ensure perfect bonding between old concrete and new treatment including preparation of the surface as per manufacturer’s instructions complete all as specified and as directed. | BI01010001010000000000000515BI0100001224 | 150 | Square Metre |
| 115 | 115 | M & L for applying Polymer Modified Mortar made using Shrinkage Compensated Polymer Modified Fibre Reinforced Cementitious Repair Mortar such as Renderoc SP 40 of M/s. Fosroc Chemicals India [P] Ltd. or equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions to form average 20 mm thick even surface complete all as specified and as directed. | BI01010001010000000000000515BI0100001225 | 150 | Square Metre |
| 116 | 116 | M & L for Micro Concreting for jacketing of Columns using Single component, shrinkage compensated, high strength, high flow cementitious micro-concrete having compressive strength minimum of M40 at 28 days such as Sikkarep Microcrete-4 of M/s. Sika India Pvt. Ltd. or equivalent in M/s. Fosroc Chemicals India [P] Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions blended with washed saturated surface dry [SSD], graded, low absorption, high density, aggregates of size 3mm to 10mm at 50% by weight of micro concrete [if thickness is 100mm or more] and water as per data sheet and pouring into the shuttering if required using birds beak type form work using suitable arrangement or if required using pumping device for uniform flow of Micro concrete complete all as specified and as directed. \nNote: The sides shuttering shall be removed preferably after 3 days and the bottom shuttering shall be removed preferably after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. | BI01010001010000000000000515BI0100001226 | 5 | Cubic Metre |
| 117 | 117 | M & L for providing additional reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D by checking the diameter of the existing bars, cutting the necessary main reinforcement to the required length with proper development length, tying / binding / welding with the existing shear connectors / reinforcement so that the additional reinforcement acts monolithically with the existing reinforcement and core concrete complete all as specified and as directed. \nNote: The shear reinforcement shall also be provided as specified here-in-above in the form of 2 \"U\" shaped bars if existing shear reinforcement is found deteriorated / diameter of the bars is reduced. Diameter of the new bar shall be equal to the existing bars. Additional reinforcement shall be provided only in case the diameter of the existing bars is found less than 30% of the original diameter. | BI01010001010000000000000515BI0100001227 | 1400 | Kilogram |
| 118 | 118 | M & L for providing grouting with Injection Grout M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions for cracks caused by structural distress such as shear cracks, flexural cracks, tensile cracks etc. by injecting low viscosity epoxy resin complete all as specified and as directed. | BI01010001010000000000000515BI0100001228 | 6 | Kilogram |
| 119 | 119 | M & L for drilling and fixing PVC Nozzles for injecting cementitious polymeric grout to fill the honeycombing noticed after removal of shuttering inside the beams, columns, slabs etc. including removal of loose concrete material complete all as specified and as directed. | BI01010001010000000000000515BI0100001229 | 100 | Each |
| 120 | 120 | M & L for dismantling existing waterproofing system including PCC Padding, Cement Concrete tiles of any thickness, overlay etc. form the top of the roof slabs to expose the substrate/RCC slab beneath, cleaning the surface by mechanical means to make the surface free from dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and finally the surface shall be thoroughly cleaned with clean water and disposal and depositing the demolished material out of MD land complete all as specified and as directed. | BI01010001010000000000000515BI0100001230 | 250 | Square Metre |
| 121 | 121 | M & L for carrying out water test to identify direct dripping leakages from slab and carrying out Injection Grouting using cement grout admixed with non-shrink admixture such as Cebex 100 of M/s. Fosroc Chemicals India [P] Ltd. or equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. at the location of leakage, cracks and in a grid pattern as per manufacturer's instructions complete all as specified and as directed. | BI01010001010000000000000515BI0100001231 | 250 | Square Metre |
| 122 | 122 | M & L for applying One Coat of Sealer Coat over the bare slab, after proper surface cleaning and completion of injection grouting, using Acrylic polymer such as STP Shalicrete E of M/s. STP Ltd. or equivalent in M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. duly mixed with cement in the ratio of 1:3 per KG of cement and applied by brush as per manufacturer's instructions complete all as specified and as directed.\nNote for Serial Item No. 109 to 122: Rate quoted is deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. Nothing shall be paid extra on this account. | BI01010001010000000000000515BI0100001232 | 250 | Square Metre |
| 123 | 123 | S & F in repairs UPVC Pipe of 110 mm bore, of pressure rating 4 KGf / Sq.cm, Conforming to IS - 4985 including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed. | BI01010001010000000000000515BI0100001233 | 100 | Running Metre |
| 124 | 124 | S & F in repairs Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 304, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed. | BI01010001010000000000000515BI0100001234 | 503 | Kilogram |
| 125 | 125 | M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. | BI01010001010000000000000515BI0100001235 | 213 | Square Metre |
| 126 | 126 | M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Skirting, Dado, Risers of Steps, Jambs, Pillars etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of skirting / dado / risers and joints shall match with the flooring. | BI01010001010000000000000515BI0100001236 | 177 | Square Metre |
| 127 | 127 | Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed. | BI01010001010000000000000515BI0100001237 | 858 | Point |
| 128 | 128 | M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. | BI01010001010000000000000515BI0100001238 | 484 | Point |
| 129 | 129 | All as per Serial Item No. 128 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified. | BI01010001010000000000000515BI0100001239 | 222 | Point |
| 130 | 130 | All as per Serial Item No. 128 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. | BI01010001010000000000000515BI0100001240 | 152 | Point |
| 131 | 131 | S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001241 | 62 | Each |
| 132 | 132 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001242 | 694 | Each |
| 133 | 133 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001243 | 120 | Each |
| 134 | 134 | S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed. | BI01010001010000000000000515BI0100001244 | 222 | Each |
| 135 | 135 | S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001245 | 120 | Each |
| 136 | 136 | S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001246 | 400 | Each |
| 137 | 137 | S & F Bell Push, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. | BI01010001010000000000000515BI0100001247 | 12 | Each |
| 138 | 138 | S & F Bell, Ding Dong / Multi Music Type, AC, 230 Volts, Single Pole complete all as specified and as directed. | BI01010001010000000000000515BI0100001248 | 12 | Each |
| 139 | 139 | S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed. | BI01010001010000000000000515BI0100001249 | 86 | Each |
| 140 | 140 | S & F in repairs TV Socket / Outlet, Co-Axial, Deluxe, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed. | BI01010001010000000000000515BI0100001250 | 13 | Each |
| 141 | 141 | S & F Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified | BI01010001010000000000000515BI0100001251 | 300 | Running Metre |
| 142 | 142 | Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001252 | 250 | Running Metre |
| 143 | 143 | Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001253 | 180 | Running Metre |
| 144 | 144 | Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001254 | 160 | Running Metre |
| 145 | 145 | M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. | BI01010001010000000000000515BI0100001255 | 1540 | Running Metre |
| 146 | 146 | M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit | BI01010001010000000000000515BI0100001256 | 1180 | Running Metre |
| 147 | 147 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit | BI01010001010000000000000515BI0100001257 | 560 | Running Metre |
| 148 | 148 | M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit | BI01010001010000000000000515BI0100001258 | 100 | Running Metre |
| 149 | 149 | M & L for taking down existing MCB TPN DB / Sheet Metal Enclosures including all accessories, cutting holes into or through stone / brick masonry / walling built in cement mortar exceeding half brick and not exceeding one brick thick walls and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required to match with existing after inserting and refixing the MCB TPN DB / Sheet Metal Enclosures including connecting up all accessories complete all as specified and as directed. | BI01010001010000000000000515BI0100001259 | 5 | Each Job |
| 150 | 150 | S & F in repairs MCB DB, TPN, 8 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed. | BI01010001010000000000000515BI0100001260 | 3 | Each |
| 151 | 151 | S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed. | BI01010001010000000000000515BI0100001261 | 3 | Each |
| 152 | 152 | S & F MCB, TPN, 63 Amps, 415 Volts, 50 Hz complete all as specified and as directed. | BI01010001010000000000000515BI0100001262 | 6 | Each |
| 153 | 153 | S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. | BI01010001010000000000000515BI0100001263 | 41 | Each |
| 154 | 154 | S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. | BI01010001010000000000000515BI0100001264 | 247 | Each |
| 155 | 155 | S & F MCB, SPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. | BI01010001010000000000000515BI0100001265 | 82 | Each |
| 156 | 156 | S & F MCCB, FP, 250 Amps, 36 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed. | BI01010001010000000000000515BI0100001266 | 3 | Each |
| 157 | 157 | S & F MCCB, FP, 100 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed. | BI01010001010000000000000515BI0100001267 | 3 | Each |
| 158 | 158 | S & F in repairs Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 2' X 2' Grid False Ceiling of not less than 3600 Lumens output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 | BI01010001010000000000000515BI0100001268 | 159 | Each |
| 159 | 159 | S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1800 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 | BI01010001010000000000000515BI0100001269 | 139 | Each |
| 160 | 160 | S & F Energy efficient Sleek LED Mirror Light Fitting of not less than 1000 Lumens, Surface / Recess mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 | BI01010001010000000000000515BI0100001270 | 26 | Each |
| 161 | 161 | S & F Suspended type LED Tube Light Fittings, of not less than 3600 Lumens output, 5700K, 4 Feet Long with extruded aluminium / CRCA housing and robust construction with necessary polycarbonate diffuser, integrated electronic driver, with all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including hanging with steel / aluminium chain from ceiling to fitting and taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 | BI01010001010000000000000515BI0100001271 | 38 | Each |
| 162 | 162 | S & F in repairs Insect Killer, 40 Watt, UV Tube Catcher, Zapper Repellent Machine of Model No. Jumbo 40-V2 complete all as specified and as directed. | BI01010001010000000000000515BI0100001272 | 5 | Each |
| 163 | 163 | M & L for Taking down Ceiling Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capacitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed. | BI01010001010000000000000515BI0100001273 | 61 | Each Job |
| 164 | 164 | M & L for Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Bearings, Shaft Bushes, Condenser, Rubber Bushes, Nuts & Bolts etc. and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed. | BI01010001010000000000000515BI0100001274 | 25 | Each Job |
| 165 | 165 | S & F in repairs Louvers suitable for Exhaust Fan of 225 to 450mm Sweep including all fixtures complete all as specified and as directed. | BI01010001010000000000000515BI0100001275 | 25 | Each |
| 166 | 166 | S & F in repairs GI Perforated Cable Tray of Size 150mm wide, 75mm Deep, made with 2mm thick Sheet, with Perforation not more than 17.5%, in convenient sections, joined with connectors including all Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc. including taking down existing cables and conduits of any description, rearrangement and fixing the cables inside the cable tray and making good the disturbed surface complete all as specified and as directed. | BI01010001010000000000000515BI0100001276 | 320 | Running Metre |
| 167 | 167 | S & F in repairs MS Stand / Bracket suitable for fixing Outdoor Units of Split ACs of 1.5 / 2.0 Ton capacity including providing double scaffolding and safety measures as required and removal of the same on completion of taking down and fixing new MS Brackets suitable for Outdoor Units of Split ACs of 1.5 / 2.0 Ton capacity complete all as specified and as directed. | BI01010001010000000000000515BI0100001277 | 40 | Each |
| 168 | 168 | S & F in repairs 5/8\" dia Copper Pipe suitable for Split type Air conditioners and connecting between Indoor and Outdoor unit including fixtures and duly insulated with 10mm thick Nitrile Rubber Insulation complete all as specified and directed. | BI01010001010000000000000515BI0100001278 | 100 | Running Metre |
| 169 | 169 | S & F in repairs 1/4\" dia Copper Pipe suitable for Split type Air conditioners and connecting between Indoor and Outdoor unit including fixtures and duly insulated with 10mm thick Nitrile Rubber Insulation complete all as specified and directed. | BI01010001010000000000000515BI0100001279 | 100 | Running Metre |
| 170 | 170 | Supply, lay, test and commissioning of 3 Core, 2.5 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including crimping type cable lugs, sockets etc. and connecting to Indoor and Outdoor units complete all as specified and as directed. | BI01010001010000000000000515BI0100001280 | 80 | Running Metre |
| 171 | 171 | S & F 25mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001281 | 200 | Running Metre |
| 172 | 172 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed. | BI01010001010000000000000515BI0100001282 | 26 | Each Job |
| 173 | 173 | S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided. | BI01010001010000000000000515BI0100001283 | 650 | Running Metre |
| 174 | 174 | S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001284 | 80 | Running Metre |
| 175 | 175 | S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed. | BI01010001010000000000000515BI0100001285 | 18 | Each |
| 176 | 176 | S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed. | BI01010001010000000000000515BI0100001286 | 42 | Each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail