| 1 | 1 | Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line etc for laying of cable, errection of poles, stay and pipe line, complete all as specified and directed. | | 26 | Cum |
|---|
| 2 | 2 | Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed. | | 11.95 | Cum |
|---|
| 3 | 3 | Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified and directed. | | 14.05 | Cum |
|---|
| 4 | 4 | M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed. | | 0.66 | Per 1000 Nos |
|---|
| 5 | 5 | Laying only bricks as in cable protection laid with axis of brick perpendicular to the axis of the cable, for protection of cable complete all as specified and directed. \n(NOTE : Old serviceable bricks as obtained from taking down of cable shall be use in the work) . | | 0.44 | Per 1000 Nos |
|---|
| 6 | 6 | M&L for local sand cushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as specified and directed. | | 10.5 | Cum |
|---|
| 7 | 7 | Supply and fixing of GI tubing light grade of 50 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed. | | 6 | RM |
|---|
| 8 | 8 | Disconnecting, taking out old unserviceable LT UG Cable of size 3.5/4 Core 16 Sq mm to 70 Sq mm from trenches complete for remove including taking down protection cover or bricks , GI Pipe etc complete all as specified and directed. | | 140 | RM |
|---|
| 9 | 9 | Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 25 Sqmm 4 Core laid in trenches or fixed on wall/floor/poles complete all as specified and directed. | | 45 | RM |
|---|
| 10 | 10 | All as per item No. 9 here-in-before but 4 x 16 sq mm cable | | 45 | RM |
|---|
| 11 | 11 | All as per item No. 9 here-in-before but 2 x 10 sq mm cable | | 50 | RM |
|---|
| 12 | 12 | S & F in replacement of MCB TPN 10 KA \"C\" series 415 Volt 40 to 63 Amps complete all as specified and directed. (Make -Havells/Legrand/Schneider/ABB) | | 2 | Each |
|---|
| 13 | 13 | Supply and fixing in replacement of MCCB 3 pole , 100 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. ( Make : Legrand or equivalent in ABB/Schnieder) | | 1 | Each |
|---|
| 14 | 14 | Supply and fixing in replacement of MCCB 3 pole , 160 amp rating of 16 KA adjustable type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. (Make : Legrand or equivalent in ABB/Schnieder) | | 1 | Each |
|---|
| 15 | 15 | Supply and fixing in replacement of energy saving environmental friendly , long life LED street light fitting 25 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separete driver compartment with IP 66 protection including taking down old unserviceable light fitting complete all as specified and directed. (Make :Cat Part No. ENDURAPEARLSL25WLED757SASYTOPCMP of Havells or equivalent in Bajaj/ Philips) | | 6 | Each |
|---|
| 16 | 16 | Supply and fixing in replacement of energy saving environmental friendly , long life LED street light fitting 40 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separete driver compartment with IP 66 protection including taking down old unserviceable light fitting complete all as specified and directed (Make :Cat Part No. ENDURAPEARLNEOSL40WLED757PASYTOPC of Havells or equivalent in Bajaj/ Philips) | | 4 | Each |
|---|
| 17 | 17 | Supply only PVC insulated FR cable with multi strand copper conductor of size 2.5 sq mm through inside of pole / GI pipe bracket including taking down old unserviceable cable complete all as specified and directed. (Make : Plaza/Havells/Standard/Mescab) | | 40 | RM |
|---|
| 18 | 18 | M & L in replacement of security light timer switches Rex surface mounting maxi Rex QT (Daily) 16 A & 250 VAC resistive complete all as specified and directed. Make L&Tor Legrand | | 1 | Each |
|---|
| 19 | 19 | M&L for complete routine test of transformer of Cap 200 KVA & 315 KVA (as per IE rules) with authorised agency once in 6 month as per the direction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any capacity of transformer complete all as specified and directed. | | 2 | Each\nJob |
|---|
| 20 | 20 | Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and directed. | | 60 | Ltr |
|---|
| 21 | 21 | Supply and Replacement of fresh silica Gel complete all as specified and directed. | | 0.25 | Kg |
|---|
| 22 | 22 | M & L for painting of LT pole with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete all as specified and directed. | | 20 | Each |
|---|
| 23 | 23 | M & L for painting of two pole structure with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coat and one finishing coat of aluminium paint complete all as specified and directed. | | 2 | Each |
|---|
| 24 | 24 | S&F in replacrment of Thermoplastic cable junction box IP 65 protection and fixed on street light poles complete with suitable thermoplastic clamps , GI nut bolts and washers suitable for entry of 10/16/25 sq mm 4 core cable of size 240X170X105 mm out side dimensions complete with necessary terminals with 6A SP MCB, earth termination with nuts & bolts, and including 02 sets of 32x6mm flat iron clamps with nuts, bolts and washers complete all as specified and directed. (Make :Hensel /Syntex) | | 16 | Each |
|---|
| 25 | 25 | Supply & Fixing in replacement of new generation, Bamboo IP-65 post-top, energy saving, environmental friendly, long life aestheticalIy designed aluminium landscape luminaire for diffused lighting with high power 8W LED light source complete all as specified and directed . Make :- Havells Cat part No BAMMOOBL8WLED857PSYMTOPCCM(1.0m) /Bajaj/C&G /Phillis | | 10 | Each |
|---|
| 26 | 26 | Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. | | 0.27 | Cum |
|---|
| 27 | 27 | Supply & fixing testing and commissioning in replacement of LT cope box panel board in door type factory made duly finished, cubical type floor mounted of suitable size , Made out from 2.0 mm thick CRCA sheet powder coated mounted on angle iron frame (40mmx40mmx4 mm thick) from structure , three phase 440 volts drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCBs, cable glands of suitable sizes for incoming and outgoing cables,necessary PCC work and with fully compartmentalized design with 4 Nos of copper bus bar of 200 Amps capacity each and including MCB four pole 63 Amp, 25 KA -01 No complete all as specified and directed. | | 1 | Each Job |
|---|
| 28 | 28 | Taking up/down GI tubing from trenches , duct, wall, roof or in any position with all fittings for re-laying /refixing of serviceable pipes and removing the unserviceable pipes for 40mm to 50 mm dia complete all as specified and directed. | | 12 | RM |
|---|
| 29 | 29 | All as per item No. 28 here-in-before but 25 mm dia | | 24 | RM |
|---|
| 30 | 30 | Re-laying old serviceable GI tubing after throughly cleaned the inside of pipes and re-running the old screws threads as required and re-fixed/re-laying in trenches wall or roof etc for 25 mm dia complete all as specified and directed. | | 12 | RM |
|---|
| 31 | 31 | Supply and fixing of GI tubing medium grade of 50 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed. | | 12 | RM |
|---|
| 32 | 32 | All as per item No. 31 here-in-before but 25 mm dia | | 12 | RM |
|---|
| 33 | 33 | Supply and fixing in replacement of brass gun metal gate valve with iron wheel head screwed both ends for iron pipes including taking out old unserviceable valves for 50 mm dia pipe complete all as specified and directed. | | 1 | Each |
|---|
| 34 | 34 | All as per item No. 33 here-in-before but 25 mm dia | | 3 | Each |
|---|
| 35 | 35 | Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing etc for smooth running and replacement of packing gaskets, shaft sleeve, gland packing, neck ring nut bolts and washers etc, with necessary oiling and greassing of 15 HP & 20 HP pump complete all as specified and directed. | | 2 | Job |
|---|
| 36 | 36 | Supply only ball bearing 6310-ZZ/C3(SKF) complete all as specified and directed. | | 2 | Each |
|---|
| 37 | 37 | Supply only ball bearing 6206-ZZ (SKF) complete all as specified and directed. | | 2 | Each |
|---|
| 38 | 38 | Dismantling and taking down of motor from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,discconecting of electric connection from terminal loading/unloading the motor to vehicle and transportation of the motor to workshop, cutting the burnt winding and clean the rotor & stator with CTC or other cleaning material and rewinding of stator winding with super enameled copper wire as per existing the size/gauge wire and turn of the previous winding, insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish . Afterward heating the stator in heat chamber for contineous 2 days for better insulation resistance reassembling the stator & rotor carefully after replacement of worn out bearings, transportation of motor from workshop to its original location, unloading the motor and placing it on base frame, connection of motor with pump with tyre coupling and fixing to the base frame after checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load for continous running for 3 hrs of capacity 15 HP Induction motor complete all as specified and directed. | | 1 | Each |
|---|
| 39 | 39 | M&L for repair, cleaning and servicing of automatic star delta starter of capacity 20 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and directed.\n(Note : Major defective parts will be measured and paid separetely under relevent item as supply only) | | 2 | Job |
|---|
| 40 | 40 | Cleaning and removing yearly all scales and deposited materials in under ground water sump of 2.5 lakhs ltr by drain out the ludge/water at bottom of the tank by mannualy or using non cloging pump sets and applying bleaching powder , brushes for removing deposited materials and removal the same from sump and deposited the same where as directed (not more than 50 mtr) , including cleaning the surrounding area of under ground sump complete all as specified and directed.\nNote :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud outside the premises shall be deemed to include in the above item rate. | | 1 | Job |
|---|
| 41 | 41 | Supply and fixing in replacement of electronic motor protection relay with in-built earth fault protection , over load, single phasing , locked rotor , trip indication of aux supply 240 V AC thermal O/L Range 08 to 22 amps, suitable for capacity of 15 HP complete all as specified and directed. ( Make : Cat No. MPR303BE080 of L&T or similar in Havells/BCH or makes as mentioned in PS) | | 1 | Each |
|---|
| 42 | 42 | All as ser item No 41 hereinbefore but capacity of UG Sump 3 lakhs litter. | | 1 | Job |
|---|
| 43 | 43 | Cleaning and removing yearly all scales and deposited materials in over head tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to surrounding area including draining out existing water complete all as specified and directed. \nNote :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud outside the premises shall be deemed to include in the above item rate. | | 2 | Job |
|---|
| 44 | 44 | M & L in replacement of CI non return butterfly valve suitable for 80 mm dia pipe with complete accessories complete all as specified and directed. | | 1 | Each |
|---|
| 45 | 45 | M&L in replacement of CI Foot Valve for suitable for 150 mm dia Tubing conforming to IS 4038 complete all as specified and directed. | | 1 | Each |
|---|
| 46 | 46 | M&L in replacement of Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 25mm dia iron pipe or brass ferrule and fixed complete all as specified and directed. | | 2 | Each |
|---|
| 47 | 47 | Servicing of authorised agency \"C\" check in replacement of fuel filter, primary and secondary, superbypass filter,oil filter. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling new engine oil complete all as specified and directed for the following capacity :-\n(a) Capacity 200 KVA & 82.5 KVA \nNote:- (a) Engine oil will be measured and paid separately as supply only under respective items of schedule 'A'. \n(b) Each servicing of DG Set will be required after 6 months . \n(c) Air filter will be replaced in each servicing of DG Set as supply only under respective items of schedule 'A'. | | 2 | Each |
|---|
| 48 | 48 | Supply only engine oil suitable for diesel generator set (Oil 15W/40) complete all as specified and directed. Make: Servo/ HP / Bharat Petroleum. | | 26 | Ltr |
|---|
| 49 | 49 | Supply only coolant suitable for radiater of DG sets complete all as specified and directed. Make: HP/TVS or Equivalent. | | 7 | Ltr |
|---|
| 50 | 50 | S&F in replacement of battery terminal brass(heavy duty) with nuts & bolts for battery (as per sample) complete all as specified and directed. | | 4 | Each |
|---|
| 51 | 51 | Supply in replacement of Air filter and air pre filter to DG set complete all as specified and directed of following capacities:- \n(a) Capacity from 82.5 KVA & 200 KVA \n( Note: Each Air filter and air pre filter will be required in each servicing of DG Set ) | | 4 | Each |
|---|
| 52 | 52 | Supply in replacement of diesel filter complete all as specified and directed.\n(a) Capacity from 82.5 KVA & 200 KVA\n( Note: Each diesel filter will be required in each servicing of DG Set ) | | 4 | Each |
|---|
| 53 | 53 | Supply & Fixing for repir and replacement of display board of DG Set 200 KVA Capacity complete all as specified and directed. | | 1 | Each |
|---|
| 54 | 54 | M & L for repairing of automatic battery charger of 24 Volt including winding of transformer unit and replacement of diode plates, rectifier plates, auto cut mosfet circuit , fuses etc. and testing complete all as specified and directed. | | 1 | Job |
|---|
| 55 | 55 | M & L for repair and replacement of Yard hydrant Post / Stand Post 80mmDia GI / MS both flanged type 1.5m height complete all as specified and directed. | | 1 | Each |
|---|
| 56 | 56 | M & L for repair and replacement of Hydrant valve single headed complete all as specified and directed. | | 1 | Each |
|---|
| 57 | 57 | M & L for repair and replacement of CP hose15 mtr long complete all as specified and directed. | | 2 | Each |
|---|
| 58 | 58 | M & L for repair and replacement of RRL hose A 15 mtr long complete all as specified and directed. | | 2 | Each |
|---|
| 59 | 59 | M & L for repair and replacement of Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and directed. | | 6 | Each |
|---|
| 60 | 60 | M & L for repair and replacement of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed. | | 2 | Each |
|---|
| 61 | 61 | M&L for repair of fire fighting hose cabinet box of size 0.8m x.6 m x 0.25mtr (L x W x H) made out of 3 mm thick MS sheet by repairing of broken hinges of cabinet door , replacement of broken door glass with 2 mm thick clear glass of size 45 cm 25 cm size ,repair of door oppen handle , locking arrangement , painting the inside and out side of the box with red colour synethetic enamel paint over a coat of red oxide parimer including carried out of all minor plastering/cement /welding work if required at site complete all as specified and directed. | | 5 | Job |
|---|
| 62 | 62 | Supply & Fixing for repair and replacement of MS ERW pipe 80 mm dia for fire fighting lines including welding and necessary febrication works & painting complete all as specified and directed. | | 12 | RM |
|---|
| 63 | 63 | M & L for painting of Fire fighting lines 80 mm dia with fire red paint after removing old paint from pipe & other steel section bracket & support clamps etc and inclusive of one over coat and one finishing coat of fire red paint complete all as specified and directed. | | 85 | RM |
|---|
| 64 | 64 | All as per above item No 63 but 100 mm dia pipe complete all as specified and directed. | | 85 | RM |
|---|
| 65 | 65 | M & L for painting of Fire fighting Hose box with fire red paint & brilliant white inside yard after removing old paint from Hose box & other steel section bracket & support clamps etc and inclusive of one over coat and one finishing coat of fire red paint complete all as specified and directed. | | 18 | Each |
|---|
| 66 | 66 | Servicing of authorised agency \"C\" check in replacement of fuel filter, primary and secondary, superbypass filter,oil filter. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for fire fitting DG set including drain out (used) engine oil and filling new engine oil complete all as specified and directed for the following capacity :-\n(a) Capacity 65 KVA \nNote:- \n(a) Engine oil will be measured and paid separately as supply only under respective items of schedule 'A'. \n(b) Each servicing of fir fitting DG Set will be required after 6 months . \n(c) Air filter will be replaced in each servicing of DG Set as supply only under respective items of schedule 'A'. (d) Replacement of Battery 12 Volt 63 Ah as supply only under respective items of schedule 'A'. | | 1 | Each |
|---|
| 67 | 67 | Supply in replacement of air filter & air pre filter for fire DG Set complete all as specified and directed | | 1 | Each |
|---|
| 68 | 68 | Supply in replacement of battery 12 Volt 63 AH for fire DG Set complete all as specified and directed | | 1 | Each |
|---|
| 69 | 69 | Dismantling and taking down hot water tank 500 ltrs capacity from the tank stands after disconnecting of in inlet and outlet pipe lines and remove both tanks from bldg roof complete all as specified and directed. | | 2 | Each Job |
|---|
| 70 | 70 | Supply, fixing and testing new pressurised hot water tanks of capacity 500 ltrs on same place of existing tank stands and connecting both outlet and inlet pipes for ready to function complete all as specified and directed. | | 2 | Each \nJob |
|---|
| 71 | 71 | Supply & fixing backup system 2 KW including thermostate 230V in both new tank in replace of damage backup system complete all as specified and directed. | | 2 | Each \nJob |
|---|
| 72 | 72 | Repair & maintenance of hot water pipe lines and existing other hot water tanks incl. stoping leakage of water and damage of packing etc complete all as specified and directed. | | 1 | Each \nJob |
|---|
| 73 | 73 | Cast iron air release valve 25mm dia for solar water system complete all as specified and directed. | | 2 | EACH |
|---|