Sher- I -Kashmir Institute Of Medical Science has published Supply Installation Testing And Commissioning Of Hvac System Reversible Type Heat Pump Unit Water Circulation Pumps Ahu Ducting Allied Piping And Electric Control Panel Etc At New Maternity Hospital Skims Soura. Submission Date for this Tender is 28-11-2020. HVAC Tenders in SKIMS Soura Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25986360
Supply Installation Testing And Commissioning Of Hvac System Reversible Type Heat Pump Unit Water Circulation Pumps Ahu Ducting Allied Piping And Electric Control Panel Etc At New Maternity Hospital Skims Soura
Open Tender
Indian
Jammu And Kashmir
SKIMS Soura
28-11-2020

Tender Details

Supply Installation Testing And Commissioning Of Hvac System Reversible Type Heat Pump Unit Water Circulation Pumps Ahu Ducting Allied Piping And Electric Control Panel Etc At New Maternity Hospital Skims Soura

Key Value

Document Fees
INR 5000 /-
EMD
INR 294000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply, Installation, Testing and Commissioning of HVAC System (Reversible type heat pump units, water circulation pumps, AHU/ Ducting, allied piping & electric control panel etc ) at new maternity Hospital SKIMS, Soura.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Heat Pump\nAir cooled reversible type Heat Pump unit of 140 KW actual capacity at the parameters indicated below. Complete with Screw / scroll compressor, etc. Heat Pump shall have operating parameters as givenbelow: ( 1 No. Standby Heat Pump included in above quantity). \n A. Oxygen system:- Supply, installation, testing and commissioning of 10+10 size manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D-type) along with Non-Return Valves for every cylinder and copper tail pipes as per the Specification on annexure (B) to this NIT.
2 1.1 Cooling Capacity: 200 KW (Min)\nCold water in: 12°C\nCold water out: 7°C\nAmbient Temp. 40°C\nHeating Capacity: 140 KW (min)\nHot water in: 45°C\nHot water out: 50°C\nAmbient Temp. -7°C Providing and fitting of Terminal Units (Gas Outlets) with probes/Adaptors as per NFPA, CSA UL Listed as per NFPA 99, as per the Specification on annexure (B) to this NIT. 2 No
3 2 Water Circulation Pumps\nWater Circulation Monoblock Pump complete with electric motor along with common base frame duly grouted in cement concrete foundation. Suction 65 mm Delivery 50 mm
4 2.1 Capacity 450 LPM at 25 m Head (01 Stand by) 2 No
5 3 Cold Water Piping:-\nAbove Ground\nChilled water Mild steel pipes (Heavy Duty Class) with all necessary fittings like bends, elbows, tees, reducers, hanger, supports, etc and shall be class C as per IS 1239
6 3.1 80 mm DIA 50 RM
7 3.2 65 mm DIA 50 RM
8 3.3 50 mm DIA 100 RM
9 3.4 40 mm DIA 10 RM
10 3.5 32 mm DIA 25 RM
11 3.6 25 mm DIA 10 RM
12 4 Cold Water Pipe insulation\nAbove Ground\nMikron (Mikasha International) Insulation 1000 GSM along with chicken mesh and Aluminium cladding of 24 Gauge. 4 RM
13 4.1 80 mm DIA (50 mm thick, 1000GSM) 50 RM
14 4.2 65 mm DIA (50 mm thick, 750 GSM) 50 RM
15 4.3 50 mm DIA (50 mm thick, 750 GSM) 100 RM
16 4.5 40 mm DIA (50 mm thick, 750 GSM)\n 10 RM
17 4.6 32 mm DIA (25 mm thick, 500 GSM\n 25 RM
18 4.7 25 mm DIA (25 mm thick, 500 GSM)\n 10 RM
19 5 Drain Piping (Rigid PP)\nRigid Poly Propylene 3 mm thick complete with fittings etc as per specifications and drawings.
20 5.1 25 mm DIA 40 RM
21 5.2 32 mm DIA 30 RM
22 6 Make Up Tank\nSupply, installation, testing and commissioning of PVC., makeup tank of following capacities made of PVC 2 layer sheet complete with 50 mm Mikron insulation finished 24 gauge Al cladding complete with vent, drain connections , float valve, quick fill connection, manhole cover etc as specified.
23 6.1 500 ltrs. (for chilled water circuit) 1 No
24 7 Expansion Tank\nSupply ,Installion, Testing & Commissioning of pressurized cold water/ hot water expansion tank with air separator with SS braided pipe flexible connector suitable for total volume of water in cold water circuits along with necessary accessories such as centrifugal air separator, pumps etc. in order to keep cold water system under (+) pressure & to prevent entrapment of air in the system. The tank shall be precharged steel expansion tank with replaceable heavy duty butyl rubber bladder. The tank shall have 50mm system connection & 20mm drain & charging valve connection to facilitate the on site charging of the tank to meet system requirement. The tank shall be fitted with lifting rings & a floor mounting skirt for vertical installation. The tank & air separator must be constructed in accordance with section VIII of the ASME Boiler & Pressure Vessel (Unfired) code & Stamped 125 PSI working pressure. The complete system shall be sourced from single manufacturer & supplied & installed with all accessories & safety fixtures required for proper functioning of the complete hydronic system. The Capacity of tank shall be 500 litres Approx (for chilled water system).Contractor need to quote as per actual requirement with calculation backup duly approved from EIC. 1 No
25 8 VALVES & STRAINERS\nSupply, fixing and testing of following valves, strainers, in the chilled water piping complete with companion flanges, nut bolts, gaskets, supports etc. duly insulated and painted.\nButterfly valves :
26 8.2 65 mm dia. 6 No
27 8.3 50 mm dia. 6 No
28 9 Ball valves :
29 9.1 32 mm 20 No
30 9.2 25 mm 4 No
31 10 Non-Return Valve\ni. 50 mm dia 2 No
32 11 Y-Strainers\n
33 11.1 65 mm dia. 2 No
34 11.2 32 mm dia 10 No
35 11.3 20 mm dia 2 No
36 12 Pressure Gauges\ni. 150 mm dia, dial type (Glycerine filled) 4 No
37 13 Floor/Ceiling Mounted Horizontal AHU:-\nSupplying, Installing, Testing and Commissioning of Double skinned panels of 50mm thickness with internal insulation material PUF with 38±2 kg/cum density sandwiched between two sheets and fixed to extruded aluminum structural AHU Of following parameters:\nRows of Cooling Coil: 4 or as per OEM Rows of Heating Coil: 4 or as per OEM.\n
38 13.1 3000 CFM with static head of 110mm WG 4 No
39 13.2 1500 CFM with static head of 110mm WG 10 No
40 13.3 4000 CFM with static head of 110mm WG 1 No
41 14 Electrical Panel Board\n Electrical Panel Board for AHU made of 16 gauge sheet duly epoxy painted and complete with Cu bus bar, voltmeter, ammeter, indicating lights, selector switch, incoming/ outgoing isolators, single phase preventers, MCB, Relay etc. as recommended by OEM of AHU 15 No
42 15 Heat Recovery Unit (Wheel Type)\nSupply Installation testing and commissioning of heat recovery type treated fresh air unit complete with fresh air inlet section & exhaust air inlet sections with dampers, filter section with a set of MERV 13 Pre & final filters, high efficiency EFF-1 type fan motor, connecting frame, base frame for both the fresh air & exhaust air section. Heat recovery plate, ,2 hrs fire retardant canvass connections and ducting as per site requirement etc.
43 15.1 400 cfm capacity 15 mm static @ 70 % efficiency. 4 No
44 16 SHEET METAL DUCTWORK- Site Fabricated.\nSupply, Fabrication, installation, testing and commissioning of site fabricated Aluminium sheet metal ducting complete with hangers, supports and neoprene gasket sealing as per the specification and approved drawings.
45 16.1 0.8 mm Al ducting 250 Sqm
46 16.2 1.0 mm Al ducting 500 Sqm
47 17 Insulation\nDuct Insulation\n25 mm 1000 GSM thick 100% thermally bonded non woven polyester fibre (MIKRON) insulation with manufacturer approved adhesive covered chicken wire mesh complete in all respect. (for indoor applications).\ni. 25mm thick 650 Sqm
48 18 Duct Acoustic Lining\nAcoustic lining of supply air duct and plenum with 25mm 1000 GSM thick 100% thermally bonded non woven polyester fibre (MIKRON) insulation covered with 0.5 mm thick perforated aluminium sheet fixed to inside surface of duct s with cadmium plated nuts, bolts ,stick pins , CPRX complete as required and as per specifications.\ni. 25 mm thick 100 Sqm
49 19 Aluminium Supply Diffuser\n Diffuser with damper made out of Aluminium extruded section powder coated with white paint. 2.5 Sqm
50 20 Aluminium Supply Grill\n Grill without damper made out of Aluminium extruded section powder coated with white paint. 3 Sqm
51 21 Fire Dampers\nDuct / Wall mounted GI Fire Dampers actuated with the help of 24V electric actuator and as per specifications excluding actuator. 2 Sqm
52 22 Damper Actuator\nMotorised Spring Return Actuator for devices up to 0.8sq.metre with control panel & temperature sensor. 6 No
53 23 Aluminium Duct Damper\nMultiblade box type Aluminium Sheet construction provided with suitable links and quadrants for control of volume of air. 3 Sqm
54 24 Aluminium Grill\nReturn Al powdered coated Grill (For OT)\nH450XW450 mm 16 No
55 25 Fresh Air Louvers\nSupply, installation and testing of Al powdered coated Fresh Air Louvers along with dampers and Bird screen mesh. 4 Sqm
56 26 M.S. Piping (Galvanised)\nMild steel ERW (Galvanised) water piping of class ‘B’ completes with fittings etc as per specifications and drawings.\ni. 25 mm dia. 75 RM
57 27 Providing and fixing of false ceiling of powder coated of aluminium composite panel of 4 mm thick sheets by way of suspending 25 mm wide rectangular AI. /G.I. channel of appropriate thickness from the true ceiling to form grid of 2’x2’size (False ceiling void of 3 feet or as per site requirement) followed by connecting of grid network by means of AI./G.I/ channels to act as a frame in which ACP sheets can be fitted & also should accommodate air diffusers, lighting fixtures as per the site requirement. The levelling of grid has to be accurate throughout including fixtures, hooks, fasteners & attachment rods with slab is also included in the job. \n\n 300
58 28 Main Panel (Heat Pump)\nIncoming from bus bars.\n1No. 630 A TPN MCCB (50 KA) microprocessor releases, Multifunction meter with accessories, phase indicator.\nOut Going\n2No. 5 HP DOL Starter & phase indicating lamps for water Circulation Pumps\n2No. 300 A TPN MCCB (50 KA) microprocessor releases & phase indicating lamps.\n1No. 32 A TPN MCCB (25 KA) for Miscellaneous Load. 1 No
59 29 Cable Try\n300 mm wide Perforated cable tray of 2 mm thickness and supported from ceiling the wall duly painted as per site condition.\n 75 RM
60 30 Conduits\nMS conduit pipes 100 RM
61 31 Electrical cable\nProviding and fixing PVC insulated unarmoured copper/ Al conductor cables from main panel board to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, cable tray etc. as per specifications.\n
62 31.1 3 Core - 1.5 sq.mm Copper unarmoured 10 RM
63 31.2 3 Core - 2.5 sq.mm Copper unarmoured 60 RM
64 31.3 3 Core - 4 sq.mm Copper unarmoured 100 RM
65 31.4 4 Core - 120 sq.mm Al armoured 120 RM
66 31.5 3.5 Core - 240 sq.mm Al armoured 210 RM
67 32 Earthing\nEarthing Pit\nEarthing for various equipments/ heat pump units using copper plate electrode of size 500 x 500x 3 mm placed in 1000 x 1000x 1800 mm pit filled with charcoal & salt by copper strip of size 20 x 3 mm along with perforated G.I pipe as per specifications. 2 No
68 33 Earthing Strip\nGI strip of size 25 mm x 5 mm from earthling electrode to the Panel, heat pumps/ circulation pumps using proper fasteners concealed under floor.\n 200 RM