| Name of Work: CONSTRUCTION OF EVM AND VVPAT STORE AT FOURTH FLOOR IN DAC AT SHAHEED BHAGAT SINGH NAGAR. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | A Construction of EVM's and VVPAT Stripping and stacking slate or tiles of a roof. | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | 883.24 | Sqm. |
| 2 | 2 | Earth work excavation in ordinary soil, exclusive of compensation of earth :--\nEarth work undressed with a combined lead upto 15 metres including breaking of clods. | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 89.6 | Cum |
| 3 | 3 | Dismantling concrete or precast concrete. \nReinforced Cement concrete | 10.47 | Cum | |
| 4 | 4 | Disposal of Malba outside the premises loading / unloading including all leads as desired by Engineer in charge . | 100.07 | Cum | |
| 5 | 5 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. Lintels Fourth Floor | 2.21 | Cum | |
| 6 | 6 | Extra rate for Fourth Floor | 2.21 | Cum | |
| 7 | 7 | Slab Fourth Floor | 115.64 | Cum | |
| 8 | 8 | Extra rate for Fourth Floor | 115.64 | Cum | |
| 9 | 9 | Beams Fourth Floor | 47.98 | Cum | |
| 10 | 10 | Extra rate for Fourth Floor | 47.98 | Cum | |
| 11 | 11 | Shelves Fourth Floor | 0.28 | Cum | |
| 12 | 12 | Extra rate for Fourth Floor | 0.28 | Cum | |
| 13 | 13 | Columns Fourth Floor | 37.94 | Cum | |
| 14 | 14 | Extra rate for Fourth Floor | 37.94 | Cum | |
| 15 | 15 | Facia Fourth Floor | 17.12 | Cum | |
| 16 | 16 | Extra rate for Fourth Floor | 17.12 | Cum | |
| 17 | 17 | Walls Fourth Floor | 13.64 | Cum | |
| 18 | 18 | Extra rate for Fourth Floor | 13.64 | Cum | |
| 19 | 19 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. Fourth Floor | 959.21 | Sqm | |
| 20 | 20 | Extra rate for Fourth Floor | 959.21 | Sqm | |
| 21 | 21 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels Fourth Floor | 401.52 | Sqm | |
| 22 | 22 | Extra rate for Fourth Floor | 401.52 | Sqm | |
| 23 | 23 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain) Fourth Floor | 303.52 | Sqm | |
| 24 | 24 | Extra rate for Fourth Floor | 303.52 | Sqm | |
| 25 | 25 | Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc Fourth Floor | 177.32 | Sqm | |
| 26 | 26 | Extra rate for Fourth Floor | 177.32 | Sqm | |
| 27 | 27 | Centring and shuttering for carbels, parapet, fascias and other similar items including edges. Fourth Floor | 136.96 | Sqm | |
| 28 | 28 | Extra rate for Fourth Floor | 136.96 | Sqm | |
| 29 | 29 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. Fourth Floor | 57.01 | Cum | |
| 30 | 30 | Extra rate for Fourth Floor | 57.01 | cum | |
| 31 | 31 | Fifth Floor | 2.65 | Cum | |
| 32 | 32 | Extra rate for Fifth Floor | 2.65 | cum | |
| 33 | 33 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1):2005 | 80.82 | Cum | |
| 34 | 34 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. Fourth Floor | 149.58 | sqm | |
| 35 | 35 | Extra rate for Fourth Floor | 149.58 | cum | |
| 36 | 36 | 12.5mm thick cement plaster 1:5. | 469.33 | Sqm. | |
| 37 | 37 | 20 mm thick cement plaster 1:5 in two coats work. | 469.33 | Sqm | |
| 38 | 38 | 12.5 mm thick cement plaster 1:4. | 798.1 | Sqm. | |
| 39 | 39 | Extra rate for Smooth Surface of Ceiling. | 741.54 | sqm | |
| 40 | 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp\nU-PVC pipes (working pressure 4kgf. / sqcm)\npipe 110 mm dia. | 68.58 | Rmt. | |
| 41 | 41 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. | 18 | Nos. | |
| 42 | 42 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. \nUPVC 110 mm bend | 38 | Nos. | |
| 43 | 43 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. | 18 | Nos. | |
| 44 | 44 | Providing and fixing in position gratings 150mm x 150mm for gully trap.\nPVC grating | 18 | Nos. | |
| 45 | 45 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing Fourth Floor | 896.84 | Sqm. | |
| 46 | 46 | Extra rate for Fourth Floor | 896.84 | cum | |
| 47 | 47 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. | 127.93 | Rmt | |
| 48 | 48 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping (Using mechanical mixer for mixing of material). Fourth Floor | 776.77 | Sqm. | |
| 49 | 49 | Extra rate for Fourth Floor | 776.77 | sqm | |
| 50 | 50 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. Fourth Floor | 736.31 | Sqm. | |
| 51 | 51 | Extra for Fourth Floor | 736.31 | sqm | |
| 52 | 52 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing Fourth Floor | 36.82 | Sqm. | |
| 53 | 53 | Extra for Fourth Floor | 36.82 | sqm | |
| 54 | 54 | Black Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. Ground Floor | 2.23 | Sqm. | |
| 55 | 55 | Extra labour for projected nosing of stair case of any shape and design | 8.84 | rmt | |
| 56 | 56 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects. | 806.03 | rmt | |
| 57 | 57 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement\nconcrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate | 114.52 | rmt | |
| 58 | 58 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. | 150.41 | rmt | |
| 59 | 59 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) | 132.95 | kg | |
| 60 | 60 | Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects. | 33.24 | Sqm | |
| 61 | 61 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm\nexceeding 0.4 sqm of area Float glass panes of 5.5 mm thickness | 66.48 | sqm | |
| 62 | 62 | Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect | 218.1 | rmt | |
| 63 | 63 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. | 10.73 | qtl | |
| 64 | 64 | Providing and fixing in position collapsible steel shutters, with vertical channels 20mm x 10mm x 2mm and braced with flat iron diagonals 20mm x 5mm size with top and bottom rails of T-Iron 40mm x 40mm x 6mm with 38mm dia steel pulleys, complete with bolts, nuts, locking arrangements, stoppers, handles etc. complete. | 9.02 | Sqm | |
| 65 | 65 | Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects. | 13.11 | Rmt. | |
| 66 | 66 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,\nCommercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-\n 35mm thick | 27.59 | Sqm | |
| 67 | 67 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)\nFor shutter area above 0.50 sqm | 32.29 | Sqm. | |
| 68 | 68 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :\n300mm x 16mm | 13 | Nos | |
| 69 | 69 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete\nI.S.I Designation No. 1 (size of door up to 700mm) | 16 | Nos | |
| 70 | 70 | Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 10mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for stiles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the stiles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. | 4.7 | Sqm | |
| 71 | 71 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. For fixed portion ( For Door Chowkhat) | 14.63 | Rmt. | |
| 72 | 72 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete Fourth Floor | 275.25 | Qtl. | |
| 73 | 73 | Extra rate for Fourh Floor | 275.25 | Qtl. | |
| 74 | 74 | Extra rate for using steel produced by primary producer such as SAIL/RINL/TATA/JINDAL complete in all respect as per the directions of Engineer-in-charge. | 275.25 | Qtl. | |
| 75 | 75 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. | 741.54 | sqm | |
| 76 | 76 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get\nrequired finish | 1736.76 | Sqm | |
| 77 | 77 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade | 1680.2 | Sqm | |
| 78 | 78 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. | 84.52 | Sqm | |
| 79 | 79 | Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work | 84.52 | Sqm | |
| 80 | 80 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. | 62.08 | sqm | |
| 81 | 81 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. | 62.08 | sqm | |
| 82 | 82 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade with ordinary quality paint. | 62.08 | sqm | |
| 83 | 83 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm | 798.1 | sqm | |
| 84 | 84 | Credit of Material to be received from dismentling Tile from dismenling of tile terracing | 19610 | nos | |
| 85 | 85 | Brick/Tile bats | 14.13 | cum | |
| 86 | 86 | PUBLIC HEALTH SERVICES , Sub Work-1 Internal Water Supply, Sewerage, Sanitation, Sub Head-1 Internal Sewerage System, Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.\nSingle Socket Type A 110mm o/d single socket SWR UPVC pipe lines laid complete | 81.68 | mtr | |
| 87 | 87 | 75mm o/d single socket SWR UPVC pipe lines laid complete | 64.61 | mtr | |
| 88 | 88 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm i/d pipes Elbow 90 Degree (All side socketed) | 5 | Nos | |
| 89 | 89 | Vent Cowls | 3 | Nos | |
| 90 | 90 | Coupler | 8 | Nos | |
| 91 | 91 | Single junction with door | 2 | Nos | |
| 92 | 92 | For 75mm i/d pipes Elbow 90 Degree (All side socketed) | 4 | Nos | |
| 93 | 93 | Vent Cowls | 2 | Nos | |
| 94 | 94 | Coupler | 7 | Nos | |
| 95 | 95 | Single Tee with door | 3 | Nos | |
| 96 | 96 | Floor Trap 110mm x 75mm With 75mm i/d outlet deep shallow at Fourth Floor | 5 | Nos | |
| 97 | 97 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm | 1 | Nos | |
| 98 | 98 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal | 1 | Nos | |
| 99 | 99 | Sub Head-2 Internal Water Supply System CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 16mm o/d | 6.1 | mtr | |
| 100 | 100 | SDR 11 CPVC pipes & fittings 20mm o/d | 6.1 | mtr | |
| 101 | 101 | CPVC SDR 11 Pipe & fitting 25mm o/d | 30.48 | mtr | |
| 102 | 102 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 11.43 cm thick | 2 | nos | |
| 103 | 103 | Through wall 22.86 cm thick | 2 | nos | |
| 104 | 104 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 15mm i/d G.I. Union | 2 | Each | |
| 105 | 105 | 20mm i/d G.I. Union | 2 | Each | |
| 106 | 106 | 25mm i/d G.I. Union | 2 | Each | |
| 107 | 107 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. 25mm i/d Brass Ball valves | 2 | Each | |
| 108 | 108 | Sub Head - 3 Sanitary Installation Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. | 2 | Nos | |
| 109 | 109 | Providing and fixing jet spray with 2'-6\" long PVC pipe.With PTMT nut | 2 | Nos | |
| 110 | 110 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. | 2 | Nos | |
| 111 | 111 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube\nconnection 300 mm long complete. | 2 | Nos | |
| 112 | 112 | Providing and fixing partition for different type of urinals.\n19 to 20 mm thick Granite stone partition\nsize 375mm x 750mm | 2 | Nos | |
| 113 | 113 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm | 1 | Nos | |
| 114 | 114 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. | 2 | Nos | |
| 115 | 115 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. \nPVC tube connection of size 15 mm x 375 mm with PTMT nut | 8 | nos | |
| 116 | 116 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. | 1 | nos | |
| 117 | 117 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P. brass towel Rails size 15mm dia 610mm long | 2 | Nos | |
| 118 | 118 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. | 2 | Nos | |
| 119 | 119 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body without flange | 1 | Nos | |
| 120 | 120 | C.P Brass bib cock foam flow without flange | 2 | Nos | |
| 121 | 121 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange | 8 | Nos | |
| 122 | 122 | C.P.brass 15mm Concealed stop cock with flange | 2 | Nos | |
| 123 | 123 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. | 13 | each | |
| 124 | 124 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.\nC.P. Brass extension piece, 25mm long to 50mm long | 13 | each | |
| 125 | 125 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) | 3 | Nos | |
| 126 | 126 | Providing and fixing in position paper holders\nof approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet paper holder | 2 | Nos | |
| 127 | 127 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.\nC.P. Brass khunti with 3 pegs | 2 | Nos | |
| 128 | 128 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. | 3 | Nos | |
| 129 | 129 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. \nDouble Layer Tanks | 1000 | ltr | |
| 130 | 130 | Providing and fixing in position automatic brass Ball Cock in tanks.\nBrass Ball Cock with rod and Plastic Ball Brass Ball Cock with rod and Plastic Ball \n25mm i/d | 1 | Nos | |
| 131 | 131 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 25mm i/d | 1 | Nos | |
| 132 | 132 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge | 1 | Nos | |
| 133 | 133 | Sub Head-4 Flooring and Wall Tile Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping. | 19.49 | sqm | |
| 134 | 134 | Extra rate for Fourth Floor | 19.49 | sqm | |
| 135 | 135 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 1.95 | sqm | |
| 136 | 136 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including jointing the joints with white cement and matching pigment etc., ompletewhite cement slurry in joints including corners angles and beading. Fourth Floor | 19.49 | sqm | |
| 137 | 137 | Extra Rate for Fourth Floor | 19.49 | sqm | |
| 138 | 138 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Fourth Floor | 60.48 | sqm | |
| 139 | 139 | Extra rate for Fourth Floor | 60.48 | sqm | |
| 140 | 140 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. Fourth Floor | 1.49 | sqm | |
| 141 | 141 | Extra rate for Fourth Floor | 1.49 | sqm | |
| 142 | 142 | Extra labour for projected nosing of stair case of any shape and design | 2.44 | rmt | |
| 143 | 143 | Sub Head -5 Water Coller Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer | 1 | Nos | |
| 144 | 144 | Supply & Erection of automatic voltage stabilizer for storage type water cooler, Wall mounted, Heavy duty, copper wounded with volt meter etc. along with 3 core cord of suitable length and 3 pin power shoe including erection, connection & testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. Make... V – Guard or its equivalent. | 1 | Each | |
| 145 | 145 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including\ncarriage and fixing in position complete in all respect. | 1 | Nos | |
| 146 | 146 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Make:- Carrier, Hitachi, Voltas, Blue Star, Daikin or equilant with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace includi | 2 | Each | |
| 147 | 147 | Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within t | 20 | mtr | |
| 148 | 148 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.\nuPVC Pipe 10 Kgf/cm2\n25mm i/d | 20 | mtr | |
| 149 | 149 | Electrical services Providing Internal Electrical Installations Wiring fan point with sheet metal fan box RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: \nWiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of\nmodules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Make :- PVC Pipe = Anchor, Polycab, Norpack, Adarh Plast, Diplast. PVC Copper Wires = Tamra, Gemscab, KEI, Ecko, RR kabel, Rallison, Havell's, L&T, V-Guard,HPL, ..Accessories:-North-West(Nova), Havell's (Crab Tree), Legrand (Myrius), Hager Wining fan point with shet metal fan box | 52 | Each | |
| 150 | 150 | Wiring light point | 81 | Each | |
| 151 | 151 | Wiring 3 pin 6 Amp. wall socket point | 8 | Each | |
| 152 | 152 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point | 11 | Each | |
| 153 | 153 | Wiring 3 pin 16/20 amp. power plug control point | 8 | Each | |
| 154 | 154 | Wiring call-bell point | 2 | Each | |
| 155 | 155 | Wiring light point with double control switches. | 2 | Each | |
| 156 | 156 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:\nSupply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Make:-Tamra, Gemscab, KEI, Ecko, RR kabel, Rallison, Havell's, L&T, V-Guard,HPL, . Overall size 1 sq.mm (Un-sheathed) | 300 | Mtr. | |
| 157 | 157 | Overall size 2.5sq.mm (Un-sheathed) | 130 | Mtr. | |
| 158 | 158 | Overall size 4sq.mm (Un-sheathed) | 250 | Mtr. | |
| 159 | 159 | Overall size 10sq.mm (Un-sheathed) | 100 | Mtr. | |
| 160 | 160 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):-\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-\n Overall size 50sq.mm (3½ Core) Un-armoured (Loose) | 200 | mtr. | |
| 161 | 161 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:\nSupply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-\nMake:- Anchor, Polycab, Norpack, Adarh Plast, Diplast. Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed | 100 | Mtr. | |
| 162 | 162 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed | 60 | Mtr. | |
| 163 | 163 | PVC Flexible Pipe 40mm dia. | 20 | Mtr. | |
| 164 | 164 | HEAVY GUAGE WELDED CONDUIT PIPES:\nSupply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-\n Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. | 70 | Mtr. | |
| 165 | 165 | COPPER EARTHING:8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long | 6 | nos | |
| 166 | 166 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) | 50 | mtr | |
| 167 | 167 | MINIATURE CIRCUIT BREAKERS:-\nSupply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit\ncurrent fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- \nMake:- Siemens (Beta Guard), Legrand (Lexic) , Schneider (Acti-9), L&T (Exora),Hager MCB Single Pole 6-32amp. (10kA, Curve-C) | 36 | Each | |
| 168 | 168 | MCB Four Pole 40amp. (10kA, Curve-C) | 1 | Each | |
| 169 | 169 | MCB Four Pole 50, 63amp. (10kA, Curve-C) | 1 | Each | |
| 170 | 170 | MCB Triple Pole 40amp. (10kA, Curve-C) | 1 | Each | |
| 171 | 171 | MCB Triple Pole 50,63amp. (10kA, Curve-C) | 3 | Each | |
| 172 | 172 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:\nSupply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-\nMake:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGER\n TP&N Horizontal Double Door Distribution Board 4 way each. | 1 | Each | |
| 173 | 173 | TP&N Vertical Double Door Distribution Board 8 way each | 1 | Each | |
| 174 | 174 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-\nMake:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGER Cable End Box for TPN 4 Way | 1 | Each | |
| 175 | 175 | Cable End Box for TPN Vertical 4/8/12Way | 1 | Each | |
| 176 | 176 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-\nMake:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGER TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp) | 1 | Each | |
| 177 | 177 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES:\nSupply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- IC Four Pole Changeover Switch 100amp., 415volts | 1 | Each | |
| 178 | 178 | MOULDED CASE CIRCUIT BREAKERS:\nSupply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.\nMake: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,Legrand MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting | 1 | Each | |
| 179 | 179 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:\nSupply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including\nexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-\nMake :-TeleRex,Gemni,CPE,Dura Line Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) | 180 | mtr | |
| 180 | 180 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make: Jaquar LGLZ01X020XC / Philips BN02IC LED20S PSU CW GR/ Havells ENDURALINEARNEOBS20WLED830SPCWH, Crompton:-LDL-20-CDL,WIPPRO:-LL20-221-XXX-65 ALI, C&S:-LTTB4F20WLED/W | 3 | Each | |
| 181 | 181 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- WIPRRO:- LL24-541-XXX-57-CD,BAJAJ Cat No. BCLAB40W ,JAQUAR CAT NO. LGLZ01X040XC, PHILLIPS Cat no:-BN108C LED 40 S PSU CDL WH , CROMPTON:-LDL-40-CDL,C&S:-LTTB4F40WLED /W,HAVELLS:-STOUTPLUS1200BS40WLED840SPCWH | 78 | Each | |
| 182 | 182 | Supply and erection of Heavy duty Exhust Fans 300mm 900RPM double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make:- Crompton EXHD300-6-1 /Havells Turbo Force SP / Anchor Anmol Heavy Duty . | 2 | Each | |
| 183 | 183 | Supply and erection of Ceiling Fan 1200mm (FIVE STAR), 48\" with double ball bearing including flexible wire & petty material etc. for connections and testing . complete in all respects as appd. and desired by the Engineer in-charge at site. Makes:- Crompton Entrust 50-5 Star Opel White/ Havell's ES-50/ ANCHOR:-Panta Turbo Star code 13671WH / V-Guard Coolgate 5 Star 48, Halonix:- Zephyr(ISI With 5 Star Rating) | 52 | Each | |
| 184 | 184 | Extension of Fire Detection and Alram System for 4th Floor Supply & erection of Photoelectric intelligent Addressable type Smoke Detector that combine photo Electronic and fixed temp thermal with inbuilt isolator or isolator base complete with LED Hard Addressable Having rotary decade Address switches, with Mounting Base for each detector complete as required conforming to BS 5839 standards and duly approved by EN54/UL/VDS complete the in all respect up to the entire satisfaction of Engineer-in-Charge of work. (Make: Honeywell-Morelay,bosch/ siemens fire finder /GST) \n | 52 | Job | |
| 185 | 185 | Supply, Erection, Testing and Commissioning of Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with Back Box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS complete the in all respect up to the entire satisfaction of Engineer-in-Charge of work.(Make: Honeywell-Morely,bosch/ siemens fire finder /GST) | 2 | Job | |
| 186 | 186 | Supply, Erection, Testing and Commissioning of response indicator in polymer box having 2 LED to glow and voltage current of 24v/5ma complete in all respect as desired by the engineer in charge at site.Make- Honeywell / Bosch / Hocahi / Agni/ National/ Agni Suraksha /siemens fire finder. | 6 | Nos. | |
| 187 | 187 | Supply, Erection, Testing and Commissioning of Addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS complete the in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make: Honewell MORLEY / GST / Bosch | 2 | Nos. | |
| 188 | 188 | HEAVY GUAGE WELDED CONDUIT PIPES:\nSupply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- HGW Conduit Pipe 25mm dia. (1.6mm thick) Flushed | 200 | Each | |
| 189 | 189 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:\nSupply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Make:-Polycab, Tamra, KEI, Ecko, RR kabel, Rallison, Havell's, V-Guard, . Overall size 1.5sq.mm (Un-sheathed) | 300 | Mtr. | |
| 190 | 190 | D3 Providing Advance Lightning Protection System Supply, Erection, Testing and Commissioning of Early Steamer Emission Air Terminal Advance Lightning Protection System Complete with (1)Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct lighting point as well conducting /diverting it to earth completely after tracing the lighting in advance.It should based on corona discharge technology uses the naturally occuring electrical field to complete the timely release of an upward streamer. The air terminal must be capable of handling multiple strokes of lighting currents & should be maintenance free.The material should be non corroding in all weather conditions.The air terminal must be totally autonomous electric device collecting the energy from the ambient electrical field.It allows lightning current to follow low resistance path through down conductor to ground,protect the structure from physical damage.The ESE Air Terminal generates controlled magnitude & frequency pulses at the tip of the terminal during high static fields prior to the lightning discharge.The insulation material used to electrically isolate the panels shall be comparised of a base polymer which provides high Ozone and UV resistance.\nAs per NF C 17-102:2011 the air terminal should be tested for lighting impulse current (10/350 micro sec)=100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 107mtr High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast.(ESE Air Terminal--Make:-(3) 3Nos.Maintenance Free Chemical Earthing System with UL Approved Copper Bonded Rod and exothermically welded Cu Busbar both tested by CPRI at 50kA Fault Current. A Copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper bonding thickness of minimum 250 microns. Along with Earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A Copper clad steel solid ground wire of 8 mm dia. For interconnecting earth pits including earth pit covers is required.Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber.The grounding minerals should not be pollute the ground water.The grounding minerals shall be tested & certified for the resistivity of less than 0.12ohm mtr.\n •Make:-copper bonded 17.2 mm dia steel rod JK /GROWTH,Back Fill Compound JK RESLOW/ GROWTH, ESCOLTRIX/LPI/JMV\n(2)GI Mast 5 mtr height including Guy wire to support Mast along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector / Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conductor, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.(4) Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system.This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures.It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs above the ground level .5)Test Link of non-corroding,weather proof,water proof polycarbonate IP 65/55 enclosure including providing of 2 nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire.The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor.\n(6) PVC Insulated 70 Sq.mm copper conductor wire as down conductor to connect the air terminal and erthing\n\n\n | 1 | nos | |
| 191 | 191 | D4 Providing Security Lighting Supply and erection of LED Flood Light 120watt (including LED driver),Pressure Die cast aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- Jaquar LFLDO2S0120XC/ Philips BVP122 LED 124 CW HE AK55° FG XTFCL S4 / Crompton :-LFLN-120-CDL/60-M/ Havells:- JETAIRISFLS120WLED757ASYMLTG /WIPRO:- LF20-132-060-57-G2. | 10 | Nos | |
| 192 | 192 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 10sq.mm (3Core) Un-armoured (On-Surface) | 200 | mtr | |
| 193 | 193 | D5 Supply, Erection, Testing and Successful Commissioning of Diesel Generating Set1 No. 40KVA (For Total Load) Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 40KVA/32KW, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be CRDI air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).\nENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 ( With CPCB-II Norms) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.\nENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication.\nALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.\nACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size plinth of RCC as per specifacation including making of plinth for DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge..Make- GREAVES COTTON/CUMMINS/KOEL GREEN/MAHINDRA\n | 1 | Job | |
| 194 | 194 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):\nSupply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-\nMake :- Polycab,KEI, Grandlay, Ecko, RR kabel, Rallison, Havell's, Overall size 50sq.mm (3½ Core) Un-armoured (Loose) | 100 | nos. | |
| 195 | 195 | COPPER EARTHING:8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long | 4 | nos. | |
| 196 | 196 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) | 10 | mtr | |
| 197 | 197 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:\nSupply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including\nexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-\nMake :-TeleRex,Gemni,CPE,Dura Line Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) | 180 | mtr | |
| 198 | 198 | D6 Providing 10kva UPS (For Total Load) Supply, Erection, Testing & commissioning of 10 KVA/8 KW online , pure sine wave UPS with enclosure suitable for 3 phase AC input and 3 phase AC output with battery backup 30 Mins (min. VAH= 17100 VAH). (Special Features:-Advanced Microprocessor Control,Manual by-pass facility,Switching device shall be IGBT,Input:305-478 VAC (3-phase) @ 100% load,Output:3 x 360*/380/400/415 VAC (3Ph+N),Operating Temp. -00C to 400 C,Total harmonics distortion at output: ? 2-3 % THD (Linear Load) ; and ? 5 % THD (Non-linear Load),overall efficiency (minimum 94%),Over voltage, short circuit and overload,protection at UPS output terminal,Under voltage protection at battery terminal,Audible Alarm operators on fault conditions ,Digital meter shall be provided for monitoring Output AC voltage, current and frequency, LCD Display on front Panel.With i34 nos.120ah Battery,Rack for Battery,Battery interconnecting cables,cables between UPS and Battery and Bttery circuit breaker as approved & desired by the Engineer incharge at site. Make:-UPS -FUJI ELECTRIC/ ZEBRONIC /MICROTECK/NUMERIC--Battery :-SMF Exide/Quanta/Leoch/Zebronic | 1 | Job |