Construction And Refurbishment Of Existing Building For Establishment Of Operation Command Center Occ And Ascdcl Hq, Construction and Refurbishment of Existing Buildin-Maharashtra

Smart City Development Corporation Limited has published Construction And Refurbishment Of Existing Building For Establishment Of Operation Command Center Occ And Ascdcl Hq. Submission Date for this Tender is 19-11-2020. Building Work Tenders in Construction and Refurbishment of Existing Buildin Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

25910725
Construction And Refurbishment Of Existing Building For Establishment Of Operation Command Center Occ And Ascdcl Hq
Open Tender
Indian
Maharashtra
Construction and Refurbishment of Existing Buildin
19-11-2020

Tender Details

Construction And Refurbishment Of Existing Building For Establishment Of Operation Command Center Occ And Ascdcl Hq

Key Value

Document Fees
INR 5000 /-
EMD
INR 505000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction & Refurbishment of Existing Building for Establishment of Operation Command Center (OCC) & ASCDCL HQ
Sl. No. Item Description Item Code / Make Quantity Units
1 1 A-DISMANTLING Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete As directed by Engineer in charge. 1 Nos
2 2 Ground Floor 649.28 sqm.
3 3 First Floor 710.54 sqm.
4 4 Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete As directed by Engineer in charge. 1 Nos
5 5 Ground Floor 8 Nos
6 6 First Floor 16 Nos
7 7 Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. As directed by Engineer in charge. 1 Nos
8 8 Ground Floor 3 Nos
9 9 First Floor 6 Nos
10 10 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. As directed by Engineer in charge. 1 Nos
11 11 Ground Floor 63 sqm.
12 12 First Floor 71 sqm.
13 13 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. As directed by Engineer in charge. 1 Nos
14 14 Ground Floor 34.07 cum
15 15 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. As directed by Engineer in charge. 1 Nos
16 16 Ground Floor 249.95 cum
17 17 First Floor 223.83 cum
18 18 Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. As directed by Engineer in charge. 1 Nos
19 19 Ground Floor 3.51 cum
20 20 First Floor 72.15 cum
21 21 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. As directed by Engineer in charge. 1 Nos
22 22 Ground Floor 34.35 cum
23 23 First Floor 26.62 cum
24 24 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. As directed by Engineer in charge. 1 Nos
25 25 Ground Floor 103.025 cum
26 26 TOTAL OF A 1 Total
27 27 B. RENOVATION WORK 1 Nos
28 28 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Bd.A.1 Page No. 259 4.34 cum
29 29 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. As directed by Engineer in charge. 4.34 cum
30 30 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd. E. 1 Page No. 287 94.96 cum
31 31 Providing preconstructional anti termite treatment as per I.S.6313(Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. 626.15 sqm.
32 32 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.6 Page No. 300 and B.7, Page No.38 1 Nos
33 33 Ground Floor 2.8 cum
34 34 First Floor 2.44 cum
35 35 Providing Auto claved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part3)-1984 in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc.Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) 1 Nos
36 36 Ground Floor 127.96 cum
37 37 First Floor 120.22 cum
38 38 Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.E. 3/Page No. 288/I.S. 456 (2000) 1 Nos
39 39 First Floor 2.49 cum
40 40 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Bd.C.2 Page No. 275 1 Nos
41 41 First Floor 3.04 M.T.
42 42 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) As directed by Engineer in charge 1 Nos
43 43 First Floor 181.83 sqm.
44 44 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd. F. 13 Page No. 305 /I.S. 456 (2000 1 Nos
45 45 Ground Floor 5.77 cum
46 46 First Floor 5.77 cum
47 47 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.9 Page No. 303 and B.7, Page No.38 1 Nos
48 48 Ground Floor 2.12 cum
49 49 First Floor 1.85 cum
50 50 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page No. 306 \n 1 Nos
51 51 Ground Floor 1.45 M.T.
52 52 First Floor 1.3 M.T.
53 53 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete 1 Nos
54 54 Ground Floor 1.38 cum
55 55 First Floor 1.15 cum
56 56 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. As directed by Engineer-InCharge 1 Nos
57 57 Ground Floor 53.32 sqm.
58 58 First Floor 49.13 sqm.
59 59 Second Floor 1.52 sqm.
60 60 Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with luminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete As directed by Engineer in charge 1 Nos
61 61 Ground Floor 8.64 sqm.
62 62 Providing and fixing Country cut teak wood single leaf panelled door shutters 35 mm thick style and rail and 19 mm thick T.W. panels as per detailed drawing including wrought iron hold fast stainless steel fixtures and fastening and three coats of oil painting etc. complete. 1 Nos
63 63 Ground Floor 32.64 sqm.
64 64 First Floor 35.04 sqm.
65 65 Second Floor 1.89 sqm.
66 66 Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer and Flush bolts complete. 1 Nos
67 67 Ground Floor 2.16 sqm.
68 68 Providing & fixing factory-made steel door of Single leaf Internal Plain Steel finish type with a.) frame of size 100x58 mm conforming to IS : 4351-2003 , 1.2 mm thick pre galvanized sheet with mitred and welded cones , frame stretches, hinge reinforcing plates , fixing plates and hardware mounting plates and Polyurethane foam infill b.) Shutter of thickness 46mm made of 0.8 mm thick slip coated pre galvanized steel sheet on both sides conforming to ASTM A527/ASTM A525, BS 2989 1994, IS 277 , Zinc coating 120 GSM . Lock formed panels with internal stiffeners of 3mm thick made of galvanized sheet, 3 mm thick hinge reinforcing hardware mounting plates and lock protection with Honey-comb craft paper infill of thickness 150 GSM of load bearing capacity 500 Kilogram/Square Metre. c.) Finish: Powder coated surface finished with thermosetting polyurethane paint of Aliphatic grade of thickness 60-micron d.) Accessories: Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges of Dorset make, Dorset cylindrical lock, SS Tower bolt of 200 mm size, Door stopper complete. 1 Nos
69 69 Ground Floor 4.32 sqm.
70 70 Providing and fixing solid core flush door commercial type on single leaf 16 mm thick Bison Panel cement bonded particle Board including Teak wood lipping beading on all four edges without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast,stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats complete. As directed by Engineer in charge.\n 1 Nos
71 71 Ground Floor 3.6 sqm.
72 72 First Floor 3.6 sqm.
73 73 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box As directed by Engineer in charge. 1 Nos
74 74 Ground Floor 50.58 sqm.
75 75 First Floor 40.68 sqm.
76 76 Providing and fixing in position -------------- aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. As directed by Engineer in charge.\n a) Colour anodized 1 Nos
77 77 Ground Floor 87.65 sqm.
78 78 First Floor 92.74 sqm.
79 79 Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dip zinc coating including fabricating glazing with plain / obscured glass panes 5 mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. BD-T-53 Page No. 509 As directed by Engineer in charge. 1 Nos
80 80 Ground Floor 2.3 sqm.
81 81 First Floor 3.06 sqm.
82 82 Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete 1 Nos
83 83 Ground Floor 13.6 Rgm.
84 84 First Floor 61.86 Rgm.
85 85 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Bd.L.1 Page No. 367 1 Nos
86 86 Ground Floor 614.08 sqm.
87 87 First Floor 633.3 sqm.
88 88 Second Floor 43.56 sqm.
89 89 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Bd.L.2 Page No. 368 1 Nos
90 90 Ground Floor 1181.85 sqm.
91 91 First Floor 843.14 sqm.
92 92 Second Floor 43.12 sqm.
93 93 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Bd.L.7 Page No. 369 1 Nos
94 94 Ground Floor 283.37 sqm.
95 95 First Floor 430.71 sqm.
96 96 Second Floor 49.9 sqm.
97 97 Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100%virginmix), sandwiched between two aluminium sheets of ALLOYGRADE-5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4mm, the exposed surface there of shall have Stove lacquered finishing coat not less than (26+-2) micron (containing minimum 70 % kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the buildinge xterior surface) shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting frame work shall be made out of 50mm X 25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900mm X 1200mm and fixed to the building structure as per design through 50mm X 50mm X5mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all these aling of joints to be done with weather sealent Silicon as directed by Engieer-in-charge.(Prior permission of S.E.isnecessary before inclusion of this item in estimate) 1 Nos
98 98 Ground Floor 174.79 sqm.
99 99 First Floor 139.86 sqm.
100 100 Above First Floor 75.43 sqm.
101 101 Providing and fixing copper strip 25mm wide and 3mm thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthinf pits is not considered in this item BdW 1 Page 581 as directed Engineer in Charge 1 Nos
102 102 Ground Floor 120 Rgm.
103 103 First Floor 120 Rgm.
104 104 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Bd. M.22 B/Page No. 390 1 Nos
105 105 Ground Floor 57.61 sqm.
106 106 First Floor 44.2 sqm.
107 107 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. 1 Nos
108 108 Ground Floor 2.7 sqm.
109 109 First Floor 10.07 sqm.
110 110 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. 1 Nos
111 111 Ground Floor 283.08 sqm.
112 112 First Floor 328.8 sqm.
113 113 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete 1 Nos
114 114 Ground Floor 70.2 sqm.
115 115 First Floor 65.97 sqm.
116 116 Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 1 Nos
117 117 Ground Floor 15.84 sqm.
118 118 First Floor 43.68 sqm.
119 119 Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. 1 Nos
120 120 Ground Floor 327.45 sqm.
121 121 First Floor 167.25 sqm.
122 122 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Bd.M. 3 B/Page No. 380 1 Nos
123 123 Ground Floor 159 sqm.
124 124 First Floor 109.75 sqm.
125 125 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Bd.M.12 Page No. 385 1 Nos
126 126 Ground Floor 28.38 sqm.
127 127 First Floor 13.49 sqm.
128 128 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 kg with lid and frame fixed in cement concrete. Bd.V.43, Page No. 574\n 1 Nos
129 129 Ground Floor 15 No
130 130 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Bd.V.38, Page No. 572 1 Nos
131 131 Ground Floor 15 No
132 132 Providing and fixing partition with kadappa stone of all sizes and 25 mm thick polished on both side and edges to original including fixing in position in cement mortor 1:4 curing polish-ing, cleaning etc complete. As directed by Engineer in charge. 1 Nos
133 133 Ground Floor 4.05 sqm.
134 134 First Floor 4 sqm.
135 135 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32 mm size of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia.G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 1 Nos
136 136 Ground Floor 1 No
137 137 First Floor 2 No
138 138 Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Bd.V.30 Page No. 565 1 Nos
139 139 Ground Floor 1 No
140 140 First Floor 2 No
141 141 Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BD.V 5 page 551 and as directed by Engineer in charge 1 Nos
142 142 Ground Floor 20 Rgm.
143 143 First Floor 80 Rgm.
144 144 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BD.V 5 page 551 and as directed by Engineer in charge 1 Nos
145 145 Ground Floor 15 Rgm.
146 146 First Floor 15 Rgm.
147 147 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Bd.V.8 Page No.\n554 1 Nos
148 148 Ground Floor 3 No
149 149 First Floor 6 No
150 150 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. Bd.V.32 Page No.567 1 Nos
151 151 Ground Floor 2 No
152 152 First Floor 3 No
153 153 Providing and fixing 25mm diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete Bd.V. 14 Page No. 557 1 Nos
154 154 Ground Floor 3 No
155 155 First Floor 6 No
156 156 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. As directed by Engineer in charge. 1 Nos
157 157 Ground Floor 1 No
158 158 First Floor 2 No
159 159 Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 NuDrain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. As Directected By Engineer Incharge 1 Nos
160 160 Ground Floor 15 Rgm.
161 161 First Floor 10 Rgm.
162 162 Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 NuDrain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. As Directected By Engineer Incharge 1 Nos
163 163 Ground Floor 70 Rgm.
164 164 Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. As directed by Engineer Incharge 1 Nos
165 165 Ground Floor 50 Rgm.
166 166 First Floor 40 Rgm.
167 167 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. As directed by Engineer in charge. 1 Nos
168 168 Ground Floor 2079.31 sqm.
169 169 First Floor 1907.15 sqm.
170 170 Second Floor 136.58 sqm.
171 171 Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. As directed by Engineer in charge. 1 Nos
172 172 Ground Floor 1181.85 sqm.
173 173 First Floor 843.14 sqm.
174 174 Second Floor 43.12 sqm.
175 175 Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian / Berger / Nerolac / Dulex Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller. (With prior approval of S.E.) 1 Nos
176 176 Ground Floor 1181.85 sqm.
177 177 First Floor 843.14 sqm.
178 178 Second Floor 43.12 sqm.
179 179 Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases (NOx,VOC‘s, CO, SOx, formaldehydes,etc.) in presence of natural or artificial light. It contains Graphene and nano particles of titaniumoxide. and Absorbs CO2 (4.8 Kilogram /15l). plaster crack should be filled by Acrylic base Crack seal / Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned company technologist. 1 Nos
180 180 Ground Floor 283.37 sqm.
181 181 First Floor 430.71 sqm.
182 182 Second Floor 49.9 sqm.
183 183 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Bd.O.5 Page No. 405\n 1 Nos
184 184 Ground Floor 207.44 sqm.
185 185 First Floor 160.8 sqm.
186 186 Second Floor 3.78 sqm.
187 187 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 1 Nos
188 188 Ground Floor 30.37 sqm.
189 189 First Floor 603.4 sqm.
190 190 Second Floor 53.14 sqm.
191 191 Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to with stand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 micron sand should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breath ability property and should be able to cover hairline cracks in the surface up to 0.5 mm The paint has to be applied on a coat of high quality acrylic co polymer based alkali resistant primer with excellent penetrating properties including cleaning, with all lead sand lifts at all levels etc complete, as directed by Engineer in charge. 1 Nos
192 192 Ground Floor 30.37 sqm.
193 193 First Floor 603.4 sqm.
194 194 Second Floor 53.14 sqm.
195 195 Providing and fixing Kumin sensor fauset with Kinesis Technology- cold (DC) with Item Code 18656IN-ND-CP 1 Nos
196 196 Ground Floor 1 No
197 197 First Floor 2 No
198 198 TOTAL OF B 1 Total
199 199 C. PLOT DEVELOPMENT 1 Nos
200 200 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Bd.A.1 Page No. 259 207.71 cum
201 201 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Manual Means Bd.A.1 Page Number 259 79.2 cum
202 202 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Bd.A.10 Page Number 262 71.73 cum
203 203 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Bd.A. 12 Page No. 264 41.71 cum
204 204 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd. E. 1 Page No. 287 50.56 cum
205 205 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.3 Page No. 298 and B.7, Page No.38\n\n\n 24.75 cum
206 206 Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA CD 8 Page 163 37.37 cum
207 207 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.5 Page No. 300 and B.7, Page.No. 38 20.05 cum
208 208 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.6 Page No. 300 and B.7, Page No.38 14.31 cum
209 209 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:6 in super structure including striking joints, raking out joints, watering and scaffolding etc. Complete 78.92 cum
210 210 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Bd.A.11 Page No. 263 47.29 cum
211 211 Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.E. 3/Page No. 288/I.S. 456 (2000) 5.98 cum
212 212 Providing and laying Cast in situ/ Ready Mix cement concrete in M15 of trap /granite /quartzite /gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mixplant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.E.2 Page Number 288 and B.7 Page No 38 7.19 cum
213 213 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.8 Page No. 302 and B.7, Page No.38 18.98 cum
214 214 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page No. 306 \n 8.72 M.T.
215 215 Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. 28.76 sqm.
216 216 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Bd.L.7 Page No. 369 965.82 sqm.
217 217 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Bd. M.22 B/Page No. 390 85.47 sqm.
218 218 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary 965.82 sqm.
219 219 Providing and erecting Y type barbed wire fencing with seven row sofwire with 2.45mm dia G.I. pipe ( Rezan/ concentiDeleted ire 0.75 mm dia ) with hot dip and G.I. coated hooks as per drawing supported on M.S. angle 50x50x6 mm at 2.5mtr. c/c including fixing and fastening with wire,painting M.S.angles with one coat of red lead primer and two coat of oil paint etc. complete. As directed by Engineer in charge. 172.53 Rgm
220 220 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.E.4 Page No. 289 and B-7, Page No.38 2.76 cu.m
221 221 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and desig 22 +/-2 mm thick bayer colour pigmented as per IS..1237-1980 having compressive strength more than 500 Kilogram / sq.cm reaffirmed in 2006, having wert transvrse strenghth of 3.5 / mm2, water absorption less than 10% abrasion / wear resistance less than 2mm, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN-51094 of size 300x300 in plan / designed pattern on abed of 1:4 cement mortar including cement float, filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 637.22 sqm.
222 222 Garden soil :- Supplying on site garden soil well sieved 90 % to pass through I.S. Sieve of 10 mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry . The colour of the soil generally be red . The soil will be measured by measuring box. ( Farma ) ( Item includes Royalty charges Corration Tax , Transporatation , loading , unloading etc. ) 22 cu.m
223 223 Preparing instant Lawn :- Excavating the ground to a required depth of 20 cms, removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/ silt & manure in excavated area in 3:1 proportion to a height of 20 cms. Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling, etc. complete. 40 sqm.
224 224 Farm yard manure :-\nSupplying on site well decayed, well dried, well powered, without clouds and free from stones, dried grass and other rubbish material. The color of the manure generally is black. The manure will be measured by measuring box. (Farma) Item inculdes, transporting, loading-unloading etc. (lead charges per 10 km. are considered.)\n 5 cu.m
225 225 Mixing garden soil / silt & manure in excavated area including lead upto a distance of 50 mtrs (1.10 of unskilled abour)\n 50 sqm.
226 226 Providing following plants … etc complete.\n 1 Nos
227 227 Saplings of flowering / shady trees, Gulmohar, Raintree, Peltophorum etc. in polybag (ht. upto 2-2.5 mtr.) 100 No.
228 228 Roses common / buddes varities 50 No.
229 229 Mogra / Creeper / climbers 50 No.
230 230 Canna Ryzome common varieties 50 No.
231 231 Rooted /Unrooted cutting for hedge plants (in small poly bag) 50 No.
232 232 TOTAL OF C 1 Total
233 233 D. PROPOSED WORK 1 Nos
234 234 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Bd.A.1 Page No. 259 441.74 cum
235 235 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Manual Means Bd.A.1 Page Number 259 294.495 cum
236 236 Providing preconstructional anti termite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. 709.895 sqm.
237 237 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Bd.A.10 Page Number 262 184.06 cum
238 238 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Bd.A. 12 Page No. 264 152.68 cum
239 239 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd. E. 1 Page No. 287 90.2 cum
240 240 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.3 Page No. 298 and B.7, Page No.38\n\n\n 154.465 cum
241 241 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.5 Page No. 300 and B.7, Page.No. 38 1 Nos
242 242 Ground Floor 40.69 cum
243 243 First Floor 30.14 cum
244 244 Above First Floor 5.94 cum
245 245 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.6 Page No. 300 and B.7, Page No.38 1 Nos
246 246 Ground Floor 33.82 cum
247 247 First Floor 39.41 cum
248 248 Above First Floor 22.46 cum
249 249 Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. As director by engineer in charge and BDG- 2 and 5 1 Nos
250 250 Ground Floor 2.66 cum
251 251 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Bd.A.11 Page No. 263 1 Nos
252 252 Ground Floor 80.37 cum
253 253 Providing preconstructional anti termite treatment as per I.S.6313(Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. 1 Nos
254 254 Ground Floor 428.86 sqm.
255 255 Providing Auto claved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part3)-1984 in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc.Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) 1 Nos
256 256 Ground Floor 62.78 cum
257 257 First Floor 89.35 cum
258 258 Above First Floor 26.17 cum
259 259 Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.E. 3/Page No. 288/I.S. 456 (2000) 1 Nos
260 260 First Floor 1.65 cum
261 261 Above First Floor 2.24 cum
262 262 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.8 Page No. 302 and B.7, Page No.38 1 Nos
263 263 Ground Floor 20.42 cum
264 264 First Floor 50.18 cum
265 265 Above First Floor 31.71 cum
266 266 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Bd.C.2 Page No. 275 1 Nos
267 267 First Floor 1.55 M.T.
268 268 Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 kg/sq.m.). Bd.R.5, Page No. 453 1 Nos
269 269 First Floor 110.97 sqm.
270 270 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Bd.F.9 Page No. 303 and B.7, Page No.38 1 Nos
271 271 Ground Floor 2.62 cum
272 272 First Floor 2.41 cum
273 273 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page No. 306 \n 1 Nos
274 274 Ground Floor 24.49 M.T.
275 275 First Floor 14.38 M.T.
276 276 Above First Floor 6.64 M.T.
277 277 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. As directed by Engineer-InCharge 1 Nos
278 278 Ground Floor 30.86 sqm.
279 279 First Floor 30.98 sqm.
280 280 Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25 mm thick panels with openable fan light as per detailed drawings. Excluding the door frame 60mm x 100mm stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame) BD-T-7 and 8 Page No. 481-82 1 Nos
281 281 Ground Floor 9.12 sqm.
282 282 First Floor 9.12 sqm.
283 283 Providing and fixing solid core flush door commercial type on single leaf 16 mm thick Bison Panel cement bonded particle Board including Teak wood lipping beading on all four edges without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast,stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats complete. As directed by Engineer in charge.\n 1 Nos
284 284 Ground Floor 14.4 sqm.
285 285 First Floor 18 sqm.
286 286 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box As directed by Engineer in charge. 1 Nos
287 287 Ground Floor 20.52 sqm.
288 288 First Floor 28.62 sqm.
289 289 Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dip zinc coating including fabricating glazing with plain / obscured glass panes 5 mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. BD-T-53 Page No. 509 As directed by Engineer in charge. 1 Nos
290 290 Ground Floor 6.885 sqm.
291 291 First Floor 7.65 sqm.
292 292 Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.\nBd.U.1 Page No. 537 1 Nos
293 293 Ground Floor 20.52 sqm.
294 294 First Floor 15.66 sqm.
295 295 Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete 1 Nos
296 296 Ground Floor 1.8 Rgm.
297 297 First Floor 1.8 Rgm.
298 298 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Bd.L.1 Page No. 367 1 Nos
299 299 Ground Floor 147.93 sqm.
300 300 First Floor 370.555 sqm.
301 301 Above First Floor 225.96 sqm.
302 302 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Bd.L.2 Page No. 368 1 Nos
303 303 Ground Floor 358.22 sqm.
304 304 First Floor 728.62 sqm.
305 305 Above First Floor 88.96 sqm.
306 306 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Bd.L.7 Page No. 369 1 Nos
307 307 Ground Floor 290.66 sqm.
308 308 First Floor 295.88 sqm.
309 309 Above First Floor 109.84 sqm.
310 310 Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Bd.L.4 Page No. 368\n 1 Nos
311 311 Ground Floor 37.02 sqm.
312 312 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. 1 Nos
313 313 Ground Floor 70.68 sqm.
314 314 First Floor 77.22 sqm.
315 315 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. Bd. L.10, Page No.370 1 Nos
316 316 Ground Floor 358.22 sqm.
317 317 First Floor 728.62 sqm.
318 318 Above First Floor 88.96 sqm.
319 319 Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete 1 Nos
320 320 Ground Floor 70.2 sqm.
321 321 First Floor 76.74 sqm.
322 322 Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete 1 Nos
323 323 Ground Floor 181.85 sqm.
324 324 First Floor 156.26 sqm.
325 325 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. 1 Nos
326 326 Ground Floor 56.7 sqm.
327 327 First Floor 292.79 sqm.
328 328 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete 1 Nos
329 329 Ground Floor 3.42 sqm.
330 330 First Floor 11.17 sqm.
331 331 Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. 1 Nos
332 332 Ground Floor 4.6 sqm.
333 333 First Floor 4.6 sqm.
334 334 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Bd.M. 3 B/Page No. 380 1 Nos
335 335 Ground Floor 10.66 sqm.
336 336 First Floor 9.67 sqm.
337 337 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Bd.M.12 Page No. 385 1 Nos
338 338 Ground Floor 7.51 sqm.
339 339 First Floor 12.55 sqm.
340 340 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 kg with lid and frame fixed in cement concrete. Bd.V.43, Page No. 574\n 1 Nos
341 341 Ground Floor 5 No
342 342 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Bd.V.38, Page No. 572 1 Nos
343 343 Ground Floor 5 No
344 344 Providing and fixing partition with kadappa stone of all sizes and 25 mm thick polished on both side and edges to original including fixing in position in cement mortor 1:4 curing polish-ing, cleaning etc complete. As directed by Engineer in charge. 1 Nos
345 345 Ground Floor 16.34 sqm.
346 346 First Floor 16.34 sqm.
347 347 Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. As directed by Engineer in charge. 1 Nos
348 348 Ground Floor 9 No
349 349 First Floor 10 No
350 350 Providing and fixing KOHLER-Patio Urinal with Integrated Sensor with Item Code 16321IN-SS-0 1 Nos
351 351 Ground Floor 5 No
352 352 First Floor 5 No
353 353 Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Bd.V.30 Page No. 565 1 Nos
354 354 Ground Floor 9 No
355 355 First Floor 10 No
356 356 Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BD.V 5 page 551 and as directed by Engineer in charge 1 Nos
357 357 Ground Floor 30 Rgm.
358 358 First Floor 100 Rgm.
359 359 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. BD.V 5 page 551 and as directed by Engineer in charge 1 Nos
360 360 Ground Floor 50 Rgm.
361 361 First Floor 50 Rgm.
362 362 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Bd.V.8 Page No.\n554 1 Nos
363 363 Ground Floor 24 No
364 364 First Floor 24 No
365 365 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. Bd.V.32 Page No.567 1 Nos
366 366 Ground Floor 14 No
367 367 First Floor 14 No
368 368 Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Bd.V.46, Page No. 576 1 Nos
369 369 Ground Floor 1 No
370 370 Providing and fixing 25mm diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete Bd.V. 14 Page No. 557 1 Nos
371 371 Ground Floor 24 No
372 372 First Floor 24 No
373 373 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. As directed by Engineer in charge. 1 Nos
374 374 Ground Floor 7 No
375 375 First Floor 7 No
376 376 Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 NuDrain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. As Directected By Engineer Incharge 1 Nos
377 377 Ground Floor 20 Rgm.
378 378 First Floor 24 Rgm.
379 379 Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 NuDrain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. As Directected By Engineer Incharge 1 Nos
380 380 Ground Floor 25 Rgm.
381 381 Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. As directed by Engineer Incharge 1 Nos
382 382 Ground Floor 50 Rgm.
383 383 First Floor 40 Rgm.
384 384 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.\nAs directed by Engineer in charge. 1 Nos
385 385 Ground Floor 3 Rgm.
386 386 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. As directed by Engineer in charge. 1 Nos
387 387 Ground Floor 796.8 sqm.
388 388 First Floor 1395.1 sqm.
389 389 Above First Floor 424.76 sqm.
390 390 Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulex Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10% or water by 15 to 20% allowing to dry for 6 to 8 hours After applying Asian/ Berger/ Nerolac/ Dulex Paints or equivalent acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70% by roller. (With prior approval of S.E.) 1 Nos
391 391 Ground Floor 358.22 sqm.
392 392 First Floor 728.62 sqm.
393 393 Above First Floor 88.96 sqm.
394 394 Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases (NOx,VOC‘s, CO, SOx, formaldehydes,etc.) in presence of natural or artificial light. It contains Graphene and nano particles of titaniumoxide. and Absorbs CO2 (4.8 Kilogram /15l). plaster crack should be filled by Acrylic base Crack seal / Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned company technologist. 1 Nos
395 395 Ground Floor 290.66 sqm.
396 396 First Floor 295.88 sqm.
397 397 Above First Floor 109.64 sqm.
398 398 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Bd.O.5 Page No. 405\n 1 Nos
399 399 Ground Floor 74.45 sqm.
400 400 First Floor 77.55 sqm.
401 401 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres As directed by engineer-incharge. 1 Nos
402 402 First Floor 5000 Lit.
403 403 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 1 Nos
404 404 First Floor 165.83 sqm.
405 405 Above First Floor 233.38 sqm.
406 406 RWH - Recharge Pit Providing and constructing recharge pit of 2.0 m deep and 1.0 m dia of pre-cast RCC rings with 6.5" dia x 25 m deep bore well at the floor of recharge pit including installation of combination of solid / perforated PVC casing pipe wrapped around with netlon mesh including 300 mm thick side filling around outside of RCC rings (annular space) with 40 mm size boulders including filling of recharge pit up to 0.5 m depth with 25-75 mm clean washed gravels from bottom up followed by 0.5 m depth of 10-25 mm of clean washed stones followed by 0.5 m of washed river fine aggregate (naturalsand /crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel / fine aggregate (naturalsand /crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & back filling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, 1 Nos
407 407 Ground Floor 1 No.
408 408 Providing and fixing Kumin sensor fauset with Kinesis Technology- cold (DC) with Item Code 18656IN-ND-CP 1 Nos
409 409 Ground Floor 9 No
410 410 First Floor 10 No
411 411 TOTAL OF D 1 Total
412 412 MATERIAL TESTING 1 Nos
413 413 Material: Cement 1 Nos
414 414 Test: Standard Consistancy Fineness, Specific Gravity, Setting Time (Initial & Final), Compressive strength, Soundness. 1 No.
415 415 Material: Coarse Aggregate 1 Nos
416 416 water absorption, Specific Gravity, Impact Value & Crushing Value test will have to carry out in addition. 1 No.
417 417 Sieve Analysis 1 No.
418 418 Abrasion Value 1 No.
419 419 Material: Fine Aggregate (Sand) 1 Nos
420 420 Fineness Modulus (Sieve Analysis), Silt & Clay Content 1 No.
421 421 Material: Concrete 1 Nos
422 422 Test: Compressive Strength for M-20 Grade concrete of Min. 7 days of Curing with Min. No. of Sample as per Qty. of 50 Cu.M For 4 or Part thereof. 3 No.
423 423 Concrete Mix Design\n(With all Tests on basic materials) 1 No.
424 424 Material: Steel Bar Testing 1 Nos
425 425 Up to 16 mm ( set of 3 bars ) 4 No.
426 426 Material: Bricks 1 Nos
427 427 water absorption ( set of 5 bricks ), compressive strength ( set of 5 bricks ), Efflorescance ( set of 5 bricks ) 1 No.
428 428 Material: Mortor 1 Nos
429 429 Compressive strength ( set of 3 cubes) 1 No.
430 430 Material: Stone/Rubble 1 Nos
431 431 Crushing Value/ Compressive strength water\nAbsorption & specific Gravity 1 No.
432 432 Material:Wood 1 Nos
433 433 Density, Moisture content 1 No.
434 434 Material: Ceramic Tiles / Vitrified Tiles 1 Nos
435 435 water absorption ( set of 6 tiles ), flexural test ( set of 6 tiles ). 1 No.
436 436 Material: Aluminium Section 1 Nos
437 437 Thickness, Mass per Running meter of aluminuim section 1 No.
438 438 Test on powder coating 1 No.
439 439 Material: P.V.C.Pipes 1 Nos
440 440 Weight per running meter,\nDiameter of pipe & wall thickness of pipe 1 No.
441 441 TOTAL FOR MATERIAL TESTING 1 Total
442 442 E. ELECTRIFICATION 1 Nos
443 443 Supplying & erecting HMS PVC conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 1500 m
444 444 Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 1000 m
445 445 Supplying & erecting HMS PVC conduit 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 200 m
446 446 Supplying & laying HMS PVC conduit 32 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.. 100 m
447 447 Supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm FR PVC copper wire, in HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC. 6000 m
448 448 Supplying & erecting mains with 2x4 sq.mm. and earth wire 2.5 sq.mm FR PVC copper wire in HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC. 300 m
449 449 Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. 115 Each
450 450 Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete. 115 Each
451 451 Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 65 Each
452 452 Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. 30 Each
453 453 Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW 449 Point
454 454 Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WGPW/SW 458 Point
455 455 Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW 180 Point
456 456 Supplying & erecting telephone copper cable 2 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW 3500 m
457 457 Supplying & erecting jelly filled unarmoured telephone cable 100 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW 100 m
458 458 Supplying, erecting & commissioning MDF Box 150 x 150 pairs\nas per specification No. WG-TW 1 Each
459 459 Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete. 1 Job
460 460 Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC 4500 m
461 461 Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC 115 Each
462 462 Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP 5 Each
463 463 Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. 230 Each
464 464 Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070mm) as per specification No. WG-NAS/RAK 1 Each
465 465 Supplying and erecting LED square 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 60 Each
466 466 Supplying and erecting LED square 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 64 Each
467 467 Supplying and erecting LED circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 99 Each
468 468 Supplying and erecting LED circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 110 Each
469 469 Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete. 60 Each
470 470 Supply & Installation of 5W LED COB downlight fixtures as of Wipro make cat no. D810565 (Garnet) 66 Each
471 471 Supply & Installation of 30W LED Pendent Light with Aluminium Body Powder Coated as of wipro make cat. no. LD30-301-36W-40-PS 9 Each
472 472 Supplying and erecting LED mirror light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete. 13 Each
473 473 Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete. 14 Each
474 474 Supplying and erecting LED flexible strip light 5m length upto 25W conforming IP 65 of any colour with driver complete. 28 Each
475 475 Supplying and erecting rectangular shaped CRCA /die-cast aluminium powder coated housing LED panel (slim edge-lit) 300x1200mm of suitable for 36 to 40 W with provision for plane front frame with translucent cover fixed to the housing complete. 10 Nos.
476 476 Supplying and erecting cylindrical shaped integral decorative with high power 12W-16W LED bollard upto 1000mm with opal acrylic diffuser and IP65 protection on provided foundation complete. 4 Nos.
477 477 Supplying and erecting 40W LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 protection on provided pole/ bracket. 2 Nos.
478 478 Supplying and erecting Gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED lamp on provided pipe as per specification No. FG-ODF/GLT 2 Nos.
479 479 Supplying and erecting LED street light fitting suitable above 26W to 36W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FGODF/ FLS2. 8 Nos.
480 480 Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and =E‘ class insulation. 22 Each
481 481 Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF 65 Each
482 482 Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB 174 Each
483 483 Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB 1 Each
484 484 Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB 6 Each
485 485 Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 24 poles on iron / GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 3 Each
486 486 Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 36 poles on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 3 Each
487 487 Supplying and erecting single pole and neutral distribution board\n(SPNDB) surface/flush mounted with 2 poles for incoming and\n6 poles for outgoing SP MCB?s on iron/ GI frame as per\nspecification no. SW-SWR/MCBDB 1 Each
488 488 Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 60 m
489 489 Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 260 m
490 490 Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 20 m
491 491 Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 70 m
492 492 Supplying, erecting & terminating XLPE armoured cable 3½ core\n240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 170 m
493 493 Supplying, erecting & terminating XLPE armoured cable 4 core 6\nsq. mm. aluminium conductor with continuous 5.48 sq. mm. (12\nSWG) G.I. earth wire complete erected with glands & lugs, on wall/\ntrusses/pole or laid in provided trench/ pipe as per specification no.\nCB-LT/AL 50 m
494 494 Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 390 m
495 495 Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 60 m
496 496 Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories. 30 m
497 497 Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. 50 m
498 498 Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. 450 m
499 499 Supplying and fixing of cable trunking/race ways (200mm x 50mm) of sheet steel 14 gauge complete with removable covers, right angles and 145 degree bends, adapters tee pieces, couplers ,Junction boxes etc. all as per specifications / drawings. 130 m
500 500 Providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OHPL/ OPL. 2 Each
501 501 Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OHPL/ OPL 8 Each
502 502 Providing earthing with galvanized iron earth plate size 60 x 60 x0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP 27 Each
503 503 Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA 4 Each
504 504 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 500 Kg.
505 505 Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner. 200 Kg.
506 506 Main LT Panel \nIncoming (Transformer)\n500 Amps, 415 Volts, 4 Pole, 50Hz, MCCB 36KA, MP Based with Rotary Handle Lsig protection\nBus bars\n1 Set of 500 Amps, 415 Volts, 50 Hz, 3 phase, 4 wire colour coded 5Al. bus bars.\nInstruments\n1 No 0-500 Volts, Digital voltmeter with built in selector switch and protection fuses.\n1 No 0-500 Amps, Digital ammeter with built in selector switch and 5matching CT's .\n1 Set of RYB phase indicating lamps (LED).\n1 Set red & green (ON, OFF) indicating lamps (LED) for incomer. \n1 Set of multification KWH meter (Suitable CT/PT)\nIncoming (DG)\n500 Amps, 415 Volts, 4 Pole, 50Hz, MCCB 36KA, MP Based with Rotary Handle Lsig protection\nBus bars\n1 Set of 500 Amps, 415 Volts, 50 Hz, 3 phase, 4 wire colour coded 5Al. bus bars.\nInstruments\n1 No 0-500 Volts, Digital voltmeter with built in selector switch and protection fuses.\n1 No 0-500 Amps, Digital ammeter with built in selector switch and 5matching CT's .\n1 Set of RYB phase indicating lamps (LED).\n1 Set red & green (ON, OFF) indicating lamps (LED) for incomer. \n1 Set of multification KWH meter (Suitable CT/PT)\nOutgoing\n01 Nos. 250 FP MCCB \n02 Nos. 160 FP MCCB \n02 Nos. 63A FP MCB. \n01 Nos. 50A FP MCB. \n03 Nos. 40A FP MCB. \n01 Nos. 32A FP MCB. \n01 Nos. 63A FP MCB Spares\n01 Nos. 40A FP MCB Spares\n02 Nos. Vaccant\n 1 Nos.
507 507 CAPACITOR PANEL (90 KVAR) \nIncoming\n01 Nos. 160 Amps, TPN MCCB 25 KA\nBus bar\n1 set of 160 Amps, 415 volts, 50 Hz, 3 phase, 4 wire colour coded aluminium bus bars. \nOutgoing\n02 Nos. 63 Amps, TP MCB with isolable neutral\n03 Nos. 50 Amps, TP MCB with isolable neutral\n02 Nos. 32 Amps, TP MCB with isolable neutral\n02 Nos. 25 KVAR 3 phase 415 V capacitor \n03 Nos. 10 KVAR 3 phase 415 V capacitor \n02 Nos. 5 KVAR 3 phase 415 V capacitor \n1 set red & green (on/off) indication for each contactor.\nSets on/off push buttons for manual operation \n1 No. 12-14 stage APFCR and allied control wiring in-built power factor meter.\n1 No. automanual selector switch.\n 1 Nos.
508 508 Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. 4 Each
509 509 Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete. 2 Each
510 510 Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge andage,\nmedicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) 1 Each
511 511 Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 kV 5 m2
512 512 Supplying & erecting on line UPS pure sine wave of 10 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS 2 Set
513 513 Supply Installation, testing & commissining of Indoor type HD Dome Camera with 1/2" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8mm Fixed lens, 1080 P Highfinition, Inbuilt Smart IR LED upto 20m distance, True Day / Night Vision, with Junctionbox & required accessories. 38 No.
514 514 Supply Installation, testing & commissining of Indoor type HD Bullet Camera with 1/2" 2 Mega Pixel progressive CMOS Sensor, integrated 2.8mm Fixed lens, 1080 P Highfinition, Inbuilt Smart IR LED upto 20m distance, True Day / Night Vision, with Junctionbox & required accessories. 18 No.
515 515 Supply, installation, testing & commissioning of 32 Channel Digital Video Recorder (DVR) with Support smultiple video stream, 1HDMI & 1VGA output, Upto 4 SATA Interfaces, Multi Users Simultaneouse access, should have recording resolution of 25fps@ 1080P and H.265 for30days, including required accessories. 2 Nos.
516 516 Supply, installation, testing & commissioning of 6TB Surveillance Hard Disk suitable for CCTV recording with required accessories. 4 Nos.
517 517 Supply, installation, testing & commissioning of Wall mount 32" FHD Flat LED TV for CCTV monitoring (Professional 24x7 operation) having 1 VGA & 2 HDMI port, 2 USB port with wall mount accessories. 2 Nos.
518 518 Supply, installation, testing & commissioning 20 AMP 16 Channel Power Supply 4 Nos.
519 519 Supply & installation of 15U 600 x 550 mm Wall mount Rack with Front Glass Door, Fan TrayonTop, Perforated Rear Doors, Openable Entry at the Bottom for the Cableentry, Cable Basket for Cable Dressing & Vertical Power Strip with all necessary accessories & hardware. 1 Nos.
520 520 Supply & installation, testing & commissioning 3+1 Cu. cable including both side crimping & end termination. 1780 Mtr.
521 521 TOTAL OF E 1 Total
522 522 F. HVAC 1 Nos
523 523 Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1 TR having ISEER minimum 4.50 suitable to operate on capacity 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall / floor mounting type complete with refrigerant R410A/R32 and copper condenser at position. specification no. APAC/SAC 7 Each
524 524 Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity having ISEER\nminimum 4.50 suitable to operate on250V, 50 cycles, A.C. supply having 1 no of air handling unit hiwall / floor mounting type complete with refrigerant R410 A/R32 and copper condensor at position. specification no.APAC/ SAC 16 Each
525 525 Supplying, installing, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity having ISEER\nminimum 4.50 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A /R32 and copper condenser at position. specification no. APAC/ SAC 15 Each
526 526 Supplying, installing, testing and commissioning split type room Air ditioning unit with variable speed Inverter technology 2.5 TR capacity with R410A/R32\nrefrigerant & copper condenser suitable to operate on 230/415V, 50cycles, A.C. supply having 1 no. of air handling unit (Mega spilt) Hi-wall mounting type\ncomplete at position. specification no. AP-AC/SAC 4 Each
527 527 Supplying, installing, testing and commissioning split type room Air conditioning unit 3TR capacity with R410A/R32 refrigerant, 415 V, 50 cycles, A.C. supply having 1 no. of air handling unit (Mega spilt) mounting type complete at position. Specification no. AP-AC/SAC 4 Each
528 528 Supply, installation, testing and commissioning cordless remote contol having colour LCD panel, real time clock, temperature limitation (16 to 30 degree Cent.), functions like filter clean reminder timer suitable to communicate with wired controller complete. 46 Each
529 529 Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with\napplication of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV /\nVRF air conditioning system. 100 m
530 530 Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. 100 m
531 531 Supplying & erecting HMS PVC conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 170 m
532 532 Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as per specification No: WGPW/SW 46 Point
533 533 Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB 60 Each
534 534 Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB 1 Each
535 535 Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW- WR/MCCB 1 Each
536 536 Supplying & erecting mains with 2x4 sq.mm. and earth wire 2.5 sq.mm FR PVC copper wire in HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC. 1680 m
537 537 Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 24 poles on iron / GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 1 Each
538 538 Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1 1 Each
539 539 Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 60 m
540 540 TOTAL OF F 1 Total
541 541 G-FIRE FIGHTING 1 Nos
542 542 Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete. 3 Each
543 543 Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. 20 Each
544 544 Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 1400 LPM at 56 m head centrifugal type, 30 HP (22 kW), 3 phase, 415 volt, 50Hz or of suitable HP complete, as per specification no. FF-MFP/SSC 2 Each
545 545 Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 76/105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP 1 Each
546 546 Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 450 LPM at 35 m head 7.5 HP (5.5 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP 1 Each
547 547 Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/ PG 3 Each
548 548 Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS 3 Each
549 549 Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV 2 Each
550 550 Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT 1 each
551 551 Supplying and erecting cast iron foot valve ball type/flap type of size 100 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV 1 Each
552 552 Supplying and erecting cast iron foot valve ball type/flap type of size 150 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV 2 Each
553 553 Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV 1 Each
554 554 Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV 1 Each
555 555 Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV 2 Each
556 556 Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV 3 Each
557 557 Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV 2 Each
558 558 Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV 2 Each
559 559 Supplying and erecting G.I. pipe above ground of „C? class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP 6 m.
560 560 Supplying and erecting G.I. pipe above ground of „C? class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP 6 m.
561 561 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 80 mm dia with necessary fittings as per specification No. FFPP 6 m.
562 562 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings as per specification no. FFPP 12 m.
563 563 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings as per specification no. FFPP 12 m.
564 564 Electrical \nFire Pump Panel (Electrical)\nSupplying, erecting, testing and commissioning cubicle pattern electrical control panel made of 14 SWG MS Sheet duly painted with enamel paint, comprising of the following:\nIncoming\n1 No, 160 Amps FP MCCB (25 KA)\nBus bars\n1 Set 3 Phase, 4 wire busbar 160 Amps Aluminium conductor, duly sleeved in PVC colour coded sleeves.\nOutgoings\n2 Nos 100 A TP MCCB withneutral link (25 KA)\n1 Nos 63 A TP MCCB with neutral link (25 KA)\n2 No. Star Delta starter with overload relay suitable for 50 HP.\n1 No. Dol starter with overload relay suitable for 20 HP.\nMetering\n1 Set RYB phase indication lamps with toggle suitable and protection fuses.\n1 No. 0-500 volts, 96mm square with with MCB.\n1 No. 0-160 Amps Ammeter of 96mm square with CT's\n1 No. 96sqmm energy meter with CT's\nPanel shall be run in such a fshion that in normal condition jockey pump shall be started in case there is further drop in pressure Main Pump will be ON and even after starting of Main Pump pressure is not getting develop then DG-1 Should be ON.Both DG pump shall have facility to run in Normal power availibility condition as well power failure.\n 1 Each
565 565 Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 40 m.
566 566 Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 20 m.
567 567 Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV 9 Each
568 568 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV 4 Each
569 569 Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL 18 Each
570 570 Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ 9 Each
571 571 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box\nred colour. 9 Each
572 572 Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 160 mm outer dia and required/proper diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP 9 each
573 573 Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC 2 Each
574 574 Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV 1 Each
575 575 Supplying & Installing cast iron double flange butterfly valve of size 150 mm dia. as per specification No. FF-VL/BFV 2 each
576 576 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 80 mm dia with necessary fittings as per specification No. FFPP 12 m.
577 577 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings as per specification no. FFPP 60 m.
578 578 Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings as per specification no. FFPP 170 m.
579 579 Supply, erection, testing and commissioning of Intelligent Microprocessor controlled networkable Addressable type 4 Loop Fire Alarm Control Panel with capable of handling 150 detectors and devices per loop, located Reception / Control room. Panel should have alarm facilities, hooter, fire / fault indicators, audio video signals, battery, battery charger, central processing unit, network integrator module, power supply, independent time delay circuits for MCP actuated alarms and also for detector actuated alarms, etc., complete in all respects as per detailed specifications. Panel shall be capable to run on computer system with integration of RS-485 for display and monitoring 1 each
580 580 Supply, erection, testing & commissioning of Analogue Addressable type Optical Smoke Detectors with dual chamber, solid state design, visible LED indicating lamps for operational status, mounting base, etc., as per detailed specification. 101 each
581 581 Supply, erection, testing & commissioning of Analogue Addressable type wall / ceiling mountable Electronic Hooters with bell control module etc. as per specification. 8 each
582 582 Supply, erection, testing & commissioning of Analogue Addressable resettable type with key for normalising type Manual Call Point as per the detailed specifications. 8 each
583 583 Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/ CU 950 each
584 584 Digital Flex Board, Flex Printing (4 Pass) with MS Pipe Frame, Sticker Indicating location of Fire Extinguisher, Hydrants, Hose Reel, Fire Exit and also Safety Instructions (Size - 1ft. X 1.5ft.) 30 Each
585 585 Layout Plan of Fire Fighting System Digital Flex Board, Flex Printing (4 Pass) with MS Pipe Frame, Sticker] 1 Each
586 586 TOTAL OF G 1 Total
587 587 TOTAL OF A+B+C+D+E+F+G 1 Total
588 588 H-ROYALTY 1 Total
589 589 I-MATERIAL TESTING 1 Total
590 590 J-INSURANCE 1 Total
591 591 TOTAL OF A+B+C+D+E+F+G & INSURANCE 1 Total
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail