Repair / Maintenance Of Dg Sets And Connected Items At Cme-1 Maintenance And Servicing Of Dg Sets Once In A Month Including Attending Faults On Call Basis For Normal Repairs Including Replacement Of Defective & Worn Out Parts By New Spares Such As Filters, Gaskets, V Belts, Engine Oil, Rubber Hoses, Worm Drive Clamps, Nut Bolts And Cleaning Of Alternator With Vaccum Cleaner And Attending Faults Of Amf Panels Etc And Greasing Of Bearings Of Engine And Alternator, Checking Of Batteries, Adding Distilled Water, Checking Of Oil And Coolant Levels As Directed By Engineer-In Charge. N [ Note : I ) Spares Required For Above Maintenance Will Be Measured And Paid Separately Under Relevant Item. ( Ii ) Servicing To Be Carried Out As Per Manufacturer Instruction ] 2 ( A ) Dg Set 12.5 Kva Capacity, Location : Ini N 3 ( B ) Dg Set 15 Kva Capacity, Location : Bd Coy 4 ( C ) Dg Set 15 Kva Capacity, Location : Map Pump House 5 ( D ) Dg Set 15 Kva Capacity, Location : Shivaji Colony Sewage Pump House 6 ( E ) Dg Set 20 Kva Capacity, Location : Medical Dental Centre 7 ( F ) Dg Set 25 Kva Capacity, Location : 454 Pump House 8 ( G ) Dg Set 50 Kva Capacity, Location : Fnbcp 9 ( H ) Dg Set 62.5 Kva Capacity, Location : Fe E / M ( Work Shop Building ) 10 ( J ) Dg Set 62.5 Kva Capacity, Location : Fe E / M ( Work Shop Building ) 11 ( K ) Dg Set 62.5 Kva Capacity, Location : Fe E / M ( Work Shop Building ) 12 ( L ) Dg Set 62.5 Kva Capacity, Location : Fe E / M ( Work Shop Building ) 13 ( M ) Dg Set 62.5 Kva Capacity, Location : Pump / Power House No 7 14 ( N ) Dg Set 63 Kva Capacity, Location : Fnbcp 15 ( O ) Dg Set 63 Kva Capacity, Location : Fnbcp 16 ( P ) Dg Set 100 Kva Capacity, Location : Fnbcp 17 ( Q ) Dg Set 100 Kva Capacity, Location : Rowing Channel 18 ( R ) Dg Set 100 Kva Capacity, Location : It Wing 19 ( S ) Dg Set 100 Kva Capacity, Location : Main Hq Bldg Cme 20 ( T ) Dg Set 125 Kva Capacity, Location : Sewage Treatment Plant 21 ( U ) Dg Set 160 Kva Capacity, Location : Diploma Wing 22 ( V ) Dg Set 200 Kva Capacity, Location : Bhosari Pump House 23 ( W ) Dg Set 250 Kva Capacity, Location : Ctw 24 ( X ) Dg Set 320 Kva Capacity, Location : Gis Building 25 Supply Only Diesel Filter Element With O Ring, Suitable For Following Capacities Of Dg Sets :- 26 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 27 D. G . Set 100 Kva N 28 D.G . Set 125 Kva N 29 D. G . Set 160 / 200 / 250 Kva N 30 D. G . Set 320 Kva N 31 Supply Only Oil Filter Element With O Ring, Suitable For Following Capacities Of Dg Sets :- 32 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 33 D. G . Set 100 Kva N 34 D. G . Set 125 Kva N 35 D. G . Set 160 / 200 / 250 Kva N 36 D. G . Set 320 Kva N 37 Supply Only By Pass Filter Element With O Ring Suitable For Following Capacities Of Dg Sets :- 38 D. G . Set 100 Kva N 39 D. G . Set 125 Kva N 40 D. G . Set 160 / 200 / 250 Kva N 41 D. G . Set 320 Kva N 42 Supply Only Air Filter Element Suitable For Following Capacities Of Dg Sets :- 43 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 44 D. G . Set 100 Kva N 45 D. G . Set 125 Kva N 46 D. G . Set 160 / 200 / 250 Kva N 47 D. G . Set 320 Kva N 48 Supply Only Fan Belt Suitable For Following Capacities Of Dg Sets:- 49 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 50 D. G . Set 100 Kva N 51 D. G . Set 125 Kva N 52 D. G . Set 160 / 200 / 250 Kva N 53 D. G . Set 320 Kva N 54 Supply Only Belt For Battery Charging Alternator For Following Capacities Of Dg Sets :- 55 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 56 D. G . Set 100 Kva N 57 D. G . Set 125 Kva N 58 D. G . Set 160 / 200 / 250 Kva N 59 D. G . Set 320 Kva N 60 Supply Only Rubber Hose Pipe Set For Water Circuit Complete With Clamps, Suitable For Following Capacities Of Dg Sets :- 61 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 62 D. G . Set 100 Kva N 63 D. G . Set 125 Kva N 64 D. G . Set 160 / 200 / 250 Kva N 65 D. G . Set 320 Kva N 66 Supply And Fix In Repairs New Pvc Insulated Multisranded, Copper Conductor 70 Sqmm Of Multistranded 1.25 M Long Each Duly Fixed With Brass Clamps, Copper Lugs Suitable For Dg Sets Installed At Different Locations From Battery To Starter As Battery Leads. 67 Supply Only Engine Oil, Multi Grade 20W / 40 Complete All As Specified And As Directed. Nmake :- Indian Oil / Hindustan Petroleum / Castrol / Bpcl. 68 Supply And Fill Coolant In Radiator Complete All As Specified And As Directed 69 Supply And Applying Petroleum Jelly. ( 1 Kg Plastic Sealed Container. ) N 70 Supply And Fill In Batteries Distilled Water For Topping Up Complete All As Specified And As Directed. N 71 S & F In Repair Water Temperature Gauge Including Sensor And Cable Complete As Per Sample. Make : Pricol / Yenkey N 72 Supply & Fill Electrolyte Of Suitable Sp Gravity For Lead Acid Batteries In Sealed Container Complete All As Specified And As Directed. N 73 M & L Dismantling Of Radiator, Taking It To Work Shop For Overhauling & Cleaning Descaling With Acid Removal Of Leakage, Welding Brazing & Refixing It Duly Repaired Etc All As Directed By Engineer- In- Charge For The Following:- 74 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 75 D. G . Set 100 Kva N 76 D. G . Set 125 Kva N 77 D. G . Set 160 / 200 / 250 Kva N 78 D G Set 320 Kva 79 Calibration Of Fip And Injectors From The Authorised Dealer Including Petty Repairs To Make The Fip Functional For The Following Capacities Of Dg Sets Including Necessary Spares Required For Smooth Functioning Of Fip :- Note : A Certificate To The Effect That The Calibration And Repairs Has Been Carried Out By The Authorised Dealer Shall Be Submitted By The Contractor. 80 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 81 D. G . Set 100 Kva N 82 D. G . Set 125 Kva N 83 D. G . Set 160 / 200 / 250 Kva N 84 D. G . Set 320 Kva N 85 M&L For Repair / Overhauling Of Self Starter Incl. Replacement Of Carbon Brushes, Bearing, Bushes, Rewinding Of Armature And Field Etc. And Varnishing Complete All As Directed For The Following Capacity :- 86 24 Volts Make- Lucas Or As Per Generator N 87 12 Volts Make-Lucas Or As Per Generator N 88 M & L For Repairing Of Battery Charging Alternator Engine Mounted With Replacement Of Any Of The Unserviceable Part Such As Rectifier With Voltage Regulator, Diode Plate , Carbon Brushes For The Following Capacities And As Directed By Engineer-In- Charge :- 89 24 Volts Capacity N 90 12 Volts Capacity N 91 Supply & Fix In Repair Battery Charging Circuit Suitable For 12V, Dc In Existing Dg Set Panel Board Including Addition / Alteration In Wiring System Complete With Auto Transformer, Diodes, Filter Circuit, Condensers, Dc Ammeter, Dc Volt Meter With Selector Switches And Indicating Bulbs Etc Complete All As Specified And Directed By Engineer-In- Charge. 92 Supply And Fixing In Repair Battery Charging Circuit Suitable For 24V, Dc In Existing Dg Set Panel Board Including Addition Alteration In Wiring System Complete With Auto Transformer, Diodes, Filter Circuit, Condensers, Dc Ammeter, Dc Volt Meter With Selector Switches And Indicating Bulbs Etc Complete All As Specified And Directed By Engineer-In-Charge. 93 S & F In Repair Frequency Meter 96 X 96 Mm Flush / Square Pattern Complete All As Specified And As Directed 94 S & F In Repair Ammeter 0-200 / 5 Amps 96 X 96 Mm Square Flush Pattern With Selector Switch Complete All As Specified And As Directed 95 S & F In Repair Ammeter 0-100 / 5 Amps. 96 X96 Mm Square Flush Pattern With Selector Switch Complete All As Specified And As Directed 96 S & F In Repair Voltmeter 0-500 Volts. 96 X96 Mm Square Flush Pattern With Selector Switch Complete All As Specified And As Directed 97 S & F In Repair Indicator Lamps With Holder 15 Mm Screw Type Complete All As Specified And As Directed 98 S & F In Repair Ct Cast Resin Type Of Ratio 200 / 5 Amps, Of Suitable Va Burden, Make : Ae / L&T / Nutech / Amol N 99 S & F In Repair Ct Cast Resin Type Of Ratio 100 / 5 Amps, Of Suitable Va Burden, Make : Ae / L&T / Nutech / Amol N 100 S & F In Repair Power Contactor 415V, 50Hz, Ac Suitable For Following Dg Set Control Panel / Amf Panels For The Following Capacities And As Directed By Engineer-In-Charge. 101 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 102 D. G . Set 100 Kva N 103 D. G . Set 125 Kva N 104 D. G . Set 160 / 180 / 250 Kva N 105 D. G . Set 320 Kva N 106 S & F In Repair Time Delay Relay Suitable For 12.5 / 15 / 20 / 25 / 50 / 63 / 100 / 125 / 160 / 200 / 250 / 320 Kva Dg Set Complete All As Specified And As Directed 107 M&L For Tappet Setting Of Following Capacities Of Dg Sets Complete All As Specified And As Directed 108 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 109 D. G . Set 100 Kva N 110 D. G . Set 125 Kva N 111 D. G . Set 160 / 180 / 250 Kva N 112 D. G . Set 320 Kva N 113 Supply And Fix In Repair Automatic Voltage Regulator Up To 125 Kva Dg Set Complete As Per Existing Dg Sets All As Directed By Engineer-In-Charge. N 114 Supply And Fix In Repair Automatic Voltage Regulator Upto 320 Kva Dg Set Complete As Per Existing Dg Sets All As Directed By Engineer-In-Charge. N 115 Supply And Fix In Repair Fuel Steel Braided Pipe With Benjo Bolt And Washers Etc Complete Length Of 30 Cm Complete All As Specified And As Directed N 116 Supply And Fix In Repair Fuel Steel Braided Pipe With Benjo Bolt And Washers Etc Complete Length Of 45Cm Complete All As Specified And As Directed N 117 Supply And Fix In Repair Fuel Steel Braided Pipe With Benjo Bolt And Washers Etc Complete Length Of 60 Cm Complete All As Specified And As Directed N 118 Supply And Fix In Repair Control Wiring Of The Dg Set Upto 125 Kva Complete Incl Provision Of Additional Auto Cables Heavy Duty Suitable For Gen Set Application Complete All As Specified And As Directed N 119 Supply And Fix In Repair Control Wiring Of The Dg Set Above 125 Kva Up To 320 Kva Complete Incl Provision Of Additional Auto Cables Heavy Duty Suitable For Gen Set Application Complete All As Specified And As Directed N 120 Supply And Fix In Repair Pressure Guage 0 To 7 Kg / Sqcm Along With Sensor And Cable All As Directed By Engineer-In-Charge. N 121 Supply And Fix In Repair Water Temperature Guage Along With Sensor And Cable All As Directed By Engineer-In-Charge. 122 S&F In Repairs Ms Pipes 15Mm Dia Suitable For Diesel Incl Necessary Excavation Etc Complete All As Specified And As Directed N 123 Supply And Fix In Repair Lead Acid Battery 12 Volts 180 Ah With Initial Charging And Having Indicators To Know The Status Of Level Of Electrolyte Complete All As Specified And As Directed Nmake- Exide / Standard Furukawa / Amco / Amaron. N 124 Supply And Fix In Repair Lead Acid Battery 12 Volts 150 Ah With Initial Charging And Having Indicators To Know The Status Of Level Of Electrolyte Complete All As Specified And As Directed Nmake-Exide / Standard Furukawa / Amco / Amaron. N 125 M & L For Top Overhauling Only Of Dg Set Of Following Capacity Of Kirloskar / Cummins Or Any Make And Including Replacement Of Gaskets Etc Complete All As Specified And All Spare Parts Required To Complete The Work To The Satisfaction Of Engineer-In-Charge . 126 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 127 D. G . Set 100 Kva 128 D. G . Set 125 Kva 129 D. G . Set 160 / 200 / 250 / 320 Kva 130 Supply Only Oil Sump Packing Set Suitable For Following Dg Sets :- 131 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 132 D. G . Set 100 Kva N 133 D. G . Set 125 Kva N 134 D. G . Set 160 / 200 / 250 / 320 Kva N 135 Supply And Fix Solenoid Valve Suitable For Following Capacity Dg Sets For Smooth Functioning Of Dg Sets Complete To The Satisfaction Of Engineer-In-Charge :- 136 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 Kva N 137 100 / 125 Kva Dg Set 138 160 / 200 / 250 / 320 Kva Dg Sets 139 Supply And Fix Single Phase Preventer Suitable For Operation On 415 Volt 50 Hz Ac Supply ( Make- L&T / Minilec ) 140 Supply And Fix Microprocessor Based Multifunction Relay Suitable For Dg Stes Operation And Showing The Various Parameters Such As Volt, Ampere, Frequency, Rpm Etc Complete All As Specified And As Directed By Engineer-In-Charge 141 Supply And Fix In Repairs Fuse Base Suitable For Cylindrical / Din Fuse Link For Following Capacities And All As Directed By Engineer-In-Charge 142 160 Amps Capacity ( L&T Type Hb 160 Cat No. Sk90405 Or Same Type In Schneider / Siemens / C&S ) N 143 250 Amps Capacity ( L&T Type Hb 250 Cat No. Sk90406 Or Same Type In Schneider / Siemens / C&S ) N 144 Supply And Fix Din Type Hrc Fuse Link Type Hn Of Capacity 125 Amps N 145 Supply And Fix Din Type Hrc Fuse Link Type Hn Of Capacity 160 Amps N 146 Supply And Fix Din Type Hrc Fuse Link Type Hn Of Capacity 200 Amps N 147 Supply And Fix Din Type Hrc Fuse Link Type Hn Of Capacity 250 Amps N 148 Material & Labour For Earthing Complete Using Galvanised Iron Earth Plate Electrode Of Size 60Cm X 60Cm X 6Mm Thick Burried Directly In Ground Vertically At A Depth Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 M Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick And Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Galvanised Iron Strip Of Size 32X6 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Made Of Gi And Protected By Light Grade 40 Mm Dia Galvanised Iron Pipe And Gi Pipe Light Grade 20Mm Bore For Watering, Including Funnel, Wire Mesh, Ci Pit Cover And Pcc Chamber Pit With Pcc 1:2:4 Type B-2 ( Including Necessary Excavation And Earth Work Disposal Of Surplus Soil To A Distance Not Exceeding 50 M All As Specified And Shown On Electrical Plate No 3 Of Ssr Part-I 2009 And Testing On Completion All As Specified And Directed. 149 Supply And Fix Earth Continuity Conductor Fixed To Wall Or Burried In Ground Or Fixed To Pole Or Any Other Indicated Situation, Made Out Of Galvanised Iron Strip Of Size 32X6 Mm Complete 150 Preparation Of Old Painted Steel Surfaces Of The Dg Set Including Radiator, Fuel Tank Etc Of The Following Capacities Complete Degreasing And Spray Painting The Same With Two Coats Of Synthetic Enamel Paint Of Approved Shade Including Writing Sm / Mes Nos On Dg Set Complete All As Directed By Engr-In-Charge For Following :- 151 D. G . Set 12.5 / 15 / 20 / 25 / 50 / 63 / 100 Kva N 152 Dg Set 160 / 200 / 250 / 320 Kva Capacity 153 Supply And Replacement Of Fly Wheel Ring Of Cap 12.5 Kva To 63 Kva Dg Set Complete All As Specified And Directed. Make: Kirlosker / Cummins 154 Supply And Replacement Of Fly Wheel Ring Of Cap 100 Kva To 160 Kva Dg Set Complete All As Specified And Directed. Make: Kirlosker / Cummins 155 Supply And Replacement Of Fly Wheel Ring Of Cap 200 Kva To 320 Kva Dg Set Complete All As Specified And Directed. Make: Kirlosker / Cummins 156 M&L For Dismantling Of Complete Fuel Tank ( And Disconnect Fuel Pipe From Dg Sets ) For Cap 12.5 Kva To 63 Kva Dg Sets And Refixing Same After Proper Cleaning Of Fuel Tank And Replacement Of Fuel Pipe Of Existing Size And Two Coat Of Synthatic Enamel Paint By Spray Painting With Pcc Work And Welding Work Complete All As Specified And Directed By Engr In Charge. Note: Quoted Rates Are Included Opening Of Dg Set Canopy For Removing Of Fuel Tanks Which Are Provided Bottoms Base Plate Of Dg Sets. 157 M&L For Dismantling Of Complete Fuel Tank ( And Disconnect Fuel Pipe From Dg Sets ) For Cap 100 Kva To 160 Kva Dg Sets And Refixing Same After Proper Cleaning Of Fuel Tank And Replacement Of Fuel Pipe Of Existing Size And Two Coat Of Synthatic Enamel Paint By Spray Painting With Pcc Work And Welding Work Complete All As Specified And Directed By Engr In Charge. Note: Quoted Rates Are Included Opening Of Dg Set Canopy For Removing Of Fuel Tanks Which Are Provided Bottoms Base Plate Of Dg Sets. 158 M&L For Dismantling Of Complete Fuel Tank ( And Disconnect Fuel Pipe From Dg Sets ) For Cap 200 Kva To 320 Kva Dg Sets And Refixing Same After Proper Cleaning Of Fuel Tank And Replacement Of Fuel Pipe Of Existing Size And Two Coat Of Synthatic Enamel Paint By Spray Painting With Pcc Work And Welding Work Complete All As Specified And Directed By Engr In Charge. Note: Quoted Rates Are Included Opening Of Dg Set Canopy For Removing Of Fuel Tanks Which Are Provided Bottoms Base Plate Of Dg Sets. 159 M&L For Disconnecting & Opening Of Alternator And Removing Existing Stator, Rotor , Avr , Diode Etc From Dg Sets Of Cap 12.5 Kva To 25 Kva For Rewinding Of Stator, Rotar And Exciter Etc And Refixing Same , All As Directed By Engr - In Charge ( Note;- Rewinding Of Stator, Rotar And Exciter Will Be Measured And Paid Seperately 160 Rewinding Of Stater Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 12.5 Kva To 25 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 161 Rewinding Of Rotor Main Winding Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 12.5 Kva To 25 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 162 Rewinding Of Rotor Exciter Winding Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 12.5 Kva To 25 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 163 M&L For Disconnecting & Opening Of Alternator And Removing Existing Stator, Rotor , Avr , Diode Etc From Dg Sets Of Cap 50 To 62.5 Kva For Rewinding Of Stator, Rotar And Exciter Etc, And Refixing Same , All As Directed By Engr - In Charge Nnote:- Rewinding Of Stator, Rotar And Exciter Will Be Measured And Paid Seperately 164 Rewinding Of Stater Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 50 To 62.5 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 165 Rewinding Of Rotor Main Winding Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 50 To 62.5 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 166 Rewinding Of Rotor Exciter Winding Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 50 To 62.5 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 167 M&L For Disconnecting & Opening Of Alternator And Removing Existing Stator, Rotor , Avr , Diode Etc From Dg Sets Of Cap 100 To 125 Kva For Rewinding Of Stator, Rotar And Exciter Etc, And Refixing Same , All As Directed By Engr - In Charge Nnote:- Rewinding Of Stator, Rotar And Exciter Will Be Measured And Paid Seperately 168 Rewinding Of Stater Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 100 To 125 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 169 Rewinding Of Rotor Main Winding Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 100 To 125 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge 170 Rewinding Of Rotor Exciter Winding Complete Of Supper Enamelled Copper Wire As Per Existing Size For Dg Sets Of Cap 100 To 125 Kva For Making Complete Seviceable Of Alternator All As Directed By Engr - In Charge