| Name of Work: C/O Rajeev Gandhi Govt. Engineering College at Nagrota Bagwan Kangra (H.P.)(SH:- C/O Library and Computer Science Block Providing internal E.I ,Fire Alarm and Video Surveillance System therein.) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required..(Make:-Finolex,KEI,Anchor,L&T for wire )[Legrand (Myrius),L&T(Oris),Anchor(Roma plus) for accessories] | |||
| 2 | 1.01 | Group C. | 406 | P/Point | |
| 3 | 2 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required..(Make:-Finolex,KEI,Anchor,L&T for wire )[Legrand (Myrius),L&T(Oris),Anchor(Roma plus) for accessories] | |||
| 4 | 2.01 | Group C. | 8 | P/Point | |
| 5 | 3 | Wiring for light plug with 2x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.2.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 990 | P/metre | |
| 6 | 4 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 250 | P/metre | |
| 7 | 5 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 115 | P/metre | |
| 8 | 6 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | |||
| 9 | 6.01 | 2x2.5 Sq. mm. | 727 | P/mtr | |
| 10 | 6.02 | 2x6.0 Sq. mm. | 929 | P/mtr | |
| 11 | 6.03 | 2x10 Sq. mm. | 165 | P/mtr | |
| 12 | 6.04 | 2x16 Sq. mm. | 183 | P/mtr | |
| 13 | 7 | Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 101 | P/mtr | |
| 14 | 8 | Wiring for circuit / sub-main with 3x25+1x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (3x25+3x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-Finolex,KEI,Anchor,L&T ) | 50 | P/mtr | |
| 15 | 9 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.(Make:-Finolex,KEI, Anchor, L&T ) | |||
| 16 | 9.01 | 3x2.5 Sq. mm. | 805 | P/mtr | |
| 17 | 10 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required(Make:-BEC, AKG, Kalinga / Diplast ) | |||
| 18 | 10.01 | 25 mm dia | 120 | P/mtr | |
| 19 | 11 | Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:- | |||
| 20 | 11.01 | 2 modules (78mmx78mmx50mm)(Make:-Legrand,L&T,Schneider ) | 86 | Each | |
| 21 | 11.02 | 6 modules(205mmx78mmx50mm)(Make:-Legrand,L&T,Schneider ) | 1 | Each | |
| 22 | 12 | Supplying and fixing Electric Switch board having 3 No. of 5 amp switches and socket on suitable size of G.I Modular box of 205 mmx135 mm x60mm deep size with modular plate and cover in recess including providing and fixing 3 No 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.(Make:-Legrand,L&T,Schneider) | 152 | Each | |
| 23 | 13 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus) | 57 | Each | |
| 24 | 14 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as requiredMake:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus). | 26 | Each | |
| 25 | 15 | Supplying and fixing following rating Moduler switch /socket on the existing switch box / cover including connections etc. ,as required. | |||
| 26 | 15.01 | S.P. 25 Amps one way Modular switch. | 42 | Each | |
| 27 | 15.02 | 25 Amps Socket Modular . | 42 | Each | |
| 28 | 15.03 | Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus) | |||
| 29 | 16 | Supplying, Installation, Testing and Commissioning of Doubl;e Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 1 | P/Job | |
| 30 | 16.01 | MATERIAL: | |||
| 31 | 16.02 | MAIN INCOMER :-MCCB 630A, 4P 50 kA 1 Nos breaking capacity with adjustable thermal mangnetic release-1 Nos L&T Cat no CM94102OOT1OG/ABB/Schneider | |||
| 32 | 16.03 | OUTGOING : | |||
| 33 | 16.04 | MCCB 63 Amp ,3Pole 50 kA 1 Nos with thermal magnetic release L&T Cat NoDZ1T0063NXD1A-/ABB/Schneider,,MCCB 200 Amp,3Pole 50kA 1 Nos with TMR L&T Cat No-CM92006OOP1OG/ ABB/ Schneider,MCCB 100 Amp ,3Pole 50 kA 1 Nos with TMR L&T Cat No-CM92005OOL1OG/ ABB/ Schneider, MCCB 160 Amp ,3 Pole 50kA 2 Nos with TMR L&T Cat No-CM92006OON1OG/ ABB/ Schneider | |||
| 34 | 16.05 | Cable Alley on both sides Make:-L&T/Schneider/ABB ,Digital Meter module with ammeter,voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 35 | 17 | Supplying, Installation, Testing and Commissioning of Doubl;e Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 1 | P/Job | |
| 36 | 17.01 | MATERIAL: | |||
| 37 | 17.02 | MAIN INCOMER :-MCCB 200A, 4P 50 kA 1 Nos breaking capacity with adjustable thermal mangnetic release-1 Nos L&T Cat No-CM92106OOP1OG /ABB/Schneider | |||
| 38 | 17.03 | OUTGOING : | |||
| 39 | 17.04 | MCCB 100 Amp ,3Pole 36 kA 1 Nos with thermal magnetic release L&T Cat No-CM92008OOL1OG/ABB/Schneider,,MCCB 125 Amp,3Pole 36kA 1 Nos with thermal magnetic release L&T Cat No-CM92008OOM1OG/L&T/Schneider, | |||
| 40 | 17.05 | Cable Alley on both sides- Make:-L&T/Schneider/ABB,Digital Meter module with ammeter,voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 41 | 18 | Supplying, Installation, Testing and Commissioning of Double Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 1 | P/Job | |
| 42 | 18.01 | MATERIAL: | |||
| 43 | 18.02 | MAIN INCOMER :-MCCB 125 A, 4P 50 kA 1 Nos breaking capacity with adjustable thermal mangnetic release-1 Nos L&T Cat No-CM92105OOM1OG/ ABB/Schneider | |||
| 44 | 18.03 | OUTGOING : | |||
| 45 | 18.04 | MCCB 63 Amp ,3Pole 25 kA 2 Nos with thermal magnetic release L&T Cat No-DZ1TOO63DXD1A/ABB/Schneider, | |||
| 46 | 18.05 | Cable Alley on both sides Make:-L&T/Schneider/ABB ,Digital Meter module with ammeter, voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 47 | 19 | Supplying, Installation, Testing and Commissioning of Double Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 1 | P/Job | |
| 48 | 19.01 | MATERIAL: | |||
| 49 | 19.02 | MAIN INCOMER :-MCCB 160 A, 4P 50kA 1 Nos breaking capacity with adjustable thermal mangnetic release-1 Nos L&T Cat No-CM92106OON1OG /ABB/Schneider | |||
| 50 | 19.03 | OUTGOING : | |||
| 51 | 19.04 | MCCB 63 Amp ,3Pole 36 kA 1 Nos with thermal magnetic release L&T Cat No-DZ1TOO63DXD1A/ABB/Schneider,,MCCB 100Amp ,3Pole 25 kA 1 Nos with thermal magnetic release L&T Cat No-CM92008OOL1OG/ABB/Schneider, | |||
| 52 | 19.05 | Cable Alley on both sides Make:-L&T/ Schneider/ABB ,Digital Meter module with ammeter,voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 53 | 20 | Supplying, Installation, Testing and Commissioning of Double Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 1 | P/Job | |
| 54 | 20.01 | MATERIAL: | |||
| 55 | 20.02 | MAIN INCOMER :-MCCB 160 A, 4P 50 kA 1 Nos breaking capacity with adjustable thermal mangnetic release-1 Nos L&T Cat No-CM92106OON1OG /ABB/Schneider | |||
| 56 | 20.03 | OUTGOING : | |||
| 57 | 20.04 | MCCB 100Amp ,3Pole 25 kA 2 Nos with thermal magnetic releaseL&T Cat No-CM92008OOL1OG/ABB/Schneider, | |||
| 58 | 20.05 | Cable Alley on both sides Make:-L&T/Schneider/ABB,Digital Meter module with ammeter,voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 59 | 21 | Supplying, Installation, Testing and Commissioning of Double Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 5 | P/Job | |
| 60 | 21.01 | MATERIAL: | |||
| 61 | 21.02 | MAIN INCOMER :- MCCB 63A 4P 25 kA 1 Nos with thermal magnetic release L&T Cat No-DZ1FOO63NXD1A/ABB/Schneider, | |||
| 62 | 21.03 | Cable Alley on both sides Make:-L&T/Schneider/ABB ,Digital Meter module with ammeter,voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 63 | 22 | Supplying, Installation, Testing and Commissioning of Double Door type LT panel Board of suitable size,Dust and vermin prrof,fabricated out of 1.6 mm thick CRCA sheet steel,powder coated with 7 tank process,for better environment protection.MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB.The bus bar system should be duly type tested and NABL accredited LAB for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable aleeys on both sides for easy cable termination and should be complete with ammeter,voltmeter,selector switches,fuses, indicating lamps etc and copper Bus-Bar of rating equal or higher than the incomer MCCB current rating as per ISI Specifications and should be confirmed to IS:64139 and tested/checked from the CPRI Lab as per the drawing approved by the Engineer in charge | 3 | P/Job | |
| 64 | 22.01 | MATERIAL: | |||
| 65 | 22.02 | MAIN INCOMER :- MCCB 100A 4P 25 kA with thermal magnetic release L&T Cat No-DZ1F0100NXDIA/ L&T/Schneider | |||
| 66 | 22.03 | Cable Alley on both sides- Make:-L&T/Schneider/ABBDigital Meter module with ammeter,voltmeter,selector switches ,fuses ,indicating lamps etc Make:-L&T/Schneider/ABB | |||
| 67 | 23 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Make:-Hagger,Legrand,L&T ) | |||
| 68 | 23.01 | 6 amp Single pole. Cat-A. | 219 | Each | |
| 69 | 23.02 | 16 amp Single pole. Cat-A. | 26 | Each | |
| 70 | 23.03 | 25 amp Single pole. Cat-A. | 42 | Each | |
| 71 | 24 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:-Hagger,Legrand,L&T ) | |||
| 72 | 24.01 | 40 Amps. Cat-A. | 17 | Each | |
| 73 | 24.02 | 63 Amps. Cat-A. | 14 | Each | |
| 74 | 25 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:-Hagger,Legrand,L&T ) | |||
| 75 | 25.01 | 40 Amps. Cat-A. | 17 | Each | |
| 76 | 25.02 | 63 Amps. Cat-A. | 14 | Each | |
| 77 | 26 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(Make:-Hagger,Legrand,L&T ) | |||
| 78 | 26.01 | Double door-4 way | 6 | Each | |
| 79 | 26.02 | Double door-8 way | 1 | Each | |
| 80 | 26.03 | Double door-12 way | 11 | Each | |
| 81 | 26.04 | Double door-16 way | 19 | Each | |
| 82 | 27 | Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. | 4 | P/Set | |
| 83 | 28 | Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required. | 4 | P/Set | |
| 84 | 29 | Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required. | 40 | P/Mtr | |
| 85 | 30 | Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. | 2 | Each | |
| 86 | 31 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run) | 36 | P/Mtr | |
| 87 | 32 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run) | 50 | P/Mtr | |
| 88 | 33 | Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- | |||
| 89 | 33.01 | Armoured cable 400 sq. mm (3.5 core) | 60 | P/Mtr | |
| 90 | 33.02 | Make ;- Finolex,KEI,Havells | |||
| 91 | 34 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- | |||
| 92 | 34.01 | Armoured cable 35 sq. mm (3.5 core) | 33 | P/Mtr | |
| 93 | 34.02 | Armoured cable 50 sq. mm (3.5 core) | 62 | P/Mtr | |
| 94 | 34.03 | Armoured cable 70 sq. mm (3.5 core) | 20 | P/Mtr | |
| 95 | 34.04 | Armoured cable 400 sq. mm (3.5 core) | 30 | P/Mtr | |
| 96 | 34.05 | Make ;- Finolex,KEI,Havells | |||
| 97 | 35 | Providing and installation of Ceiling fan with step type fan regulator modular,air delivery 215m3/min power input 30watts speed 330 RPM includingf wiring the down rods of standard lenght(upto 30cm) with 16/0.20mm twin twisted felxible cotton braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and eartging required :- | |||
| 98 | 35.01 | Ceiling Fan 1200 mm sweep, Category-A | 93 | Each | |
| 99 | 35.02 | ( Usha-Technixplus BEE 3 Star rated model)makeUsha,Crompton,Anchor )(Minimum BEE 3 star rating) | |||
| 100 | 36 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- | |||
| 101 | 36.01 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep | 15 | Each | |
| 102 | 36.02 | Exhaust Fan, Heavy duty, 300 mm sweep | 3 | Each | |
| 103 | 36.03 | Makes:- Bajaj / Usha / Crompton | |||
| 104 | 37 | Providing and fixing following watt LED bulk head fitting die cast aluminium body with IP-65 protection of all sizes and shapes including making connections efficacy > 100 lumiens per watt,harmonics distortion < 10,CRI >80 ,Power factor > 0.95, testing and commissioning etc. as required complete in all respects. | |||
| 105 | 37.01 | 10 Watt LED bulk head. | 27 | Each | |
| 106 | 37.02 | Bulk head 10 Watt Panasonic ( Cat NO :- PBHMO1107),Phillips & Jaguar | |||
| 107 | 38 | Providing and fixing LED square, Surface mounted LED 10 watt downlight luminaire with die cast aluminium housing in white PC finish ,specially designed heat sink,anti glare diffuser and integrated energy efficient electronic driver. it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, complete with all accessories, connections, testing and commissioning etc. as required.. LED circular, Surface mounted LED 10 watt downlight luminaire) | |||
| 108 | 38.01 | LED surface mounted square LED downlight (10 watt) | 18 | Each | |
| 109 | 38.02 | (Make:-Tisva,Pansonic & Philips ) (At per Panasonic Cat No PDLM11104) | |||
| 110 | 39 | Providing and fixing surface mounted LED 4`x1` luminaire deep drawn CRCA aluminium housing with high power LED seamless front frame with flat white high transmission acrylic coverand it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 18 Watt complete with all accessories, connections, testing and commissioning etc. as required.LED 4`x1` luminaire panasonic ) | |||
| 111 | 39.01 | LED surface mounted LED 4`x1`, 36 watt | 10 | Each | |
| 112 | 39.02 | ((Make:-Tisva,Pansonic & Philips ) (At per Panasonic Cat No. PBLM15368) ) | |||
| 113 | 40 | Providing and fixing LED surface Tube fixture 30 watts LED batten anodized extruded aluminium housing high transmissibility diffuser and it should be compatible with specifications i.e.Power factor >0.9,Harmonic distortion <10% & efficiency >100 Lumen per watts,CRI >80 ,5700 K suitable for input voltage 220-240 Volts,50 HZ, Lenght 1175X30X36 mm.complete with connections and as per best satisfaction of Engineer-in-Charge complete as required. | |||
| 114 | 40.01 | LED Tube Fixture 30 Watt | 50 | Each | |
| 115 | 40.02 | Make:-Clair Code No.CLB30WF/Philips/Jaquar | |||
| 116 | 41 | Providing and fixing LED Base light, Recess mounted LED 36 watt with CRCA powered ,anti glair diffuser with seprate energy efficient electronic driver. it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 18 Watt complete with all accessories, connections, testing and commissioning etc. as required..LED Base light, Recess mounted LED 2`x2` luminaire 36 watt | |||
| 117 | 41.01 | LED 36 watts 2`x2` surface/recess | 134 | Each | |
| 118 | 41.02 | Make:- (Tisva,Pansonic & Philips )Panasonic ( Cat NO :- PBLMo1368) | |||
| 119 | 42 | Providing and fixing decorative and corrosion proof LED High way 2- 60 watt Built -in SPD,10 KV surge protection IP-68 LED Module,IP67 Driver/Connector efficiency upto 150 lm/w complete with all accessories, including connections, testing and commissioning etc. as required complete in all respects.POLAR PRIME HIGH WAY 2( Cat no :- 3188)(Make:-K-Lite/twinkle/Wipro) | 2 | Each | |
| 120 | 43 | Providing, Installation, testing and commissioning of wall mounted cabin fan 300mm complete with all accessories including making connections, testing etc. as required. Complete in all respect. | 23 | Each | |
| 121 | 43.01 | Maxx Air Dew Wall fan (300mm) Make:-Usha/cromptom/Bajaj | |||
| 122 | 44 | Providing and fixing aesthetically designed LED linear fixture suitable for suspended down type with houing made of high quality extruded aluminium alloy including die-cast alluminium end caps . it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz 6500K, complete with all accessories, connections, testing and commissioning etc. as required. | |||
| 123 | 44.01 | Suspended linear Profile light Make :- Tiswa cat No PL366304 | 111 | Each | |
| 124 | 44.02 | Fire Alarm and P.A. System as per detail -II | |||
| 125 | 45 | Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with X Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8\" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . The panel shall be UL/EN/VDS Certified. Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 1 | Each | |
| 126 | 46 | Supply, Installation, Testing and Commissioning of Active and networkable repeater panel with 4x20 character LCD display complete system function keys for programming and control like system reset, alarm acknowledgement, alarm silence, trouble acknowledgement etc. Shall be UL/EN/VDS Listed Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 1 | Each | |
| 127 | 47 | Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector)Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 168 | Each | |
| 128 | 48 | Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 4 | Each | |
| 129 | 49 | Supply, Installation, Testing and Commissioning of addessable DUAL ACTION manual pull station & necessary fixing arrangements with key complete as required. Shall be UL/EN/VDS Certified. Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 8 | Each | |
| 130 | 50 | Supply, Installation, Testing and Commissioning of Sounder cum strobes with 3 different tone variants selection options & adjustable sound pressure by 3 levels, the sound pressure 92 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity 15cd-185cd. Shall be UL/EN/VDS Certified.Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 8 | Each | |
| 131 | 51 | Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL/EN/VDS Certified. Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 4 | Each | |
| 132 | 52 | Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doorsetc.. Shall be EN54/ Vds Certification/UL Make Bosch/ Siemens Fire Finder / Honeywell Notifier / Edwards | 5 | Each | |
| 133 | 53 | Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX | 12 | Each | |
| 134 | 54 | Supply, Installation, Testing and Commissioning of Voice Alarm Controller Compliant with standards for emergency sound systems (IEC60849) 6-zone system controller Built-in 240 W booster amplifier 12 Business and emergency control inputs and outputs. Frequency response - 60 Hz – 18 kHz (+1/-3 dB, @ -10 dB ref. rated output),Distortion,- < 1% @ rated output, 1 kHz,Bass control -8/+8 dB @ 100 Hz,Treble control -8 /+8 dB @ 10 kHz, Voice Alarm Call station with 6 zone selection.Nominal sensitivity 85 dB SPL (gain preset 0dB), Nominal output level -700 mV Maximum input sound level 110 dB SPL, Limiter threshold 2 V,Compression ratio limiter 20:1,Distortion < 0.6% (maximum input),Equivalent input noise level -25 BSPLA,Frequency response -100Hz – 16kHz,Speech filter( -3 dB @ 315 Hz, high-pass), 6 dB/oct,Output impedance - 200 Ohms. Make BOSCH/Honeywell/Panasonic | 1 | Each | |
| 135 | 55 | Supply, installation, testing & commissioning of wall mounted cabinet speaker of 6W RMS power with multi taps 3''of 6W/3W/1.5 W, handling capacity, inbuilt 100 volt line matching transformer, wide opening angle, optimized for music and speech application complete with mounting clamps.Make BOSCH/Honeywell/Panasonic | 16 | Each | |
| 136 | 56 | Supply, Installation, Testing and comissioning of 2 core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Make KEI,Finolex,Havells | 1200 | Mtr | |
| 137 | 57 | Supply, installation, testing & commissioning of PVC Conduit Pipe, 25mm medium, ISI Mark with complete accessories. Make: Diplast/Polyplast | 800 | Each | |
| 138 | 58 | Supply, installation, testing & commissioning of battery backup for controllers ( 2 KVA UPS CUM Invorter with 1 hours backup ) Make APC/ LIEBERT EMERSON/luminous | 1 | Each | |
| 139 | 58.01 | Video Surveillance system as per detail-III | |||
| 140 | 59 | Supply Installation testing and Comissioning of 2 MP Dome Camera lmage device Resolution - 2 Megapixel (1920 x 1080) ,Frame rate Up to 30 fps ,Lens Type - 3.5 to 9 mm auto varifocal lens Motorized,IR Light & Distance - Ir Range upto 30 mtrs,Signal to Noise Raio - >50db ,Minimum lllumination - 0.3Lx Color; lR LED ON 0 .0 Lux ,Day Night - Auto Day/Night with switchable IR cut filter,Video Compression - H.265,H.264,M-JPEG ,Camera should have Multiple Streaming- Min. Triple,Edge Based Analytics Tracking, line crossing detection ,Enter/leave Field, stationary / moved object ,Loitering, crowd density,follow route(All Analytics to be already included in cost),Storage - SD Card slot should be expandable up to 128 GB,System Compatibitity - ONVlF Profite S&G,Privacy Masking - Minimum 4 Privacy zones,Protocols - lPv4/lPv6, HTTP, HTTPS, TCP/lP, UDP, UPnP, ICMP, RTSP,RTP, SMTP, NTP, DHCP, DNS, DDNS,Additional Features,Noise Reduction - Digitat Noise Reduction on/off.,WDR -120dB WDR,Atarm Input/Output - 1 Alarm Input, 1 ALarm OutPut,Audio Input/Output - 1 audio input/1 audio outPut,Environment,Operating Environment – lndoor/ Outdoor,Operating Temperature -0C to 50 c,Intelligent Defog automatically adjusts parameters for best picture in foggy or misty scenes,lngress protection & vandaI resident standards - lP66 or better and IK10,Certificates: UL, FCC, EN ( Make :-Axis / Bosch /Sony ) | 16 | Each | |
| 141 | 60 | Supply Installation testing and Comissioning of 2 MP Bullet Camera Resolution - 2 Megapixel (1920 x 1080),Frame rate Up to 30 fps,Lens Type - 3.5 to 9 mm auto varifocal lens Motorized,IR Light & Distance - Ir Range upto 30 mtrs ,Signal to Noise Raio - >50db ,Minimum lllumination - 0.3Lx Color; lR LED ON 0 .0 Lux ,Day Night - Auto Day/Night with switchable IR cut filter,Video Compression - H.265,H.264,M-JPEG ,Camera should have Multiple Streaming- Min. Triple,Edge Based Analytics Tracking, line crossing detection ,Enter/leave Field, stationary / moved object ,Loitering, crowd density,follow route(All Analytics to be already included in cost),Storage - SD Card slot should be expandable up to 128 GB,System Compatibitity - ONVlF Profite S&G,Privacy Masking - Minimum 4 Privacy zones,Protocols - lPv4/lPv6, HTTP, HTTPS, TCP/lP, UDP, UPnP, ICMP, RTSP,RTP, SMTP, NTP, DHCP, DNS, DDNS,Additional Features :-Noise Reduction - Digitat Noise Reduction on/off,WDR -120dB WDR,Alarm Input/Output - 1 Alarm Input, 1 ALarm OutPut,Audio Input/Output - 1 audio input/1 audio outPut,Environment:-Operating Environment – lndoor/ Outdoor,Operating Temperature -0C to 50 c,Intelligent Defog automatically adjusts parameters for best picture in foggy or misty scenes,lngress protection & vandaI resident standards - lP66 or better and IK10,Certificates: UL, FCC, EN( Make :-Axis / Bosch /Sony ). | 5 | Each | |
| 142 | 61 | Supply installation Testing and Commissining of IP IR PTZ Dome Camera PoE Enabled (High Definition),lmage device/Sensor - 1/3\" Progressive Scan CCD/ Progressive scan CMOS ,Resotution - 2 Megapixel, 1080p (1920x1080) ,Optical Zoom 30X & Digital Zoom: 12X,lR Light & Distance - lR range up to 180 Mtrs. Or above,Signal to Noise Ratio - >_50 dB (AGC OFF ),PAN & Tilt travel - Pan 360 endless Tilt 0 to -90 (Auto Flip),Minimum lIIumination - 0.3Lx Color and B/W 0.01Lx,Day Night - Auto Day/Night with Auto lR-CUT fitter with auto switch,Encoding Video Compression - H.265 MJPEG Triple Stream encoding,Frame Rate - Main Frame 30 FPS in all resolution or better,Audio Compression - G.711/G.726,Edge Based Analytics Tracking, line crossing detection ,Enter/leave Field, stationary / moved object ,Loitering, crowd density,follow route,Storage - SD Card shoutd be expandabte up to 128 GB,Protocols - lPv4/lPv6, TCP/lP, UDP, RTP,RTSP, HTTP, HTTPS, ICMP,SMTP, NTP, DHCP, UPnP, IGMP,SNMP,IEEE 802.1 X,System Compatibitity - ONVlF Profite S & G,Privacy Zone - Minimum 4 Privacy zones or higher,Additional Features:-Noise Reduction-Digitat Noise Reduction on/off .,WDR -90dB True WDR or better,Alarm Input,/ Alarm Output-1 Alarm Input, 1 Alarm Output,Audio Input,/ Audio Output-1 Audio Input, 1 Audio Output,Environment-Operating Environment-Outdoor,Operating Temoerature- 0'C to 50'C,lngress protection lP66 or better,Certificates: UL, FCC, EN( Make :-Axis / Bosch /Sony ) | 1 | Each | |
| 143 | 62 | Supply, Installation, Testing and comissioning of Network video recorder With 24 TB HD to a maximum of 32 IP cameras,The recorders can be installed with a maximum of 4 internal HDDs for video storage. Option of a 2 HDDs for storage, plus a DVD burner for video export. Max. capacity per HDD: 6 TB. 1 no. E-SATA supported. The recorders comes with a built-in PoE+ switch as an option. 16 alarm i/p & 6 relay o/p.Simultaneous 1/4/9/16 channels playback. H.265/H.264/MJPEG supported. iPhone/Android support. Maximum incoming bandwidth of 320 Mbps. Maximum recording bandwidth of 320 Mbps. 1 I/O for audio. 1 VGA & 2 HDMI outputs. CE, UL & FCC certified Make Axis / Bosch / Avigilion /Sony | 1 | Each | |
| 144 | 63 | SITC of Layer-2 POE plus Gigabit Ethernet 1RU chassis with 24 PoE 10/100/1000 BaseT ports and 4 Gigabit SFP ports. Includes an internal AC power supply 370W atleast or higher power budget) with a power cord, manuals access card, and RJ-45 to DB-9 adaptor.The Access Switch should have 4 ports of 1 G SFP.The Access Switch should provide Non-Blocking switch fabric capacity of 56 Gbps or more. L-2 switch should provide wire-speed packet forwarding of 41 Mpps or more. L-2 Switch should support min 16K MAC addresses and min 4000 active VLANs. Make:Cisco/Alcatel/Zyxel/Juniper | 3 | Each | |
| 145 | 64 | SITC of the Switch configured to provide Wire-Speed Non-Blocking Switching and Routingshould be Performance at Layer 2 and basic Layer 3 on all ports. switch has Gigabit Ethernet 1RU chassis. 24 100/1000 ports, 2 SFP/RJ45 combo, 2 SFP+ 1G/10G ports, one expansion slot. 1588v2 support. Includes an internal AC power supply Switch Should Support IPV4 and IPV6 from day one.The Switch should support full Layer 2 features like STP, RSTP, MSTP, QoS and Make:Cisco/Alcatel/Zyxel/Juniper | 1 | Each | |
| 146 | 65 | SITC of 6U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit Make: Netrack/Comrack/Valrack. | 3 | Each | |
| 147 | 66 | SITC of 22U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack | 1 | Each | |
| 148 | 67 | SITC of 2 KVA UPS Overvoltage cut-off device (OVCD),Support for up to 42 AH external batterys cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for IndianEnvironmental Condition andfor Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup MAKE APC/ LIBERT EINOVA/Emerson | 1 | Each | |
| 149 | 68 | SITC of CAT6 UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m onforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 Make R&M/Siemon/Systimax | 21 | Each | |
| 150 | 69 | SITC of 24-port 19\" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19\" 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated Make (R&M/Systimax/Seimon) | 3 | Per Mtr | |
| 151 | 70 | SITC of CAT 6 UTP Cable.Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report. Make: Panduit/R&M/ Systimax) | 2250 | Per Mtr | |
| 152 | 71 | SITC of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: BEC, AKG, Kalinga / Diplast | 800 | Each | |
| 153 | 72 | SITC of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/KEI | 200 | Per Mtr | |
| 154 | 73 | SITC of UTP Field Termination Connector IP20 Connection type Toolless Insulation Displacement Connection Category Cat 6 UTP, IP Class IP 20 rated, Certification UL Listed. Make:(R&M/ Systimax/Seimon) | 22 | Per Mtr |