Provision Of Runway Controller Hut With Toilet And Provision Of Runway Controller Hut With Toilet And Covered Parking Shed For Cpt Vehicle At Af Station Jamnagar .

Tender Notice

25837105
Corrigendum : Provision Of Runway Controller Hut With Toilet And Provision Of Runway Controller Hut With Toilet And Covered Parking Shed For Cpt Vehicle At Af Station Jamnagar .
Indian
Gujarat
25-11-2020
10-12-2020
11-12-2020

Tender Details

Provision Of Runway Controller Hut With Toilet And Provision Of Runway Controller Hut With Toilet And Covered Parking Shed For Cpt Vehicle At Af Station Jamnagar .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Nov-202 Amendment2 BOQ 10-12-2020

Key Value

Document Fees
INR 1000 /-
EMD
INR 123775.00 /-
Tender Value
INR 65.85 Lakhs /-

Attachment

FileName File Description File Size
54BF1336-B93D-43D8-B6FE-1FEE16F6DF83.html Tender Notice-Tender Notice 0
tende.rar Tender Document-tender 2106.09
BOQ_434925.xls Tender Document-BOQ 315.00
Drg.pdf Tender Document-Drg 15288.62
Tendernotice_1.pdf Tender Document-PROVISION OF RUNWAY CONTROLLER HUT WITH TOILET AND COVERED PARKING SHED FOR CPT VEHICLE AT AF STATION JAMNAGAR. 266.48

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

NAME OF WORK: PROVISION OF RUNWAY CONTROLLER HUT WITH TOILET AND COVERED PARKING SHED FOR CPT VEHICLE AT AF STATION JAMNAGAR
Sl. No. Item Description Item Code / Make Quantity Units
1 0.01 NOTE: Schedule ‘A’ Part I to X are under Ser No. 1.00 to 10.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the blue coloured field under Col-6 only.\n
2 1 Lump sum price worked out for BUILDING/ STRUCTURE as listed in Sch `A’ Part I.\n 1 Lumpsum
3 2 Lump sum price worked out for SITE CLEARANCE, EXCAVATION AND EARTHWORK as listed in Sch `A’ Part II\n 1 Lumpsum
4 3 Lump sum price worked out for INTERNAL WATER SUPPLY as listed inSch `A’ Part III.\n 1 Lumpsum
5 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch `A’ Part IV.\n 1 Lumpsum
6 5 Lump sum price worked out for ROAD / PATH / HARDSTANDING as listed in Sch `A’ Part V.\n 1 Lumpsum
7 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch `A’ Part VI.\n 1 Lumpsum
8 7 Lump sum price worked out for EXTERNAL ELECTRIC SUPPLY as listed in Sch `A’ Part VII.\n 1 Lumpsum
9 8 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch `A’ Part VIII.\n 1 Lumpsum
10 9 Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch `A’ Part IX.\n 1 Lumpsum
11 10 Lump sum price worked out for DEMOLITION / DISMANTLING as listed in Sch `A’ Part X.\n 1 Lumpsum
12 10.01 SCHEDULE `A' PART - XI (MISC ITEMS)
13 11 M&L for moorum filling in floors or paving laid in layers n.exc 15 cm thick, spread, leveled and rammed including watering & well ramming complete all all as directed \n\n 108 Cum
14 12 M&L for 150 mm thick (compacted thickness ) wet mix macadam (WMM) in two layers of 75 mm each, with crushed stone aggregate of grading as specified in Particular Specifications, spread, rolled and consolidated to required gradient and camber and shape all as specified and as directed by Engineer-in-charge. 54 Cum
15 13 M&L for PCC 1:2:4, type B2 (using 40 mm graded stone agg) as in dry lean concrete (DLC) with 7 days compressive strength as 10 Kg / Sqcm, including necessary steel form work all as specified and directed 54 Cum
16 14 M&L for polythene film black 150 micron confirming to IS - 2508 laid in over sand cushioning complete all as specified and as directed by Engr-in-Charge. 360 Sqm
17 15 M&L for Boring under roads / pavement / hardstanding without disturbing the top surface by trench less technology using necessary machine including supplu & inserting HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. \n\nNote : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost. 30 RM
18 16 Cutting of existing DI pipe in position of size 150 mm dia, supply & inserting new DI tee of size 150 mm x 150 mm x 50 mm heaving 150 mm socket at two ends and flange at 80 mm side, including run lead joint with all necessary fittings & fixture complete all as specified and directed by Engineer-in-Charge. 1 Each Job
19 17 Cutting of existing DI pipe in position of size 200 mm dia, supply & inserting new DI tee of size 200 mm x 200 mm x 80 mm heaving 200 mm socket at two ends and flange at 80 mm side, including run lead joint with all necessary fittings & fixture complete all as specified and directed by Engineer-in-Charge. 1 Each Job
20 18 Supply & fix in repair 50 mm size sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete.\n 1 Each
21 19 Supply & fix in repair 80 mm size sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete.\n 1 Each
22 20 Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.\n 4 Each
23 20.01 Note:-\nQuoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
24 21 Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 mm x6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.\n\n 20 Each Job
25 21.01 Note:-\nQuoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
26 22 Material and labour for earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to Copper strip of size 20 mm x 3 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 25 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.\n 4 Each Job
27 22.01 Note:-\nQuoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
28 23 Material and labour for construction of valve chamber of size 900 x 900 x 900 mm deep (Over all internal dimension) for sluice valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:-\n\n\n \n\n\n\n 2 Each Job
29 23.01 (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry.
30 23.02 (ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete.
31 23.03 (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth.
32 23.04 (iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall.
33 23.05 Item No 23 contd…….\n\n(v) Entire plastered surfaces shall be treated with 3 coat of white wash.
34 23.06 (vi) Chamber cover shall be of 3 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer.
35 24 Supplying & laying factory made unreinforced precast cable cover LV type 1, flat of size 250 x 150 x 40 mm all as directed by Engr-in-Charge. 5250 Each
36 25 Supply, installation, commissioning and testing of LT Feeder pillar factory made (CPRI approved), outdoor cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x 50 x 6 mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground but PCC foundation (1:2:4) type Bl, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, suitable for 3 phase 4 wire system 500 volts grade with necessary wiring with PVC sheathed stranded copper conductor of appropriate length size with and including fixing lugs, bolts, screws etc complete and comprising of the following accessories:- 2 Each Job
37 25.01 (a) Aluminium bus bar of rated capacity 100 Amps covered with PVC insulated sleeves, including insulator, nuts, bolts etc incl connection complete. = 01 set
38 25.02 Item No 25 Contd …..\n\nINCOMING
39 25.03 (b) MCCB 63 Amps, 415V, 4 pole, 50Hz, breaking capacity 25 KA with fixed thermal and magnetic setting - 01 Nos.
40 25.04 OUTGOING
41 25.05 (c) MCB TPN 32 Amps, 415V , 02 Nos
42 25.06 (d) Voltmeter digital type -01 No
43 25.07 (e) Ammeter digital type with CT`s - 01 No
44 26 Supply and fix MCB’s Tripple pole & neutral, 40 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. 2 Each
45 27 S&F MCCB 63 Amps, 415V, 4 pole, 50Hz, breaking capacity 25 KA with fixed thermal and magnetic setting complete. 2 Each
46 28 Supply & installation of 2.0 ton capacity Air cooled inverter based cassette type split AC unit with cooling functions and suitable at ambient for outdoor unit 15 to 46 Deg C in cooling mode .\n 2 Each
47 28.01 Item No 28 Contd …..\nCassette type Air Conditioner will have following conditions :- \n(i) Refrigerant - R410 A (non CFC)\n(ii) EER - min 3.5 w/w ( 5 star )\n(iii) Tonnage - Not less than 2.0 TR \n(iv) Indoor Noise Level - Not more than 40 Db \n(v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter .\n(vi) Function of Remote- (a) air directional control (b) Auto timer (c) Economic sleep mode (d)Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode . \nAll specification will be as per IS -1391 (part 2) 1992 Room Air Conditioner . \n\nMake :- Carrier / Hitachi / Daikin / Mitshubishi \n\n
48 28.02 Note :- \n(i) piping length up to 8 mtr will be inclusive in item and above 8 mtr it will be measured and paid seperately.
49 28.03 (ii) Installation will include fixing the outdoor unit on the platform / wall as per direction of Engineer -in-charge.
50 28.04 (iii) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe.
51 28.05 Item No 28 Contd …..\n(iv) Testing and Commissioning of the Air conditioner to the entire satisfaction of Engineer -in-Charge. \n
52 28.06 (v) Contractor will provide warranty of 5 year for compressor from the date of completion.
53 28.07 (vi) After installation, service of Air Conditioner company shall be included upto one (01) year without any cost . \n
54 29 S&F Voltage stabilizer of automatic operation single phase naturally air cooled indoor type and designed for following feature:- \n(a) Capacity :-5 KVA \n(b) working voltage range - 130V -280 AC \n(c ) Silent feature - (i) compatible with regular and inverter AC (iii) Wall mounting cabinet design (iv) Low and High voltage cut off (v) Digital display . \nMake :- V Gaurd / Daikin / Blue star 4 Each
55 30 S&F LED type Aviation obstruction light yellow painted die cast aluminium alloy housing, heat resistant, clear thick red glass and accessories with LED lamp \n\nMake:- Phillips - Cat No: XGP 400 1 x LED-K2 / RD 240 V or equivalent make mention Appx B 6 Each
56 31 Supply and fix LED tube light fitting with fixture of 09 watt, surface / wall mounted LED batten , extruded aluminium housing provided for efficient heat dissipation, polycarbonate diffuser, integrated electronic driver with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge. \n\nMake Havell's cat part No LHEXBQP5IN1W009 or equivalent of make mention in Appx 'B'. 16 Each
57 32 Supply and fix LED tube light fitting with fixture of 18 watt, surface / wall mounted LED batten , extruded aluminium housing provided for efficient heat dissipation, polycarbonate diffuser, integrated electronic driver with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge. \n\nMake Havell's cat part No LHEXBQP5IN1W018 or equivalent of make mention in Appx 'B'. 18 Each
58 33 Supply and fix exhaust fan 300 mm sweep AC, 240 volts, metal body, fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete. \n\nMake Havells cat No. Ventil Air - DSP or equvellent of Make mention in Appx B\n\n 2 Each
59 34 Supply and fix MCB’s single pole, 6-32 Amps, 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.\n\n 16 Each
60 35 Supply and fix MCB’s single pole & neutral, 6-32 Amps, 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.\n\n 4 Each
61 36 Supply and fix MCB’s tripple pole & neutral, 40 Amps, 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.\n\n 2 Each
62 37 S&F LED Building security light fitting 15 watt, lumen efficiency not less tahn 100 lumen / watt, IP 65 protection, consisting of Electronic driver circuits, high quality Transmittance lens, powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on wall with and including 1200 mm long 25 mm dia light grade GI pipe bracket, MS flat iron clamp & nut / bolt etc & connecting complete.\n 6 Each
63 38 Supply & fix Anaerobic Package Type modular Septic tank of capacity 1800 litre (25 Users), maintenance free, placed over 150 mm thick PCC base of Mix 1:3:6 type C2 (using 40mm graded stone aggregate), connecting with inlet & outlet pipe including Excavation & earthwork, in any type of soil, backfilling with sand complete, all as per manufacture instruction. \n\nMake:- Sintex Model No PWTS-AM 180-01 or equivalent make as approved by the GE.\n 2 Each
Disclaimer :