Manning & Operation Of Ac Plants, Dg Set, Pump Sets, Swimming Pool, Maintenance Of Ac Plants & Cooling Appliance And Repair/ Replacement Of Fire Fighting & Fire Alarm System At Mo (Mb) Ghatkopar And Nchc Powai Under Ge (Nw) Bhandup, GHATKOPAR AND POWAI-Maharashtra

Military Engineer Services-MES has published Manning & Operation Of Ac Plants, Dg Set, Pump Sets, Swimming Pool, Maintenance Of Ac Plants & Cooling Appliance And Repair/ Replacement Of Fire Fighting & Fire Alarm System At Mo (Mb) Ghatkopar And Nchc Powai Under Ge (Nw) Bhandup. Submission Date for this Tender is 26-11-2020. Fire Alarm Systems Tenders in GHATKOPAR AND POWAI Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

25819030
Corrigendum : Manning & Operation Of Ac Plants, Dg Set, Pump Sets, Swimming Pool, Maintenance Of Ac Plants & Cooling Appliance And Repair/ Replacement Of Fire Fighting & Fire Alarm System At Mo (Mb) Ghatkopar And Nchc Powai Under Ge (Nw) Bhandup
Open Tender
Indian
Maharashtra
GHATKOPAR AND POWAI
26-11-2020

Tender Details

Manning & Operation Of Ac Plants, Dg Set, Pump Sets, Swimming Pool, Maintenance Of Ac Plants & Cooling Appliance And Repair / Replacement Of Fire Fighting & Fire Alarm System At Mo ( Mb ) Ghatkopar And Nchc Powai Under Ge ( Nw ) Bhandup

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Nov-2020 DATE CORRIGENDUM 2 Date 26-11-2020
2 26-Nov-2020 OTHER AMDT Other 26-11-2020

Key Value

Document Fees
INR 1000 /-
EMD
INR 201000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: MANNING & OPERATION OF AC PLANTS, DG SET, PUMP SETS, SWIMMING POOL, MAINTENANCE OF AC PLANTS & COOLING APPLIANCE AND REPAIR/ REPLACEMENT OF FIRE FIGHTING & FIRE ALARM SYSTEM AT MO (MB) GHATKOPAR AND NCHC POWAI UNDER GE (NW) BHANDUP
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SECTION-I MAINTENANCE AND OPERATION OF E/M INSTALLATIONS
2 2 Manning and Operation of the following items in three shifts per day (each shift 08 hrs continuous duration) operated by one operator in each shift including periodical maintenance/repairs (daily check and cleaning, monthly, quarterly, half yearly maintenance) with all consumables parts (except for major assembly/items/jobs as mentioned) of Central AC plant\n (a) Central AC plant of capacity 3 x 40 ton (DX system) comprising of compressors, motor, condensers, Chillers, AHU, refrigerant, piping, controls, pumps, water supply pipes and controls cooling towers, eletrical panels, instruments starters, strip heaters and repairs/replacement of control cabling/wiring including for the smooth and effiecient of AC plant to achieve desired inside conditions through out the given period. (Location SSK 47 MO MB Ghatkopar)\n (i) First Shift - 0600 hrs to 1400hrs\n (ii) Second Shift - 1400 hrs to 2200 hrs\n (iii) Third Shift - 2200 hrs to 0600 hrs
3 2.01 Basic Rate (Wage) payable to the operators 1005 Per Shift
4 2.02 Contribution towards EPF 1005 Per Shift
5 2.03 Contribution towards ESIC 1005 Per Shift
6 2.04 Contribution towards Bonus 1005 Per Shift
7 2.05 Over Head and Profit on Srl item No. 2.01 to 2.04 1005 Per Shift
8 2.06 Labour Welfare Cess payable on Srl item No 2.01 to 2.05 1005 Per Shift
9 3 Notes for Srl No. 2.01 to 2.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 2.01, 2.02, 2.03, 2.04, 2.05 and 2.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
10 4 Manning and operating of central AC plant of capacity 3 x 50 ton (2 x 50 TR in running and 1 x 50 TR in standby) in three shifts/day (including Sundays and holidays) per day each shift of 8 hrs operated by one operator in each shift of central AC plant comprising of compressors, motors, condensors, chillers, AHU, refrigerant, piping, controls, pumps, water supply pipes and controls cooling towers, eletrical panels, instruments starters, strip heaters complete all as specified and directed. Make: Voltas, Location Heavy Lift Shed (Vikramaditya) at MO (MB) Ghatkopar)\n(i) First Shift - 0600 hrs to 1400hrs\n(ii) Second Shift - 1400 hrs to 2200 hrs\n(iii) Third Shift - 2200 hrs to 0600 hrs
11 4.01 Basic Rate (Wage) payable to the operators 1005 Per Shift
12 4.02 Contribution towards EPF 1005 Per Shift
13 4.03 Contribution towards ESIC 1005 Per Shift
14 4.04 Contribution towards Bonus 1005 Per Shift
15 4.05 Over Head and Profit on Srl item No. 4.01 to 4.04 1005 Per Shift
16 4.06 Labour Welfare Cess payable on Srl item No 4.01 to 4.05 1005 Per Shift
17 5 Notes for Srl No. 4.01 to 4.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 4.01, 4.02, 4.03, 4.04, 4.05 and 4.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
18 6 Manning and operating of central type water cooled chiller type/DX AC plant of capacity 3 x 26 ton (2 x 26 TR in running and 1 x 26 TR in standby) in One shifts/day (including sundays/Holidays) each shift of 8 hrs operated by one operator from 0900 hrs to 0500 hrs each shift of central AC plant comprising of compressors, motors, condensors, chillers, AHU, refrigerant, piping, controls, pumps, water supply pipes and controls cooling towers, eletrical panels, instruments starters, strip heaters complete all as specified and directed. Make: Blue star, NS-26 at MO (MB) Ghatkopar)\n(i) Shift - 0900 hrs to 1700hrs\n
19 6.01 Basic Rate (Wage) payable to the operators 335 Per Shift
20 6.02 Contribution towards EPF 335 Per Shift
21 6.03 Contribution towards ESIC 335 Per Shift
22 6.04 Contribution towards Bonus 335 Per Shift
23 6.05 Over Head and Profit on Srl item No. 6.01 to 6.04 335 Per Shift
24 6.06 Labour Welfare Cess payable on Srl item No 6.01 to 6.05 335 Per Shift
25 7 Notes for Srl No. 6.01 to 6.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 6.01, 6.02, 6.03, 6.04, 6.05 and 6.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
26 8 Manning and operating of package type AC plant of capacity 3 x 11 ton (2 x 11TR in running and 1 x 11 TR in standby) in One shifts/day (including sundays/Holidays) each shift of 8 hrs operated by one operator from 0900 hrs to 0500 hrs each shift of central AC plant comprising of compressors, motors, condensors, chillers, AHU, refrigerant, piping, controls, pumps, water supply pipes and controls cooling towers, eletrical panels, instruments starters, strip heaters complete all as specified and directed. Make: Voltas, Location :SPDC-08\n(i) Shift - 0900 hrs to 1700hrs\n
27 8.01 Basic Rate (Wage) payable to the operators 335 Per Shift
28 8.02 Contribution towards EPF 335 Per Shift
29 8.03 Contribution towards ESIC 335 Per Shift
30 8.04 Contribution towards Bonus 335 Per Shift
31 8.05 Over Head and Profit on Srl item No. 8.01 to 8.04 335 Per Shift
32 8.06 Labour Welfare Cess payable on Srl item No 8.01 to 8.05 335 Per Shift
33 9 Notes for Srl No. 8.01 to 8.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 8.01, 8.02, 8.03, 8.04, 8.05 and 8.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
34 10 Manning, operation and routine maintenance of swimming pool and its pump sets alongwith electrical panel board and chloronomes plant including their periodical maintenance and repairs (excluding major assy/items/jobs as mentioned) all as specified in one shifts of 8 hours consisting of the following:-\n(a) Vertical type pressure filteration plant capacity 3500 Ltrs / hour with 1/2"thick nozzle, inlet, out let complete with filter media, GI Pipe sluice valve etc complete.\n(b) Pumping set monoblock centrifugal 5HP induction motor electric driven for pressure filter -2 Nos.\n(c ) Suction sweepr trolley mounted 2ft wide complete with centrifugal pump driven by electric motor 2HP 415V 50 cycles supply with DOL starter etc complete-2 Nos. \n(d) Water Softener - 01 No.\n(e) Alum dosing tank FRP material 8 gallons capacity with manual mixing arrangement inlet and outlet connection etc complete - 1 No\n(f) Air compressor 125 Cubic ft air per minute driven by 5HP induction electric motor 3 ph, 415 Volts 50Hz incl DOL starter etc complete - 1 No.\n(g) LT panel board suitable for 3 phase 415 Volts AC supply wall mounted and 100 Amps MCCB incoming LOCATION :MO (MB) GHATKOPAR.
35 10.01 Basic Rate (Wage) payable to the operators 335 Per Shift
36 10.02 Contribution towards EPF 335 Per Shift
37 10.03 Contribution towards ESIC 335 Per Shift
38 10.04 Contribution towards Bonus 335 Per Shift
39 10.05 Over Head and Profit on Srl item No. 10.01 to 10.04 335 Per Shift
40 10.06 Labour Welfare Cess payable on Srl item No 10.01 to 10.05 335 Per Shift
41 11 Notes for Srl No. 10.01 to 10.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 10.01, 10.02, 10.03, 10.04, 10.05 and 10.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
42 12 Manning and Operation of DG Set in two shifts per day (each shift 08 hrs continuous duration) operated by one operator in each shift including periodical maintenance/repairs (daily check and cleaning, monthly, quarterly, half yearly maintenance) with all consumables parts (except for major assembly/items/jobs as mentioned) of DG Set - Engine Make :- Kirloskar Cummins Make Greaves \nMake of alternator : Stamford, Capacity : 400KW/500KVA \nStaff employed : FGM - 01 No \nLocation :NS 09 MO MB Ghatkopar \n(i) Frist Shift - 0600 hrs to 1400hrs \n(ii) Second Shift - 1400 hrs to 2200 hrs\n
43 12.01 Basic Rate (Wage) payable to the operators 870 Per Shift
44 12.02 Contribution towards EPF 870 Per Shift
45 12.03 Contribution towards ESIC 870 Per Shift
46 12.04 Contribution towards Bonus 870 Per Shift
47 12.05 Over Head and Profit on Srl item No. 12.01 to 12.04 870 Per Shift
48 12.06 Labour Welfare Cess payable on Srl item No 12.01 to 12.05 870 Per Shift
49 13 Notes for Srl No. 12.01 to 12.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 12.01, 12.02, 12.03, 12.04, 12.05 and 12.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
50 14 Manning and Operation of the following items in three shifts per day (each shift 08 hrs continuous duration) operated by one operator and helper in each shift including periodical maintenance/repairs (daily check and cleaning, monthly, quarterly, half yearly maintenance) with all consumables parts (except for major assembly/items/jobs as mentioned) of Pump sets.\n(a) (i) Pumping set mono block 5 HP - 02 Nos. (ii) Sewage Pump 10 HP - 01 Nos. (iii) Electric LT panel \nLocation - New Management Complex at NSD Ghatkopar.\n(b) Fire Pump House Vikramaditya store House :\n(i) Fire Main Pump Set 75 HP three phase 415 V, Make :- Kirloskar -01 No\n(ii) Fire pump set 72 HP Diesel engine operated, Make :- Kirloskar -01 No\n(iii) Fire jockey pump set 7.5 HP , Make :- Kirloskar -01 No\n(iv) Fire priming/booster pump set 7.5 HP , Make :- Kirloskar -02 Nos\n(v) LT controll pannel and water pressure switch \nStaff employed : FGM - 01 No, Helper -01 No.\n(i) First Shift - 0600 hrs to 1400hrs\n(ii) Second Shift - 1400 hrs to 2200 hrs\n(iii) Third Shift - 2200 hrs to 0600 hrs
51 14.01 Basic Rate (Wage) payable to the operators 1005 Per Shift
52 14.02 Contribution towards EPF 1005 Per Shift
53 14.03 Contribution towards ESIC 1005 Per Shift
54 14.04 Contribution towards Bonus 1005 Per Shift
55 14.05 Over Head and Profit on Srl item No. 14.01 to 14.04 1005 Per Shift
56 14.06 Labour Welfare Cess payable on Srl item No 14.01 to 14.05 1005 Per Shift
57 15 Notes for Srl No. 14.01 to 14.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 14.01, 14.02, 14.03, 14.04, 14.05 and 14.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
58 16 Manning and Operation of the following items in three shifts per day (each shift 08 hrs continuous duration) operated by one operator and helper in each shift including periodical maintenance/repairs (daily check and cleaning, monthly, quarterly, half yearly maintenance) with all consumables parts (except for major assembly/items/jobs as mentioned) of Pump sets.\n(a) (i) Pumping set mono block 25 HP - 02 Nos. (ii) Electric LT panel \nLocation - Main pump House at NSD Ghatkopar.\n(i) First Shift - 0600 hrs to 1400hrs\n(ii) Second Shift - 1400 hrs to 2200 hrs\n(iii) Third Shift - 2200 hrs to 0600 hrs
59 16.01 Basic Rate (Wage) payable to the operators 1005 Per Shift
60 16.02 Contribution towards EPF 1005 Per Shift
61 16.03 Contribution towards ESIC 1005 Per Shift
62 16.04 Contribution towards Bonus 1005 Per Shift
63 16.05 Over Head and Profit on Srl item No. 16.01 to 16.04 1005 Per Shift
64 16.06 Labour Welfare Cess payable on Srl item No 16.01 to 16.05 1005 Per Shift
65 17 Notes for Srl No. 16.01 to 16.06 :-\n(a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, i.e. proof of payment.\n(b) The rates quoted shall be inclusive of all taxes, cess, levies as applicable including GST.\n(c) At the time of financial evaluation if quoted rate against Srl No. 16.01, 16.02, 16.03, 16.04, 16.05 and 16.06 which corresponds to/works out to lower than the corresponding prevailing minimum rates of wages/subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on bid submission end date.
66 18 SECTION-II COMPREHENSIVE REPAIR / MAINTENANCE
67 19 M&L for three pole contractor with 2 NO + 2NC Auxilary contacts for AC circuits type ML-2 standard coil voltage 415/440 volts complete all as specified and directed. Make: L&T/Siemens/ABB 1 Each
68 20 All as per srl item No 19 here in before but ML 1.5 complete all as specified and directed. Make: L&T/Siemens/ABB 1 Each
69 21 Supply only bimetal overload relay type ML range 20-32A, 415Volts directly operated complete all as specified and directed. Make: L&T/Siemens/ABB 1 Each
70 22 Supply and fixing shaft seal assembly with complete accessories for SMC 4-65 to SMC-8-65 complete all as specified and directed. Make ACCEL or equivalent as approved by GE 1 Each
71 23 Taking down existing supply and return air diffusers of any sizes cleaning with blowers and water painting with two coats of synthetic enamel paint and refixing in positions complete all as specified and directed. 4 Each
72 24 M&L for replacement of old safety valves of 1/2" 300 PSI operating pressure complete all as specified and directed. Make Brasomatic or equivalent as approved by GE 1 Each
73 25 Supply only pressure gauge 0 to 300 LBS/SQ inch complete all as specified and directed. Make Feibig/Adarsh 1 Each
74 26 Supply only bimetal overload relay type ML 1.5 range 10-15A, 415Volts directly operated complete all as specified and directed. Make: L&T/Siemens/ABB 1 Each
75 27 Supply and fixing of gun metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipes of 25 mm dia as specified and directed.Make.Leader ISI marked 1 Each
76 28 Supply and fixing of gun metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipes of 50 mm dia as specified and directed.Make.Leader ISI marked 1 Each
77 29 Taking down existing unserviceable cooling tower and supply install testing & commissioning of FRP induced draft cooling Tower of capacity 100TR inducing all accessories like FRP basin PVC fills, Nozzles, PVC water inlet header fan motor fan blade, fan bulb, fan shaft, GI nuts,/ bolts, MS Frame, FRP casing ladder etc. complete all as specified & directed. \nLocation- N.Make : Mihir\nLocation : S.S.K 47 AC PLANT MO Ghatkopar, Make : Mihir & Advance 1 Each Job
78 30 Taking down AC Plant compressor reciprocating open type Model No. 5H.40/60 Voltas Make by dismantling complete assembly for overhauling including replacement of unserviceable minor spares (rate included) including machining of crank shaft bearing polishing, replacing of gaskets packing reassembly and recharging of pumped down including replacement of major spares parts, refrigerant & topping up if required to maintain the required standing charged pressure of compressor oil complete testing for smooth functioning etc. complete all as specified and directed.\nLocation at S.S K47 -Vikramaditya / Ghatkopar \nNote: Compressor major spare parts, compressor oil and refrigerant for topping up will be paid separately under relevant items supply only. However labour element for replacing these major spares shall be deemed to be included in quoted rates. 2 Each Job
79 31 Supply only following spares parts for compressor Model-5H-40,Location:SSK-47 Make :-Voltas
80 31.01 Crankshaft 5H60 1 Each
81 31.02 Main bearing 4 Each
82 31.03 Connecting rod bearing half section 16 Each
83 31.04 Connecting rod 4 Each
84 31.05 Liner assembly 6 Each
85 31.06 Piston 6 Each
86 31.07 Piston Ring 15 Each
87 31.08 Oil ring 15 Each
88 31.09 Gudgeon Pin 10 Each
89 31.1 Oil pump assembly 2 Each
90 31.11 Suction Reeds 10 Each
91 31.12 Discharge reeds 10 Each
92 31.13 Suction valve plate 4 Each
93 31.14 Discharge valve plate 4 Each
94 31.15 Oil filter inner 2 Each
95 31.16 Suction strainer 2 Each
96 31.17 Loader rocker arm 8 Each
97 31.18 Loader power elements 6 Each
98 31.19 Shaft seal assembly 3 Each
99 31.2 Loader solenoid assembly 4 Each
100 31.21 Suction service valve 1 Each
101 31.22 Compressor safety valve 1 Each
102 32 M & L for disconnecting condensor for descalling & plugging them & providing of 15mm bore tee out let for local circulation of mild acid solution in the condenser (separate container & small pump set to circulate diluted acid solution to be used)PH value of solution shall be 4 and it should be checked frequently i.e every 1hour during the operation Scalgun WS solution to be used for descalling purpose after 2 to 3hours of cleaning if PH value remains less than 7 flush with fresh water added with sodium carbonateTube to be cleaned with nylone brush after closing the end covers circulate diluted acid solution as specified above & PH value toe be maintained as above by flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete as specified & directed for the AC plants following capacity:-
103 32.01 3 x 30TR Capacity (Location -SSK A7 NSD Ghatkopar ) 3 Each Job
104 32.02 3 x 22.5TR Capacity (Location - NS -26 Ghatkopar) 3 Each Job
105 32.03 3 x 50 TR Capacity (Location - Vikramaditya Ghatkopar ) 3 Each Job
106 32.04 3 x 11 TR capacity ( Location ILMS) 3 Each Job
107 32.05 1 x 7.5 TR Capacity (Location - Technical cell Ghatkopar) 1 Each Job
108 33 Preparation of old painted steel surface of AC Plant including scraping, cleaning and applying two coats of synthetic enamel paint of approved shed & colour over a coat of primer including marking and writing SM & MES No/ letters other details etc. complete all as specified and directed for AC plants of following capacities:-
109 33.01 3 x 30TR Capacity (Location -SSK A7 NSD Ghatkopar ) 1 Each Job
110 33.02 3 x 50TR Capacity (Location - Vikramaditya Ghatkopar ) 1 Each Job
111 34 Pumping down the existing refrigerant from the condensor and carrying out the leak test of plant with the pressure of Nitrogen gas and monoitoring for 24hrs asses leakages by brazing & replacement of necessary gasket wherever required including copper tubes of suitable size vacumizing of the plant by vaccum pump finally reharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed ( Note: Refrigerant required for topping up will be measured and paid separately under relevant items)\nLocation : MO Ghatkopar 2 Each
112 35 M & L for dismantling cooling tower by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed for the following capacity cooling towers.
113 35.01 Cooling tower of 100TR Capacity (Location- Vikramaditya Ghatkopar 1 Each Job
114 35.02 Cooling tower of 56TR Capacity(Location - NS-26 and NSD Ghatkopar 1 Each Job
115 35.03 Cooling tower of 80TR Capacity (Location- NS SSK47 NSD Ghatkopar) 1 Each Job
116 36 S & F in repairs thermostat of central AC plant of range 5 Degree centigrade to 25 Degree centigrade etc. complete with all acessories all as specified and directed 2 Each
117 37 All as per item No.36 but Sensor type . Make : Voltas 2 Each
118 38 S & F in repairs pilot solenoid valve from the liquid line suitable for AC Plant of various capacities etc. complete with all accessories all as specified and directed. 2 Each
119 39 S & F in repairs pressure gauges HP/LP/OP from existing position of following capacities etc. complete with all accessories all as specified and directed.
120 39.01 0-30 Kg/ cm2 2 Each
121 39.02 0-12.5Kg/ cm2 2 Each
122 39.03 0 to 16kg. 1 Each
123 40 Removing the unserviceable water pressure gauges from water line & supply and fix new pressure gauge capable to measure pressure upto 7kg/ Sqcm etc. complete with all accessories all as specified and directed. 5 Each
124 41 All as per item No. 40 above but for pressure upto 10Kg/ Sqcm 2 Each
125 42 S & F in repairs ball valve of cast steel flange type of size 40mm bore from the liquid line after pumping down the refrigerent and test for leakages etc. complete all as specified and directed. 2 Each
126 43 M & L for expansion valve of AC plant of capacity 25TR to 50TR including taking down unserviceable valve etc. complete all as specified and directed. 1 Each
127 44 M & L for replacement of Power contactor type ML-1.5etc. Complete all as specified and directed Make : L & T, Siemens 2 Each
128 45 M & L for replacement of Power contactor type 3TF46- 2etc. Complete all as specified and directed Make : L & T, Siemens Location :- SSK47 , Vikramaditya MO Ghatkopar 4 Each
129 46 M & L for replacement of Thermal Timer range GT-100, 9 to 30Sec adjustable type voltage 215/ 450V etc. complete all as specified & directed.( L & T/ Siemens or equivalent) 2 Each
130 47 All as per item No. 46 above but of range GT-200, 5 to 18Sec etc. complete all as specified & directed (Make: L & T/ Siemens or equivalent) 1 Each
131 48 Supply and fix in replacement single phase preventor type ES-100etc. Complete all as specified & directed.(Make : L & T/ Minilac or equivalent) 2 Each
132 49 S & F in replacement of following unserviceable / worn-out 'V' compressor AHU etc. of fenner or equivalent of Dunlop/ Nerlon
133 49.01 "V" Belt (B-76) 4 Each
134 49.02 "V" Belt (B-68) 2 Each
135 49.03 "V" Belt (B-108) 4 Each
136 49.04 "V" Belt (B-85) 4 Each
137 50 Material & Labour for replacement of unserviceable HP cut out MP 5 etc. complete all as specified & directed. 2 Each
138 51 All as item No. 50 but Sensor type MO Ghatkopar 3 Each
139 52 Material & Labour for replacement of unserviceable LP cut out MP 1 etc. complete all as specified & directed. 3 Each
140 53 All as item No. 52 but Sensor type 3 Each
141 54 Material & Labour for replacement of unserviceable oil pressure cut out controls for compressor etc. complete all as specified & directed. 2 Each
142 55 All as per Sr. No. 54 but Sensor type 2 Each
143 56 Material & Labour for replacement of the defective indicator lamp LED type etc. complete all as specified & directed 12 Each
144 57 M & L for replacement of following unserviceable / defective existing ampere meter digital type with CT of size 96 x 96mm etc. complete all as specified & directed.
145 57.01 0 to 50A 1 Each
146 57.02 0 to 30A 1 Each
147 57.03 0 to 20A 1 Each
148 58 Pumping down compressor model SMC -4- 65 to make : ACCEL to replace the shaft seal assembly and replace the same with new assembly and recharge the compressor all as specified and directed by Engineer- in -charge 2 Each
149 59 Removing defective unserviceable coil of loader solenoid valve from the system of compressor of make : ACCEL model SMC -4-65/6-65 Including supplying and fixing new coil of loader suitable to the existing system all as specified and as directed. 1 Each
150 60 Supply only lubricating oil Freezol-36 or equivalent for top up of compressors of AC plants all as specified and directed 100 Ltrs
151 61 Supply only refrigerent (R-22) gas for top up etc. complete all as specified and directed 65 Kg
152 62 All as Item No. 61 but R407C complete all as specified and directed 25 Kg
153 63 M & L for disconnecting cooling coil section of AHU for descaling & Plugging them & providing 15mm bore tee out let for local circulation of mild acid solution in the condenser (separate container & small pump set to circulate diluted acid solution to be used) PH value of solution shall be 4 and it should be checked frequently i.every 1hour during the operation Scalgun WS solutionto be used for descaling purpose after 2 to 3hours of cleaning if ph value remains less than 7flush with nylon brush after closing the end covers circulate diluted acid solution as specified above & PH value to be maintained as above by flushing the same with fresh water incl recharging of stored refrigerant up to required pressure etc. complete all as specified & directed for the cooling coil section of AHU plants of following capacity:- \nNotes: i) The solution should be warmed up to 35oC by immersion of heater\nii) It should be ensured during the entire process of cleaning the PH value of insulating water shall be 7\niii)Rate quoted against the items deemed to be included solution for decaling, rubber gasket washer, nuts, bolts, etc. as applicable)
154 63.01 AHU of 1 x 22.5TR Capacity (Location- NS-26 Ghatkopar) 1 Each Job
155 63.02 AHU of 1 x 60TR Capacity (Location- SSK47 Ghatkopar) 1 Each Job
156 63.03 AHU of 1 x 100TR Capacity (Location- Vikramaditya Ghatkopar) 1 Each Job
157 64 S & F in repairs unserviceable hermetically sealed compressor reciprocating type 5.5TR working on R-22, 3Phase , 407V including brazing and electric/ piping connection etc. complete all as specified & directed(Location :- Ghatkopar 1 Each Job
158 65 S & F in repair AHU pre air filter 10 micron 80% efficiency as per exising model size
159 65.01 600X 608 X 50 mm SSK 47AC PLANT GHATKOPAR 4 Each Job
160 65.02 610X 610 X 45 mm Vikramaditiya GHATKOPAR 4 Each Job
161 66 S & F in unserviceable micro-Processors with display-L-5.5K47-Ghatkopar 1 Each Job
162 67 S & F in unserviceable MVPP Location: NSD Ghatkopar 1 Each Job
163 68 S & F in unserviceable liquid line, Drier filter 1/2" size, Make Danfoss Location, Ghatkopar 2 Each Job
164 69 Material & Labour for replacement of the defective cable, 3core, 2.5Sqmm Location -SSK 47 Ghatkopar 30 RM
165 70 M & L for replacement of the defective AHU duct canvas2.5feet square Location: NSD Ghatkopar 3 Each Job
166 71 Pumping down compressor model 5H-40/60 Make :Voltas for replacing the shaft seal assembly and replacing the shaft seal assembly and replacing the same with new assembly and recharging the compressor all as specified and directed . 2 Each Job
167 72 Annual maintenance of water coolers of bluestar make Model No. SWCSDLX6080UVE installed at Naval Depot Area ghatkopar to check water quality, opreventive and breakdown maintenance, lubrication, , power supply, repair and replacement of filter candles time to time and the water cooler under contract will be serviced for times during the contract time as per standard checklist ,compressor will be checked for its proper functioningAll breakdown calls will be attended to during the contract period,The Blower motor will be checked,the driver set of the blower section wll be inspected but tension adjusted and belts changed,Any defects in the electrical item and control wiring will be attended during contract period.cost of spare parts/consumables required shall be borne as per type of contract and shall be applicable to all activities specified under contract etc complete all as specified and directed. 26 Each
168 73 Dismantling of existing defective unserviceable compressor of any capacity from window or split AC, Refrigerators, water coolers etc complete all as specified and directed. 5 Each
169 74 Supply & Fix new hermetically sealed compresor in existing window type AC, 1.5 Ton capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connection etc complete all as specified and directed, Make : Voltas / Shriram/Tecumseh/Kirloskar / Hitachi/LG / Blue Star. 1 Each
170 75 All as per item No. 74 above but for split type AC 1.5 Ton capacity. 2 Each
171 76 All as per item No. 74 above but for Refrigerator exceeding165 Ltr and upto 310 Ltr Capacity. 1 Each
172 77 All as per item No. 74 above but for Water Cooler Blue star make 80 Litres capacity. 2 Each
173 78 all as per item No. 74 above but for Water Cooler Blue Star Make 80/120 Litres capacity and 60/120 Litres capacity.\nNote : (i) The Contractor shall submit original purchase voucher alongwith manufacturer's test certificate and Guarantee Card etc. (ii) The quoted rates shall also be deeed to include to undertake Guarantee of one year from certified dated of completion by the contractor for free replacement of compressor and/or rectification of the same (including charging of gas) all as directed by the GE in case any defects are noticed (during Guarantee Period of 01 year) due to any reasons whatsoever may be. 1 Each
174 79 Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 2 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and including servicing, overhauling and connecting of refrigerant pipe,drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed. \nNOTE : (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only. 50 Each Job
175 80 Replacement of fan blades of motor for water cooler upto 80 Ltr capacity including testing etc complete all as specified and directed 3 Each Job
176 81 Replacement of fan motor of water cooler up to 80 Ltr capacity including testing etc complete all as specified and directed. 2 Each Job
177 82 Supply only running capacitor of 36 MFD complete all as specified and directed.\n 15 Each
178 83 Supply only refrigerent (R-22) gas for top up etc. complete all as specified and directed 15 Kg
179 84 Supply only refrigerent R-407C gas for top up etc complete all as specified and directed 5 Kg
180 85 Replacement of relay for Water Cooler of Bluestar Make 80 Litre storage capacity, complete all as specified and directed. 2 Each
181 86 Replacement of relay for Refrigerator 165 to 310 Litre Capacity, complete all as specified and directed. 1 Each
182 87 Taking out existing unserviceable thermostat switch of water cooler and Supply & fix new thermostat switch for water cooler of any capacity including testing etc complete all as specified and directed. \n(Make:INDOFOSS/RANUTRAL)\n 2 Each
183 88 Taking out existing unserviceable thermostat switch of refrigerator and supply & fix new thermostat switch for refrigerator of any capacity including testing etc complete all as specified and directed. \n(Make : INDOFOSS/RANUTRAL)\n 1 Each
184 89 Supply and fix in repairs blower motor capacitor 4 MFD etc complete all as specified and directed. (Make : ASIAN/KEIL/EPCOS)\n 2 Each
185 90 All as per item No. 89 above but 6 MFD capacitor. (Make: ASIAN/KEIL/ EPCOS) 3 Each
186 91 Supply only over load protector No 1022 in window type AC upto 2 ton capacity complete all as specified and directed.(Make : USHA/ RANUTRAL)\n 1 Each
187 92 Taking out existing unserviceable over load relay and supply & fix new over load relay in water cooler upto 80 ltrs capacity etc complete all as specified and directed. 5 Each
188 93 Taking down carefully split type AC upto 2 Ton capacity & refixing inner & outer unit at new location alongwith existing frame work, bracket, refrigerant tubing, cable, stablizer etc and making good existing surface to match with the adjoining surfaces etc complete all as specified and directed. 5 Each
189 94 Supply, fixing, clamping and jointing copper tubing in replacement of 3/8" dia for suction line and for liquid discharge line duly insulated with suitable insulation material for split AC including necessary soldering, flaring work, jointing, testing etc, making hole in wall for passing though pipe and making good to the disturbed surface to match with the adjoining surfaces etc complete all as specified and directed. 20 RM
190 95 Supply & Lay PVC Nylon braided pipe 20 mm bore heavy duty including fittings to drain out condensed water of split AC including cutting of floor / wall & making good after laying of pipe to match the existing surface etc complete all as specified and directed. 10 RM
191 96 Supply & fix in repair, push cock / lift cock 15mm bore of brass, chromium plated, ISI marked for water cooler of any capacity etc complete all as specified and directed. 24 Each
192 97 Supply and fix water tray made out of GI sheet 2 mm thick for water cooler any capacity with out let system connection provided with and including PVC nylon braided pipe of 20 mm dia upto 3 mtr length and also connecting to drain pipe etc complete all as specified and directed. 3 Each
193 98 Removing existing unserviceable electronic circuit control board of split AC unit upto 2 ton capacity and supply and fixing new electronic PCB & display board kit in the indoor unit including testing etc complete all as specified and directed. 2 Each Job
194 99 Supply and fixing filter media sediment for water cooler complete all as specified and directed. 25 Nos
195 100 Supply and fixing Carbon filter for water cooler complete all as specified and directed. 25 Nos
196 101 Supply only remote sensor handset suitable for split AC upto 2.0 ton capacity etc complete all as specified and directed. 2 Each
197 102 Supply and fix in repair remote sensor plate suitable for split AC upto 2.0 ton capacity etc complete all as specified and directed. 2 Each
198 103 Supply and fix in repairs multipurpose door lock with duplicate key of water cooler of any make & capacity etc complete all as specified and directed. 2 Each
199 104 Dismantling of Monoblock pump of under mentioned capacities from connected suction/ delivery pipes and electric connections etc, taking to workshop. overhauling of the same and replacing unserviceable spares/parts/components, cleaning of impeller, greasing, reassembling, bringing back from workshop to the site, refixing in original position including providing packing, necessary nuts & bolts etc, and reconnecting, recommissioning and testing for smooth functioning.\nLocation : NCHC Hospital\n(Note: Cost of all the elements (material cost as well as labour cost) for making the pumps completely functional except supply only of the spares/components/parts included in this item shall be deemed to be included in the quoted rates).\n
200 104.01 3 HP Capacity 2 Each Job
201 104.02 7.5 HP Capacity 1 Each Job
202 105 Supply only following spares /components/parts for monoblock pump set all as specified and directed :-
203 105.01 Gun metal bushes for 3 HP capacity 2 Each
204 105.02 Gun metal bushes for 7.5HP capacity 1 Each
205 105.03 Bearing for 3 HP capacity 2 Each
206 105.04 Bearing for 7.5HP capacity 1 Each
207 105.05 Water seal packing for 3 HP Capacity 2 Each
208 106 Rewinding of unserviceable electric motor 3 phase, 50 Hz, 415 Volt of following capacity pump set complete comprises as under :- \n(a) Disconnecting & removing the electric motor from installed position including loading, unloading and transporting to approved workshop.\n(b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including provision of all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. \n(c) Transporting the motor back to the location, reinstalling in original position including making alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. \nLocation : NCHC Hospital
209 106.01 Motor of capacity 3 HP 2 Each Job
210 106.02 Motor of capacity 7.5HP (AHU Blower ) 1 Each Job
211 107 M & L for disconnecting condenser for descalling, plugging them & providing 15mm bore tee outlet for local circulation of mild acid solution in the condenser (separate container & small pump set to circulate diluted acid solution shall be used)PH value of solution shall be 4 and it shall be checked frequently i.e every 1hour during the operation, Scalgun WS solution shall be used for descalling purpose after 2 to 3hours of cleaning if PH value remains less than 7, flush with fresh water added with sodium carbonateTube, to clean with nylon brush, after closing the end covers circulate diluted acid solution as specified above & PH value to maintained as above by flushing the same with fresh water including recharging of stored refrigerant upto required pressure complete all as specified & directed for 2 x 11 TR capacity of AC plants :- (Location-NCHC Hospital) 2 Each
212 108 Pumping down the existing refrigerant from the condenser, carrying out the leak test of plant with the pressure of Nitrogen gas and monitoring for 24hrs, assess leakages by brazing & replacement of necessary gaskets wherever required including copper tubes of suitable sizes, vacumizing of the plant by vaccum pump, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed.\nNote: Refrigerant required for topping up will be measured and paid as supply only separately under relevant item. However, cost of all the other elements as specified above including replacement of gaskets, copper tubes etc for making the condensor functional shall be deemed to be included in the quoted rate of above item.\nLocation : NCHC Hospital\n 2 Each Job
213 109 M & L for dismantling cooling tower of undermentioned capacity by removing CT Fans, sprinklers, PVC filler, cleaning cooling tower body by removing scale, dust, dirt, refixing PVC filler after cleaning with diluted HCL solution, reassembling, connecting,cleaning external surfaces and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed :-\nCooling tower 2 x 11TR Capacity (Location- NCHC Hospital) 1 Each Job
214 110 S & F in repairs Sensor type thermostat of central AC plant of range 5 Degree centigrade to 25Degree centigrade complete with all accessories, as specified and directed, Make : ANERGY / SIEMENS / HONEYWELL / JOHNSON 2 Each Job
215 111 Removing the unserviceable water pressure gauges from water line & supply and fix new pressure gauge capable to measure pressure upto 7kg/ Sqcm etc. complete with all accessories, as specified and directed, Make : FIEBIGH / H.GURU / BAKER MERCER. 2 Each Job
216 112 All as per item No. 111 above but for pressure upto 10Kg/ Sqcm 1 Each Job
217 113 S & F in repairs for expansion valve of AC plant of capacity 15 TR to 25 TR, complete all as specified and directed, (Location-NCHC Hospital 1 Each Job
218 114 M & L for replacement of Power contactor type ML-1.5, complete all as specified and directed, Make : L & T, Siemens 1 Each Job
219 115 M & L for replacement of Power contactor type ML- 2, complete all as specified and directed, Make : L & T, Siemens 1 Each Job
220 116 M & L for replacement of Thermal Timer range GT-100, 9 to 30Sec adjustable type voltage 215/ 450V, complete all as specified & directed, (Make : L & T/ Siemens) 1 Each Job
221 117 Supply and fix in replacement single phase preventer type ES-100, complete all as specified & directed, (Make : L & T/ Minilac) 1 Each Job
222 118 S & F in replacement of unserviceable / worn-out "V" Belt (B-85) of compressor, AHU etc. of Make : Dunlop/ Nerlon :- 4 Each
223 119 Material & Labour for replacement of unserviceable Sensor type HP cut out, complete all as specified & directed, Make : PENN / INDOFOSS / RANCO / DANFOSS / JOHNSON. 1 Each
224 120 M&L replacement of unserviceable LP cut out, Sensor type, complete all as specified & directed, Make : PENN / INDOFOSS / RANCO / DANFOSS / JOHNSON. 2 Each
225 121 Material & Labour for replacement of the defective indicator lamp LED type, complete all as specified & directed, Make : SIEMENS / CONCORED / C&S / L&T. 4 Each
226 122 M&L for replacemetn of existing unserviceable/defective multifunctional meter, digital type of size 96 x 96mm with and including CT, complete all as specified and directed, Make : L&T (RISHAB) / TRINITY / C&S / L&T. 1 Each
227 123 M & L for replacement existing unserviceable / defective ampere meter with new digital type, 0-30 Ampers of size 96 x 96mm with and including CT, complete all as specified & directed, Make : AE / ENERCON / SECURE / L&T 1 Each
228 124 Supply only refrigerant (R-407C) gas for topping-up complete all as specified and directed, Make: MAFRON / FREON. 35 Kg
229 125 Removing old unserviceable globe valve and S & F new CI globe valve with nuts, bolts, washer, new gaskets etc. of 50 mm bore sizes complete all as specified & directed, Make: ADVANCE / AUDCO / SANT / BIR. 2 Each
230 126 S & F in repairs MVPD, complete all as specifed and directed, Location - NCHC Hospital 1 Each
231 127 S & F in repairs liquid line, Drier filter 1/2" size, Make DANFOSS / EMERSON / CASTLE, Location: NCHC Hospital 2 Each
232 128 M & L for Cleaning complete DX type cooling coil of AHU with chemical solution caustic soda to remove impurities completely, dust and foreign materials with nylon brush and cleaning cooling coil with fresh water, complete all as specified & directed for the cooling coil section of AHU of 2 x11TR Capacity (Location :- NCHC Hospital 1 Each Job
233 129 S & F in repairs unserviceable hermetically sealed compressor reciprocating type 5.5 TR working on R-22, 3Phase , 415V including brazing and electric/ piping connection etc. complete all as specified & directed, Make : COPLAN / EMERSON / BLUE STAR. Location :-NCHC Hospital 1 Each Job
234 130 Supply and fix in repairs, MCCB, TP, 25 to 100 Amps, 415 Volt, 50 Hz, breaking capacity 16 KA, fixed type, Complete all as specified and directed. 1 Each
235 131 Supply and fix in repairs MCCB, TP, 125 Amps, 415 Volt, 50 Hz, breaking capacity 16 KA, fixed type, Complete all as specified and directed. 1 Each
236 132 M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected with and including 32 x 6mm galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No. 3 and earthing strip connected to earthing test point all as specified and directed, including provision of mild steel frame, CI cover, PCC chamber, funnel with watering pipe, wire mesh and lugs etc, GI protection pipe of size 40mm bore light grade laid in trench, fixed on wall, floor etc, including testing on completion and dismantling of existing earthing set.\nNote: Cost for provision of GI strip and 40mm bore potection pipe upto 7.50 metre shall also be deemed to be included in the quoted rate. 1 Each Set
237 133 Dismantling of existing defective unserviceable compressor of any capacity from window or split AC, Refrigerators, water coolers etc complete all as specified and directed. 21 Each
238 134 Supply & Fix new hermetically sealed compressor in existing window type AC, 1.5 Ton capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connection etc complete all as specified and directed. 2 Each
239 135 All as per item No. 134 above but for split type AC 1.5 Ton capacity 4 Each
240 136 All as per item No. 134 above but for split type AC 2 Ton capacity. 3 Each
241 137 All as per item No 134 above but for refrigerator 165 ltrs to 310 ltr Capacity. 2 Each
242 138 All as per item No. 134 above but Water Coolers 40 / 80 Ltrs Capacity. 2 Each
243 139 Taking out window type air conditioner of capacity upto 2 TR of any make/type after disconnecting of electric supply and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and including servicing,overhauling and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed. 2 Each Job
244 140 Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 2 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and including servicing, overhauling and connecting of refrigerant pipe,drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed. \nNOTE FOR ITEM NOS. 139 & 140 : (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only." 10 Each Job
245 141 Replacement of corroded body base tray & connected portion of window type AC upto 2 Ton capacity (base tray made out of M S Sheet 18 BG and other portion with MS sheet 20 BG) including motor mounting frame, nuts/bolts of suitable size and spray painting with two coats of synthetic enamel paint over one coat of primer including replacement of damaged insulation etc complete all as specified and directed. Note : For replacement of the body, cost of dismantling of compressor etc including reassembling and gas charging etc as required at site shall also be deemed to be included in the quoted rates. 2 Each Job
246 142 Supply only blower fan motor for 1.5 TR capacity window type air conditioner complete all as specified and directed. 2 Each
247 143 Supply only blower fan blade for 1.5 TR window type air conditioner complete all as specified and directed. 2 Each Job
248 144 Supply only blower drum of window type AC upto 1.5 ton capacity complete all as specified and directed. \n 1 Each Job
249 145 S&F in repairs of blower fan motor for 1.5 TR capacity window type air conditioner complete all as specified and directed. 2 Each
250 146 S&F in repairs of blower fan blade for 1.5 TR window type air conditioner complete all as specified and directed. 2 Each Job
251 147 S&F in repairs of blower drum of window type AC upto 1.5 ton capacity complete all as specified and directed. \n 1 Each Job
252 148 Supply only relay for window type AC upto 1.5 Ton capacity complete all as specified and directed. 4 Each
253 149 Supply only over load protector in window type AC upto 1.5 ton capacity complete all as specified and directed. 1 Each
254 150 Supply only selector switch push button type for window type AC upto 1.5 Ton capacity complete all as specified and directed. 1 Each
255 151 All as per item No. 150 above but selector switch rotary type complete all as specified and directed. 1 Each
256 152 Supply only blower fan motor upto 2.0 TR capacity spilt type air conditioner complete all as specified and directed. 6 Each
257 153 Supply only blower drum of split type AC upto 2.0 ton capacity complete all as specified and directed. \n 5 Each Job
258 154 Supply only outdoor motor upto 2.0 TR split type air conditioner complete all as specified and directed. 6 Each Job
259 155 Supply only outdoor fan blade upto 2.0 TR split type air conditioner complete all as specified and directed. 5 Each Job
260 156 S&F in repairs of blower fan motor upto 2.0 TR capacity spilt type air conditioner complete all as specified and directed. 5 Each
261 157 S&F in repairs of blower drum of split type AC upto 2.0 ton capacity complete all as specified and directed. \n 5 Each Job
262 158 S&F in repairs of outdoor motor upto 2.0 TR split type air conditioner complete all as specified and directed. 6 Each Job
263 159 S&F in repairs of outdoor fan blade upto 2.0 TR split type air conditioner complete all as specified and directed. 5 Each Job
264 160 Supply only thermostat switch for window type/split type AC upto 2 Ton capacity complete all as specified and directed. 5 Each
265 161 S&F in repairs of thermostat switch for window type/split type AC upto 2 Ton capacity complete all as specified and directed. 5 Each
266 162 S&F in replacement air filter pad suitable for any type AC 1.5/2.0 ton capacity complete all as specified and directed. 10 Each
267 163 S&F in replacement condensing coil assembly suitable upto 2.0 Ton capacity window/split AC complete all as specified and directed. 2 Each
268 164 S&F in replacement cooling coil assembly suitable upto 2.0 Ton capacity window/split AC complete all as specified and directed. 2 Each
269 165 Replacement of PVC cover grill of window type AC upto 1.5 ton capacity complete all as specified and directed. 1 Each Job
270 166 Replacement of existing damaged outer cover of window type AC with 20 SWG aluminium anodised sheet including moulding, screwing etc complete all as specified and directed. 1 Each
271 167 Taking out corroded body & frame of water cooler of 80 Litres storage capacity and replacement with new angle iron frame of size 40 x 40 x 6mm and cooler body with MS/CRCA sheet of 20 gauge, painting with two coats of synthetic enamel paint over a coat or red oxide primer by spray painting, including reassembleing & refixing of all parts etc complete all as specified and directed . 2 Each Job
272 168 Taking out corroded body & frame of Refrigerator of 165 Litres Capacity & replacing refrigerator body with MS/CRCA sheet 20 gauge duly painted with 2 coats of synthetic enamel paint over a cot of red oxide primer by spray painting including reassembling and refixing all the parts etc complete all as specified and directed. 2 Each Job
273 169 All as per item No. 168 above but for Refrigerator more than 165 Litres but upto 310 Ltr Capacity complete all as specified and directed. 2 Each Job
274 170 Replacement of fan motor of water cooler up to 150 Ltr capacity including testing etc complete all as specified and directed. 2 Each Job
275 171 Replacement of fan blades of motor for water cooler upto 150 Ltr capacity including testing etc complete all as specified and directed 2 Each Job
276 172 Supply only starting capacitor 60 to 80 MFD complete all as specified and directed. 3 Each
277 173 Supply only starting capacitor 80 to 100 MFD complete all as specified and directed. 2 Each
278 174 Supply only starting capacitor 100 to 120 MFD complete all as specified and directed. 4 Each
279 175 Supply only running capacitor of 55 MFD complete all as specified and directed. 4 Each
280 176 S&F in repairs of starting capacitor 60 to 80 MFD complete all as specified and directed. 6 Each
281 177 S&F in repairs of starting capacitor 80 to 100 MFD complete all as specified and directed. 8 Each
282 178 S&F in repairs of starting capacitor 100 to 120 MFD complete all as specified and directed. 6 Each
283 179 S&F in repairs of running capacitor of 55 MFD complete all as specified and directed. 8 Each
284 180 Replacement of relay for Water Cooler of 60 to 150 Litre storage capacitycomplete all as specified and directed. 4 Each
285 181 Replacement of relay for Refrigerator 165 to 310 Litre Capacitycomplete all as specified and directed. 2 Each
286 182 Taking out existing unserviceable thermostat switch of water cooler and Supply & fix new thermostat switch for water cooler of any capacity including testing etc complete all as specified and directed. (Make:INDOFOSS/RANUTRAL) 2 Each
287 183 Taking out existing unserviceable thermostat switch of refrigerator and supply & fix new thermostat switch for refrigerator of any capacity including testing etc complete all as specified and directed. (Make : INDOFOSS/RANUTRAL) 1 Each
288 184 Supply and fix in repairs blower motor capacitor 4 MFD etc complete all as specified and directed. (Make : ASIAN/KEIL/EPCOS) 5 Each
289 185 All as per item No. 184 above but 6 MFD capacitor complete all as specified and directed. (Make: ASIAN/KEIL/ EPCOS) 3 Each
290 186 Taking out existing unserviceable over load relay and supply & fix new over load relay in water cooler upto 150 ltrs capacity etc complete all as specified and directed. 5 Each
291 187 Taking out existing unserviceable door gasket and supply & fix new door gasket for refrigerator upto 310 ltrs capacity etc complete all as specified and directed. 2 Each
292 188 S & F in repairs sheet metal enclosure in repair with 3 pin 20 Amp earth plug & socket, also with and including single pole MCB of 20 Amps etc complete all as specified and directed. 10 Each
293 189 Taking down existing unserviceable cable on wall/ceiling and supply and lay 1100 Volt grade PVC insulated 3 core 4 Sqmm stranded copper conductor cable suitable for indoor unit to outdoor unit complete all as specified and directed. 40 RM
294 190 Supply, fixing, clamping and jointing copper tubing in replacement of 3/8" dia for suction line and for liquid discharge line duly insulated with suitable insulation material for split AC including necessary soldering, flaring work, jointing, testing etc, making hole in wall for passing though pipe and making good to the disturbed surface to match with the adjoining surfaces etc complete all as specified and directed. 30 RM
295 191 Supply & lay PVC pipe 20 mm dia heavy duty including fittings to drain out condensed water of split AC including cutting of floor / wall & making good after laying of pipe to match the existing surface etc complete all as specified and directed. 30 RM
296 192 Supply & fix push cock / lift cock 15mm bore of brass, chromium plated, ISI marked in repair for water cooler of any capacity etc complete all as specified and directed. 2 Each
297 193 Supply and fix water tray made out of GI sheet 2 mm thick for water cooler any capacity with out let system connection provided with and including PVC pipe connecting to drain pipe etc complete all as specified and directed. 2 Each
298 194 Removing existing unserviceable electronic circuit control board of split AC unit upto 2 ton capacity and supply and fixing new electronic PCB & display board kit in the indoor unit including testing etc complete all as specified and directed. 2 Job
299 195 Supply only remote sensor handset suitable for split AC upto 2.0 ton capacity etc complete all as specified and directed. 4 Each
300 196 Supply and fix in repair remote sensor plate suitable for split AC upto 2.0 ton capacity etc complete all as specified and directed. 2 Each
301 197 S & F in repairs 15mm bore gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes etc complete all as specified and directed. 3 Each
302 198 S & F in repairs 15mm bore ball brass valve high pressure with polythene float & fly nut screwed for iron pipes etc complete all as specified and directed. 5 Each
303 199 Supply only refrigerant (R-22) gas as per requirement complete all as specified and directed. 20 Kg
304 200 Testing of entire Fire alarm system at each store for functionality test and carrying out preventive maintenance of the Panel. Checking of Voltage supply to all cards, battery health checking,\nlamp test of Panel, checking of History log of Alarm and trouble. Clearing of temp files from Graphics panel, checking of network communication and cable checking for proper signal\ntransmission. Checking of detector, hooter, MCP, Weather proof hooter, Weather proof MCP Isolator, network repeater and it communication. Graphics system checking for proper\nfunctionality and maintaining the log book for the test carried out. Test shall consist of Visual inspection and functionality test complete all as specified and directed. 15 Each Set
305 201 Monthly corrective and remedy maintenance service to set rights the malfunctions of the system. This may include replacement of unserviceable parts. Parts replaced will either be New parts or parts equivalent in performance to new parts. Visit will consist of one engineer and 2 technicians. Spare parts/Component will be paid separately complete all as specified and directed 11 Months
306 202 Supply installation testing & commissioning of AMPS-24E for Fire alarm panel, It shall be fully compatible with the existing Fire panel of Notifier make with following specification - 240\nVAC 50/60 Hz input, 2.25 A maximum • One 5 VDC @ 1.0 A - nonpower-limited output - TB6 One 24VDC @ 1.0 A - nonpower- limited output - TB6 Power-limited if 5V output is not used.\nMaximum Ripple Voltage (24 VDC & 5VDC): 250 mVrms • One 24 VDC @ 4.5 A - filtered, nonpower-limited source - TB2 Maximum output:4.2 A when 5V output (TB6) is used. 3.5 A when 24V output (TB6) is used. 3.2 A when both outputs on TB6 are used.Maximum Ripple Voltage: 250 mVrms complete all as specified and directed Make Notifier 1 Each Job
307 203 Supply, Installation, Testing and commissioning of CPU Card for Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events. It should be compatible to panel\nequipped with sufficient numbers of. Card shall have loop capacity of minimum 150 analog addressable devices. It should support the panel to work in degrade mode. Four access levels,\ninbuilt flash EPROM complete all as specified and directed Make Notifier. 1 Each Job
308 204 Supply, installation, testing and commissioning of loop card of 150 point for NFS 3030 Fire alarm panel. It should be programmable by laptop at site. The card should be compatible to the existing system and device in the network. Its functionality should not adversely affect the installed system\nand shall be complete as specified and directed. Make : Notifier 1 Each
309 205 Supply, installation, testing and commissioning Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-color LED for 360 deg viewing. Addressing\nshall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition complete all as specified and directed Make Notifier 38 Each
310 206 Supply, installation, testing and commissioning of Intrinsically safe Photoelectric Smoke Detector with Zener barrier and all necessary accessories sensitivity range of 0.5 to 3.7% obs/ft. The\ndetector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches complete all as specified and directed Location: Paint Storage shop 1 Each Job
311 207 Supply, installation, testing and commissioning Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete all as specified and directed Make: Notifier 1 Each
312 208 Supply installation testing and commissioning Addressable Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication all as directed and specified 1 Each
313 209 Supply and fixing in repairs Fire Exit Signage’s, complete all as specified and directed, Make :Prolite Autoglow 6 Each
314 210 Supply and fix in repairs Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,) \n 5 Each Set
315 211 Supply and fix in repairs Isolators complete all as specified and directed 4 Each Job
316 212 Supply and fix in repairs Cast iron wafer end type Butterfly valves (standard lever operated type for 150 mm dia. and below and gear operated type for 200 mm and above dia.) butterfly valves as per BS 5155/ IS 13095 (PN 10) having nylon coated CI disc, nitrile rubber seat complete with matching flanges, gaskets, galvanised fasteners.
317 213 150 mm nominal dia 1 Each
318 214 100 mm nominal dia 2 Each
319 215 80 mm nominal dia 1 Each
320 216 Supply and fix in repairs Forged brass screwed ends full bore ball valves (min PN 10 rating) with suitable fittings of screwed end type complete 25NB complete all as specified and directed 1 Each
321 217 Supply and fix in repairs Reinforced rubber lined fire hose as per IS: 636 (Type A) with stainless steel couplings as per IS: 903, 7.5m long for internal hydrants complete all as specified and directed. 5 Each
322 218 supply and fix in repairs Swinging type first aid fire hose reel drum comprising of reinforced rubber tubing of 20 mm dia and following lengths conforming to IS :444 Type II, MS drum with fixing bracket conforming to IS:884 & with 5 mm dia gun metal shut off nozzle conforming to IS:8090 and 25NB forged brass valve. (30 meters Hose length) 6 Each
323 219 Supply and fix in repairs 63 mm x 20 mm stainless steel branch pipe and nozzle as per IS:903 to be connected to hose coupling 3 Each
324 220 Supply and fix in repairs Weather proof outdoor lockable hose cabinet made of 14 SWG CRCA MS Sheet with 2 doors and 4 mm thick glazed glass with water proof rubber beading. it shall be in red outside and white inside with two coats of enamel paint over a coat of primer. "HOSE CABINET NO.." shall be painted on the inner face of the glass in 50 mm size block letter. Cost shall include the cost of break glass box containing the key of the cabinet. Size 600(H) x 750(L) x 250(D) mm complete all as specified and directed. 6 Each Job
325 221 Supply and fix in repairs Fire brigade inlet connection of 4 way with 4 nos 63 mm dia stainless steel outlet, built in check valve complete as per specification. Rate shall include cost of 1 no 150NB butterfly valve and one no cabinet to house the inlet connection only. 1 Each
326 222 Supply & fixing in repairs gun metal Fire internal Hydrant single landing valve with 80 mm N.B. flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. G.M. coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290. Including fixing with anchor fastener and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required. 2 Each
327 223 Supply only copper sulphate of super quality ISI Marked complete all as specified and directed. 100 Kg
328 224 Supply only aluminium potash of super quality ISI Marked complete all as specified and directed. 500 Kg
329 225 Supply only Soda Ash of super quality ISI Marked complete all as specisified and directed. 400 Kgs
330 226 Supply only Calcium hyppchloritein Garnual Calcium Based Chlorine usefull for Disinfection Of Drinking Water treatment. These highly concentrated solid calcium hypochlorite products deliver upto 70% available chlorine. conforms to BS EN 900:2007 (Chemicals used for treatment of water intended for human consumption - calcium hypochlorite make:Altoch GP 850 Kgs
331 227 Supply only stable bleaching powder (calcium hypochloride with chlorine content not less than 30%) as per IS: 15738 : 2007 and 1065 : 1989 Marke : M/s Sree Rayalaseema Hi-Strength Hypo Ltd or Grasim industries Ltd or Bengal Chemichal & Pharmaceuticals. 850 Kg
332 228 Testing of water Supply and obtain the following the research and tested through NABL accredited Lab including submitting of test certificate to Engineer – in Charge complete all as specified. Details of tests to be carried out (i) Turbidity (NTU), (ii) PH, (iii) Total Hardness CaCO3 (mg/l), (iv) Sulphate (SO4) (mg/l), (v) Iron (Fe) (mg/l), (vi) Magnesium (Mg) (mg/l), (vii) E-coli or thermo tolerant coliform bacteria Note: The rate quoted deemed to include the cost of collecting sample of water in four different locations from MO (MB) Ghatkopar and the test to be carried out in the first and seventh month of the contract. 16 Each
333 229 Taking down unserviceable suction sweeper motor pump set 5Hp capacity, dismantling the pump side and replacing the worn out shaft, bearings, bush and coupling rubber bush and dismantling 3 phase 5Hp AC induction motor and rewinding with super enameled copper wire of suitable gauge including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete 1 Each Job
334 230 Supply and fixing CI pipe with spigot and socket ends, titan joints type, centrifugal cast class'LA; of size 150 mm laid in trenches ,earth work and joints shall be measeured and paid separately 65 RM
335 231 Takig down unserviceable moo block motor pump set of capacity 3 phase 5 HP disconnecting the all necessary electrical connections and dismantlng the pump side and replacing the worn out winding and connected items like bearings, bush and coupling and rubber coupling etc; and rewinding with super enameled copper wire of suitable guage including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete all as specified. 1 Each job
336 232 Supply and operate swimming pool cleaning leaf rake mess frame net skimmer complete all as specified and directed. 2 Nos
337 233 Removing old unserviceable sluice valve 150 mm dia and S & F new sluice valve 150 mm dia bore PN 1.6 with nuts, bolts washer new gaskets etc all as per IS specifications complete all as specified & directed. 2 Each
338 234 M&L for carrying out 'B' check for 250KVA DG set trolley mounted all as per manufacturers instructions.\nNote : Rate quote shall be deemed to be inclusive of spares and filters but excluding engine oil. 1 Each Job
339 235 Supply and filling Engine Oil 15W 40 for 500/250 KVA DG set complete all as specified and directed. 150 Ltrs
340 236 Supply and replacement of diesel filter of 500 KVA DG Set complete all as specified and directed 2 Nos
341 237 Supply and replacement of diesel filter of 250 KVA DG Set complete all as specified and directed 2 Nos
342 238 Supply and replacement of Oil filter of 500 KVA DG Set complete all as specified and directed 2 Nos
343 239 Supply and replacement of Oil filter of 250 KVA DG Set complete all as specified and directed 2 Nos
344 240 Supply and filling coolent for 500/250 KVA DG Set complete all as specified and directed 250 Ltrs
345 241 Overhauling of monoblock pump set by removing and dismantling of pump from connected suction/ delivery pipes and electric connections etc. and taking to workshop and replacing (labour element only) unserviceable spares such as gland packing set, gun metal bushes, bearing, water seal packing set, gun metal bushes , bearing, water seal packing etc. cleaning of impeller, greasing etc. reassembling and refixing in original position including packing, and necessary nut & bolt etc. including minor parts and reconnection, recommissioning and testing for smooth functioning of following capacity pumps:-\nLocation : MO(MB) Ghatkopar\n(Note:- Major spares such as gunmetal bushes, gland packing, bearing and water seal to be replaced will be measured & paid as supply only under respective items)\n
346 241.01 3.01 5HP Capacity 1 Each
347 241.02 3.02 7.5HP Capacity 1 Each
348 241.03 3.03 10 HP capacity 1 Each
349 242 Supply only following spares for monoblock pump set all as specified and directed
350 242.01 Gun metal bushes for 5HP capacity 1 Each
351 242.02 Gun metal bushes for 7.5HP capacity 1 Each
352 242.03 Gun metal bushes for 10 HP capacity 1 Each
353 242.04 Gland packing set for 5HP capacity 1 Each
354 242.05 Gland packing set for 7.5HP capacity 1 Each
355 242.06 Bearing for 5HP capacity 1 Each
356 242.07 Bearing for 7.5HP capacity 1 Each
357 243 Testing of water Supply and obtain the following the research and tested through NABL accredited Lab including submitting of test certificate to Engineer – in Charge complete all as specified. Details of tests to be carried out (i) Turbidity (NTU), (ii) PH, (iii) Total Hardness CaCO3 (mg/l), (iv) Sulphate (SO4) (mg/l), (v) Iron (Fe) (mg/l), (vi) Magnesium (Mg) (mg/l), (vii) E-coli or thermo tolerant coliform bacteria \n 11 Each
358 244 Repair/Routine maintenance including carrying out daily check of fire alarm/fire fighting system complete with electronic control panel consisting of 02 zones in P/267 and P/268 buildings (G+16 floors) ie 17 stories including attendance of alarm personnel to attend the fire alarm system faults, testing, checking including replacement of unserviceable components other than mentioned in schedule “A” The fire alarm system consisting the following:-\n(a)   Indicator \n(b)   Electronic hooter\n(c)   Manual call point\n(d)   Smoke detector\n(e)   Heat detector\n(f)    Electronic fire control panel\n(g)   Main/Zone cards\n(h)   Battery of Fire panel DC supply \n(J) All wiring and cable connections \n(k) Fire diesel pump\n(l) Fire pump \n(m) Booster pump\nNote : Contractor shall be arrange monthly demonstration of fire fighting system of his own cost. b)contractor shall be liable to give warrently all fire fighting system shall serviceable/working condition. if the system found unserviceable/ not working at any time the contractor liable to penality. 11 Per Month
359 245 Supplying, installing, testing and commissioning cast iron body, ISI marked,BUTTERFLY VALVE as per IS 13095, ISI Marked with necessary fittings as per specification. Details : The Butterfly valve shall suitable for waterworks and tested to minimum of 20 kg/cm2 pressure. The body shall of cast iron conforming to IS:210 in circular shape and of high strength to take the minimum water pressure of 10kg/cm2 . The disk shall be heavy duty cast iron with anticorrosive epoxy or nickel coating Make- Audco/Kirloskar/Honeywell Note : i) The valve seat shall be of high grade elastomer or nitrile rubber. The valve in closed position shall have complete contact between the seat and the disc thoughout the perimeter. the elastomer rubber shall have a long life & shall not give away on continuous water pressue. The shaft shall be on EN 8 grade carbon steel. ii) the valve shall be fitted between two flanges on upper side of pipe flanges. The valve edge rubber shall be projected outside such that they are wedged within the pipe flanges to prevent leakages.iii) The valves shall be suppied with manual gear operated openin/closing system by lever.
360 245.01 150mm dia 2 Each
361 245.02 100 mm dia 1 Each
362 245.03 80 mm dia 2 Each
363 245.04 65 mm dia 2 Each
364 246 Supply and fixing in repair of Y stainer with necessary fittings, flanges, nut bolts etc as per specification. The "Y" type strainer shall have cast iron body confirming to IS 210 FG 200 Perforaed sheet shall be of brass or strain less steel 304. The Screen open area shall be minimum Four times cross sectional area at inlet. The Strainer shall be suitable for MIN. flow of 300 LPM at 10kg/cm2 sq pressure. The flanges shall be to IS 1538. The nut bolt sand washers shall be galvanised confirming too IS 1367. The pressure loss shall not be more than 0.5 kg/cm2 sq. The Hydraulic Testing shall done at 21kg/cm sq for the duration of Two hours of the following sizes :-
365 246.01 150 mm dia 2 Each
366 246.02 100 mm dia 2 Each
367 247 Supply & fixing in repair presure gauge glycerine filled with 15mm inlet connection dial size 100 mm of pressure range 0.21Kg/cm sq. with 15mm isolation valve with G.I. nipple all as specified 2 Each
368 248 Supply and fixing in repair pressure switches with adjustable pressure range from 1 to 10 bar with 15mm isolation valve with GI Nipple all as specified. 2 Each
369 249 Supply and fixing in repair approved quartezoid bulb 15mm dia sprinkler pendent type , IS 15106 chrome plated crossette plate, with temperature rating 68 degree with universal deflector as approved by T.A.C complete with all necessary connections complete all as specified and directed. 6 Each
370 250 All as per item No 249 but with temperature rating 79 degree 6 Each
371 251 Supply and fixing Bronze Orifice with 12mm thick disc with tag on plate mentioning dia of orifice for sprinkler system to control the pressure including rubber gasket packing, bolts, nuts washers all complete as per specified and directed 2 Each
372 252 S&F ball valve with brass speindle of 25mm dia complete all as specified 2 Each
373 253 S&F ball valve with brass speindle of 50 mm dia complete all as specified 2 Each
374 254 Supply and Fix in repairs outside hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600nun X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside and concealed in wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directed 6 Each
375 255 Supply and Fix in repairs internal hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800 mm x 600mm x 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside fixed on wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directedall as specied and directed. 4 Each
376 256 Supply and Fix in repairs fire fighting RRL hose pipe of 63mm, ISI marked, IS 636(type A), 15m long fitted with male and female gun metal coupling ISI marked, IS 903 complete all as specied and directed. 5 Each
377 257 Supply and Fix in repairs gunmetal branch pipe with nozzle suitable for 63 mm dia RRL hose pipe, ISI marked, complete all as specied and directed. 11 Each
378 258 Supply and Fix in repairs fire hydrant landing valve GM single outlet hydrant morris pattern oblique type 63 mm size confirming to IS 5290 with PVC blank cap and MS or GI chain in an approved manner. 12 Each
379 259 Supply and Fix in repairs two way fire brigade inlet, ISI marked, IS 5290, with non return valve, of gun metal size 63mm dia and including all fixing accessories complete all as specified and directed. Location: NS-130 (Cauvery), NS-175 (Samagri Bhavan) 1 Each
380 260 Supply and Fix in repairs four way brigade inlet, ISI marked, IS 5290,with non return valve of gun metal size 63mm dia and including all fixing accesorries complete all as specified and directed. Location: Vikramaditya 1 Each
381 261 Repair and maintenance of 100 HP fire service main pump multi stage having 2280 LPM at 90 mtrs head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100HP diesel engine including servicing by replacing unserviceable items of gland packing, bearings and charging lubricants for smooth running including servicing of 100 hp diesel engine by replacing filters, lubricant oil including defective parts like coupling, oil air filters, servicing of radiator, replacement exhaust gasket, replacement of diesel supply and return pipes from tank to engine, battery leads and checking of chaging circuit complete including base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed . 1 Each Job
382 262 Repair and maintenance of 100HP fire service main pump multi stage having 2280 LPM at 90 mtrs head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100HP AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed . \n 1 Each Job
383 263 Repair and maintenance of 5.5 HP fire service jockey pump multi stage having 180 LPM at 90 mtrs head multi stage pump of horizontal split casing running at 2900 RPM coupled with 5.5 HP AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed. 2 Each Job
384 264 Repair and maintenance of fire service booster pump multi stage having 900 LPM at 36 mtrs head ,horizontal split casing running at 2900 RPM coupled with AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed. 2 Each Job
385 265 Material and labour for replacement of un serviceable timer of starter, range 9 to 30 sec adjustable type voltage 415 V all as specified and directed by Engr-in- Charge. 2 Each
386 266 Material and labour for repalcement of un serviceable single phase preventer , 415 V 50Hz including electric connection all as specified and directed by Engineer-in-Charge. Make Minilec. 2 Each
387 267 S&F in repair MPCB (motor protection circuit breaker), 3 Phase, 415 Volts, 50 Hz, contractor type - MO 50 suitable of 75 HP pumps complete all as specifed and directed Make- L&T/Schneider/Siemens 2 Each
388 268 S&F in repair soft starter Model No CSXi-030-41, 3 Phase 60 Amp with auxiliary 30 VDC for withstanding current 5000A RMS 575 V AC Maximum in panels with proper wiring complete all as specified and directed. Make L&T Model No CSXi-030-41 or ABB/Schneider 2 Each
389 269 Supply and fix in repair barrel type HRC Fuse 2 to 32 Amps complete all as specifed 12 Each
390 270 Supply and fix in repair barrel type HRC Fuse 40 to 63 Amps complete all as specifed 11 Each
391 271 Supply and fix in repair maintenance free SMF type lead acid battery duly charged 12 Volts, 24 Ah complete all as specifed. Make- Exide/Amron 4 Each
392 272 Supply and fix in repairs Foot valve cast iron body both ends flanged suitable for 150mm bore CI pipe connection all as specified and directed Make -Kirloskar/Kartar/SIR/AUDICO 1 Each Job
393 273 Supply and fix in repair analogue addressable multisensor detector (Photo + Thermal) with base with galvanised steel, back box and all mounting accessories complete as specifed and directed Make- GE Edwards Model : SIGA-PHS+SB or equivalent siemens/ system sensor/Safex 10 Each
394 274 Supply and fix in repair analogue addressable heat detector, with galvanised steel back box all mounting accessories complete as specifed and directed Make- GE Edwards Model : SIGA-PHS+SB or equivalent siemens/ system sensor/Safex 12 Each
395 275 Supply and fix in repair addressable Dual Action Manual Pull staions inside for providing MS box of suitable size for concealing the manual call point in the wall and with mounting accessories all as specified Make- GE Edwards Model : SIGA-270 or equivalent siemens/ system sensor/Safex 5 Each
396 276 Supply and fix in repair addressable Monitor Modules in a suitable gavanised steel junction box with mounting accessories all as specified Make- GE Edwards Model : SIGA-CT1 or equivalent siemens/ system sensor/Safex 4 Each
397 277 Supply and fix in repair addressable control Module for Hooter in a suitable gavanised steel junction box with mounting accessories all as specified Make- GE Edwards Model : SIGA-CR or equivalent siemens/ system sensor/Safex 10 Each
398 278 Supply and fix in repair Electronic Hooter include provide MS box suitable size for concealing the hooter in the wall mounting accessories all as specified Make- GE Edwards Model : R HD or equivalent siemens/ system sensor/Safex 9 Each