Public Works Department-PWD has published Construction Of Barak For 200 People In 36 Vahini Pac Mirzapur Building Work. Submission Date for this Tender is 28-10-2020. Barrack Tenders in MIRZAPUR Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: CONSTRUCTION OF 200 PERSON HOSTEL BLOCK AT 39 PAC COMPOUND | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Excavation in foundation in ordinary soil (loam clay or sand)including filling lift upto 1.5m (5 feets) & lead upto 30m (100 feets) & including filling ,watering & ramming of excavated earth in to the trenches or into the space b/w the building & the site of foundation trenches or into the plinth & removal & disposal of surplus earth as directed by the E/I uptp a distance of 30M(100 fts.) from the foundation trenches including all T & P phowarah and basked etc. complete For nomal soil | 749.48 | cum | |
2 | 2 | For hard Rocks | 1146.33 | cum | |
3 | 3 | Cement concrete with 4cm guage approved stone ballast ,approved coarse sand and cement in proportion of 8:4:1 including supply of all material labour and T & P etc required for proper completion of the work. | 151.09 | cum | |
4 | 4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8km from the site of work and including watering ,dressing etc rate to include cost of all materials, labour T&P etc. Required for proper completion of work . | 43 | cum | |
5 | 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shallbe as follows : (1)Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters /100 sqm (5)Treatment of soil along external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apron along external perimter 5 liters/100 sqm. | 318 | Sqm | |
6 | 6 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level | 560 | cum | |
7 | 7 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level(Lintal bands) 5.37.2 | 9.41 | cum | |
8 | 8 | 5.37.2+5.38 | 8.32 | cum | |
9 | 9 | 5.37.2+(2x5.38) | 6.35 | cum | |
10 | 10 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level(sunshades) FOR Ground to IVth Floor | 17.98 | cum | |
11 | 11 | Vth Floor to 8th Floor | 11.16 | cum | |
12 | 12 | 9th Floor to Terracet | 8.59 | cum | |
13 | 13 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level(Lighter beam) FOR Ground to IVth Floor | 108.26 | cum | |
14 | 14 | Vth Floor to 8th Floor | 84.2 | cum | |
15 | 15 | 9th Floor to Terracet | 79.15 | cum | |
16 | 16 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level(slab) FOR Ground to IVth Floor | 177.54 | cum | |
17 | 17 | Vth Floor to 8th Floor | 139.92 | cum | |
18 | 18 | 9th Floor to Terracet | 120.58 | cum | |
19 | 19 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level(Column) FOR Ground to IVth Floor | 110.85 | cum | |
20 | 20 | Vth Floor to 8th Floor | 85.48 | cum | |
21 | 21 | 9th Floor to Terracet | 83.29 | cum | |
22 | 22 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage and over lapping and hookes required for completion of the work TMT Fe 500 | 2926.19 | Qtl | |
23 | 23 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level\nwith approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately | 214.41 | cum | |
24 | 24 | VIth Floor to 8th Floor | 222.7 | cum | |
25 | 25 | 9th Floor to Terracet | 105.64 | cum | |
26 | 26 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. FOR Ground to IVth Floor | 103.83 | cum | |
27 | 27 | Vth Floor to 8th Floor | 120.35 | cum | |
28 | 28 | 9th Floor to Terracet | 59.21 | cum | |
29 | 29 | Supply & fixing of flush doors 35mm commercial quality conforming to IS 2202 part 1 (1983) including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges,Bolts,locks handles, springs,fitting with necessary screws to be supplied departmently | 478.7 | Sqm | |
30 | 30 | Mild steel or iron work of small sizes and sections such as holding down bolts,hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel , bolts, nuts and wastages etc their fixing required for completion of the work | 7090.74 | Kg | |
31 | 31 | Fabrication of grill / stair case railing. | 18245.1 | Kg | |
32 | 32 | Fabrication of Z - section steel windows. | 27315.8 | Kg | |
33 | 33 | Fixing of steel or Steel chaukhats in position. (a) Door chaukhats | 368 | No | |
34 | 34 | (b) Window chaukhats | 149 | No | |
35 | 35 | (c) Ventilator chaukhats | 139 | No | |
36 | 36 | 15mm thick plaster wit cement mortar in proportion of 1:4 cement & Coarse sand) | 205.12 | Sqm | |
37 | 37 | Making grooves 10 to 12 mm widex 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. | 5655.8 | Rm | |
38 | 38 | Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials,labour T & P etc for proper completion of the work. Excluding GST | 854.77 | Rmt | |
39 | 39 | Supply and fixing 6 mm (1/4")thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work.(Flooring) | 432.6 | Sqm | |
40 | 40 | Supply and fixing 6 mm (1/4")thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work.(Dado/skirting) | 2160.67 | Sqm | |
41 | 41 | P & L Vetrified floor tiles Kajaria KERRO brand or equivalent brand of approved quality in different size with water absorption less than 0.8% and conforming to IS 15622 of approved make in colours & shade laid on 20mm thick cement mortar 1:4(1 cement:4 coarse sand) including grouting the joints with white cement & matching pigments etc complete (size of tiles 600x600mm) | 1226.11 | Sqm | |
42 | 42 | P & L Vetrified floor tiles Kajaria KERRO brand or equivalent brand of approved quality in different size with water absorption less than 0.8% and conforming to IS 15622 of approved make in colours & shade laid on 20mm thick cement mortar 1:4(1 cement:4 coarse sand) including grouting the joints with white cement & matching pigments etc complete (size of tiles 600x600mm) | 142.18 | Sqm | |
43 | 43 | 2.5cm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work | 165.6 | Sqm | |
44 | 44 | Painting or varnishing new iron work in small areas with one coat of ready mixed priming paint and one coat of approved superior quality ready mix paint (2nd quality synthetic enamel paint of approved brand such as British paint ,Shalimar Asian or equivalent as approved by E/I ) or varnish including supply of all material labour T & P etc required for proper completion of the work Paint to be used should confirm the ISI No. 103-1950 | 960.41 | Sqm | |
45 | 45 | Painting or varnishing new wood work in small areas with one coat of ready mixed priming paint and one coat of approved superior quality ready mix paint (2nd quality synthetic enamel paint of approved brand such as British paint ,Shalimar Asian or equivalent as approved by E/I ) or varnish including supply of all material labour T & P etc required for proper completion of the work Paint to be used should confirm the ISI No. 103-1950 | 1196.75 | Sqm | |
46 | 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | 5053.39 | Sqm | |
47 | 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Two Coat) | 14725.7 | Sqm | |
48 | 48 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two or more coats on new work | 9672.32 | Sqm | |
49 | 49 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes | 396.82 | Sqm | |
50 | 50 | Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm | 337 | No | |
51 | 51 | P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm | 674 | No | |
52 | 52 | Providing & fixing stainless steel tower handles with screws and 150mm long.SI marked LKO material rate | 674 | No | |
53 | 53 | Supply of glass strips for flooring.35mm wide & 4 mm thick | 648 | Rm | |
54 | 54 | 25mm thick kota stone slab flooring over 20mm(average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar | 1215.29 | Sqm | |
55 | 55 | 25mm thick kota stone slab in riser of steps,skirting 1:3 and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar | 178.35 | Sqm | |
56 | 56 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 sqm | 140.91 | Sqm | |
57 | 57 | P&L Brick coba 120mm thick laid with M-150 class brick bats coba7.50cm thick gap of 15mm to each other,over 20mm thick base of cement mortar 1:4 cement & coarse sand mixed with water proofing compund spreading cement slurry mixed with aerelic cement concrete water proofing compund filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement & coarse sand mortar finished smooth & top mashed false square 30cm x30cm and side wall parapet shall be mono tythic plaster wall upto 30cm.higher and junction and corner shall be rounded by brick ballast cement & coarse sand masonary Coba with top finished plaster mixed with acetic water proofing compund @ 2% by weight & including S/O all material labour T&P etc complete for proper completion of work. | 326 | Sqm | |
58 | 58 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 890.52 | Sqm | |
59 | 59 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. | 432.6 | Sqm | |
60 | 60 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2\nof approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. | 236.53 | Sqm | |
61 | 61 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces | 105.9 | Sqm | |
62 | 62 | Providing & finishing of Alluminium frame for door/Window/ventilator as per the direction of Engineer in charge | 38.5 | Rm | |
63 | 63 | Supply and fixing of anodised /aluminium windows having 2 mm thick aluminium section excluding coating & an average coating of 20 micron fully glazed made of aluminium door tube size 83.5x 44.65 mm as vertical member & 1114.00 x 44.45 mm size tube in bottom and horizontal members door chaukhat should be of aluminium tublar vertical with two openable shutters. The rate will include cost of material fixtures, 5mm glass handles, locks, screw necessary beeding & excluding cost of floor spring if required for proper completion of work as per direction of Engineer I/C. (FOR DOORS, WINODW & VENTILATORS)with 5.0mm thick plain glass | 14.8 | Sqm | |
64 | 64 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. | 15.81 | Sqm | |
65 | 65 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. | 3690 | Sqm | |
66 | 66 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete With 12 mm mild steel U beading | 389.41 | Sqm | |
67 | 67 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including\nnecessary excavation, levelling & dressing & finishing the top smooth. | 54 | Sqm | |
68 | 68 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) | 77 | Kg | |
69 | 69 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). | 199.2 | Kg | |
70 | 70 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge.Pre-laminated particle board with decorative lamination on both sides | 126 | Sqm | |
71 | 71 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete | 114.37 | Sqm | |
72 | 72 | Lintels, beams, plinth beams, girders, bressumers and\ncantilevers | 3583.25 | Sqm | |
73 | 73 | Suspended floors, roofs, landings, balconies and access\nplatform | 2735.64 | Sqm | |
74 | 74 | Columns, Pillars, Piers, Abutments, Posts and Struts | 2474.88 | Sqm | |
75 | 75 | Stairs, (excluding landings) except spiral-staircases | 333.94 | Sqm | |
76 | 76 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase | 120 | Rm | |
77 | 77 | 2.5 cm thick damp proof course of cement concrete consisting of one part cement 1-1/2 parts approved coarse sand and 3 parts approved 13 mm (1-1/2") graded stone grit including water proofing materials as ordered by the engineer-in-charge in the proportion as specified by the manufacture. | 40.63 | Sqm | |
78 | 78 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. | 40.63 | Sqm | |
79 | 79 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | 171 | No | |
80 | 80 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | 171 | No | |
81 | 81 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 20 mm dia | 359.05 | Mtr | |
82 | 82 | Cast cement concrete as in door sills, chaukhat boundary post as similar precast unit with cement, approved coarse sand and 20 gauge approved stone ballast in the proportion of 1:2:4 (class 150) excluding supply of reinforcement and its bending with 24 B.W.G.G.I. binding wire and including necessary scentring and shuttering etc. and also including supply of all materials labour T&P etc required for proper completion of work. | 15.95 | Cum | |
83 | 83 | SANITARY FIXTURES & ACCESSORIES : I Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required (a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | 41 | No | |
84 | 84 | Same as above but for European type W.C. pan with white plastic seat and lid | 43 | No | |
85 | 85 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. | 44 | No | |
86 | 86 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | 44 | No | |
87 | 87 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm | 2 | No | |
88 | 88 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. a) 32mm dia | 44 | No | |
89 | 89 | b) 40mm dia | 2 | No | |
90 | 90 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required a) Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | 40 | No | |
91 | 91 | b) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern | 4 | No | |
92 | 92 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade | 36 | Sqm | |
93 | 93 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge.15mm nominal bore | 43 | No | |
94 | 94 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet a) 100 mm diameter | 40 | No | |
95 | 95 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge.a) 15mm dia nominal dia. | 40 | No | |
96 | 96 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. | 42 | No | |
97 | 97 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms | 44 | No | |
98 | 98 | Providing and fixing Toilet paper holder a) C.P. brass | 43 | No | |
99 | 99 | Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. | 40 | No | |
100 | 100 | Supplying & Fixing of CP soap tray fixed to the wall with PVC rubber plug with CP brass screws- Make-ESSCO AEC-1131 | 40 | No | |
101 | 101 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter | 500 | Rm | |
102 | 102 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a) 110 mm | 7 | No | |
103 | 103 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a)110mm | 210 | No | |
104 | 104 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. | 7 | No | |
105 | 105 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100/75 mm diameter | 980 | Mtr | |
106 | 106 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 75 mm O.D. | 750 | Rm | |
107 | 107 | 110 mm O.D. | 980 | Rm | |
108 | 108 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. | 180 | No. | |
109 | 109 | Supply and fixing of UPVC S.W.R. Door bend confirming to IS-14735. Size 75 mm | 6 | No | |
110 | 110 | b) Size 110 mm | 144 | No | |
111 | 111 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 75 mm | 45 | No | |
112 | 112 | b) Size 110 mm | 84 | No | |
113 | 113 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm | 14 | No | |
114 | 114 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 75x75x75 mm | 25 | No | |
115 | 115 | b) Size 110x110x110 mm | 45 | No | |
116 | 116 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 75 mm | 35 | No | |
117 | 117 | Size 110 mm | 25 | No | |
118 | 118 | Providing and fixing PVC pipe confirming to IS make working pressure 6 kg/cm2 including testing labour T&P and all complete fittings. 140 mm diameter | 200 | Rm | |
119 | 119 | WATER SUPPLY PIPES AND FITTINGS - III Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall a) 20mm dia nominal outer dia pipes | 200 | Rm | |
120 | 120 | b) 25mm dia nominal outer dia pipes | 250 | Rm | |
121 | 121 | c) 32mm dia nominal outer dia pipes | 275 | Rm | |
122 | 122 | d) 40mm dia nominal outer dia pipes | 225 | Rm | |
123 | 123 | e) 50mm dia nominal outer dia pipes | 175 | Rm | |
124 | 124 | f) 62.5 mm dia nominal inner dia pipes | 185 | Rm | |
125 | 125 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. a) 15mm dia nominal outer dia pipes | 375 | Mtr | |
126 | 126 | b) 20mm dia nominal outer dia pipes | 550 | Mtr | |
127 | 127 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore | 84 | No | |
128 | 128 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.a) 15mm nominal bore | 3 | No | |
129 | 129 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore | 252 | No | |
130 | 130 | Providing & fixing C.P. Brass extension nipple(size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. | 125 | No | |
131 | 131 | Providing and fixing gun metal gate valve with wheel of approved quality. A) 40mm dia nominal bore | 28 | No | |
132 | 132 | b) 50mm dia nominal bore | 4 | No | |
133 | 133 | c) 65mm dia nominal bore | 6 | No | |
134 | 134 | Providing and fixing brass stop cock of approved quality.20 mm nominal bore | 86 | No | |
135 | 135 | SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM - IV Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. | 345 | Mtr | |
136 | 136 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. A) 100mm diameter | 50 | Mtr | |
137 | 137 | b) 150mm diameter | 100 | Mtr | |
138 | 138 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. A) 100mm diameter S.W. Pipe | 50 | Mtr | |
139 | 139 | b) 150mm diameter S.W. Pipe | 100 | Mtr | |
140 | 140 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. A) 150mm diameter | 165 | Mtr | |
141 | 141 | b) 250mm diameter | 230 | Mtr | |
142 | 142 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design a) 150 mm. dia. RCC Pipes | 165 | Mtr | |
143 | 143 | b) 250 mm. dia. RCC Pipes | 230 | Mtr | |
144 | 144 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885 | 6 | No | |
145 | 145 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75With FPS bricks of class designation 75 (i) For Sewer Line (i) For Sewer Line | 10 | No | |
146 | 146 | (ii) Extra for depth of man hole size 90x80 cm | 2 | Mtr | |
147 | 147 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar | 50 | No | |
148 | 148 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. | 2 | No | |
149 | 149 | Extra for depth of man hole size 90x120 cm | 0.5 | Mtr | |
150 | 150 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. | 8 | No | |
151 | 151 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250mm diameter | 1 | No | |
152 | 152 | EXTERNAL WATER SUPPLY SYSTEM -II Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia. | 120 | Mtr | |
153 | 153 | Provding and fixing gun metal non return valve of approved quality (screwed end) 65 mm nominal bore a) Horizontal | 1 | No | |
154 | 154 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) a) 65mm nominal bore. | 65 | Mtr | |
155 | 155 | b) 50mm nominal bore. | 75 | Mtr | |
156 | 156 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. A) 65mm diameter pipe | 45 | Mtr | |
157 | 157 | b) 50 mm diameter pipe | 75 | Mtr | |
158 | 158 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, with C.I. surface box 100x100x75mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks | 4 | No | |
159 | 159 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm dia nominal bore | 4 | No | |
160 | 160 | 1st Class brick (M-150) work in 4:1 coarse sand & cement of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work. | 139.3 | cum | |
161 | 161 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20 | 9.23 | cum | |
162 | 162 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter | 2 | No | |
163 | 163 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. | 25 | Mtr | |
164 | 164 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia | 25 | Mtr | |
165 | 165 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 2.77 | cum | |
166 | 166 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 3.01 | cum | |
167 | 167 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 3.27 | cum | |
168 | 168 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. | 1 | cum | |
169 | 169 | Cement concrete with 2 cm guage approved stone ballast ,approved coarse sand and cement in proportion of 4:2:1 including supply of all material labour and T & P etc required for proper completion of the work. | 1 | cum | |
170 | 170 | 12mm thick plaster with cement mortar in proportion of 1:3 cement and sand of 1.25 FM over brick work minimum thickness not be less than 10mm including supply of all material labour & T& P etc required for proper completion of the work. (1)1 cement : 3 coarse sand | 762 | Sqm | |
171 | 171 | First class bricks work in 1:6 in cement and fine sand of 1.25 F.M. mortar in foundation and plinth including supply of all materials, labor and T&P etc. required for completion of the work. | 4.09 | cum | |
172 | 172 | Man hole cover 455*610mm with frame light duty | 10 | No | |
173 | 173 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 2 | No | |
174 | 174 | WIRING POINTS Wiring point for light with 1.5 sq. mm. PVC insulated single core Copper conductor cable in heavy guage PVC conduit pipe with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit, partly laid in slab and partly concealed in the wall, complete GP Box , piano type switch & ceiling rose/angle/batten holder on 3 mm. thick phenolic laminated backelite sheet etc., complete in all respects, as directed including matching colour wash. ( PS No 138 C ) | 836 | No's | |
175 | 175 | Same as in item 139(B)but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. For 2 way light Point ( PS No 139 C ) | 26 | No's | |
176 | 176 | Same as in item 140 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. for ceiling fan/fresh air fan complete ( PS No 140 C ) | 222 | No's | |
177 | 177 | Same as in item 141 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. for 5 amp plug point including socket etc complete ( PS No 141 C ) | 331 | No's | |
178 | 178 | Same as in item 143 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit.for H.P.M.V./ Sodium Vapour lamp Point ( PS No 143 C ) | 8 | No's | |
179 | 179 | Same as in item 144 (B)but in PVC conduit with 1.5 sq. mm. F.R. insulated multistrand copper conductor cable as earthwire drawn inside the conduit. for Exhaust fan complete ( PS No 144 C ) | 50 | No's | |
180 | 180 | SUBMAIN Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm diaheavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect., including matching colour wash. ( PS No 1307 C ) | 1020 | Mtr's | |
181 | 181 | S/wiring of sub main with 2 no 4 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 20 mm dia heavy duty PVC conduit partly laid in slab and partly concealed in wall withone no 2.5 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth complete in all respect ( PS No 221 C ) | 1805 | Mtr's | |
182 | 182 | S/wiring of sub main with 2 no 6 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 25 mm dia heavy duty PVC conduit partly laid in slab and partly concealed in wall withone no 4.0 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth complete in all respect ( PS No 222 C ) | 415 | Mtr's | |
183 | 183 | S/wiring of sub main with 2 no 10 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 25 mm dia heavy duty PVC conduit concealded in wall withone no 6.0 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth complete in all respect ( PS No 223 C ) | 815 | Mtr's | |
184 | 184 | Supply and wiring of 4 number 10 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm diain heavy duty (2 mm thick) PVC conduit with 2 nos 6 sq.mm. FRLSH PVC insulated copper conductor cable as earth continuity wire drawn in conduit. partly concealed in wall and partly laid in slab alongwith reinforcement before concreting,, complete in all respect. ( PS No 278 C ) | 215 | Mtr's | |
185 | 185 | FITTINGS\nS/F of LED tube light with batten suitable for up to 1x22 watt. LED tube light complete includng tube etc on surface complete in all respect CAT-AAA PS No. 1413(A) | 374 | No's | |
186 | 186 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection, 8250-9900 system lumens High Power LED with lenses, >110lm/W, THD<10% at full lead, CDI>70, Potted driver complete in all respect., PS 1423 CAT-A | 8 | No's | |
187 | 187 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-B, PS No. 1406 | 27 | No's | |
188 | 188 | S/F Sheet steel enclosure flush mounting fitting with 20 amp-2 pin and earth metal clad scraping earth plug and socket for A C CAT B, PS No. 1031 | 12 | No's | |
189 | 189 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc.required for proper completion of work., PS No. 1139(A) | 141 | No's | |
190 | 190 | S/F LED Bulb 15 Watt (AR) | 261 | No's | |
191 | 191 | S/o Water tight Oblong 10watt LED Bulk head complete in all respect CAT-AA PS No. 1417 | 14 | No's | |
192 | 192 | CABLES S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clampetc of following size \nA- 10 sq.mm x 2 core cable ( PS No 501 B ) | 312 | Mtr | |
193 | 193 | B- 25 sq.mm x 3½ core cable ( PS No 501 J ) | 250 | Mtr | |
194 | 194 | C- 70 sq.mm x 3½ core cable ( PS No 501 J ) | 150 | Mtr | |
195 | 195 | E- 400 sq.mm x 3½ core cable ( PS No 501 T ) | 300 | Mtr | |
196 | 196 | S/F Brass nikil plated comression glands as under\nA- 10 sq.mm x 2 core cable ( PS No 503 B ) | 6 | No's | |
197 | 197 | B- 25 sq.mm x 3½ core cable ( PS No 503 J ) | 2 | No's | |
198 | 198 | C- 70 sq.mm x 3½ core cable ( PS No 503 M ) | 10 | No's | |
199 | 199 | D- 400 sq.mm x 3½ core cable ( PS No 503 T ) | 3 | No's | |
200 | 200 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nA- 6 sq.mm ( PS No 504 B ) | 24 | No's | |
201 | 201 | B- 10 sq.mm ( PS No 504 C ) | 80 | No's | |
202 | 202 | C- 25 sq.mm ( PS No 504 E ) | 10 | No's | |
203 | 203 | D- 35 sq.mm ( PS No 504 F ) | 20 | No's | |
204 | 204 | E- 70 sq.mm ( PS No 504 H ) | 60 | No's | |
205 | 205 | G- 185 sq.mm ( PS No 504 L ) | 6 | No's | |
206 | 206 | J- 400 sq.mm ( PS No 504 O ) | 18 | No's | |
207 | 207 | EARTHING\nSupply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. ( Earthing at Main Pannel Body) PS No. 703 | 2 | No's | |
208 | 208 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No 716 | 120 | Mtr | |
209 | 209 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. complete in all respect. ( Earthing at Main Pannel Neutral) PS No. 725(B) | 2 | No's | |
210 | 210 | S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT B PSNo. 1026(C) | 25 | No's | |
211 | 211 | S/F Surface/Flush mounting 8 way SPN Distribution board witout MCB with additional metel door complete in all respect CAT A PS No. 1024(A) | 52 | No's | |
212 | 212 | S&F of 40 Amp. DP MCB (10 KA) C Curve Cat B, PS No. 1010 | 52 | No's | |
213 | 213 | S&F of 40 Amp. 4 pole MCB (10 KA) CAT B, PS No. 1020 | 12 | No's | |
214 | 214 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve CAT B, PS No. 1020(A) | 12 | No's | |
215 | 215 | S/F 6 Amp to 32 Amp SPMCB (10 KA) CAT B, PS No. 1002 | 620 | No's | |
216 | 216 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work., PS No. 1149 | 222 | No's | |
217 | 217 | Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. CAT-AA PS No. 1443 | 2 | No's | |
218 | 218 | MISCELLANEOUS\nS/F of Rubber matting1800x900x12 mm tested and chequred PS No.1136 | 2 | Nos | |
219 | 219 | S/F of shock Treatmemt Chart (prescribed under IE rules) PS No. 1134 | 2 | Nos | |
220 | 220 | Erection and testing of ceiling fan and regulator etc Excluding S/o parts PS No. 1115 | 222 | Nos | |
221 | 221 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. PS No. 1120 | 50 | Nos | |
222 | 222 | Supply and fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. PS No. 1122 | 50 | Nos | |
223 | 223 | S/F of Electronic Modular fan regulator 120-280 Volts ISI Marked PS No. 1203(C) | 222 | Nos | |
224 | 224 | S/F Loose wire Box near by TPN DB 200x250x65mm size PS No. 162 | 30 | Nos | |
225 | 225 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. \nIncoming:\n1000Amp/415 Volt ACB-1 No\nOutgoing:\n630Amp/415 Volt MCCB-1 No & 400Amp, MCCB-1 No\n100Amp/415 Volt MCCB-1 No, 63Amp MCCB-1 No, 32Amp MCCB-1 No (AR) | 1 | No. | |
226 | 226 | RISING MAIN\nSupply and erection of 630 Amp. TPN Rising Mains complete with top end cover plate etc. On angle iron wall brackets complete in all respect. PS No. 922 | 20 | Mtr. | |
227 | 227 | Supply and erection of 400 Amp. TPN Rising Mains complete with top end cover plate etc. On angle iron wall brackets complete in all respect.PS No.921 | 60 | Mtr. | |
228 | 228 | Supply and erection of 63 Amp. TPN tap off box on rising mains complete with HRC fuses etc. complete in all respect. PS No.913 | 25 | Nos. | |
229 | 229 | Supply and erection of incoming adopter box for mounting 400 Amp. TPN CFS unit including connectors of required capacity on to the rising Mains complete in all respect.PS No. 916(A) | 1 | No | |
230 | 230 | Supply and erection of incoming adaptor box for mounting 630 Amp. TPN CFS unit including connectors of required capacity on to the rising mains complete in all respect.PS No. 917(A) | 1 | Nos. | |
231 | 231 | Supply and Fixing of pluging point 400 Amp to 1000 Amp TPN Sandwich alumininum bus bar trunking complete in all respect. PS No. 927 | 25 | Nos | |
232 | 232 | S/F of Ceiling Fan 1200mm PS No. 1501 (ii) | 222 | Nos | |
233 | 233 | S/F of Exhaust Fan 300mm (GEM) | 50 | Nos | |
234 | 234 | LIGHTING CONDUCTOR . Supply and fixing of vertical air termination final rod comprising of 300mm long x 25mm dia. Copper rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respect. ( PS No 712 A ) | 2 | No's | |
235 | 235 | Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineer-in-charge. ( PS No 710 ) | 220 | Mtr's | |
236 | 236 | Supply and fixing of vertical down conductor of 32mm x 6mm G.I. strip etc. on approved clamps on surface for lightning conductor complete in all respects for five and above storeyed building ( PS No 713 C ) | 160 | No's | |
237 | 237 | Supply and burying earth for lighting conductor of 900mm x 900mm x 3mm copper plate vertically with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. ( PS No 709 ) | 4 | Mtr's | |
238 | 238 | FIRE ALARM SYSTEM\nSupply, Installation Testing & Commissioning of Calling / Hooter complete the work in all respect. Make:- Agni, Agni Suraksha/ Equvalent | 12 | No's | |
239 | 239 | Supply, Installation & Commissioning of Manual Call Point complete the work in all respect. Make:- Agni, Agni Suraksha/ Equvalent | 12 | No's | |
240 | 240 | Supply, Installation & Commissioning of Fire Alarm 10 Zone complete the work in all respect. Make:- Agni, Agni Suraksha/ Equvalent | 1 | No's | |
241 | 241 | Supply, Installation & Commissioning of 6 Zone Fire Alarm Local Control Pannel complete in all respect. Make:- Agni, Agni Suraksha/ Equvalent | 3 | No's | |
242 | 242 | S.I.T.C. of Submain with 3 No 1.5sqmm PVC insulated signle core copper conductor wire in 20 mm dia heavy grade Rigid Steel conduit on surface complete | 1285 | Mtr | |
243 | 243 | Supply, installation, testing and commissioning of intellegent addressable Fixed Temprature thermistor type Heat Detector comes with standard mounting base, Dual LED for 360 view, rotary address switch to programme the detectors. Detectors shall be sealed against dirt, insects, and back pressure. The Detector & base both should be UL Listed & FM Approved.\nMakes: Notifier (USA)/ Simplex/Mircom/Honeywell XLS 3000/System Sensor. as per direction of engineer Incharge complete in all respect. | 24 | No's | |
244 | 244 | S.I.T.C. of Phoatoelectric type smoke detector.\nMake-System Sensor, Apollo Agni | 24 | Mtr | |
245 | 245 | FIRE HYDRANT SYSTEM\nSITC of M.S Black Pipe "C" Class (IS:1239/3589 Including Cutting, welding etc. & providing suitable flanges alongwith necessary fittings viz. bends, tees, reducers etc. & anti-corrosive treatment\n200 mm dia. | 12 | Mtr | |
246 | 246 | 150 mm dia. | 280 | Mtr | |
247 | 247 | 100 mm dia. | 55 | Mtr | |
248 | 248 | 80 mm dia. | 30 | Mtr | |
249 | 249 | SITC of Single headed Hydrant comprising of 80 mm dia. Flanged bend 63 mm dia. SS oblique pattern landing valve complete with blank and Cap . | 25 | Nos | |
250 | 250 | SITC of First aid Hose reel drum with 20 mm dia, 30 m long rubber pipe shut off nozzle, 25 mm dia., gate valve complete conforming to IS: 884/444. | 14 | Nos | |
251 | 251 | SITC of RRL Hose 63 mm dia x 15 m long complete with GM/SS coupling conforming to IS: 636. | 24 | Nos | |
252 | 252 | SITC of SS Branch Pipe & Nozzle IS: 903. | 25 | Nos | |
253 | 253 | S.I.T.C. of Hose Box of 18 SWG MS Sheet with glass fronted door including locking arrangment to accomondate 2 No RRL Hose & 1 No SS Branch pipe with nozzle (External) | 13 | Nos | |
254 | 254 | SITC of Hose Box of 18 SWG M.S Sheet with glass fronted door to accommodate 2 nos. RRL Hose & 1 nos. SS Branch Pipe with nozzel. (Internal) | 12 | Nos | |
255 | 255 | SITC of C.I double flanged Butterfly Valve complete with nuts, bolts & washers etc. conforming IS 780\n80 mm dia. | 25 | Nos | |
256 | 256 | SITC of cast iron double flanged Non Return Valve complete with nuts, bolts and washers conforming to IS 5312.\n150 mm dia. | 6 | Nos | |
257 | 257 | 100 mm dia. | 2 | Nos | |
258 | 258 | SITC of Air Cushion Tank assembly 200 mm dia. 1.5m long with Air Release Valve pressure gauge & accessories. | 2 | Nos | |
259 | 259 | SITC of Electrical Driven Terrace pump of 450 LPM with minium pressure of 2.0 kg/cm2 complete installation with concreate foundation and suitable base plate by iron channel complete work as per requirment (Make:- Kirloskar/other standard make.)` | 1 | No. | |
260 | 260 | SITC of Automatic Starter Panel Suitable forTerrace Pump 10 HP. Complete in all respects. | 1 | No. | |
261 | 261 | SITC of GM Fire brigade 4 way Inlet connection. Complete in all respect. | 3 | No. | |
262 | 262 | SITC of Main Pump Electrical Operator TEFC type induction motor of 60 HP including suitable Pump 70 Mtr. Head with 2280 LPM. Complete installation with concrete foundation and suitable base plate by Iron Channel complete work as per required (Make:- Kirloskar/other standard make.)` | 1 | No. | |
263 | 263 | SITC of Diesel Engine Pump 2280 LPM, 70 Mtr. Head 1500/1800 RPM, 63 BHP, Horizontal Fire Pump with Water Cooled Diesel Engine with flexible coupling, Common Bed Plate etc. for mounting the Diesel Engine and Pump. Complete in all respects. | 1 | No. | |
264 | 264 | SITC of Electrical Driven TEFC type induction motor of 15 HP, including suitable pump 70 m. Head with 180 LPM. Complete installation with concrete foundation and suitable base plate by iron channel complete work as per required Jockey Pump | 1 | No. | |
265 | 265 | SITC of Main Control Panel for Main Electric Motor, 1 No. Diesel Engine & One nos. Jockey Pump reqired HP. With starter switch, selectors, Volt Meter, Ampere meter and Battery Charger, Factory fabricated & wired metal clad dust & vermin proof floor mounting HRC type 315A/415 V Main switch. Engine Control relay, required HP D.O.L. Starter with timer single phase Preventor LED type indication lamp etc. | 1 | No. | |
266 | 266 | Supply Installation Testing and Commissioning of (i) One pump house with under ground watter tank having size 3.0 mtr.x4.0mtr.x 3.o mtr approx \nUnderground RCC water tank having 1.0 Lacs ltr. Capacity approx.\nTubewell complete in all respect with boring 5 HP Submarsible pump control pannel including fitting testing etc. | 1 | job | |
267 | 267 | SITC of Pressure Switch. Complete in all respect. | 4 | Nos | |
268 | 268 | SITC of Pressure Gauge. Complete in all respect. | 20 | Nos | |
269 | 269 | SITC of Automatic priming Arrangement for all fire pump including necessary pipe, fitting, water level controller, 1 HP pump etc. complete in all respect. | 1 | Job | |
270 | 270 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch\nboard (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all\nrespect. PS No 703 | 3 | No. | |
271 | 271 | Supply and laying of 32mm X 6 mm G.I. strip from earth electrode directly in the ground as required. Complete in all respect. | 75 | Mtr. | |
272 | 272 | S/L of 2x1.5 Sqmm Armored Cable. Compete in all respect. | 250 | Mtr. | |
273 | 273 | S/L of Aluminium conductor PVC Insulated sheated cable 100 volt grade as per PWD Specification\n16 Sqmm 4 Core | 100 | No's | |
274 | 274 | 150 Sqmm 3½ Core | 150 | No's | |
275 | 275 | S/F of Beass Nicle plated Lugs\n16 Sqmm | 8 | No's | |
276 | 276 | 70 Sqmm | 4 | Nos | |
277 | 277 | 150 Sqmm | 12 | Nos | |
278 | 278 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PS No 1131 | 28 | No. | |
279 | 279 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PS No 1132 | 12 | Cum | |
280 | 280 | SITC of Submersable pump 7.5 HP, 3 Phase Including Power lead and Starting Pannel etc Standerd Make | 2 | Nos. | |
281 | 281 | DG SET\nSupply of 125 KVA AC 3 Phase 415 V Water Cooled silent DG set complete with 125 kva/ 100 kw Brushless Alternator on MS base with fuel tank, 12 Volt Battery, Manual control panel with CPCB approved silent canopy with trial Make Kriloskar/ Eisher/ Cummins/ or Equvalent (GST Inclusive) | 1 | No | |
282 | 282 | Fabrication of platform (3.75x1.50x.75 mtr) by R.CC concrete for 125 KVA DG set (Civil Sch. Item No. 287A) | 4.22 | Cum | |
283 | 283 | Labour Charges of D.G. Set installation and commissioning Including Unloading, Placing on Foundation and Lubs and Diesel etc | 1 | No | |
284 | 284 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. P S No 725 (B) | 2 | Nos | |
285 | 285 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. P S No 716 | 60 | Mtr | |
286 | 286 | CABLES . S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clampetc of following size \n240 sq.mm x 3½ core cable PS No 501(R) | 34 | Mtr | |
287 | 287 | S/F Brass nikil plated comression glands as under\n240 sq.mm x 3½ core cable PS No 503 R | 4 | No's | |
288 | 288 | S/F of plain or pin type copper tin plated cable socket (Lugs)\n120 sq.mm PS No 504(J) | 4 | No's | |
289 | 289 | 240 sq.mm PS No 504(M) | 12 | No's | |
290 | 290 | LIFT\nSupply & Errection of Gen-2, 1020 Kg 15 persons, 12-stops (G+11) lift speed 1 MPS with stainless steel hairline finish travel 41m (Approx), ACD3-MR, Drive-VF Regenerative (Closed Loop), Power Supply-400/415 Volts (3 Phase AC), Operation-Full Collective Operation, Car Group-One Car (Simplex), Machine-PM Gearless, Traction Media-Flat Coated Steel Belt, Pit Depth-1350, Over Head-4200, Hositway Diimensions-1750 mm W x 2750 mmD, Car Dimensions (WxDxH-mm) 1000 mm W x 2400mm D x 2200mmD, Door Opening-900mm W x 2000mmH, Door Operator- DC Door Operator, COP- COP for Stops < = 12 (950mm) in Stainless Steel # 4 (Hair Line), Options Included-Automatic Rescue Operation. Make Otis/ Sindlar/Mistubishi/ or Equvalent | 1 | No | |
291 | 291 | Supply & Errection of Gen-2, 544 Kg 8 persons, 12-stops (G, 1-12) lift speed 1 MPS with stainless steel hairline finish travel 41m (Approx), ACD3-MR, Drive-VF Regenerative (Closed Loop), Power Supply-400/415 Volts (3 Phase AC), Operation-Full Collective Operation, Car Group-One Car (Simplex), Machine-PM Gearless, Traction Media-Flat Coated Steel Belt, Pit Depth-1350, Over Head-4200, Hositway Diimensions-1750 mm W x 2750 mmD, Car Dimensions (WxDxH-mm) 1000 mm W x 2400mm D x 2200mmD, Door Opening-900mm W x 2000mmH, Door Operator- DC Door Operator, COP- COP for Stops < = 12 (950mm) in Stainless Steel # 4 (Hair Line), Options Included-Automatic Rescue Operation Make Otis/ Sindlar/Mistubishi/ or Equvalent | 1 | No | |
292 | 292 | WIRING OF LIFT\nWiring point for light in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. pipe concealed in the wall, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect, PS No. 131(C) | 34 | Nos | |
293 | 293 | Wiring point for fan / fresh air fan (light duty exhaust fan) in PVC conduit with 1.5 sq. mm.PVC insulated aluminium conductor cable as earthwire\ndrawn inside the conduit. complete with 8 SWG GI earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc complete in all respect, PS No. 133(C) | 2 | Nos | |
294 | 294 | Wiring point for plug with in PVC conduit with 1.5 sq. mm.PVC insulated aluminium conductor cable as earthwire drawn inside the conduit. complete with 8 SWG GI earth continuity wire, piano type switch and socket etc. complete in all respect including matching colour wash. PS No.134(C) | 4 | Nos | |
295 | 295 | W/p for Ex-Fan with 1.5sqmm PS No. 137(C) | 2 | Nos | |
296 | 296 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. Ps No. 1417 CAT-AAA | 28 | Nos | |
297 | 297 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. PS No. 1413 CAT-AAA | 4 | Nos | |
298 | 298 | Supply and fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. PS No. 1203(A) | 2 | Nos | |
299 | 299 | Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. PS No. 705 | 4 | Nos | |
300 | 300 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No.717 | 300 | Mtr | |
301 | 301 | S & F surface/Flush mounting 4ways V TPN distribution board with additional Door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. PS No.1030(A) CAT-A | 2 | Nos | |
302 | 302 | S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. PS No.379 | 1 | Nos | |
303 | 303 | S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. PS No. 1024(A) CAT-A | 2 | Nos | |
304 | 304 | S&F of 63 Amp. DP MCB (10 KA) PS No. 1011 CAT-A | 2 | Nos | |
305 | 305 | S&F of 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release PS No. 1021 CAT-A | 2 | Nos | |
306 | 306 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve PS No. 1002 CAT-A | 12 | Nos | |
307 | 307 | Erection and testing of ceiling fan and regulator etc. excluding supply of down rod, complete in all respect. PS No. 1115 | 2 | Nos | |
308 | 308 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. PS No. 1120 | 2 | Nos | |
309 | 309 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick complete in all respect\n120 sqmm x 3½ Core PS No. 501(o) | 60 | Mtr | |
310 | 310 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect.\n120 sqmm x 3½ Core PS No. 503(o) | 8 | Nos | |
311 | 311 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect\n95sqmm PS No. 504(i) | 8 | Nos | |
312 | 312 | Same as above 120sqmm PS No. 504(j) | 12 | Nos | |
313 | 313 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis complete in all respect\nIncming 200A MCCB- 1 No\nOutgoing 100A MCCB- 2 Nos PS No. 812(a)(ii) | 2 | Nos | |
314 | 314 | Supply and fixing of C02 type fire extinguisher 6.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PS No. 1132(A) | 4 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy