}

Purchase Of Diff.Types Types Of Ctvs Surgical Consumable Items For Ctvs Department On 2 Year Rate Contract Basis Part I, CNC AIIMS, NEW DELHI-Delhi

All India Institute Of Medical Sciences has published Purchase Of Diff.Types Types Of Ctvs Surgical Consumable Items For Ctvs Department On 2 Year Rate Contract Basis Part I. Submission Date for this Tender is 14-12-2020. Surgical Disposable Tenders in CNC AIIMS, NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

25791380
Corrigendum : Purchase Of Diff.Types Types Of Ctvs Surgical Consumable Items For Ctvs Department On 2 Year Rate Contract Basis Part I
Tender
Indian
Delhi
Cnc Aiims, New Delhi
14-12-2020

Tender Details

Purchase Of Diff.Types Types Of Ctvs Surgical Consumable Items For Ctvs Department On 2 Year Rate Contract Basis Part I - 2 Iabp Catheter ( 7.5 Fr ) N• Catheter Size Should Be 7.5 French With Balloon Volume Displacement Range 30 Cc -40 Cc. N• Should Enable Fast Gas-Shuttle Performance ( In Situations Of Tachyarrythmias ) N• Should Enable Smooth Insertion With Minimum Force. N• Catheter Should Be Insertable In Both Options – With Sheath / Sheath Less. N• Should Have Kink Resistant Wire Reinforced Body N• Should Give Sharp Calibrated Arterial Waveforms On The Monitor. N• Should Enable Consistent Prolonged Augmentation Without The Need For Frequent Line Flushing. N• Should Have High Fatigue Resistance. N• Should Inflate Immediately With Start-Up Of Machine. N• Balloon Membrane Should Have High Abrasion Resistance And Minimum Thrombogenicity. N• Compact Efficient Protective Packing For Balloon Membrane Protection. N• Balloon Catheter Kit Should Have All Requisite Accessories – 1 / 2 Guide Wires, Dilators, Sheath, Gas Tubing, Console Connector ( If Required ) . N• Catheter Should Be Connectable To All Standard Iabp Machine Consoles. N• Should Be Fda Approved 3 Iabp Catheter ( Small Adult ) ( 7.0 Fr ) N• Catheter Size Should Be 7.0 French With Balloon Volume Displacement Range 20-30 Cc. N• Should Enable Fast Gas-Shuttle Performance ( In Situations Of Tachyarrythmias ) N• Should Enable Smooth Insertion With Minimum Force. N• Catheter Should Be Insertable In Both Options – With Sheath / Sheathless. N• Should Have Kink Resistant Wire Reinforced Body N• Should Give Sharp Calibrated Arterial Waveforms On The Monitor. N• Should Enable Consistent Prolonged Augmentation Without The Need For Frequent Line Flushing. N• Should Have High Fatigue Resistance. N• Should Inflate Immediately With Start-Up Of Machine. N• Balloon Membrane Should Have High Abrasion Resistance And Minimum Thrombogenicity. N• Compact Efficient Protective Packing For Balloon Membrane Protection. N• Balloon Catheter Kit Should Have All Requisite Accessories – Puncture Angiographic Needles, 1 Or 2 Guide Wires, Dilators, Sheath, Gas Tubing, Console Adapter, Catheter Extender, Three-Way Stopcock. N• Catheter Should Be Connectable To All Standard Iabp Machine Consoles. N• Should Be Fda Approved. 4 1. Iabp Catheter ( Large Adult ) ( 8 Fr ) N• Catheter Size Should Be 8.0 French With Balloon Volume Displacement Range 40-50 Cc. N• Should Enable Fast Gas-Shuttle Performance ( In Situations Of Tachyarrythmias ) N• Should Enable Smooth Insertion With Minimum Force. N• Catheter Should Be Insertable In Both Options – With Sheath / Sheathless. N• Should Have Kink Resistant Wire Reinforced Body N• Should Give Sharp Calibrated Arterial Waveforms On The Monitor. N• Should Enable Consistent Prolonged Augmentation Without The Need For Frequent Line Flashings. N• Should Have High Fatigue Resistance. N• Should Inflate Immediately With Start-Up Of Machine. N• Balloon Membrane Should Have High Abrasion Resistance And Minimum Thrombogenicity. N• Compact Efficient Protective Packing For Balloon Membrane Protection. N• Balloon Catheter Kit Should Have All Requisite Accessories – 1 / 2 Guide Wires, Dilators, Sheath, Gas Tubing, Console Connector ( If Required ) . N• Catheter Should Be Connectable To All Standard Iabp Machine Consoles. N• Should Be Fda Approved. 5 Mist Blower N• Surgical Blower Humidifier Intended For Use During Cardiac And Other Fine Surgeries. N• Should Be Made Up Of Latex Free, Non-Toxic Medical Grade Material. N• Specially Designed For Improving The Visibility At Anastomotic Or Other Fine Surgical Sites. N• Should Create A Consistent And Predictable Blood Clearing Mist. N• Should Consist Of An Extra Soft Tip, Preceded By A Shaft And A Soft Textured, Ergonomic Handle Followed By A Flexible Connector Provided With A Dual Lumen Tubing That Entails Passage Of Normal Saline At Gentle Air Pressure. N• Should Have Specialized Nozzle Utilizing A Micro Orifice For Fluid Delivery And A Separate Orifice For Gas Delivery. N• Should Have The Malleable Shaft And On / Off Control On The Hand Piece. N• Sterile, Individually Packed In A Box. N N N 6 Ima Needle N• Should Be Made Of Medical Grade Stainless Steel N• Should Be Used For Flushing, Irrigation And Injection N• Tip Should Be 3Mm And 6.5Cm Long ( 2 .5” ) N• The Lumen Should Be Of 1 Mm Or Lessonly. N• The Tip Of Cannula Should Be Bulbous Andatraumatic. N• The Cannula Should End With Female Luer Fitting: Which Can Be Attached To Any Regular 5Ml Or 10Mlsyringe N• Prototype: Debakey Heparin Needle Smallcatalogue #: 351575 ( Https: / / Www.Teleflexsurgicalcatalog.Com / Pilling / Product / 351575-Debakey-Heparin-Needle-Small ) N 7 Vascular Access Sheath ( 4Fr-9Fr ) Kit N Radio-Opaque Polyurethane Sheath N7.5-11 Cm Long, Color Coded. None Haemostasis Valve And Attached Three-Way Stopcock. Nvessel Dilator With Snap Lock Feature Nguidewire N 8 Vascular Access Sheath ( 10 Fr-14 Fr ) Kit N• Radio-Opaque Polyurethane Sheath N7 Color Coded. N• One Haemostasis Valve And Attached Three-Way Stopcock. N• Vessel Dilator With Snap Lock Feature Nguidewire N 9 Micro Introducer Kit N• Tapered, Siliconized Micro-Introducer For Smooth Vessel Insertion ( 4 Fr, 5 Fr ) N• High Quality Guidewire N• Smooth Echogenic 7 Cm / 9 Cm Needle. N 10 Rapid Priming Set N• These Should Facilitate The Transfer Of Fluid During The Priming Of The Circuit. N• Should Have Large Bore Spikes Attached To Flexible Tubing With A Clamp. N• Should Terminate With Either An Open-End Tube Or A Male Luer. N 11 Disposable Bulldog Clamps ( All Sizes ) N• Disposable’ Bull Dog’ Clamps For Temporary Occlusion Of Vascular Structures. N• Atraumatic N• Made With Standard Quality Plastic. Ncolor Coded N 12 Aortic Punch ( 3Mm-5.5 Mm ) N• Blade Should Be Able To Float Around The Punch. N• Punch Should Be Available With Tapered Cutting Blade To Increase Visibility. N• Should Be Available In All Functional Sizes N 13 Coronary Artery Retraction Clips ( 3Mm, 5Mm ) . N• Should Be Designed To Improve Exposure To A Coronary Anastomosis Site. N• Should Be Able To Small Prongs And Gently Hold Tissues Away From The Vessel To Improve Vision. N 14 Epicardial Spring Retractor ( Fat Spreader ) ( Blunt Prongs ) N• 3 X 3 Blunt Prongs N• Size : 25Mm-38Mm N• Prototype: Http: / / Unimedic.Co.Jp / Product / Geister / Pdf / Epicardial.Pdf N 15 Epicardial Spring Retractor ( Fat Spreader ) ( Sharp Prongs ) N• 3 X 3 Sharp Prongs N• Size : 25Mm-38Mm N• Prototype: Http: / / Unimedic.Co.Jp / Product / Geister / Pdf / Epicardial.Pdf N 16 Emergency Cricothyroidotomy Set N• Should Have A Conical Introducer, N• Dilators Should Be Made Of Stainless Steel, N• Cricothyroidotomy Tubes Should Be Of Medical Grade Plastic. N• With 15 Mm Connector, Flexible Tube Extension Made Of Silicone, Scalpel, One Way Syringe, Comfort Neck Band Sizes 2Mm, 4Mm. N 17 Percutaneous Suture Closure Device N• Percutaneous Suture-Mediated Closure System N• Should Be Composed Of A Plunger, Handle, Guidewire, And Sheath. N• The Device Should Deliver A Single Suture ( Stitch ) To Close The Puncture Sites ( Access Sites ) In Large Vessels In The Leg ( Femoral Vein Or Artery ) Following Catheterization Procedures. N• It Should Be Possible To Close Puncture With 5-21Fr ( Max. 26F Od1 ) Arterial Sheaths And 5-24Fr ( Max. 29F Od1 ) Venous Sheaths.Prototype : Perclose. N 18 Tissue Stabilizer For Minimally Invasive Beating Heart Surgery N• Should Be Stabilizer To Be Used Via Thoracotomy With Detachable Shaft And Should Have Fully Rotating Pods N 19 Tissue Stabilizer For Beating Heart Surgery N• Should Be A Low-Profile Tissue Stabilizer With Auto Spread Feature Of Pods. N 20 Heart Positioner For Minimally Invasive Beating Heart Surgery N• Should Be A Positioner With Detachable Shaft For Mics Via Thoracotomy. N 21 Heart Positioner For Beating Heart Surgery N• Should Be A Low-Profile Positioner For Off Apex Position Use / To Lift The Heart N

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 23-11-2020 dateextensionafterprebid Date 14-12-2020

Key Value

Document Fees
Refer document
EMD
INR 50000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail