Establishment Of Sub-Divisional Lab In Tehsil Nagrota Bagwan Distt . Kangra Sh_Establishing Of Water Testing Lab And Conducting Various Quality Test Parameters, Nagrota Bagwan-Himachal Pradesh

Irrigation And Public Health Department has published Establishment Of Sub-Divisional Lab In Tehsil Nagrota Bagwan Distt . Kangra Sh_Establishing Of Water Testing Lab And Conducting Various Quality Test Parameters. Submission Date for this Tender is 27-10-2020. Building Work Tenders in Nagrota Bagwan Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25777580
Establishment Of Sub-Divisional Lab In Tehsil Nagrota Bagwan Distt . Kangra Sh_Establishing Of Water Testing Lab And Conducting Various Quality Test Parameters
Open Tender
Indian
Himachal Pradesh
Nagrota Bagwan
27-10-2020

Tender Details

Establishment Of Sub-Divisional Lab In Tehsil Nagrota Bagwan Distt . Kangra Sh_Establishing Of Water Testing Lab And Conducting Various Quality Test Parameters

Key Value

Document Fees
INR 250 /-
EMD
INR 16335.0 /-
Tender Value
INR 8.16 Lakhs /-

BOQ Items

1.Name of Work:- Establishment of Sub-Divisional Lab in Tehsil Nagrota Bagwan Distt.Kangra (H.P.)(Sub Head:- Establishing of Water testing Lab and conducting various quality test parameters)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Preprogrammed Analyser:- Source Lamp Light Emiting Dode (LED) Wavelength Range 420 NM, 520 NM, 560 NM, 610 NM Wavelength selection. Automatic Operating Mode Transmittance (%) Absorbance and concentration sample Cell Compatibility 1 inch round or 16 Min Round (with Adapter) Data Logger 500 Measured values (Result Date, Time Sample ID, User ID) enclosure rating IP 67 (Vail Cover closed) Battery requirements 4, Aa size Alkali Cells Battery Life 6 months (typical @ 5 reading a Day/5 Days/Weeks without back light ...... Backlight Usage will Decrease Battery Life Display Graphical Display 240 X 160 Pixel Backlight 220 allready built in the instrument should be of reputed make (Hach DR 1900) Pre-Programmed water quaility anylysis sepectometer Colorimeter Auto Steel Wave length type with minimum spectral band width 10 mm operating range 0-50 degree AC Battery operated for measuring the parameters like free chlorine Fluorides Calciam Magnesium Iron as Fe,NO3 as nitrate NO2 as Nitrite pH ans sub plate. Pre-programmed Single Handheld instrument provides access to of the most Common Parameters/essential Test Parameters complete in all respect as per the direction and to the entire satisfaction of Engineer-In-Charge within all leads and Lifts. 1 No
2 2 Bacteriological Incubator Make:- Merck/Hach/Qic/Leh/Waters/Memmert:-Standard double Walled Construction. Inner Chamber Made of stainless Steel 304 Sheet. Exterior Made of Mild Steel Sheet Finished In Powder Coated Color Combinations. Three sides Heating provides Uniform And Quick Temperature Rise In Range of 50*C To 250*C. Advance auto tune Pid Temperature Controlling with 0.1 Degree C resolution and Accuracy Size 455mm 455* 455* with 2 Trays provided with 2 Or 3 adjustable shelves . Workable on 220 V AC 50Hz single phase. It should be fitted with Modern Look 16*2 Alphanumeric LCD Display, on starting It should first display the Company Name on the screen. It should have Temperature and Timer in Built In one controller. Feather Touch Key operation for menu driven system. The menu driven system allow the user to set multiple parameters easily. timer preset and present value upto 99.99mins. J-Type/Pt-100 Type sensors data logger Rs. 232 Attachment. Alaram output is given when the process starts and system stop and when the Temperature Exceeds high limit/Low Limit. It should Have inbuilt real time Clock and name should be feedable fan relay for fan operation. Fan timing (On/Off) adjustable of menu pid parameters settable in menu (Paramenter) complete in all respect as per the direction and to the entire satisfaction of Engineer-In-Charge within all leads and Lifts. 1 No
3 3 Balance Analytical Capacity 200grms and Sensitivity 1Mg - Make :-Sartoris,Ohaus,Coleparmer,Qic - Automatic External Caliberation - Easy to read out LCD Display with Back light, - 2,00,000 internal resolutions. - Multification weighing unit as like GM,CT,Pcs. - Full tare Range up to Max capacity of the balance. - Couting weighting Function. - Standered Rs 232 interface. - Ss weighting Pan, Level indicator, Adjustable Fi, - Inbuilt Rechargable Battery For continuos use (optional) - Zero tracking function. - Max capacity 220 Gm. - Readability Gm-0.1mg. - Lineraity 0.002Gm. - Stabilization time -2-3 Sec. - Display- Large LCD with backlight Display. - Workshop temp -10-40C. - Tare Range - Full. - Pan Size -85 Mm. - Ce Certified, Gmp, Iso 27001,Iso14001 Certified. 1 No
4 4 Hot Plate (Rectangular) :- Provided With Temperature Controller Having Temperature Range upto 300 C for General Purpose. Ce Certified, Gmp, Iso 27001,Iso14001 Certified. 1 No
5 5 Oven:- double walled construction inner & outer chamber made of stainless steel 304 with self supports for wide range of shelf spacing supplied with two/ three removable perforated shelves outer double is made from stainless steel, walled door is provided with magnetic. Gasket, lock & key and door operated lamp illuminpation. The cabinet is mounted on castors. The Temperature should be controlled by Highly Intelligent Microprocessor Program. The Temperature range should be from Ambient to 250 C. Accuracy should be 0.1 C the Temperature controlled should be linked with timer. Advance Pid with Auto Tunning size :- (450mm x 450mm x 450mm). It should be manufactuered by WHO GMP Norms. The Manufacture should be have GMP (as per WHO) approval. It should meet the iso 13485:2012 safety standerds for Medical Devices and Ce marked. it temperature range: it should have big LCD Display. It should be menu driven setting it should have Audio Visual Alaram. It should have controlled fan opertation Ssr Outputs for Both heater and compressor Data logger with computer interface Rs 232 Pc softwear for data Record. It should be password Protected. Timer preset and present value upto 99.99 Mins. k type Sensor. Alaram output is given when the process starts and system stop and when the temperature exceeds high limit/low limit. it should have inbuilt real time clock. It should operate on 220volt to 50 Hz Led Indicationsfor: Heating, Cooling, Fan, Alaram and power, it should be iso certified, ce certified as per Europen standerds, it should be nsic certified. It should be Manufactuered as per GMP WHO standederds it should conform to medical Safety Devices standerds ISO 13485:2012 ISO 27001:2013 infromation security system ISO 14001:2015 Enviorment Management System Nabal certified must be Submitted. 1 No
6 6 Magnetic stirrer Sartoris,Ohaus, Coleparmer, Qic 2.0 - liter Capacity With Hot plate having rotation speed 0-1200 Rmp, electronically controlled, heating Element 300 Watt, Thermostatically controlled power supply 220Vac+/-25%, 47 to 53 Hz coated magnetic Stirrer Bars. Menu Drive system, LCD Display, Knob based Rotation Precisely setting of Rmp, Pt 100 Sesnor for the Temprature, Compect Design. 1 No
7 7 Tds Meter Pen Type of Range 1-1999 Ppm. resolution 10 Ppm. Accuracy +/- 0.1 full scale, Tds Factor 0.40-1.00 Operating Temperature 0-5 C and Normallization Temperature 25 C. 1 NO
8 8 Ph Meter Pen Type having Range 1.0 to 15.0 Ph resolution 0.1 Ph Accuracy +/- 0.1Ph, Automatic Temperatur Controller. 1 No
9 9 Micro Pipette:- Lightweight, Ergonomic design, Easy to calibrate and maintain, Auto cleavable Tip, One hand operation. Tip cone Manufactured of chemical Resistant material, Capacity 1000-5000 Ml. 2 No
10 10 Autoclave Universal vertical with internal height at least 750 mm, internal Dia at least 550 mm, Heating Element of at least 3000 watt. Boiler Fabricated From hard Copper/ Brass sheet Heavily lined inside. Outer jacket made of Thick gauge Mild steel finished in hammer tone Grey stove Enamel,Lid of gun metel and Highly Nickel plated faced to from steam tight joint ( with ring fixed on rim of boiler ) with swing type bolt / nuts , fitted with regulating valve of pressure adjustment of at least 20Lbs/in2, Pressure Range, Safety valve ,steam release cock, water level indicator,water drain Cock ,timer to at least for 2 hours Operation and adjustable in multiples of 15 minutes or less ,Auto cut offs 220 volts /50Hz Power operated and complete with perforated Aluminum baskets Spare Gaskets (2Nos) steam Power cable Plug and other accessories. 1 No
11 11 Supplying of Freezer 165 liters capacity, Temperature range (-) 20 Degree C to (+) 20 Degree C, Automatic stainless steel material inside, Hot enamel out side voltage range 160 V - 250 V, AC 50 Hz, Running Voltage 140 V, 250 V, AC 50 Hz with built up voltage stabilizer, Two Door, Three Trays, Forest Free type fully Automatic self drange detrosting PUFF insulation low noise compressor with locking system. 1 No
12 12 Supplying of Heating mantel (Made from (GLSSYARN) of PSI, India Equivalent make modal PSI-069 capacty 1 liter. It should with stand high Temperature up to 350 det C. The Body of the mantle should be spun one piece from non -Rusting Aluminum (upto 5.00 liters capacity) Duly stoving Painted. All the Heating mantles should be legged with special grade Mineral Wool to Work on 220/230 volts AC. 1 No
13 13 Providing colony counter digital, Hach/Merck/waters/qic. It should be fitted with automatic 4 digit LED Digital Display, counting plate with illuminated Standard ruling Ensure Clarity Differentiated and sharply defined Colonies . Each Touch of marking pencil in the digital increments the colony counts by '1" & The Glowing Led display Depicts The total Colony Counts . the Maximum Counts colony possible should be up to 9999 provided with a manual reset of digital dia play, On/Off switch, Counting Plate 100mm Die Lens,Chord and Plug to work on 220/230 V AC. 1 No
14 14 Providing of Pipette of variable with Capacity 100 to 1000 UL. 1 No
15 15 Providing Thermometer of reputed Make Having Range (-) 10 to 250 Degree Centigrade Zeal. 2 Nos
16 16 Chlorine Comparative. 1 No
17 17 Engaging of One No. Chemist for one year for sample testing complete in all respect within all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge. 365 Days
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail