Repair To Roof Treatment , Cgi Sheets/ Ac Sheets In Roofing , Wall Panelling , False Ceiling In Technical Area At Air Force Station Pathannkot, GE (AF) PATHANKOT-Punjab

Military Engineer Services-MES has published Repair To Roof Treatment , Cgi Sheets/ Ac Sheets In Roofing , Wall Panelling , False Ceiling In Technical Area At Air Force Station Pathannkot. Submission Date for this Tender is 03-11-2020. Shed Construction Tenders in GE (AF) PATHANKOT Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

25720209
Repair To Roof Treatment , Cgi Sheets/ Ac Sheets In Roofing , Wall Panelling , False Ceiling In Technical Area At Air Force Station Pathannkot
Open Tender
Indian
Punjab
GE (AF) PATHANKOT
03-11-2020

Tender Details

Repair To Roof Treatment , Cgi Sheets/ Ac Sheets In Roofing , Wall Panelling , False Ceiling In Technical Area At Air Force Station Pathannkot

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR TO ROOF TREATMENT, CGI SHEETS/ AC SHEETS IN ROOFING, WALL PANELLING, FALSE CEILING IN TECHNICAL AREA AT AIR FORCE STATION PATHANNKOT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Removing old tar felt, all loose dirt,old roof tiles,cement plaster cleaning the concrete surface including removal & cleaning of vegetation, fungus,mass small trees etc from the roof top with wire brush, removing the strips of lightening conductor including refixing the same after repair work and applying neat cement slurry @ 1.5Kg/Sqm complete all as specified and directed by Engineer-in-Charge. 1200 Sqm
2 2 Demolition of cement concrete ( unreinforced) in roof, floors (other than ground floors) etclcomplete all as specified and directed by Engineer-in-Charge. 27 Cum
3 3 PCC 1:2:4 40 mm thick type B-1 using 20 mm graded stone aggregate as in sub base , surface finished even and fair without using extra cement complete. 1175 Sqm
4 4 Rendering of 10mm thick in CM 1:4 over concrete surface on top of roof finished even and smooth without using extra cement mixed with water proofing compound pidi proof LW @ 200ml per 50Kg cement as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge (WPC shall be measured and paid separately). 1175 Sqm
5 5 Supply only liquid water proofing compound pidilite LW complete all as specified and directed by Engineer-in-Charge. 20 Ltr
6 6 Taking down cement plaster of any description on brick or stone walls, including raking out joints, hacking for keys, scubbing down with water etc and complete all specified and as directed by Eng.-in-charge. 25 Sqm
7 7 Rendering of 15mm thick in CM 1:4 over concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. 25 Sqm
8 8 Water proofing treatment provided with polymeric water proofing membrane 3 mm,90 micron weighing not less than 3Kg/Sqm on prepared surfaces vertical/horizontal laid over a coat of bitumen 85/25 @ 1.20Kg/Sqm, over a coat of bitumen primer 0.50Kg/Sqm one coat of bitumen 85/25 @ 1.20Kg/Sqm shall be provided over water proofing membrane as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge 1200 Sqm
9 9 Bringing approved earth outside Ministry of defence (MOD) land and forming embankments with approved earth including raising (or lowering) earth, spreading in 1st layer 25 cm thick and 2nd layer 20cm over bird net etc a watering, compacting and finishing to required gradient/shape on top of RCC Slab blast pen complete all as specified and directed by Engineer-in-Charge. ( Bird net shall measured and paid separatley)\n 2300 Cum
10 10 Bird control nets of polyolefin all weather proof co-polymer, machine knotting using CNC machine with DSLS technology for anti slip knotting, mesh size 20mmx20mm and diameter of twine 01mm with 2mm dia border rope including 2mm dia tie ropes braided/ standard rope of polyolefin coplymers at an interval of 10ft having length of 6ft including laying or fixing at any height / any location all as per manufacturers instructions complete all as specified and directed by engr-in-charge 3500 Sqm
11 11 Grasing levelling the area on top of RCC blast pen and prepare the bed to entire satisfaction of Engr-in-Charge complete all as specification and directed by Engineer-in-Charge. 3500 Sqm
12 12 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge. 300 Sqm
13 13 Taking down carefully (copper/aluminium) point wiring for ceiling fan/light fitting in ceiling and refixing the same in any position including replacing damaged material and lowering/rising the rod of ceiling fan if required complete and all as specified and directed by Engineer-in-Charge. 5 Each Point
14 14 Taking down carefully switch boards of any size and any description and boxes of such types on wall and refixing at same place duly modification over PVC panelling including necessary screws, washers, replacement of damage switches etc. complete all as specified and directed by Engineer-in-Charge. 5 Each
15 15 Supply and fixing in position suspended false ceiling system using E Grid suspended ceiling Grid system of M/S Everest Industries Ltd or India Gypsum. The size of Grid shall be 600x600mm with Alu powder coated frame work, main runner 39x24mm, cross tee 29x24mm and wall angle 22.2x22.2mm using 4/9mm thick High Pressure Stream cured non primered classic, designer variant E-Board ISI marked IS No 14862-2000. Fibre cement E Board to be placed in the grid of E Grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the purlins/self tightening screw in roof with butter fly clips complete all as specified and directed by Engr-in-Charge 300 Sqm
16 16 Dismantling framed wooden trusses span n exc 10 m of any description and in any position complete all as directed by Engr-in-Charge. 6 Each
17 17 Dismantling timber scantling in fillets, rails, posts, rafters, purlins etc. under 40 Sqcm in section framed work complete all as specified and directed by Engineer-in-Charge. 20 RM
18 18 S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 etc. .complete all as specified and as directed by the Engineer-in-Charge. 700 Kg
19 19 S & F rolled MS section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confirming to Fe 410-W quality B complete all as specified and directed by Engineer-in-Charge. 850 Kg
20 20 S & F MS works as in wind tie for roof flat iron fillet for securing wire mesh etc and similar works conforming to Fe 290-0 Gde E-165 including drilling holes as required all as specified and directed by Engineer-in-Charge. 15 Kg
21 21 Refixing and erection fixing old any thickness/size of rolled MS section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Charge 150 Kg
22 22 Refixing old any thickness/size of MS works as in wind tie for roof flat iron fillet for securing wire mesh etc and similar works including drilling holes as required complete all as specified and directed by Engineer-in-Charge. 10 Kg
23 23 Dismantling AC corrugated or semi corrugated sheets in wall cladding or roof coverings including ridges and make good of aluminium earthing strips after fixing of sheets complete all as specified and directed by Engineer-in-Charge. 795 Sqm
24 24 Dismantling GI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings including ridges and make good of aluminium earthing strips after fixing of sheets complete all as specified and directed by Engineer-in-Charge. 530 Sqm
25 25 Dismantling plain steel sheeting any gauge thickness, including naintal or similar pattern roof covering complete all as specified and directed by Engineer-in-Charge. 220 Sqm
26 26 Supplying and fixing for 6mm thick AC corrugated or semi corrugated sheets in roof coverings including fixing with "J" hooks etc. complete all as specified and directed by Engineer-in-Charge. 50 Sqm
27 27 Asbestos cement two piece adjustable serated ridge 6mm thick all complete all as specified and directed by Engineer-in-Charge. 10 RM
28 28 Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. 710 Sqm
29 29 Supplying and fixing in repair pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. 25 Sqm
30 30 Supplying and fixing in reapir 0.63mm thick galvanised with grade of zinc coating 275gm/sqm mild steel sheeting (with grade of zinc coating 275 Gm/sqm) with two corrugation side lap fixed with L- type or cranked hook bolts and washer in roof, wall etc bent to curve complete all as specified and directed. 470 Sqm
31 31 Supplying and fixing in reapir 1.00 mm thick plain black mil;d steel sheeting in ridges, hips, valley gutter, drip and straight flashing fixed with any shape and providing 60 mm lap each joints with riveted or welded seams, including bending complete all as specified and directed by Engineer-in-Charge. 260 Sqm
32 32 Preparing new steel surfaces of any description over 10 cm in width or girth and applying two coats sythetic enamel paint over one coat of aluminium red oxide primer complete all as specified and directed by Engineer-in-Charge. 260 Sqm
33 33 Preparing new steel surfaces of any description over 10 cm in width or girth and applying two coats sythetic enamel paint of camouflage pattern de-galvaning with one coat of 'H' primer in four or more shades as directed by Engr-in-charge including necessary scaffolding and other safety arrangement to work at any height at site complete all as specified and directed by Engineer-in-Charge. 470 Sqm
34 34 Refixing old any thickness Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc complete all as specified and directed by Engineer-in-Charge. 50 Sqm
35 35 Refixing old any thickness Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and directed by Engineer-in-Charge. 10 Sqm
36 36 Demolition brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge. 1 Cum
37 37 Brick work with sub class 'B' modular brick straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 1 Cum
38 38 Preparation of new surfaces and applying two coats of exterior acrylic paint of any shade in comouflage pattern as approved by GE over a coat of self primer on newly plastered surfaces of walls/AC Sheets as per manufacturer's instrucitons complete all as specified and directed by Engineer-in-Charge. 60 Sqm
39 39 Preparing new steel surfaces of any description exc 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engineer-in-Charge. 80 Sqm
40 40 Preparation of steel surfaces of any description, not otherwise described, not exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. 5 10 RM
41 41 Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed by Engineer-in-Charge including dismantling existing water tank and removing from site of any capacity. 10 Each
42 42 All as per item No 41 above but except water tank complete and all as specified and as directed by Engineer-in-Charge 5 Each
43 43 Supply and fixing in repairs 20 mm bore float valve of high pressure PTMT with epoxy coated aluminuim rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge. 3 Each
44 44 Taking up or down GI tubing 25mm bore including cleaning for refixing complete all as specified and directed by Engr-in-Charge\n 5 RM
45 45 Taking up or down GI tubing 20mm bore complete all as specified and directed by Engr-in-Charge. 10 RM
46 46 Supply and fixing 25 mm tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 15mm) complete all as specified and directed by Engr-in-Charge 3 RM
47 47 Refixing old steel tubing and connections of 25mm dia in new or old position (wall, ceiling, floors etc.) complete all as specified and directed by Engineer-in-Charge. 2 RM
48 48 Supply and fixing 20 mm tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 15mm) complete all as specified and directed by Engr-in-Charge 5 RM
49 49 Refixing old steel tubing and connections of 20mm dia in new or old position (wall, ceiling, floors etc.) complete all as specified and directed by Engineer-in-Charge. 5 RM
50 50 Dismantling of Rain water pipe of AC or PVC or any type fixed to wall of wall cladding with MS strap of any diameter .complete all as specified and directed by Engineer-in-Charge. 40 RM
51 51 S&F 150 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joint fixed to wall /wall cladding complete all as specified and directed by Engineer-in-Charge. 40 RM
52 52 S&F of 150 mm dia PVC (SWR) bends as a shoes of rain water complete all as specified and directed by Engineer-in-Charge. 4 Each
53 53 S&F of bands , straps supports of stays for rain water pipe, strap for valley gutter and one extra angle welded to existing window frame to fix the two window panes in one fixed type window . Similar small article confirming to FE -290-Gde -E -165 complete all as specified and directed by Engineer-in-Charge. 5 Kg
54 54 S&F for posts and struts in fencing including cutting tops to shape as directed, drilling holes, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge. 80 Kg
55 55 S&F for 4mm mild steel wire, galvanised class 3, in any postion including straining and fixing to steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc.complete all as specified and directed by Engineer-in-Charge. (each line of wire to be measured) 50 100 RM
56 56 Re-securing and restraining GI Wire including making good complete all as specified and directed by Engineer-in-Charge. 30 100 RM
57 57 Cement concrete in foundation filling and mass concrete, Type B-2 (1:2:4)using 40 mm graded aggregate complete all as specified and directed by Engineer-in-Charge. 1 Cum
58 58 Demolition of cement concrete of any description and in any position not otherwise specifically complete all as specified and directed by Engineer-in-Charge. 1 Cum
59 59 Providing PCC 1:2:4 type B1 using 20mm graded stone aggregate including necessary formwork as in cills, steps, seismic & other similar bands, string course, lacing course, parapets & railing up to 60cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles & throating complete all as specified and directed by Engineer-in-Charge. 1 Cum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail