}

Construction Of Godowns/Warehouse For Proper Storage Of Evms And Vvpats In The50 Election Districts Of Assam For The Year 2017-18 ( Deo Kamrup ) ( Balance Work ) , Kamrup-Assam

Public Works Department-PWD has published Construction Of Godowns/Warehouse For Proper Storage Of Evms And Vvpats In The50 Election Districts Of Assam For The Year 2017-18 ( Deo Kamrup ) ( Balance Work ) . Submission Date for this Tender is 21-10-2020. Building Work Tenders in Kamrup Assam. Bidders can get complete Tender details and download the document.




Tender Notice

25640264
Construction Of Godowns/Warehouse For Proper Storage Of Evms And Vvpats In The50 Election Districts Of Assam For The Year 2017-18 ( Deo Kamrup ) ( Balance Work )
Open Tender
Indian
Assam
Kamrup
21-10-2020

Tender Details

Construction Of Godowns/Warehouse For Proper Storage Of Evms And Vvpats In The50 Election Districts Of Assam For The Year 2017-18 ( Deo Kamrup ) ( Balance Work )

Key Value

Document Fees
INR 2600 /-
EMD
INR 151861.0 /-
Tender Value
INR 75.93 Lakhs /-

BOQ Items

Name of Work: Construction of godowns/warehouse for proper storage of EVMs and VVPATs in the50 election districts of Assam for the year 2017-18 ( DEO Kamrup ) ( Balance work )
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Upto a depth of 2.00 m below the existing G.L.\na)In ordinary soil 51.77 m3
2 2 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. 699 m3
3 3 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)\n (a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine). 8.14 m3
4 4 Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)\n(I)Using mixture machine.\n (A) In sub - structure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture...\n(b)M20 or Prop. 1:1.5:3\n 40.71 m3
5 5 Providing and laying plain/reinforced cement croncrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately) \nI) Using mixture machine\n(B) Super-structure from plinth level upto 1st floor level.\ni) Vertcal members (Column, pillars, post, struts etc)\nN) Without using admixture, plasticiser\n(a) M15 or Prop. 1:2:4 15.95 Cum
6 6 Providing and laying plain/reinforced cement croncrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately) \nI) Using mixture machine\nB) In super structure up to 1st floor level\nii) Horizontal members like beam, lintel, girder bressumer etc.\nN) Without using admixture, plasticiser\n(b) M20 or Prop. 1:11/2:3 6.8 Cum
7 7 Providing and laying plain/reinforced cement croncrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately) \nI) Using mixture machine\n(B) Super-structure from plinth level upto 1st floor level.\niii) Suspended floor (Slab, balcony, staircase etc)\nN) Without using admixture, plasticiser\n(b) M20 or Prop. 1:11/2:3 4.25 Cum
8 8 Extra for every subsequent floor above 1st floor 6.452 Cum
9 9 Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. 350 m2
10 10 Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed\n(I) in sub-structure up to plinth level.\n(b). In proportion 1:3.(1 cement:3 sand) 5.4 m3
11 11 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(b) In cement mortar in proportion 1:5. \n(1 cement:5 sand) 135.55 Sqm
12 12 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.\n(b) 20 mm thick 62 Sqm
13 13 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\nb) Executive range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make\ni) Of size 800mmx800mm and above 769.55 Sqm
14 14 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\n(B)VITRIFIED\niii)Executive range-2 (Sizes 600 mm x600mm and above)\ni) Nitco made\na). Imperia Series- Gres Tiles 7.13 Sqm
15 15 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).\nb) Executive range \nSomany/ Orient/Nitco/Asian Make\nii) Of size 250mmx350mm and above 44.18 Sqm
16 16 Providing SUN ROCK HIGH CTS/DEVI paver block/tiles of concrete grade M30 or above of approved quality, size, shape of specified thickness over a levelling bedding layer of 30mm compacted sand over a base course of WBM or PCC (Base course to be paid separately) including cutting where necessary finished with spreading, sweeping jointing sand and compacting the pavers using compactor as specified and directed.\n(A) SUN ROCK HIGH CTS / Devi Tiles (Pavers)\n(a) 80 mm thick 136.16 Sqm
17 17 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\n(a). In cement mortar in proportion 1:3.(1 cement:3 sand) 110.16 Sqm
18 18 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side\n(a). In cement mortar in proportion 1:3.(1 cement:3 sand) 243.27 Sqm
19 19 Extra over item no above for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.\nb) On two coat plaster 36.91 Sqm
20 20 Extra over item no above for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed.\nb) On two coat plaster 0.34 Sqm
21 21 Grading roof for water proofing treatment with \n(b) Cement mortar \n(i) 1:3 (1 cement: 3 coarse sand) \n 25.75 Cum
22 22 Providing fitting and fixing compressed ready to fit Godrej make wood door shutter (Godrej Entranza Moulded Panel Door) for various thickness Conforming to IS 15380-2003,printed,shutter comprising of High Density Fiberboard skins (HDF) of 3.5 mm (hardened finely processed natural wood fibre) with panel design compressed on both faces,sandwitching, termite and borer resistant chemical treated and kiln seasoned wooden stiles and rails of 50mm-60mm width,lock block and high density flax board core / chemical treated and kiln seasoned timber core infil. The panel would be of different design viz. Two panel,Four panel,Six panel (both side) Shutter should be bonded with Phenol Formaldehyde or adhesive / conforming to BWP grade of IS 848.Shutter should have trim ability option of 12.5 mm from all sides. The door should have flexibility for painting or polishing to match any interiors. \n(iii) 45 mm thick with panel inserts of 20mm thickness. 6.3 Sqm
23 23 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. \na) Decorative type face panel and block board core.\n(i) 40 mm thick . 5 Sqm
24 24 Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nI Ornamental grill\n(c). Fixed to Brickwork/P.C.C/R.C.C. 1660.5 kg
25 25 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(a)2 Track sliding window\n(i)6mm clear glass 11.48 sqm
26 26 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white). 75.6 Sqm
27 27 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). 75.6 Sqm
28 28 Extra over item no above for every subsequent coat of paint. \n(i).Surfaces over 100mm in width or girth.\nb). High glossy purpose ( Berger paint/ ICI paint). 75.6 Sqm
29 29 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick 2980 Sqm
30 30 a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. 2980 Sqm
31 31 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture ( Berger paint/ ICI paint) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Plastic Emulsion Paint of approved brand and manufacture ( Asian paint/Berger paint/ ICI paint) 1794.11 Sqm
32 32 Extra over item no above above for every subsequent coat of wall painting with Plastic Emulsion Paint of approved brand and manufacture ( Berger paint/ ICI paint).\n(i).Plastic Emulsion Paint of approved brand and manufacture ( Asian paint/Berger paint/ ICI paint) 1794.11 Sqm
33 33 Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) 946.11 Sqm
34 34 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\na) Sliding door bolts\nii) 250mm x 16mm\n 9 Each
35 35 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nb) Tower bolts\nii) 250mm x 12mm\n 18 Each
36 36 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nc) Door handles\niii) 150mm\n 18 Each
37 37 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nt) Door stopper with rubber stopper\n\n 7 Each
38 38 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nm) Mortice lock vertical type\ni) 65mm (Godrej with handle (2-lever) 4 Each
39 39 Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts). 8.8 Qtl
40 40 Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or combination all of the following sections (i) Square section (ii) Rectangular Hollow section . red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. \na) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997 3.75 Qtl
41 41 Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. ..\n(a) 1.25mm thick sheet\n(iii) Size 125mm x 60mm (Single rebate) 25 M
42 42 Supplying , fitting and fixing galvanised barbed wire fencing with seven strands of barbed wire 12 S. W. G .x 2plies x 4 points at 75mm apart with angle iron intermediate fencing posts .... \na) Intermediate post 35mm x35mm x5mm x1800mm long bottom torched and duly slotted.\nb) Straining post 65mm x 65mm x 6mm x 1820mm long with 2 stays of 35mmx35mmx1520mm long and 3 base plates 200mm x 200mm x 5mm, duly slotted to take eye bolts etc.\nc) Corner posts 65mm x 65mm x 6mm x1820mm long with 2 stays of 35mm x 35mm x 5mm x 1 670 mm and 3 base plates 200mm x 200mm x 5mm,duly slotted to take eye bolts etc. \nd) Straining or end posts 65mmx 65mm x 6mmx 1820mm long with 1 stays of 35mm x 35mm x 5mmx 1820 mm long with base plates 200mmx 200mm x 5mm, duly slotted to take eye bolts etc. \n 55 M
43 43 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(ii)Super Ductile (SD) TMT reinforcement bars 8 qtl
44 44 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/ Jindal steel/Shyam steel/RINL\nb) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)\n (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. . 9 Qtl
45 45 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \nc) ISI approved Mild steel reinforcement bar(M.S.Bar) 3.5 Qtl
46 46 Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge.\n(For payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered) 205.4 Kg
47 47 Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished. 75.6 Sqm
48 48 Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished...\nii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. 35 Rm
49 49 Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg)\nBRAND : FIRESTOP / FIREND / FIRE SHIELD/GETECH/MINIMEX 4 Each
50 50 Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint. 26 Sq.m.
51 51 Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary. 59.4616 Sqm
52 52 Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\nA) Parryware make\nb) Coloured\n(ii) Combination Closet S Trap (Cat No.C0205) (inclusive of seat cover) 2 Each
53 53 Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)\n1.1.1 Indian type W.C Orissa pattern of size 580 x 440 mm \nb) Coloured\ni) Parryware make 1 Each
54 54 Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\nA) Parryware make\nb) Coloured\n(iv) Deluxe Dual Flush (Cat No.C8110) 3 Each
55 55 Providing fitting and fixing Decorative Mirror complete as directed and specified.\n(B) Jaquar Make \n(a) Double Arm Wall Mounted reversible plain / Magnifying (3X) Pivotal Mirror (Cat. No.ACN-1193N) 2 Each
56 56 Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.\n(i) Jaquar Make \n(e) Hotelier (Cat. No.AHS-1531) 5 Each
57 57 Providing, fitting and fixing CP towel rail complete as directed and specified.\n(a) Jaquar make \n(i) Continental 300mm for wash basin (Cat.No. ACN-1101N) 5 Each
58 58 Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\n1.13.1 PEDESTAL BASIN (with pedestal)\n(C) Jaquar Make\n(a) White\n(vi) Vignette (Cat. No. VGS-WHT-0612) 2 Each
59 59 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \n(a) In exposed surfaces or in trences.\n(i) 160mm dia. 75 Rm
60 60 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 26.48 Rm
61 61 Providing fitting and fixing PVC pipes of 6 Kg/cm2 ( Supreme / Prince ) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 15 Rm
62 62 Sipplying fitting and fixing of 87.5 degree PVC bend ( Supreme / Prince ) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(i) 160mm 15 Each
63 63 Sipplying fitting and fixing of 87.5 degree PVC bend ( Supreme / Prince ) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 10 Each
64 64 Sipplying fitting and fixing of 87.5 degree PVC bend ( Supreme / Prince ) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 10 Each
65 65 Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(i) 160mm dia 15 Each
66 66 Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 10 Each
67 67 Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 8 Each
68 68 Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(i) 160mm dia 10 Each
69 69 Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 10 Each
70 70 Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 15 Each
71 71 Sipplying fitting and fixing PVC plain single tee of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(i) 160mm dia 15 Each
72 72 Sipplying fitting and fixing PVC plain single tee of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 15 Each
73 73 Sipplying fitting and fixing PVC plain single tee of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iii) 90 mm dia. 10 Each
74 74 Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(i) 160mm dia 10 Each
75 75 Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 15 Each
76 76 Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 15 Each
77 77 Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(i) 160mm dia 15 Each
78 78 Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 15 Each
79 79 Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 10 Each
80 80 Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 10 Each
81 81 Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 15 Each
82 82 Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 10 Each
83 83 Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 10 Each
84 84 Supplying fiting and fixing PVC double ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(ii) 110mm dia. 10 Each
85 85 Supplying fiting and fixing PVC double ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(iv) 75 mm dia. 10 Each
86 86 Sipplying fitting and fixing PVC cross'T' plain of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iii) 110 mm x 110mm 10 Each
87 87 Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \n(a) In exposed surfaces or in trences.\n(iii) 110 mm x 110mm 10 Each
88 88 Sipplying fitting and fixing PVC coupler of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iii) 110 mm dia. 15 Each
89 89 Sipplying fitting and fixing PVC coupler of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(ii) 75 mm dia. 10 Each
90 90 Sipplying fitting and fixing PVC reducer of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(iii) 160 mm x 90mm 20 Each
91 91 Sipplying fitting and fixing PVC reducer of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(vi) 90 mm x 75mm 10 Each
92 92 Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trences.\n(i) 160mm x 110 mm 10 Each
93 93 Supplying fiting and fixing PVC reducing Tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trenches as necessary complete at all levels including below G.L. as directed and specified.\n(i) 160mm x 110 mm 3 Each
94 94 Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified.\n(a) 110 mm 20 Each
95 95 Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified.\n(b) 75 mm 15 Each
96 96 Supplying fiting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. \n(b) 110 mm 15 Each
97 97 Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.\n(iii) 90mm dia. PVC cowel of ISI make 1 Each
98 98 Providing fitting & fixing C.P. Grating to the floors complete as directed and specified.\n(ii) 75mm dia. 2 Each
99 99 Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\n(C) Jaquar Make\n(a) White\n(i) Compact (Cat.No.URS-WHT-0702) 4 Each
100 100 Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified. 2 Each
101 101 Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. 3 Each
102 102 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand as directed and specified. (G.I. & C.P pipes will be measured separately) \n( II) Jaquar make\n(a) Continental / Clarion \n(ii) Bib cock long thread\n 10 Each
103 103 Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) \n(I) Jaquar \n(a) Continental / Clarion \n(i) 15mm dia Male/Female (long thread) 6 Each
104 104 SSupplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. \n(II) Jaquar make \n(b) Continental 4 Each
105 105 Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) \nV) Jaquar brand\na) Continental / Clarion\ni) Sink cock with swinging casted spout 4 Each
106 106 Supplying fitting and fixing Chrome Plated (C.P.) flush cock of approved brand as directed and specified.(G.I. & C.P pipes will be measured and paid separately) \n(III) Jaquar brand\n(a) Continental / Clarion \n(i) Flush cock with wall flange 25mm size with lever handle 5 Each
107 107 Labour for boring for boring hole for inserting tube well pipes through different soil/ rock median including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the deptt.\nBore hole of 200 mm dia . 80 Rm
108 108 Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.\n(II) PVC PIPE, SUPREME /PRINCE / FUSION /SFMC Brand\nvi) 140mm diameter 75 Rm
109 109 Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.\nA) G.I. pipe, \n a) TATA / SAIL (Medium)socket should be welded to the pipes.\niv) 50mm diameter 75 Rm
110 110 Supplying fitting and fixing GI filter 2.00 metre long. 1 NO
111 111 Supplying fitting and fixing check valve (non return valve) including thread to pipes.\niii) 40mm diameter 2 NO
112 112 Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained\niii) 40mm diameter 1 JOB
113 113 Flushing, clearing, washing and watering of the tube well 1 JOB
114 114 Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified.\n(A) Exposed or in trenches\nSUPREME/ PRINCE/ SFMC BRAND ..\nb) 40 mm dia 22 RM
115 115 d) 25 mm dia 20 RM
116 116 Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes\n(III) 1000 litre capacity \n(a) Sintex make 2 Each
117 117 Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc)\n(A) TMT bar made of Primary producer (From Primary producer) 19 qtl
118 118 Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 .b) Pile Dia 300 mm 45 r.m.
119 119 Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement\n(ii) 300 mm dia 45 r.m.
120 120 Empty boring for specified diameter piles from ground level to cut-off level.\nd) Pile Dia 300 mm 45 r.m.
121 121 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete\n Medium point up to 6.00 metre. Length. 45 Each
122 122 Long point up to 10.00 metre. Length. 43 Each
123 123 Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.\nShort point up to 3.00 metre. length. 15 Each
124 124 Medium point up to 6.00 metre. Length. 2 Each
125 125 Long point up to 10.00 metre. Length. 15 Each
126 126 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\nMedium point up to 6.00 metre. Length. 8 Each
127 127 Long point up to 10.00 metre. Length. 3 Each
128 128 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 17 Each
129 129 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 900 Mtr
130 130 With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 350 Mtr
131 131 With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 100 Mtr
132 132 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system .\nWith 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 50 Mtr
133 133 With 3 x 6 sq. mm. + earth continuity with2x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 150 Mtr
134 134 With 3 x 10 sq. mm. + earth continuity with2x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. 120 Mtr
135 135 Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.\n100 watt electronic modular 4 step speed control 2 - module type 50 Mtr
136 136 Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 20 Each
137 137 Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 1 Each
138 138 Supplying including installation of socket outlet 6 Amps 3 pin universal combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 20 Each
139 139 Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 25 Each
140 140 Supplying with fitting fixing of 16 amp one way modular clip in switch with LED, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 128 Each
141 141 Supplying with fitting fixing of 6 amp two way modular clip in switch , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 20 Each
142 142 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.\n3 module type Metal 2 Each
143 143 4-5 module type Metal 45 Each
144 144 6-8 module type Metal 17 Each
145 145 10 module type Metal 8 Each
146 146 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.\n2 module 2 Each
147 147 3 module 4 Each
148 148 4 module 45 Each
149 149 5 module 12 Each
150 150 6 module 5 Each
151 151 8 module 6 Each
152 152 10 module 2 Each
153 153 Supplying with fitting and fixing of electronic chime MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 2 Each
154 154 Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department. 1 Each
155 155 Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)\nEnergy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make 15 Each
156 156 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\nDomestic\nHeavy Duty 600 mm sweep 900 RPM Single phase (Usha make) 20 Each
157 157 Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . 7 Each
158 158 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. 4 Each
159 159 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. 4 Each
160 160 Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. 60 Mtr
161 161 Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt. 2 Each
162 162 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n 4 way SPN double door 60 Mtr
163 163 12 way SPN double door 1 Each
164 164 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) \n4 way TPN (8+12) double door 2 Each
165 165 Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n 4 way TPN (4+12) double door 2 Each
166 166 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nB Series\n6 to 32A 1 Each
167 167 40A 20 Each
168 168 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nB Series\n40A 20 Each
169 169 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nB Series (Schneider MG, legrand, Hager make)\n40A 2 Each
170 170 63A 2 Each
171 171 Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt\n25 KA 415V 50 Hz 4P MCCB \n(Schneider, legrand, Siemens, Indo Asian make) \n.63A 3 Each
172 172 Supplying, installation. testing and commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no- DN 393 B LED 12 S-6500 PSU WH/ D01257R000/D01240R000/ D01230R000/ CRDL11R017HP57 complete with all accessories such as ballast, starter etc. in the false ceiling type Armstrong/ Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C. copper conductor as required and as directed by the department (Jaquar/ LT/ Wipro make) 1 Each
173 173 Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 sq.mm. 1 core PVC insulated round copper conductor as required and as directed by the department. \nLGLZ01X 020XC/ LGLZ0 X 020XCN/ LGLZ01X 020XCW (20W) 12 Each
174 174 Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp 50 Each
175 175 Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten/ ange holder as required and as directed by the department (Jaquar or eqvt. Make) \nPrima series Bulb 9W 9 Each
176 176 Supplying, installation, testing and comissioning of the fowing integral flood lighting luminaries con forming to IP65/ IP66 suitable for vertical and horizontal mounting application pressure die cast powder coated aluminium alloy housing with corrosion resistance powder coating using nano Technology transprent injection moulded poly carbonate UV stabilized diffuser having high impact strength to withstand min IK09 with high power LED and unique flood optics to ensure uniform light distribution and maintenance free system ideal for area lighting, high mast lighting, sports lighting and billboard. The luminaries should be equiped with external surge protection device to withstand 10KV/5KV including connection with 2.5 sq.mm. 3 core PVC insulated round copper conductor as required and as directed by the department.\nBVP 120 LED 35 CW FG SI PSU GR 9 Each
177 177 Supplying installation testing and commissioning of - 1/3" Super HAD CCD II,600 TVL Dome Camera, Min Illumination : 0.15 Lux @ F 1.2, Built in fixed lens : 8 mm, Compact Dome Camera (8mm), 600TV lines resolution (SAMSUNG or equivalent HONEYWELL/PANASONIC make) 4 Each
178 178 Supplying installation testing and commissioning of - Weatherproof IR Camera, 600 TVL (Colour) / 700 TVL (B/W), 1/3" Super HAD CCD, Min Illumination 0 Lux (IR LED on), IR Distance 50 M, Built in V/F lens 2.8 ~ 10 mm, True Day & Night (ICR), IP 66 (SAMSUNG or equivalent HONEYWELL/PANASONIC make) 15 Each
179 179 Supplying installation testing and commissioning of - 16ch DVR, H.264, 200 (PAL) fps recording rate ,Up to 4ch audio inputs and 1ch audio output , MAX 5 internal HDD (HDD x 5) ,Built-in web viewer, DVD R/W (SAMSUNG or equivalent HONEYWELL/PANASONIC make) 4 Each
180 180 Supplying installation of BNC connection per Pair ()X make 2 Each
181 181 Supplying installation testing and commissioning of Hard Disk For DVR 2 TB (SEAGATE / WD make) 40 Each
182 182 Supplying installation testing and commissioning of Power Supply SMPS Based 12V For 8 Camera (PROTEK make) 2 Each
183 183 Supplying installation testing and commissioning of 22" LCD TFT Screen (SAMSUNG / ball / LG / MITASHI make) 4 Each
184 184 Supplying including installation of UPS\n1 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology 230V AC Input (160V – 280V A 1 Ph input- 1 Ph output With Isolation Transformer\n0.8KW output with 0.8 output PF 30 min backup using SMF battery 2 Each
185 185 Supplying, installation of LAN works accessories as directed and specified and directed by the Deptt.\nAPW Flexi box Wall mount Rack 6U 19"X 500mmD Networking Wall mount Rack with Front Tinted Glass Door with Lock "PDU 6*5A - 01 Nos.\nFan 90 cfm 230V - 01 Nos.\nMounting Hardware (Set of 10) - 1 Set\n19"" 1U Cable Manager - 1 Nos." 2 Each
186 186 Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required: 1 Each
187 187 Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. 665 Mtr
188 188 Co - axial Jelly Flooded (Unarmoured) RG 6 (Copper) 665 Mtr
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail