Repair Servicing And Maintenance To Electrical And Mechanical Installations At Sbtf Goa, SBTF GOA-Goa

Defence Research And Development Organisation -DRADO has published Repair Servicing And Maintenance To Electrical And Mechanical Installations At Sbtf Goa. Submission Date for this Tender is 15-10-2020. Washers Tenders in SBTF GOA Goa. Bidders can get complete Tender details and download the document.




Tender Notice

25571858
Repair Servicing And Maintenance To Electrical And Mechanical Installations At Sbtf Goa
Open Tender
Indian
Goa
SBTF GOA
15-10-2020

Tender Details

Repair Servicing And Maintenance To Electrical And Mechanical Installations At Sbtf Goa , note :- i ) cost of cleaning / lubricating materials & items like gaskets , washer , gromets nuts , bolts etc are deemeed to be included in rated quoted for servicing / repairing . ii ) cost of spares if any needs to be replaced for efficient functioning of equipment will be measured and paid separately as per oem price list & tax invoice of oem / authorised service providing agency ( unless specified in the item ) by adding 10% for oh & cp . iii ) cost of fixing and commissioning of spares is deemed to be included in the quoted rate of repair / servicing respective item . v ) service / inspection report of installations for servicing / repair & tax invoice of the oem / authorised service agencies for the spares used need to be submitted for release of payment . , dg set providing b check of dg set ( after 300 hrs / 6 months which comes earlier ) including changing of fuel filter , lub oil filter , separator ( fuel & oil ) , premix coolent , engine oil , inhibitor corrossion by the authorised service engineer of the oem and testing thereof as directed by engineer-in-charge , a ) dg set 750 kva - model kta 38 - g1 , b ) dg set 380 kva - model nta 14 - g3 , c ) dg set 125 kva- model - 6 btaa 5 . 9 g1 , d ) dg set 82 . 5 kva - model - 6 bt - 5 . 9 - g1 , fire extinguishers , repair / servicing of fire extinguishers consisting:- , i ) opening , cleaning , treating of fire extinguisher & cartridge ii ) opening , cleaning , treating of hose iii ) weight checking of cartidge & extinguisher iv ) reassembling back after replacing new refiling cartridge & defective hose v ) testing fire exitinguisher in presence of users rep ( wherever applicable ) vi ) refixing the fire extinguisher after weight checking , metalic sealing ( old or new wherever replacement required ) fixing sticker of showing details of refiling on , refilling due date hpt on hpt due date ( where applicable ) , fire extinguishers ( spares ) , i ) discharge hose with horn , ii ) refilling new cartidge mechnical foam type ltr capacity , iii ) refilling / cartridge dcp 9 kg capacity , iv ) refilling / cartridge dcp 6 kg capacity , v ) refilling / cartridge 2 kg dcp capacity , vi ) refilling / cartridge co2 type 4 . 5 kg capacity , ht cable work , a ) pinpointing the fault ( first fault ) on existing aluminium armoured cable , 11 kv grade of size 3 c x 185 sqmm in a length of approx . 2000 mts with the help of vehicle mounted ht fault detection machine all as directed . , b ) additional faults ( if any ) over above item 3 ( a ) above , excavation in trenches and taking out defective cable , supply of 11 kv xlpe grade multi core stranded aluminium conductor ( e ) xlpe insulated and pvc sheathed armoured cable of size 3 core 185 sqm confirming to is 7098 ( pt 1 ) 1988 complete as required as specified , supply of following size of 1 . 1kv grade multicore aluminium conductor xlpe insulated & pvc sheathed armoured power cable as per is: 7098 ( part-1 ) 1988 complete as required . , a ) 3 . 5 core , 185 sqmm , b ) 3 . 5 core , 95 sqmm , laying of one no . of xlpe insulated and pvc sheathed power cable of 11 kv grade / 1 . 1 kv grade cable of following size in ground inclding excavation , sand cushioning , protective covering and refilling the trench complete , a ) 11 kv 3 core 185 sqmm , b ) 3 . 5 core , 185 sqmm , c ) 3 . 5 core , 95 sqmm , supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrule suitable for 3 core xlpe aluminium conductor cable of size 11 kv 185 / 240 sqmm including conducting hypo test after jointing all as required , supply and making indoor end termination with heat shrinkable jointing kit complete with all accessories including lugs , nut bolts suitable for 3 core xlpe aluminium conductor cable 11 kv grade of size 185 sqmm all as required , all as per item no . 8 above but outdoor type , straight through cable jointing kit with heat shrinkable kit with ferrules for 3 1 / 2 x 185 sq . mm 1 . 1 kv grade cable , all as per item no . 10 above but for 3 1 / 2 x 95 sq . mm 1 . 1 kv grade cable , cable end termination with aluminium lugs for 185 sq . mm cable , all as per item no . 12 above but for aluminium lugs for 95 sq . mm cable , all as per item no . 12 above but for aluminium lugs for 50 sq . mm cable , transformer oil filtration & testing , a ) dehydration / filtration of transformer oil of installed transformer so by circulating through trolly mounted filteration plant till achiving die-electric strength 50 kv at the gap of 2 . 5mm , b ) conduting acidity test of transformer oil of installed transformer , c ) supply and replacing slilica gel of breather , d ) supply of new insulating oil as per is having die-electric strength not less 60 kv for topping up / replacement , servicing and calibration of vcb , a ) serivicing / periodical maintenance of 33 kv outdoor vaccum circuit breaker ( vcb ) by service engineer / technician of oem including servicing , calibration , setting of all types of relays . fixed on vcb panel board all as directed and thereafter testing & calibration at site as requird ( abb make ) , b ) all as per item no . 16 ( a ) above but for 11 kv vcb indoor type ( siemens make ) , overhauling of 33 kv oil immersed outdoor current transformer by replacing insulating oil , gasket , bushing kit etc and thereafter testing completely by using primery injection kit all as required at site for efficient functioning of installation , a ) all as per item no . 17 above but for 33 kv outdoor potential transformer , note:- cost of insulating oil for item 17 & 18 ( a ) above will be measured and paid separately under relevant item at si no . 15 ( d ) above , b ) conducting testing of resin cast ct by using standard primery injection kit all as required at site as per ie rule , overhauling / repair of lt 3ph air circuit breaker of capacity 2000 amps / 1250 amps / 800 amps as per technical guideline of oem and testing thereafter all as required at site ( siemens / l&t make ) , repair / servicing of calibration of soft starter 3 ph 415 v , 162a / 230 amp all as per technical guide lines of oem ( simens ) and setting starter as per technical parameter of pumpset all as required ( siemens make ) , a ) repairs to 15 kva ups including replacing maintenance free batteries as required and testing thereafter for rated output all as required at site , b ) repair to 6 kva ups including replacing pcb / master card etc as required and testing thereafter for rated output mentioned in oem specification , servicing of 3 ph 50 hz , voltage stabilizer all as per guide line given in technical parameter of oem of cap - 100 kva / 60 kva / 30 kva / 25kva and testing thereafter for rated output as per design of oem ( consul make ) , repair / overhauling of 3 ph , 415 v voltage stabilizer 100 kva / 30 kva capacity by replacing defective parts like relays , pcb , master card etc if required , note:- cost of batteries / pcb / master card / relay etc if replaced under items 21 & 23 above will be measured and paid under spares ) , a ) repair and servicing

Key Value

Document Fees
INR 500 /-
EMD
INR 53500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/Servicing and Maintenance to E&M installations of SBTF at INS Hansa Goa
Sl. No. Item Description Item Code / Make Quantity Units
1 1 NOTE :- i) Cost of cleaning / lubricating materials & Items like Gaskets, Washer, gromets nuts, bolts etc are deemeed to be included in rated quoted for servicing/ repairing. ii) Cost of spares if any needs to be replaced for efficient functioning of equipment will be measured and paid separately as per OEM price list & Tax invoice of OEM/ Authorised service providing agency (Unless specified in the item) by adding 10% for OH & CP . iii) Cost of fixing and commissioning of spares is deemed to be included in the quoted rate of repair/ servicing respective item. v) Service/inspection report of installations for servicing / repair & Tax invoice of the OEM/ authorised service agencies for the spares used need to be submitted for release of payment. BI01010001010000000000000515BI0100001112
2 2 DG SET Providing B check of DG set (After 300 hrs / 6 months which comes earlier) including changing of fuel filter, lub oil filter, Separator (Fuel & oil), Premix coolent, Engine oil, Inhibitor corrossion by the authorised service Engineer of the OEM and Testing thereof as directed by Engineer-in-charge BI01010001010000000000000515BI0100001112
3 3 a) DG set 750 KVA - Model KTA 38 - G1 BI01010001010000000000000515BI0100001113 2 Job
4 4 b) DG set 380 KVA - Model NTA 14 - G3 BI01010001010000000000000515BI0100001113 2 Job
5 5 c) DG Set 125 KVA- Model - 6 BTAA 5.9 G1 BI01010001010000000000000515BI0100001113 2 Job
6 6 d) DG set 82.5 KVA - Model - 6 BT - 5.9 - G1 BI01010001010000000000000515BI0100001113 2 JOb
7 7 FIRE EXTINGUISHERS BI01010001010000000000000515BI0100001112
8 8 Repair / servicing of Fire Extinguishers consisting:- 48 JOb
9 9 i) Opening, Cleaning, treating of Fire Extinguisher & Cartridge\nii) Opening, Cleaning, Treating of hose\niii) Weight checking of cartidge & Extinguisher\niv) Reassembling back after replacing New Refiling cartridge & defective hose \nv) Testing fire exitinguisher in presence of users rep (wherever applicable) \nvi) Refixing the fire extinguisher after weight checking, metalic sealing (old or new wherever replacement required) Fixing sticker of showing details of refiling on, refilling due date HPT on HPT due date (where applicable) BI01010001010000000000000515BI0100001112
10 10 FIRE EXTINGUISHERS (SPARES) BI01010001010000000000000515BI0100001112
11 11 i) Discharge hose with horn BI01010001010000000000000515BI0100001124 12 Each
12 12 ii) Refilling new cartidge Mechnical foam type Ltr capacity BI01010001010000000000000515BI0100001124 4 Each
13 13 iii) Refilling / Cartridge DCP 9 Kg capacity BI01010001010000000000000515BI0100001124 7 Each
14 14 iv) Refilling / Cartridge DCP 6 Kg Capacity BI01010001010000000000000515BI0100001124 2 Each
15 15 v) Refilling / Cartridge 2 Kg DCP Capacity BI01010001010000000000000515BI0100001125 11 Each
16 16 vi) Refilling / Cartridge Co2 Type 4.5 Kg Capacity BI01010001010000000000000515BI0100001126 12 Each
17 17 HT CABLE WORK BI01010001010000000000000515BI0100001116
18 18 a) Pinpointing the fault (first fault) on existing aluminium armoured cable, 11 KV grade of size 3 C x 185 sqmm in a length of approx. 2000 mts with the help of vehicle mounted HT fault detection machine all as directed. BI01010001010000000000000515BI0100001117 2 Job
19 19 b) Additional faults (If any) over above item 3 (a) above BI01010001010000000000000515BI0100001125 2 Job
20 20 Excavation in trenches and taking out defective cable BI01010001010000000000000515BI0100001126 20 Cum
21 21 Supply of 11 KV XLPE grade multi core stranded aluminium conductor (E) XLPE insulated and PVC sheathed armoured cable of size 3 core 185 Sqm confirming to IS 7098 (PT 1)1988 complete as required as specified BI01010001010000000000000515BI0100001126 30 Mtr
22 22 Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. BI01010001010000000000000515BI0100001116
23 23 a) 3.5 Core, 185 Sqmm BI01010001010000000000000515BI0100001119 5 Mtr
24 24 b) 3.5 Core, 95 Sqmm BI01010001010000000000000515BI0100001121 5 Mtr
25 25 Laying of one No. of XLPE insulated and PVC sheathed power cable of 11 KV grade / 1.1 KV grade cable of following size in ground inclding Excavation, Sand cushioning, Protective covering and refilling the trench complete BI01010001010000000000000515BI0100001116
26 26 a) 11 KV 3 core 185 Sqmm BI01010001010000000000000515BI0100001123 30 Mtr
27 27 b) 3.5 Core, 185 Sqmm BI01010001010000000000000515BI0100001125 5 Mtr
28 28 c) 3.5 Core, 95 Sqmm BI01010001010000000000000515BI0100001116 5 Mtr
29 29 Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrule suitable for 3 core XLPE aluminium conductor cable of size 11 KV 185/240 Sqmm including conducting hypo test after jointing all as required 4 Set
30 30 Supply and making indoor end termination with heat shrinkable jointing kit complete with all accessories including lugs, Nut bolts suitable for 3 core XLPE aluminium conductor cable 11 KV grade of size 185 Sqmm all as required 1 Set
31 31 All as per Item No. 8 Above but outdoor type 1 Set
32 32 Straight through cable jointing kit with heat shrinkable kit with ferrules for 3 1/2 x 185 sq.mm 1.1 KV grade cable 1 Set
33 33 All as per item No. 10 above but for 3 1/2 x 95 sq.mm 1.1 KV grade cable 1 Set
34 34 Cable End Termination with Aluminium lugs for 185 sq.mm cable 4 Each
35 35 All as per item No. 12 above but for Aluminium lugs for 95 sq.mm cable 3 Each
36 36 All as per item No. 12 above but for Aluminium lugs for 50 sq.mm cable 1 Each
37 37 TRANSFORMER OIL FILTRATION & TESTING BI01010001010000000000000515BI0100001116
38 38 a) Dehydration / Filtration of Transformer oil of Installed Transformer so by circulating through Trolly mounted filteration plant till achiving die-electric strength 50 KV at the Gap of 2.5mm 6000 Ltrs
39 39 b) Conduting acidity test of Transformer oil of Installed Transformer 4 Nos
40 40 c) Supply and Replacing slilica Gel of Breather 4 Kg
41 41 d) Supply of New Insulating oil as per IS having die-electric strength not less 60 KV for topping up/Replacement 400 Ltr
42 42 SERVICING AND CALIBRATION OF VCB BI01010001010000000000000515BI0100001116
43 43 a) Serivicing / periodical maintenance of 33 KV outdoor Vaccum Circuit Breaker (VCB) by service Engineer/ Technician of OEM including servicing, calibration, setting of all types of relays. Fixed on VCB panel board all as directed and thereafter Testing & calibration at site as requird (ABB MAKE) 1 Job
44 44 b) All as per Item No. 16 (a) above but for 11 KV VCB Indoor type (SIEMENS MAKE) 7 Job
45 45 Overhauling of 33 KV oil immersed outdoor current transformer by replacing insulating oil, Gasket, bushing kit etc and thereafter testing completely by using primery injection kit all as required at site for efficient functioning of Installation 3 Job
46 46 a) All as per Item No. 17 above but for 33 KV outdoor potential transformer 3 Job
47 47 Note:- Cost of insulating oil for item 17 & 18 (a) above will be measured and paid separately under relevant Item at SI No. 15 (d) above BI01010001010000000000000515BI0100001116
48 48 b) Conducting testing of Resin cast CT by using standard primery injection kit all as required at site as per IE rule 24 Each
49 49 Overhauling / repair of LT 3Ph air circuit breaker of capacity 2000 Amps/1250 Amps/ 800 Amps as per technical guideline of OEM and testing thereafter all as required at site (SIEMENS / L&T MAKE) 13 Job
50 50 Repair / servicing of calibration of soft starter 3 ph 415 V, 162A/230 Amp all as per technical guide lines of OEM (Simens) and setting starter as per Technical parameter of pumpset all as required (SIEMENS MAKE) Job 4 Job
51 51 a) Repairs to 15 KVA UPS including replacing maintenance free batteries as required and testing thereafter for rated output all as required at site Job 1 Job
52 52 b) Repair to 6 KVA UPS including replacing PCB/Master card etc as required and Testing thereafter for rated output mentioned in OEM specification Job 1 Job
53 53 Servicing of 3 ph 50 HZ, Voltage stabilizer all as per guide line given in Technical parameter of OEM of Cap - 100 KVA /60 KVA/30 KVA/ 25KVA and testing thereafter for rated output as per design of OEM (CONSUL MAKE) 6 Job
54 54 Repair / overhauling of 3 Ph, 415 V Voltage stabilizer 100 KVA / 30 KVA capacity by replacing defective parts like relays, PCB, master card etc if required Job 3 Job
55 55 Note:- Cost of batteries / PCB/ Master card / relay etc if replaced under items 21 & 23 above will be measured and paid under spares) BI01010001010000000000000515BI0100001116
56 56 a) Repair and servicing of indoor and outdoor unit of casset Air conditioner (V.R.F) type/ split AC completely of 4 TR capacity including leake testing , Gas charging, Soldering etc all as required at site including testing thereafter. \n 32 Each
57 57 Note - Gas charging & replacement of defective parts if any will be measured and paid Separately as under :-
58 58 b) Gas charging (Refrigerant R-410) Kg 30 Kg
59 59 c) Gas charging ( Refrigerent -22 ) Kg 15 Kg
60 60 a) Servicing / Periodical maintenance of Constant Current Regulator (CCR). Single phase 240 Volt. 4 KW /440 Volt 20 KW capacity as per technical guidline of OEM & testing thereafter for rated output (MAKE - NASU) Job 4 Job
61 61 b) Repair / over hauling of CCR 4 KW 240 V / 4 KW capacity. 440 V / 20 KW capacity by OEM service engineer / Technical and testing thereafter rated output all as required at site Job 2 Job
62 62 Repair to APFC panel board (Capacitor Bank) by replacing 440 Volt 3 Ph, 25 KVAR, Heavy duty capacitor 8 Nos and contactor 440 Volt, 3 Ph, Job 1 Job
63 63 Repair to Booster charger 30 V, 15 Amp capacity by replacing rectifire, DCB all as required for rated out put Make - AMAR RAJA Job 1 Job
64 64 Note:- Cost of capacitors & other spares needs to be replaced under items 26 & 27 above will be measured & paid separately under item No. 29
65 65 Repair to Runway lighting system including replacing Isolation Transformer 5 KVA and testing system complete thereafter all as required site. Each 11 Each
66 66 Part II
67 67 Cost of spares for VCB, Relay, 11 (VCB), ACB, Split, Casset AC Spares (other than Gas charging), CCR, UPS, Batteries for UPS, Replacing PCB, Master card, voltage stabilizer, APFC panel board & Booster charger etc as required L.S
68 68 Credit- for old retrieved items :-
69 69 a) Old Engine oil ( from DG set) BI01010001010000000000000515BI0100001116 170 Ltr
70 70 b) Old Transformer oil ( from CT) BI01010001010000000000000515BI0100001116 260 Ltr
71 71 c) Unservicable cable 11000 V grade BI01010001010000000000000515BI0100001116 20 Rm
72 72 d) Unserviable cable jointing kit & cable HT BI01010001010000000000000515BI0100001116 3 Each
73 73 e ) Unserviciable batteries BI01010001010000000000000515BI0100001116 36 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail