Provision Of 01 Living Barrack For Ors Near Bldg No T 485 And Spl Repair To Bldg No Opt 122 Of 234 Transit Camp Under Ge Gangtok, Gangtok-Sikkim

Military Engineer Services-MES has published Provision Of 01 Living Barrack For Ors Near Bldg No T 485 And Spl Repair To Bldg No Opt 122 Of 234 Transit Camp Under Ge Gangtok. Submission Date for this Tender is 14-10-2020. Building Repair Tenders in Gangtok Sikkim. Bidders can get complete Tender details and download the document.




Tender Notice

25558620
Provision Of 01 Living Barrack For Ors Near Bldg No T 485 And Spl Repair To Bldg No Opt 122 Of 234 Transit Camp Under Ge Gangtok
Open Tender
Indian
Sikkim
Gangtok
14-10-2020

Tender Details

Provision Of 01 Living Barrack For Ors Near Bldg No T 485 And Spl Repair To Bldg No Opt 122 Of 234 Transit Camp Under Ge Gangtok

Key Value

Document Fees
INR 500 /-
EMD
INR 53500.0 /-
Tender Value
INR 26.70 Lakhs /-

BOQ Items

Name of Work: PROVN OF 01 X LIVING BARRACK FOR ORs NEAR BLDG NO. T-485 AND SPL REPAIRS TO BLDG NO. OPT-122 OF 234 TRANSIT CAMP UNDER GE GANGTOK
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART-I (B/R WORKS) BI01010001010000000000000515BI0100001113
2 2 Rough excavation in hard/dense soil not exc.1.5 metre in depth and getting out complete all as specified and as directed by the Engr-in- Charge. BI01010001010000000000000515BI0100001114 20 CUM
3 3 Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc.1.5 metre in depth and getting out complete all as specified and as directerd by the Engr-in-Charge. BI01010001010000000000000515BI0100001115 25 CUM
4 4 M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete all as specified and as directed. BI01010001010000000000000515BI0100001116 6 CUM
5 5 Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4) including brought upto course complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001117 13 CUM
6 6 Material and labour for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregrate) as in coping including weathering slightly rounded or chamfered angels and throating complete including necessary formwork all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001118 1 CUM
7 7 M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc.rough finish surface of concrete flat all as specified and directed by the Engineer-in-Charge. BI01010001010000000000000515BI0100001119 40 SQM
8 8 M&L for RCC M-25 (design mix)using 20mm graded stone aggregate as in foundations, including rafts,footings, foundation beams; plinth beams; bases for columns,etc ; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. BI01010001010000000000000515BI0100001120 2 CUM
9 9 Material and labour for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & as directed. BI01010001010000000000000515BI0100001121 250 KG
10 10 Material & labour for mild steel TMT bars 6mm to 8mm dia as in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & as directed. BI01010001010000000000000515BI0100001122 120 KG
11 11 Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soil, complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001123 15 CUM
12 12 Removing excavated Materials (Soils) not exc. 50 M and depositing where directed at a level not exc. 1.5 Metre above the Starting Point in Soil, complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001124 30 CUM
13 13 Labour only for spreading and leveling in layers n. exc 25cm thick selected earth obtained from excavation under floors including watering well ramming etc complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001125 10 CUM
14 14 Material and labour for 75mm thick sand filling under floors including watering and consolidation complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001126 2 CUM
15 15 M&L for 75mm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in sub-base of floor over and including 50 micron polythene film laid complete all as specified and as directed by the Engr-in-Charge BI01010001010000000000000515BI0100001127 60 SQM
16 16 Material and labour for precast cement concrete solid block masonry (1:3:6) type C1using 20 mm graded aggregate as per IS 383 exc 10 cm in width and setting in cement mortar (1:6) complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001128 10 CUM
17 17 Material and labour for RCC 1:2:4 type B0 (using 20 mm graded stone aggregrate) as in seismic bands/courses and bed plates including necessary formwork complete all as specified and as directed by the Engr-in-Charge. NOTE : Re-inforcement shall be measured and paid separately. BI01010001010000000000000515BI0100001129 0.4 CUM
18 18 M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in RCC band including necessary formwork complete all as specified and as directed. BI01010001010000000000000515BI0100001130 0.5 CUM
19 19 Material and labour for 12mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut,exc 15cm and n exc 22.5cm long complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001131 10 KG
20 20 Material & labour for rendering 15mm thick on block concrete masonry walls in CM 1:6, finished even and smooth withput using extra cement complete all as specified. BI01010001010000000000000515BI0100001132 185 SQM
21 21 Material and labour for 2nd class hardwood scantling fixed clean sawn incluidng treating with raw linseed oil complete all as specified by the Engr-in-Charge. BI01010001010000000000000515BI0100001133 1.8 CUM
22 22 Material and labour for 2nd class hardwood scantling framed & fixed clean sawn incluidng treating with raw linseed oil complete all as specified by the Engr-in-Charge. BI01010001010000000000000515BI0100001134 0.8 CUM
23 23 Supply & fix Second class hard wood,plain,solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified by the Engr-in-Charge. BI01010001010000000000000515BI0100001135 0.4 CUM
24 24 Supply & fix MS flat iron as in brands,straps,supports or stays for hold fasts, clamps for eaves board/facia etc, conforming to Fe-290 Gde-E-165 complete all as specified and as directed. BI01010001010000000000000515BI0100001136 25 KG
25 25 Supply and fix 0.50mm thick pre-painted galvalume aluminimum zinc coating GI based corrugated steel sheets of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001137 80 SQM
26 26 Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley,eaves,etc and fixed with self tapping screws complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001138 10 SQM
27 27 Supply and fixing 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts as in roofs walls etc,(Class VIII) all as specified and directed. BI01010001010000000000000515BI0100001139 215 SQM
28 28 Material and labour for 6 mm thick plywood,5 ply, grade BWR type BB fixed with nails to timber frame work in Wall/Ceiling complete all as specified and as directed. BI01010001010000000000000515BI0100001140 191 SQM
29 29 Material & labor for non skid coloured ceramic tiles of 7 to 8mm thick ( Square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floors etc conforming to IS-13712, grade B-II-(a) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including cement screed bed/bedding layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed. BI01010001010000000000000515BI0100001141 58 SQM
30 30 All as per item No 29 here-in-before but as in skirting/dado over and including 10mm thick rendering in CM 1:4 backing layer complete all as specified and as directed. BI01010001010000000000000515BI0100001142 7 SQM
31 31 Materials and labour for glazed ceramic tiles coloured of size 300 x 200mm x 7 mm thick fixed on vertical surfaces such as dado etc conforming to IS - 13712 grade IB-III set jointed in neat cement slurry and pointed in white or coloured cement to match including provision of back coat of 10mm thick in cement mortar 1:4 complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001143 27 SQM
32 32 Supply & fix 25mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkats complete all as specified and directed by the Engr-in-Charge. NOTE : All builder's hardware shall be measured and paid separately. BI01010001010000000000000515BI0100001144 3.6 SQM
33 33 S&F 30mm thick (style thickness) factory made solid panel PVC door shutter consisting of frame made out of mild steel tubes for top and bottom rails, solid steel frame shall be covered with heat moulded single side prelaminated PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail on either side & as gap insert for top rail and bottom rail, paneling of both side prelaminated PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and drawing given on MES schedule Part-II(2010), page No. 156 complete all as specified and as directed. BI01010001010000000000000515BI0100001145 1.45 SQM
34 34 S&F of factory made solid PVC door frame of size 50mm x47mm made out of 5mm thick single side prelaminated PVC sheet reinforced with mild steel square tube and edges will be painted to match with single side prelaminated sheet as per specification and drawing given on Sl page No.160 of MES schedule Part-II (2010) complete all as specified and as directed. BI01010001010000000000000515BI0100001146 4.5 RM
35 35 S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or fixed with beads, in square n.exc 0.5 Sqm in each pane complete all as specified and as directed. BI01010001010000000000000515BI0100001147 2 SQM
36 36 S&F 100mm long butt hinges, medium weight, cold rolled, mild steel complete all as specified and as directed. BI01010001010000000000000515BI0100001148 6 EACH
37 37 S&F 75mm long butt hinges, medium weight, cold rolled, mild steel complete all as specified and as directed. BI01010001010000000000000515BI0100001149 3 EACH
38 38 S&F 200mm long aluminium anodised barrel tower bolt of extruded section complete all as specfied and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001150 4 EACH
39 39 S&F 100mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001151 2 EACH
40 40 S&F 250mm long aluminium anodised sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed. BI01010001010000000000000515BI0100001152 2 EACH
41 41 S&F 150mm long aluminium anodised handles, cast type, complete all as specified and as directed. BI01010001010000000000000515BI0100001153 4 EACH
42 42 S&F 125mm long aluminium anodised handles, cast type, complete all as specified and as directed. BI01010001010000000000000515BI0100001154 2 EACH
43 43 S&F 140mm floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring complete all as specified and as directed by the Engr-in-Charge BI01010001010000000000000515BI0100001155 2 EACH
44 44 S&F in repairs powder coated aluminium two track sliding windows of heavy grade frame & shutters sections of appropriate sizes including all fittings and fixtures required with rubber gasket, handle, locking arrangement etc of Jindal Make all as shown of typical drawings, specified & directed by Engr-in-Charge. Make : Jindal or equivalent approved. BI01010001010000000000000515BI0100001156 40 KILOGRAM
45 45 S&F in repairs 5.5mm (tinted) float glass, for two track aluminium sliding windows side hung doors complete all as shown on drawings specified and as directed. 8 SQM
46 46 S&F galvanised steel water tubing 15mm bore, medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed by the Engr-in-Charge BI01010001010000000000000515BI0100001157 30 RM
47 47 Supply and fixing in repair star white vitreous china wash down water closet pan (pedestal pattern) EWC, of size 570x460x380 mm with 'P' or 'S' trap, including fixing bolts, Plastic water closet seat and cover, closed pattern with flat bottom, and mild steel chromium plated or aluminised hinging device, making all necessary connections and making good disturbed surfaces of floor complete all as specified and as directed. Make : Cera Cat No. S1050106 S trap Cat No. B1510120 Ceraanglo deluxe seat cover or equivalent approved. BI01010001010000000000000515BI0100001158 1 EACH
48 48 S&F 10 litre capacity low level PVC flushing cistern(white), syphonic action type, with inlet, ball valve, float, handle, fixed with cst iron bracket (of suitable size) and providing 32mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed. Make : Cera Cat No. B1010101 or equivalent approved. BI01010001010000000000000515BI0100001159 1 EACH
49 49 M&L for vitreous china wash basin with full pedestal, white, including waste coupling and pipe, brackets complete all as specified and directed by the Engr-in-Charge. Make : Code : FLS-WHT-0605 and Code FLS-WHT-1502 for pedestal of Jaquar or equivalent. BI01010001010000000000000515BI0100001160 1 EACH
50 50 Supply and fixed 15mm bore pillar taps, fancy type with long neck with aerator cast copper alloy with capstan head, chromium plated, screwed down, high pressure with long screwed shanks, fly-nuts, with screwed for GI pipe complete all as specified and as directed. Make : JAQUAR Code CON-CHR-021 KN or equivalent approved. BI01010001010000000000000515BI0100001161 1 EACH
51 51 S&F wall mounted hot and cold water mixer with connecting lugs and wall flanges, cast copper alloy, chromium plated complete all as specified and as directed. Make : Jaquar Continental Series Cat No. SOL-CHR-6119 or equivalent approved. BI01010001010000000000000515BI0100001162 1 EACH
52 52 S&F 15mm bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make : Jaquar Continental Series Cat no. 037 KN or equivalent approved. BI01010001010000000000000515BI0100001163 1 EACH
53 53 S&F angular stop cock made of brass chromium plated screwed both ends for iron pipe for 15mm bore complete all as directed by the Engr-in-Charge. Make : ESSCO Cat Part No. DLX-ESS 526 or equivalent approved. BI01010001010000000000000515BI0100001164 5 EACH
54 54 S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as directed by the Engr-in-Charge. Make : Prayag Cat No. 323 or equivalent approved. BI01010001010000000000000515BI0100001165 5 EACH
55 55 S&F brass chromium plated shower rose 120mm size complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat No. OHS-1789 or equivalent approved. BI01010001010000000000000515BI0100001166 1 EACH
56 56 S&F 5.5mm thick looking mirror bevelled edge, mounted on walls and fixed to wooden plugs with chromium plated brass screws and cup washers including back packing with 4mm thick plywood (BWR type) all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001167 1.5 SQM
57 57 S&F 75mm bore PVC (SWR) plain floor trap with CP grating complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001168 1 EACH
58 58 S&F PVC(SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints fixed to wall complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001169 21 RM
59 59 S&F 75mm bore PVC(SWR) bends and radius complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001170 9 EACH
60 60 S&F PVC (SWR) pipes 110mm dia, single socketed, in any length with rubber ring joints fixed to wall complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001171 10 RM
61 61 S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001172 2 EACH
62 62 S&F 110mm bore PVC (SWR) equal or unequal junction single (Single T) complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001173 1 EACH
63 63 S&F 75mm bore PVC (SWR) equal or unequal junction single (Single T) complete all as specified and as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001174 3 EACH
64 64 S&F 110mm bore PVC (SWR) vent cowl complete all as specified and as directed. BI01010001010000000000000515BI0100001175 1 EACH
65 65 S&F in repairs CP tubular towel rail 600mm long with and including chromium plated brass screws complete all as specified and as directed. Make : JAQUAR 'Continental Series' Cat No. 1111 or equivalent of approved make. BI01010001010000000000000515BI0100001176 2 EACH
66 66 S & F in repair CP Soap dish complete all as specified and as directed ( Make : JAQUAR Code : ACN-1131N or equivalent approved.) BI01010001010000000000000515BI0100001177 2 EACH
67 67 S&F hand shower (health faucet) alongwith 1m flexible tube. Make :- For Hand Shower, JAQUAR code-ALD-573 or equivalent approved BI01010001010000000000000515BI0100001178 1 EACH
68 68 S&F of glass shelf 600mm long assembly with CP bracket, fixed to plugs with brass screws on wall complete all as specified and as directed. Make : Jaquar Cat No. AKB-35771 or equivalent approved. BI01010001010000000000000515BI0100001179 1 EACH
69 69 S&F in repaired aluminium powder coated fancy curtain rails plain or colour 25mm dia as approved with teak wood finishing brackets and knobs complete all as specified and as directed. BI01010001010000000000000515BI0100001180 25 RM
70 70 M&L for RCC M-25(Design Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, cover slabs etc complete all as specified and as directed by the Engr-in-Charge. NOTE : Re-inforcement shall be measured and paid separately. BI01010001010000000000000515BI0100001181 1 CUM
71 71 Material and labour for hardcore of guage n.exc.63mm ( using broken stone or boulders) deposited, spread and levelled in layers not exc.15cm thick, watered and rolled/rammed to a true surface complete all as directed. BI01010001010000000000000515BI0100001182 1 CUM
72 72 M&L for 75mm thick PCC (1:3:6), type C-2 ( using 40 mm graded stone aggregate ) as in plinth protection; path / hardstanding etc laid in bays / panels not exc.2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified and as directed. BI01010001010000000000000515BI0100001183 30 SQM
73 73 Material and labour for applying two coats of anti corrosive paint (red/green colour) over a coat of red oxide primer on new or previously untreated zinc or galvanised steel surfaces over 10 cm width or girth on roof covering, after necessary preparation of surfaces by applying mordant solution and cleaning, washing etc complete all as specified and as directed. BI01010001010000000000000515BI0100001184 45 SQM
74 74 M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistance primer on new surfaces of walls all as specified and as directed. BI01010001010000000000000515BI0100001185 40 SQM
75 75 Materials and labour for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of chalk whiting primer complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001186 145 SQM
76 76 Materials and labour for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer completed all as specified and as directed. BI01010001010000000000000515BI0100001187 155 SQM
77 77 Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area n.exc 1.5 sqm complete all as specified and as directed. BI01010001010000000000000515BI0100001188 6 EACH
78 78 Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm all as specified and as directed. BI01010001010000000000000515BI0100001189 1 EACH
79 79 Hacking out old broken glass ( any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and removal from the site complete all as directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001190 1.5 SQM
80 80 S&F 3mm thick sheet glass panes, ordinary quality and glazing with oil putty including steel pin in square n.exc 0.5sq.m in each pane fixed to steel frame complete all as specified & as directed. BI01010001010000000000000515BI0100001191 1.5 SQM
81 81 S&F in repair galvanised mild steel wire mesh 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified. BI01010001010000000000000515BI0100001192 1.5 SQM
82 82 S&F aluminium powder coated door side hung type heavy duty Jindal sections frame & shutters of appropriate sizes including jointing cleats, glazing clips, aluminium snap bidding, rubber neoprene gasket packing handles, tower bolts and all other fittings as required etc complete all as shown on drawings & as specified and directed. (Make: Jindal or equivalent approved)\n\n BI01010001010000000000000515BI0100001193 20 KILOGRAM
83 83 Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed. BI01010001010000000000000515BI0100001194 2.8 QUINTAL
84 84 S&F mild steel tubular trusses including special shaped washer etc. Complete using ERW or induction butt wekded tubes conforming to IS-1161-1998 grade St-240 including one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication and fixing complete all as specified and as directed. BI01010001010000000000000515BI0100001195 280 KG
85 85 M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces exc 10cm width or girth over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed. BI01010001010000000000000515BI0100001196 10 SQM
86 86 Taking down cement plaster of any description on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001197 15 SQM
87 87 Material and labour for applying three coats of white washing including preparation of new / previously untreated surfaces of wall complete all as specified and as directed. BI01010001010000000000000515BI0100001198 15 SQM
88 88 Dismantling old PGI/CGI sheeting any gauge, thickness including Nainital. Sikkim or similar pattern roof/facia including ridge etc and keeping serviceable sheets in safe custody for re-use complete all as directed. BI01010001010000000000000515BI0100001199 320 SQM
89 89 Supply and fixing 0.63mm thick plain, galvanised, mild steel sheeting, with 275 grams per sqm zinc coating as in ridges, hips, valley gutters, drip & straight flashing etc complete all as specified and directed. BI01010001010000000000000515BI0100001200 10 SQM
90 90 All as per item No 89 here-in-before but except sheeting. BI01010001010000000000000515BI0100001201 135 SQM
91 91 Material and labour for applying two coat of anti-corrosive coptic green paint on old treated roof/wall surfaces of CGI/PGI sheeting of any description and in any position over 10cm width or girth including necessary preparation of surfaces complete all as specified and as directed. BI01010001010000000000000515BI0100001202 209.5 SQM
92 92 Material and labour for applying one coat of anti-corrosive coptic green paint on old treated roof/wall surfaces of CGI/PGI sheeting of any description and in any position over 10cm width or girth including necessary preparation of surfaces complete all as specified and as directed. BI01010001010000000000000515BI0100001203 153.9 SQM
93 93 Dismantling of wall and ceiling board (fibre pulp, insulation etc) /AC sheets and plywood any thickness and cover fillets and removal of dismantled materials/rubbish from site complete all as specified and directed. BI01010001010000000000000515BI0100001204 191 SQM
94 94 Supply and fix 4mm thick Non asbestos fibre cement building boards (E-board) of approved texture, for insulation and acoustic purpose of size 595 x 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surfaces and applying two coats of oil emulsion distemper over a coat of primer including preparation of surfaces complete all as per manufacturers instruction & specified and directed by the Engr-in-Charge. BI01010001010000000000000515BI0100001205 120 SQM
95 95 S& F for GI Powder coated snap grid frame work for false ceiling of 605 x 605m size fixed to walls with rawl plugs & screws and hanged to roof with including 1mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 23mm x 28m x 0.70mm thick, cross tee shall be 23m x 28mm x 0.70mm thick and wall angle shall be 20mm x 20mm x 0.70mm thick confirming IS:733, 737 & IS:1285 ; complete all as per manufacturer's instructions specified and as directed. BI01010001010000000000000515BI0100001206 120 SQM
96 96 Material and labour for 2nd class hard wood fillets,square, rectangular and triangular in section, wrought, secured with nails, sectional area exe 3 Sqcm but n.exc 6 Sqcm in section complete all as specified and as directed. BI01010001010000000000000515BI0100001207 200 RM
97 97 Dismantling of timber in scantling 40 sqcm and over in section in any position in unframed work all as specified. BI01010001010000000000000515BI0100001208 1 CUM
98 98 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & as directed. BI01010001010000000000000515BI0100001209 135 SQM
99 99 M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing & incl 15mm thick screed bed CM 1:6 complete all as specified & directed BI01010001010000000000000515BI0100001210 125 SQM
100 100 M&L for lacquer coated chequered cement concrete tiles 20cm x 20cm x 25mm/ 30cm x 30cm x 25mm thick, set jointed and pointed in neat cement slurry in floors with grey cement and pigments over and incl 15mm thick screed bed or bedding layer of in CM 1:6 all as specified. BI01010001010000000000000515BI0100001211 10 SQM
101 101 Demolition of brickwork or stone/boulder masonary built in cement mortar including all quions, arches, pillars, precast PCC bond stones including separating serviceable stones/boulders & setting aside for reuse in the work and removal of unserviceable materials from site complete all as specified and directed. BI01010001010000000000000515BI0100001212 1 CUM
102 102 Demolition of precast block masonary or precast concrete article built in cement mortar and removal or unserviceable materials from site complete all as specified and directed. BI01010001010000000000000515BI0100001213 9 CUM
103 103 M&L for Precast cement concrete hollow block masonary(1:3:6) type C1 (using 20mm graded aggregate) exc.10cm in width and setting in 1:6 cement mortar as per IS-383) complete all as specified and directed. BI01010001010000000000000515BI0100001214 9 CUM
104 104 Demolition to cement concrete of any description and in any position not otherwise specifically provided for (unreinforced) complete al as specified and directed. BI01010001010000000000000515BI0100001215 1 CUM
105 105 Material and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channels and drains including necessary formwork & forming fair finish to drain channel complete all as specified and as directed. BI01010001010000000000000515BI0100001216 1 CUM
106 106 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form, moulds,mitrred/stopped ends complete all as specified and as directed. BI01010001010000000000000515BI0100001217 10 RM
107 107 Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. BI01010001010000000000000515BI0100001218 1.5 CUM
108 108 Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc. Including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete. BI01010001010000000000000515BI0100001219 21 RM
109 109 S&F PVC (SWR) half round 150mm dia with rounded edges incl all accessories like bend T etc for eaves gutter complete all as specified and directed. (Make:PRINCE or equivalent approved) BI01010001010000000000000515BI0100001220 15 RM
110 110 Supply & fix in repair 150 mm bore PVC (SWR) pipes single sockete, in any length with rubber ring joints fixed to wall with necessary clamps, bolts etc complete all as specified and as directed. (Make: PRINCE or equivalent approved). BI01010001010000000000000515BI0100001221 6 RM
111 111 Supply & fix in repair 150 mm bore PVC (SWR) bends any radius complete all as specified and directed by the Engr-in-Charge. (Make:PRINCE or equivalent approved). BI01010001010000000000000515BI0100001222 2 EACH
112 112 SCHEDULE 'A' PART-II (E/M WORKS) BI01010001010000000000000515BI0100001223
113 113 M & L for point wiring with 1.5 Sqmm (nominal cross- sectional area) PVC (FRLS) insulated uncheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor in including PVC heavy grade rigid non metallic 25 mm PVC casing caping (double Lock) including PVC polycarbonate/PVC/reactangular block /box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross sectional area PVC (FRLS) insulated unsheathed single core multistranded copper conduct cable as earth continuity conductor connected to main switches/DBs or common earth dolly complete all as specified and directed for the following :-\n Make of cable-Havells/Finolex/plaza, Make of Casing caping- Prestoplast/Plaza/Modi BI01010001010000000000000515BI0100001224
114 114 (a) All as per item No. 113 above but one light point/fan controlled by one switch. BI01010001010000000000000515BI0100001225 55 POINT
115 115 (b) All as per item No. 113 above but one 5 pin 5 Amps switch socket point controlled by one switch with 1.5 Sqmm FRLS copper cable on independent board BI01010001010000000000000515BI0100001226 14 POINT
116 116 (c) All as per item No. 113 above but with 2.5 Sqmm FRLS wire for 16 Amps power point on independent board BI01010001010000000000000515BI0100001227 29 POINT
117 117 Supply and fixing Decorative LED tube light fittings 4' long 20 watt with fixture electronic driver complete with connection. Make : C&S cat No Tara E/20W or equivalent approved. BI01010001010000000000000515BI0100001228 37 EACH
118 118 Supply and fix in repairs of lamp holder, angular/straight insulated body with back plate PVC / Polycarbonate type with grid cap suitable for batten fittings white/ivory finish and fixing of 20/18 watt CFL complete all as specified and as directed. Make : Anchor Product Code No. 39527 or equivalent approved. BI01010001010000000000000515BI0100001229 13 EACH
119 119 M&L for Exhaust fan 200mm sweep,250 V,AC 50 Hz PVC heavy duty including cutting bricks/stones boulders wall or fixing of fan and finished the cutting surface even and smootrh by using cement mortar complete all as specified and directed ( Make Havells cat no Ventil air DX (FHVVEDXOWH08) or equivalent approved) BI01010001010000000000000515BI0100001230 1 EACH
120 120 S&F in repairs switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and as directed.\nMake : Anchor Product Code No. 50053 or equivalent approved. BI01010001010000000000000515BI0100001231 55 EACH
121 121 S&F in repairs switch socket combination, 2 and 3 pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as specified and as directed. Make : product Code No. 4056/50483 or equivalent approved. BI01010001010000000000000515BI0100001232 14 EACH
122 122 S&F in repairs switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as specified and as directed. Make : Anchor Cat no. 38808/50665 or equivalent approved. BI01010001010000000000000515BI0100001233 29 EACH
123 123 S&F in repairs ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed\nMake : Anchor Product Code No 39040 or equivalent of approved BI01010001010000000000000515BI0100001234 37 EACH
124 124 M&L in repairs for SPN 8 way, DB for MCB SPN as incomer and SP MCB as outgoing with IP 43 and IK 09 protection complete with fixing in wall and making good disturbed surfaces and connection.Note:- MCB are not included in the item rate and considered separately. Make:- Legrand, model-EKINOXE,Cat No-607711 or equivalent approved. BI01010001010000000000000515BI0100001235 1 EACH
125 125 S&F in repairs MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. \n(Make : L&T cat No BB10060C to BB10320C or equivalent approved) BI01010001010000000000000515BI0100001236 18 EACH
126 126 Supply and fix in repairs of MCB SPN 240 volt 6 to 32 Amp 'C' curve including dismantling and taking down old one complete all as specified and as directed. (Make : L&T cat No BB20060C to BB20320C or equivalent approved) BI01010001010000000000000515BI0100001237 3 EACH
127 127 Supply & fix in repairs of single door 4 way,DB for MCB TPN as incomer and SP MCB as outgoing with IP 43 and IK 09 protection complete with 200 Amps rated bus fixing in wall and making good disturbed surfaces and connection. Note: - MCB are not included in the item rate and considered separately. Make:- Legrand, model-EKINOXE,Cat No- 607711 or equivalent approved. BI01010001010000000000000515BI0100001238 2 EACH
128 128 M&L in repairs for sub main wiring with 2 run of 6 sqmm PVC insulated unsheathed single core cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable (FRLS) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn in and including PVC heavy grade suitable size rigid non-metallic casing capping complete all as specified and as directed.Note:- Two run of sub main wiring cable along with one run of earth wire shall be measured as one length. (Make:- Havells / Polycab / FINOLEX or equivalent approved) BI01010001010000000000000515BI0100001239 32 RM
129 129 Supply and fixing of water proof 10 Watt LED bulk head. Make:Crompton Cat No-LBHP-10-CDL OR equivalent approved. BI01010001010000000000000515BI0100001240 4 EACH
130 130 M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the earth plate not less than 1.5M below ground level connected to galvanised earth lead wire 4.0mm dia by means of nuts,bolt,washers etc of copper / brass connected to earth test point complete all as specified in electrical plate No-3 of SSR(2009) part 1, including mecessary excavation and earth work in any strata of soil,GI light grade water pipe with 20mm dia, funnel & wire mesh PCC (1:3:6) type C1 pit with CI cover and frame etc all as specified and directed by Engineer-in-Charge. Note:- All the joints shall be made with welding to get proper conductivity. BI01010001010000000000000515BI0100001241 2 EACH
131 131 M&L for fixing of TPN 4 way, double door DB with MCB SPN as incomer and SP MCB as outgoing with IP-43 and IK 09 protection complete with fixing in wall and making good disturbed surfaces and connection. Note :- MCB are not included in the item rate and considered separately. Make :- Legrand, Model-EKINOXE, Cat No- 607711 or equivalent approved including dismantling and taking down old one. 1 EACH
132 132 Supply & fix in replacement Rotational moulded polyethylene water storage tank 1000 litres capacity, ISI marked three layer constriction (cylindrical vertical with closed top), hoisted & fixed in position including supply and fixing of 25mm bore Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe of having weight not less than 455 gms including connection complete all as specified and as directed including dismantling of old unserviceable water tank. \nMake of Water Tank : SINTEX or equivalent approved make as specified.\nMake of Ball Valve : Prayag or equivalent approved make as specified. BI01010001010000000000000515BI0100001242 1 EACH
133 133 S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe of 25mm bore of having weight not less than 455 gms complete all as specified and as directed. BI01010001010000000000000515BI0100001243 1 EACH
134 134 Supply, install, testing and commissioning 25 Ltrs capacity energy efficient geysers vertical type ISI marked 240 volts, 50 Hz with inner stainless steel container, outer MS sheet enclosures with glass wool insulation lining between inner SS container and outer enclosure including necessary fixtures fixed with 4 Nos 16mm dia, 150mm long MS bolts, nuts with washers necessary drilling holes to walls fixed with wooden plugs and grouted in wall with cement mortar (1:3) marking good the disturbed surfaces of walls with and including safety valve, non return valve of 15mm bore ISI marked with two number 10mm dia 300mm long PVC flexible connection with chromium plated brass union one on each side for making flexible connection to geysers etc complete all as specified and as directed. Make : Havells GHWAMGTWH025 or equivalent approved. BI01010001010000000000000515BI0100001244 1 EACH
135 135 Material and labour for GI pipe galvanized medium grade with all fittings like socket,elbow,bends,union etc ends laid in trenches/floor or fixed with wall of size 25mm bore of pipes. BI01010001010000000000000515BI0100001245 50 RM
136 136 S & F Gun Metal gate valve 25mm with iron wheel head screwed both ends for iron piped fixed. All as specified. BI01010001010000000000000515BI0100001246 1 Each
137 137 Supply, laying, jointing & testing 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured LT electric power cables, heavy duty with aluminium conductor of cress sectional area 25 Sqmm 3.5 core with all fixing & connecting accessories as in service connection complete all as specified and as directed including taking down old unserviceable one. \n\nNote : The rate quoted by the bidder shall be deemed to be inclusive of cost of aluminium thimbels/lugs of suitable size. BI01010001010000000000000515BI0100001247 80 RM
138 138 Taking down carefully old aluminium point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and keeping aside as directed. BI01010001010000000000000515BI0100001248 49 Per Point
139 139 Dismantling of main switch board of sheet metal wooden etc including main switch,MCB DB, change over with MCB/MCCBs etc complete for replacement or reuse all as specified and as directed. BI01010001010000000000000515BI0100001249 2 EACH
140 140 Dismantling of unserviceable light fittings of any description and keeping aside for replacement or reuse. BI01010001010000000000000515BI0100001250 25 EACH
141 141 M&L in repairs for SPN 12 way, double door DB with MCB SPN as incomer and SP MCB as outgoing with IP 43 and IK 09 protection complete with fixing in wall and making good disturbed surfaces and connection. Note: Legrand, model-EKINOXE,Cat No-607711 or equivalent approved. BI01010001010000000000000515BI0100001251 1 EACH
142 142 Supply and fix in repairs of MCB TPN 415 volt 6 to 32 Amp ''C'' curve complete all as specified and as directed. (Make : L&T Cat No. BB30060B to BB30320B or equivalent approved. BI01010001010000000000000515BI0100001252 1 EACH
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy