Periodical Services To Certain Bldgs At 28 Amn Coy Chakkigam And Repair To Wall Fencing Gate Drain And Other Misc B R Works And Desludging Cleaning And Repair To Sewage Line Soakage Well And Spectic Tank In The Area Of Age B R-I Under Ge 874 Ews, chakigam and zangli-Jammu And Kashmir

Military Engineer Services-MES has published Periodical Services To Certain Bldgs At 28 Amn Coy Chakkigam And Repair To Wall Fencing Gate Drain And Other Misc B R Works And Desludging Cleaning And Repair To Sewage Line Soakage Well And Spectic Tank In The Area Of Age B R-I Under Ge 874 Ews. Submission Date for this Tender is 12-10-2020. Building Work Tenders in chakigam and zangli Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25513200
Periodical Services To Certain Bldgs At 28 Amn Coy Chakkigam And Repair To Wall Fencing Gate Drain And Other Misc B R Works And Desludging Cleaning And Repair To Sewage Line Soakage Well And Spectic Tank In The Area Of Age B R-I Under Ge 874 Ews
National Competitive Bid
Indian
Jammu And Kashmir
chakigam and zangli
12-10-2020

Tender Details

Periodical Services To Certain Bldgs At 28 Amn Coy Chakkigam And Repair To Wall Fencing Gate Drain And Other Misc B R Works And Desludging Cleaning And Repair To Sewage Line Soakage Well And Spectic Tank In The Area Of Age B R-I Under Ge 874 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PERIODICAL SERVICES TO CERTAIN BLDGS AT 28 AMN COY CHAKKIGAM AND REPAIR TO WALL FENCING, GATE, DRAIN & OTHER MISC B/R WORKS AND DESLUDGING, CLEANING AND REPAIR TO SEWAGE LINE, SOAKAGE WELL AND SPECTIC TANK IN THE AREA OF AGE B/R-I UNDER GE 874 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantalling of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. 35 Cum
2 2 Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, man holes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil, complete all as specified and directed. 35 Cum
3 3 Demolition of cement Concrete in ground floors and pavings(Un-reinforced) n exc 15 cm thickness (below or above ground level, complete all as specified and as directed. 4 Cum
4 4 Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), complete all as specified and as directed. 4 Cum
5 5 Dismantling posts or struts (Wood, Steel or R.C.C.) any section, embedded in cement concrete or brick masonry work, including taking out embedded portion and making good disturbed ground, complete all as specified and directed by Engineer-In-Charge. 70 Per RM
6 6 Dismantling fencing wire mesh/chain link fencing including MS mesh, any type complete all as specified 150 Sqm
7 7 Brick work with sub class ‘B’ modular bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified & directed. 24 Cum
8 8 Description all as per item No. 07 above, but except brick, complete all as specified and directed. 3 Cum
9 9 Walling of random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4), complete all as specified. 8 Cum
10 10 Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed 28 Cum
11 11 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed. 7 Cum
12 12 Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified. 2.5 Cum
13 13 Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified. 6.5 Cum
14 14 RCC nominal mix 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in beams, cantilevers, bressummers, lintel over 1.5 mtr span, complete all as specified. 1.5 Cum
15 15 Mild steel work as in hand rails, half round or other stock section or core for wooden hand -rail, straight portion drilled and countrsunk for ballusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-250 Gde E-165 all as specified. 300 Kgs
16 16 Fixing only Mild steel work as in hand rails, half round or other stock section or core for wooden hand -rail, straight portion drilled and countrsunk for ballusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work, all as specified. 150 Kgs
17 17 S & F Framed work such as grills, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors , ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290, Gde- E - 165, complete all as specified. 100 Kgs
18 18 PCC 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in coping, lintel band, string coarse etc incl necessary formwork, weathering, slightly rounded or chamfered angles and throating as directed. 5 Cum
19 19 Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc on flat rough finished surface of concrete complete all as specified & directed. 5 Sqm
20 20 Supply and fixing TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified. 300 Kgs
21 21 TMT bars, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified 90 Kgs
22 22 Galvanised, 2-strand, steel barbed wire 2.24mm dia barbed with 2.0 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), fixed in repairs, complete all as specified and as directed by Engineer-In-Charge. 10 100 RM
23 23 Applying two coats of synthetic enamel paint over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed. 25 Sqm
24 24 M/L preparing old steel surfaces including roof surfaces and applying one coat of synthetic enamel paint (1st grade quality) on steel surfaces, not otherwise described over 10cm width or girth, complete, all as specified and directed. 322 Sqm
25 25 Supply only 0.90mm dia mild steel soft drawn binding or tying wire, annealed, complete all as specified. 20 Kgs
26 26 Taking down cement plaster on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified. 360 Sqm
27 27 M & L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), finished even and smooth (without using extra cement ), complete all as specified. 260 Sqm
28 28 15mm thick rendering in CM 1:4 on other than fair faces of bricks/stone work making surface even and smooth without using extra cement, complete all as specified. 290 Sqm
29 29 Raised pointing to random rubble or polygonal rubble, uncoarsed or brought upto courses in cement mortar 1:4, complete all as specified and directed. 5 Ten\nSqm
30 30 Two coat of Cement base paint over to new plastered surfaces of wall including preparation of surface, complete all as specified. 475 Sqm
31 31 Supply only Chain link MS galvanisd fencing, any size or type(weight n.exc 4 kg per sqm) complete all as specified. 200 Kgs
32 32 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified. 65 sqm
33 33 Flush pointing to random rubble masonary, uncoarsed or brought upto courses, in cement mortar 1:3, all as specified and directed. 3 Ten\nSqm
34 34 Boulder filling dry hand packed tightly as in vertical bunds with sloping face in the back side of retaining wall complete all as specified. 4 Cum
35 35 Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10m openable length (total length 90m) having 50 Nos rounds per 6m length upto 3.0m height fo wall with existing angle iron Y shaped placed 2.4m or 3.0 m apart and with 9 horizontal RBT reinforced barbed wire, stud tired with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron, all complete as per direction of Engineer in charge, with reinforced barbed wire tape (RBT)/spring core (2.5mm thick) wire of high tensile strength of 165 Kg/sqmm with tape (0.52mm thick and weight 43.478 gm/m (cost fo MS angle, CC blocks shall be paid separately), including taking old unserviceble, complete all as specified. 80 RM
36 36 PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint, laid in trenches, floor/walls as soil pipe(vent pipe), fixed in repair, complete all as specified and directed. 30 RM
37 37 PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint, laid in trenches, floor/walls as soil pipe, complete all as specified and directed. 55 RM
38 38 Outsourcing of manpower (2 Safaiwalas daily) to provide services of cleaning of blockages of sewage lines of any dia and depth, manholes of any size and depth, working in foul condition cleaning of manholes and sewage lines by rodding to and fro, flushing with water in sewage lines between successive manholes and keeping the system functional including water closets, floor traps, Nahani traps, gully traps etc, upto final drop/outlet into septic tanks, manually or mechanically including cleaning of soil/waste/vent pipes and rain water pipes of any description and size in the area of AGE B/R-I Grn by one Semi-Skilled Tradesman, (having minimum educational qualification of matriculation) and one helpers, in one shift of eight Hours per day (from 900 Hrs to 1700 Hours) for attending complaints of sewage cleaning as instructed by concerned JE with complaint slip and report back to the same JE, including maintaining of the record of complaint slips after getting signature of users, complete all as specified and as directed by Engineer-In-Charge. 210 Per day
39 39 Dewatering/pumping/bailing out contaminated with waste material sludge from septic tank along with inlet outlet chamber of any capacity/depth by vehicle mounted sewage suction machine and disposing same out of cantonment area including taking off manhole covers and putting back the same after cleaning/ removing the liquid waste material of septic tanks and cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces to make hygienically fit, writing the date of cleaning of septic tank with black and white paint of size 150 x 200mm and finally spraying unslaked lime (bleaching powder), dry, around and over the septic tank all as directed and to the entire satisfaction of by Engr-in-Charge. Note:- 1. Qty of liquid sludge shall be measured for payment under this item. 2. Arrangement of Land for the disposal of waste is complete responsiblity of contractor. 3. Arrangement of suction machine is responsiblity of contractor. 110 Cum
40 40 Demolition or breaking up drain pipe 100mm dia (salt glazed ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete complete all as specified. 15 RM
41 41 Demolition or breaking up drain pipe 150mm dia (salt glazed ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete complete all as specified. 20 RM
42 42 Demolition or breaking up drain pipe 200mm dia (salt glazed ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete complete all as specified. 10 RM
43 43 Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm drain pipe after they are laid with PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. (Note: - drain pipe and earthwork shall be measured and paid seperately under respective items of Sch 'A') 15 RM
44 44 Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm drain pipe after they are laid with PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. (Note: - drain pipe and earthwork shall be measured and paid seperately under respective items of Sch 'A') 20 RM
45 45 Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm drain pipe after they are laid with PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. (Note: - drain pipe and earthwork shall be measured and paid seperately under respective items of Sch 'A') 10 RM
46 46 Cutting into existing manholes for connecting new drains 150 mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified. 4 Each
47 47 110mm PVC (SWR) junction single, (single T) equal or unequal complete all as specified and directed. 6 Each
48 48 Loose filling with broken brick aggregate of gauge 80 to 150 mm in soakage wells/pits, complete all as specified. 3 Cum
49 49 High density polyethylene pipes (HDPE) of 50mm bore pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified 10 RM
50 50 M/L Precast RCC 1:1.5:3 type A1 using 20mm graded crushed stone aggregate for landing/cover slab, septic tank/soakage well/manhole cover and set in cement mortar(1:4) complete all as specified. Note:- Reinforcement will be mearsured and paid separately 3 Cum
51 51 Vitreous china squatting pan (Orissa pattern) size 580 x 450 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, fixed in repair, complete all as specified and directed. 5 Each
52 52 S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity, low level white with inlet ball valve float and handle including brackets including 32mm dia PVC. flush pipe for low level cistern including all joints, complete all as specified. 4 Each
53 53 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. 62 Sqm
54 54 Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles, over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed. 42 Sqm
55 55 Glazed ceramic coloured tiles 300x200 x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge. 20 Sqm
56 56 Vitreous china bowl urinal flat back, size of 465x355x265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws and pointing around urinal back in cement etc and 32mm dia PVC waste pipe, fixed in repair, complete all as specified. 4 Each
57 57 PVC (SWR) S trap 125/110mm bore, complete all as specified and directed. 5 Each
58 58 M&L preparing old wooden surface and applying one coat of synthetic enamel paint (1st grade quality) on wooden surfaces, not otherwise described over 10cm width or girth, complete, all as specified and directed. 40 Sqm
59 59 Preparation of old decorated plastered wall surface and applying one coat of synthetic enamel paint (1st grade quality) in camouflage pattern/single shade, not otherwise described over 10cm width or girth, complete, all as specified and directed. 45 Sqm
60 60 Preparation of old plastered/ un-plastered on wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified. 75 Sqm
61 61 Preparation of old plastered/ un-plastered in ceiling surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified. 40 Sqm
62 62 M & L for one coat of Cement base paint to old decorated surfaces of wall in camouflage pattern/single shade including preparation of surface, complete all as specified. 120 Sqm
63 63 Preparation of external old plastered/un-plastered surfaces of RCC braces, beams, columns and all concrete applying two coats of weather coat paint(With comouflage pattern/Dull green) over one coat of primer after complete removal of existing treatment complete all as specifed and directed. 1880 Sqm
64 64 Preparation of internal old plastered/un-plastered wall surfaces of any description wood, steel, iron, concrete, brick/stone work etc and applying two coats of fire resisting paint over one coat of wall putty after complete removal of existing treatment, up to 7.5m height from ground level, complete all as specified. 1820 Sqm
65 65 M&L for two coat of cement base paint to old decorated surfaces of wall in camouflage pattern/single shade incl preparation of surface & curing complete after complete removal/scarpping of existing treatment. 130 Sqm
66 66 M & L One coat of oil bound distemper on walls with 1mm wall care putty incl preparation of old surface complete all as specified and directed. 90 Sqm
67 67 M & L two coat of oil bound distemper on walls with 1mm wall care putty incl preparation of old surface complete all as specified and directed. 100 Sqm
68 68 M & L One coat of oil bound distemper in ceiling including preparation of old surface complete all as specified and directed. 40 Sqm
69 69 French polishing on old wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats, complete all as specified. 335 Sqm
70 70 Applying two coats of white wash including preparation of newly plastered surfaces of wall complete all as specified. 25 Sqm
71 71 M & L two coat of oil bound distemper on walls with 1mm wall care putty incl preparation of new plastered/unplastered surface complete all as specified and directed. 25 Sqm