Repair/Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And Misc Items At Cbs Bhalra , Mtn Bde And Ews Under Ge ( I ) 873 Ews Repair/Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And M, BHADERWAH-Jammu And Kashmir

Military Engineer Services-MES has published Repair/Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And Misc Items At Cbs Bhalra , Mtn Bde And Ews Under Ge ( I ) 873 Ews Repair/Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And M. Submission Date for this Tender is 12-10-2020. Bolts Tenders in BHADERWAH Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25512280
Repair/Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And Misc Items At Cbs Bhalra , Mtn Bde And Ews Under Ge ( I ) 873 Ews Repair/Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And M
Open Tender
Indian
Jammu And Kashmir
BHADERWAH
12-10-2020

Tender Details

Repair / Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And Misc Items At Cbs Bhalra , Mtn Bde And Ews Under Ge ( I ) 873 Ews Repair / Replacement And Maintenance Of Internal Wiring , Fittings Mcbs , Service Cable And Misc Items At Cbs Bhalra , Mtn Bde And Ews Under Ge ( I ) 873 Ews-1 Taking Out Carefully Copper / Aluminium Point Wiring, ( Light, Fan, Socket Or Power ) Complete With All Fitting, Fixtures Such As Switch Socket Out Let, Ceiling Rose, Holder, Regulator, Dbs Etc. Including Making Good The Disturbed Surface Of Wall / Floors, Complete All As Specified And As Directed. 2 Point Wiring With Multi Stranded Copper Conductor Of Size 1.5Sqmm Pvc Insulated Unsheathed Frls Cable In And Including Pvc Rigid Conduit Not Less Than 20Mm Dia ( Medium Grade ) Having Thickness As Per Is Code And Accessories Of Suitable Size Including 1.50 Sqmm Copper Earth Wire ( Green Colour ) Frls Cable For One Light Point Or Fan Point Or Bell Point Controlled By One No, One Way Switch Using Cable Of Different Insulation Colour For Colour Coding Including 3Mm Thick Laminated Sheet Cover, Mild Steel Sheet Or Cast Iron Boxes Including Making Good To Disturbed Surfaces Of Wall / Floor, Complete All As Specified And As Directed. 3 All As Per The Description Of Serial Item No 02 Here-In-Before But For One Light Point Controlled By Two, Two Way Switches All As Specified And Directed. 4 All As Per The Description Of Serial Item No 02 Here-In-Before But For One 3 Pin Socket Outlet 5 Amp On Same Board, Complete All As Specified And As Directed. 5 All As Per The Description Of Serial Item No 02 Here-In-Before But For One 3 Pin Socket Outlet 5 Amp Independent, Complete All As Specified And As Directed. 6 All As Per The Description Of Serial Item No 02 Here-In-Before But For One 3 Pin Socket Outlet 15 Amp Independent Board Using Cable Of Size 4.0 Sqm With 2.5 Sqmm Copper Conductor In Green Colour For As Earth Continuity Conductor All As Specified And Directed. 7 Point Wiring With Multi Stranded Copper Conductor Of Size 1.5Sqmm Pvc Insulated Unsheathed Frls Cable In And Including Pvc Casing And Capping And Accessories Of Suitable Size For Concealed Wiring Including 1.50 Sqmm Copper Earth Wire ( Green Colour ) Frls Cable For One Light Point Or Fan Point Or Bell Point Controlled By One No, One Way Switch Using Cable Of Different Insulation Colour For Colour Coding Including 3Mm Thick Laminated Sheet Cover, Mild Steel Sheet Or Cast Iron Boxes Including Making Good To Disturbed Surfaces Of Wall / Floor, Complete All As Specified And As Directed. 8 All As Per The Description Of Serial Item No 07 Here-In-Before But For One 3 Pin Socket Outlet 5 Amp On Same Board, Complete All As Specified And As Directed. 9 All As Per The Description Of Serial Item No 07 Here-In-Before But For One 3 Pin Socket Outlet 5 Amp Independent, Complete All As Specified And As Directed. 10 All As Per The Description Of Serial Item No 07 Here-In-Before But For One 3 Pin Socket Outlet 15 Amp Independent Board Using Cable Of Size 4.0 Sqm With 2.5 Sqmm Copper Conductor In Green Colour For As Earth Continuity Conductor All As Specified And Directed. 11 Tube Light Fitting Box Type Suitable For And Including Led 22 Watt Tube Rod 4 Long In Polycarbonate Housing And All Accessories Pre-Wired And Making Connections With Three Core Copper Flexible Cable Of Size 23 / 0.0076 From Ceiling Rose To Pvc Connector To Light Fitting Complete All As Specified And As Directed. Nmake : Havells Higher Wattage Cat Part No Lhexbtp7in1s022 Or Equivalent In Philips / Wipro / Crompton / Syska 12 Tube Light Fitting Box Type Suitable For And Including Led 10 Tube Rod 2 Long With Decorative Colour In Polycarbonate Housing And All Accessories Pre-Wired And Making Connections With Three Core Copper Flexible Cable Of Size 23 / 0.0076 From Ceiling Rose To Pvc Connector To Light Fitting Complete All As Specified And As Directed. Nmake : Havells E-Lite Led Pride Plus Neo Cat Part No Lhexbtp7in1w009 Or Equivalent In Philips / Wipro / Crompton / Syska 13 Led Bulb 230 Volt 09 Watts, Alongwith Angle Holder, In White Colour With Minimum Lumen Out Put ( Lm ) 900 K, Base Cap B-22, Complete All As Specified And As Directed. Nmake : Havells / Crompton Greaves / Philips / Wipro 14 Led Lamp 230 Volt 09 Watts, Complete All As Specified And As Directed. Nmake : Havells / Crompton Greaves / Philips / Wipro 15 Led Lamp 230 Volt 07 Watts, Complete All As Specified And As Directed. Nmake : Havells / Crompton Greaves / Philips / Wipro 16 Led Recess Luminaire, With High Brightness Smd Leds As Light Source, Suitable For Armstrong / Grid Ceiling, 2 X 2 Size, 34 / 36 Watts Including Making Connection From Ceiling Rose To Fitting With Pvc Insulated Sheathed Flexible Copper Conductor Cable Of Size 0.75 Sqmm Complete All As Specified And As Directed. Nmake : Havells Cat Part No Plutoneo2x2plr34wled857s Or Equivalent In Syska / Wipro / Philips / Crompton 17 Led Recess Luminaire, Glare Free Uniform Illumination, 1 X 1 Size, 24 Watts Including Making Connection From Ceiling Rose To Fitting With Pvc Insulated Sheathed Flexible Copper Conductor Cable Of Size 0.75 Sqmm Complete All As Specified And As Directed. Nmake : Syska Cat Part No Ssk-Pa3030f Or Equivalent In Havells / Wipro / Philips / Crompton 18 Recess Mounted Compact Round Led Panel, 24 Watts With All Accessories Prewired, Including Any Cutting / Alteration To False Ceiling As Required For Housing The Downlighter And Making Connection From Ceiling Rose To Fitting With Pvc Insulated Sheathed Flexible Copper Conductor Cable Of Size 0.75 Sqmm Complete All As Specified And As Directed. Nmake : Syska Cat Part No Ssk-Gdl-R-24W Or Equivalent In Havells / Wipro / Philips / Crompton 19 Switch Piano, Flush Type, 5 Amps, Single Pole, One Way, Complete All As Specified And As Directed. 20 Switch Piano, Flush Type, 5 Amps, Two Way, Complete All As Specified And As Directed. 21 Socket Out Let 3 Pin 5 Amp, Piano Flush Type, 240 Volts, Complete All As Specified And As Directed. 22 Switch Socket Out Let Combination Universal Type, 2 In 1, 2 And 3 Pin 5 Amp, Piano Flush Type, 240 Volts, Complete All As Specified And As Directed. 23 Switch Socket Outlet Combination Universal Type, 2 In 1, 3 Pin 5 And 15 Amp, Piano Flush Type, 240 Volts, Complete All As Specified And As Directed. 24 Ceiling Rose Surface Bakelite Three Terminals 240 Volts Complete All As Specified And As Directed. 25 Bell / Buzzer, Ding Dong Ac. 230 Volts, Single Pole All As Specified And Directed. 26 Bell Push Flush Type, One Way 5 Amps Single Pole One Way All As Specified And Directed. 27 Mcb Sp 6 To 32 Amp 10 Ka 240 Volts, C Curve, Complete All As Specified And As Directed. 28 Mcb Spn 20 To 32 Amp 10 Ka 240 Volts, C Curve, Complete All As Specified And As Directed. 29 Mcb Spn 40 To 63 Amp 10 Ka 240 Volts, C Curve, Complete All As Specified And As Directed. 30 Mcb Tpn 40 Amp 10 Ka 240 Volts, C Curve, Complete All As Specified And As Directed. 31 Isolator Tpn, 63 Amp, 415 Volt, Complete All As Specified And As Directed. 32 Rccb Double Pole 40 Amps, 240 V, 50 Hz, Breaking Capacity 10 Ka And Sensitivity 100 Ma Suitable For Lighting And Other Domestic Loads Complete All As Specified And Directed. 33 Rccb Four Pole 63 Amps, 240 V, 50 Hz, Breaking Capacity 10 Ka And Sensitivity 100 Ma Suitable For Lighting And Other Domestic Loads Complete All As Specified And Directed. 34 Sheet Metal Enclosure Factory Made Single Door For Db 240 Volts With 200 Amps Rated Bus Bar Spn 4 Way Including Taking Down And Making Good Disturbed Surfaces Of Walls, Complete All As Specified And As Directed. N 35 Sheet Metal Enclosure Factory Made Double Door For Db 240 Volts With 200 Amps Rated Bus Bar Spn 4 Way Including Taking Down And Making Good Disturbed Surfaces Of Walls, Complete All As Specified And As Directed. N 36 Sheet Metal Enclosure Factory Made Single Door For Db 240 Volts With 200 Amps Rated Bus Bar Spn 8 Way Including Taking Down And Making Good Disturbed Surfaces Of Walls, Complete All As Specified And As Directed. N 37 Sheet Metal Enclosure Factory Made Double Door For Db 240 Volts With 200 Amps Rated Bus Bar Spn 8 Way Including Taking Down And Making Good Disturbed Surfaces Of Walls, Complete All As Specified And As Directed. N 38 Sheet Metal Enclosure Factory Made Double Door For Db 240 Volts With 200 Amps Rated Bus Bar Tpn, Per Phase Isolation ( Ppi ) Horizontal 4 Quadrant Including Taking Down And Making Good Disturbed Surfaces Of Walls, Complete All As Specified And As Directed. N 39 Sub Main Wiring With Two Single Core Pvc Insulated Multistranded Un-Sheathed Frls Cable Of Size 4.0 Sqmm With Stranded Copper Conductor, Drawing Into Pvc Casing Capping ( Including Pvc Casing Capping And Accessories ) With Continuous Pvc Insulated Multistranded Unsheathed Frls Cable Earth Wire Of 2.5 Sqmm Dia Including Taking Out Unserviceable Sub Main Wiring, Complete All As Specified And Directed. Nnote : Two Run Of 4.0 Sqmm Wire, One Run Of 2.5 Sqmm Wire And One Run Of Pvc Conduit Shall Be Considered As One Unit Length. 40 Sub Main Wiring With Two Single Core Pvc Insulated Multistranded Un-Sheathed Frls Cable Of Size 6.0 Sqmm With Stranded Copper Conductor, Drawing Into Pvc Casing Capping ( Including Pvc Casing Capping And Accessories ) With Continuous Pvc Insulated Multistranded Unsheathed Frls Cable Earth Wire Of 2.5 Sqmm Dia Including Taking Out Unserviceable Sub Main Wiring, Complete All As Specified And Directed. Nnote : Two Run Of 6.0 Sqmm Wire, One Run Of 2.5 Sqmm Wire And One Run Of Pvc Conduit Shall Be Considered As One Unit Length. 41 1100 Volt Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Over All Pvc Sheathed In Service Connection Suspended By Insulating Hanger Not More Than 1 Mtr Apart Including 4 Mm Suspension Wire, One Twin Core Cable Flat Or Circular 10 Sqmm Stranded Conductor, Including Taking Down Old Unserviceable Service Connection Complete Complete All As Specified And Directed. 42 1100 Volt Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Over All Pvc Sheathed In Service Connection Suspended By Insulating Hanger Not More Than 1 Mtr Apart Including 4 Mm Suspension Wire, One Twin Core Cable Flat Or Circular 16 Sqmm Stranded Conductor, Including Taking Down Old Unserviceable Service Connection Complete Complete All As Specified And Directed. 43 Rewinding Of Exhaust Fan, 230 Volts, 50 Hz, 450Mm Sweep Of Any Make With Appropriate Gauge Super Enamelled Copper Winding Wire Including Allied Insulation Material Such As Air Drying Insulation Varnish, Cotton Tapes, Lathered Film Paper, Spacers, Sleeves Etc Re-Assembling At Its Position After Repair, Testing And Commissioning, Complete All As Specified & Directed. Nmake : Atlas / Finolex / Gec 44 Earthing Complete With Galvanized Mild Steel Earth Plate Electrode Size 600Mm X 600Mm X 6Mm Thick Buried Directly In Ground ( Preferably In Vertical Position ) Earth Pit Not Less Than 2.25 Meter Below Normal Ground Level With Top Edge Of The Earth Plate Not Less 3 Meter ( Bgl ) Connected To Galvanized Iron Earth Lead Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nut And Washer Of Galvanized Iron Including Pcc Pit In Rcc 1:2:4 Type B-1, Precast Rcc Cover With Suitable Handle, Excavation And Earth Work In Any Type Of Soil, 20Mm Bore “Medium Grade” Galvanized Iron Water Tubing Fixed With Cast Iron Funnel And Wire Mesh And 15Mm Bore “Light Grade” Galvanized Iron Protection Pipe For Earth Lead Wire Upto 5M Length, Charcoal, Common Salt, Complete All As Shown In Ep No 3 Of Ssr 2009 Part-I, Connected To Test Point Complete, All As Specified And Testing On Completion.

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work : REPAIR / REPLACEMENT AND MAINTENANCE OF INTERNAL WIRING, FITTINGS, MCBs, SERVICE CABLE AND MISC ITEMS AT CBS BHALRA, MTN BDE AND EWS UNDER GE (I) 873 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking out carefully copper / aluminium point wiring, (Light, fan, socket or power) complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator, DB's etc. including making good the disturbed surface of wall/floors, complete all as specified and as directed. 890 Point
2 2 Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including PVC rigid conduit not less than 20mm dia (medium grade) having thickness as per IS code and accessories of suitable size including 1.50 Sqmm copper earth wire (green colour) FRLS Cable for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including making good to disturbed surfaces of wall / floor, complete all as specified and as directed. 210 Point
3 3 All as per the description of Serial Item No 02 here-in-before but for one light point controlled by two, two way switches all as specified and directed. 40 Point
4 4 All as per the description of Serial Item No 02 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed. 40 Point
5 5 All as per the description of Serial Item No 02 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed. 80 Point
6 6 All as per the description of Serial Item No 02 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed. 70 Point
7 7 Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including PVC casing and capping and accessories of suitable size for concealed wiring including 1.50 Sqmm copper earth wire (green colour) FRLS Cable for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including making good to disturbed surfaces of wall / floor, complete all as specified and as directed. 210 Point
8 8 All as per the description of Serial Item No 07 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed. 70 Point
9 9 All as per the description of Serial Item No 07 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed. 80 Point
10 10 All as per the description of Serial Item No 07 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed. 90 Point
11 11 Tube light fitting box type suitable for and including LED 22 Watt tube Rod 4' long in polycarbonate housing and all accessories pre-wired and making connections with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connector to light fitting complete all as specified and as directed. \nMake : Havells 'Higher wattage' Cat Part No LHEXBTP7IN1S022 or equivalent in Philips / Wipro / Crompton / Syska 700 Each
12 12 Tube light fitting box type suitable for and including LED 10 tube Rod 2' long with decorative colour in polycarbonate housing and all accessories pre-wired and making connections with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connector to light fitting complete all as specified and as directed. \nMake : Havells 'E-Lite LED Pride Plus Neo' Cat Part No LHEXBTP7IN1W009 or equivalent in Philips / Wipro / Crompton / Syska 200 Each
13 13 LED Bulb 230 volt 09 watts, alongwith angle holder, in white colour with minimum Lumen out put (LM) 900 K, base cap B-22, complete all as specified and as directed. \nMake : Havells / Crompton Greaves / Philips / Wipro 90 Each
14 14 LED Lamp 230 volt 09 watts, complete all as specified and as directed. \nMake : Havells / Crompton Greaves / Philips / Wipro 197 Each
15 15 LED Lamp 230 volt 07 watts, complete all as specified and as directed. \nMake : Havells / Crompton Greaves / Philips / Wipro 197 Each
16 16 LED recess luminaire, with high brightness SMD LEDs as light source, suitable for Armstrong / Grid ceiling, 2' x 2' size, 34 / 36 Watts including making connection from ceiling rose to fitting with PVC insulated sheathed flexible copper conductor cable of size 0.75 Sqmm complete all as specified and as directed.\nMake : Havells Cat Part No PLUTONEO2X2PLR34WLED857S or equivalent in Syska / Wipro / Philips / Crompton 15 Each
17 17 LED recess luminaire, glare free uniform illumination, 1' x 1' size, 24 watts including making connection from ceiling rose to fitting with PVC insulated sheathed flexible copper conductor cable of size 0.75 Sqmm complete all as specified and as directed.\nMake : Syska Cat Part No SSK-PA3030F or equivalent in Havells / Wipro / Philips / Crompton 10 Each
18 18 Recess mounted compact Round LED Panel, 24 Watts with all accessories prewired, including any cutting / alteration to false ceiling as required for housing the downlighter and making connection from ceiling rose to fitting with PVC insulated sheathed flexible copper conductor cable of size 0.75 Sqmm complete all as specified and as directed.\nMake : Syska Cat Part No SSK-GDL-R-24W or equivalent in Havells / Wipro / Philips / Crompton 10 Each
19 19 Switch piano, flush type, 5 Amps, single pole, one way, complete all as specified and as directed. 420 Each
20 20 Switch piano, flush type, 5 Amps, two way, complete all as specified and as directed. 80 Each
21 21 Socket out let 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed. 100 Each
22 22 Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed. 250 Each
23 23 Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed. 150 Each
24 24 Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed. 420 Each
25 25 Bell / Buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed. 14 Each
26 26 Bell push flush type, one way 5 Amps single pole one way all as specified and directed. 14 Each
27 27 MCB SP 6 to 32 Amp 10 KA 240 Volts, 'C' curve, complete all as specified and as directed. 140 Each
28 28 MCB SPN 20 to 32 Amp 10 KA 240 Volts, 'C' curve, complete all as specified and as directed. 30 Each
29 29 MCB SPN 40 to 63 Amp 10 KA 240 Volts, 'C' curve, complete all as specified and as directed. 10 Each
30 30 MCB TPN 40 Amp 10 KA 240 Volts, 'C' curve, complete all as specified and as directed. 12 Each
31 31 Isolator TPN, 63 Amp, 415 volt, complete all as specified and as directed. 12 Each
32 32 RCCB Double Pole 40 Amps, 240 V, 50 Hz, breaking capacity 10 KA and sensitivity 100 mA suitable for lighting and other domestic loads complete all as specified and directed. 4 Each
33 33 RCCB Four Pole 63 Amps, 240 V, 50 Hz, breaking capacity 10 KA and sensitivity 100 mA suitable for lighting and other domestic loads complete all as specified and directed. 3 Each
34 34 Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed. \n 10 Each
35 35 Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed. \n 8 Each
36 36 Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed. \n 7 Each
37 37 Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed. \n 6 Each
38 38 Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar TPN, per phase Isolation (PPI) Horizontal 4 quadrant including taking down and making good disturbed surfaces of walls, complete all as specified and as directed. \n 10 Each
39 39 Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into PVC Casing capping (including PVC Casing capping and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. \nNote : Two run of 4.0 Sqmm wire, one run of 2.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length. 200 Running Metre
40 40 Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into PVC Casing capping (including PVC Casing capping and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. \nNote : Two run of 6.0 Sqmm wire, one run of 2.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length. 100 Running Metre
41 41 1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 10 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed. 100 Running Metre
42 42 1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 16 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed. 100 Running Metre
43 43 Rewinding of Exhaust Fan, 230 volts, 50 Hz, 450mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed.\nMake : Atlas/ Finolex / GEC 35 Each Job
44 44 Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion. 18 Each \nSet
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail