East Coast Railway has published Smoke Evacuator.. Submission Date for this Tender is 05-10-2020. Chemical Supply Tenders in Odisha. Bidders can get complete Tender details and download the document.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | |
---|---|---|---|---|---|---|---|---|---|---|
0 | S.No. | PL Code\r(Group) | Item Type\rGST(Y/N) | Stock /\rNonStock | Ordering | Consider\rFor Eval | Approving\rAgency | Inspection\rAgency | Currency\rAllowed | Estimated\rRate |
1 | 1 | 8279N001 | Goods (Y) | Non Stock | --- | Yes | CONSIGNEE | INR | ||
2 | Description :SMOKE EVACUATOR. Specification of Surgical Smoke Evacuator: (I) The Smoke Evacuator is\rintended to evacuate and filter surgical smoke plume and aerosols created in any surgical procedure by an active\rdevice. (II)The Smile Evacuator should automatically activate when active (Smoke Producing) device such as\rCautery machine is activated. (III) The Smoke Evacuator should automatically turn off after the active device\rturns off. (IV) The first stage filtration should trap and remove gross particulate and casual fluid. (V) The second\rfiltration that is ULPA grade filter whose high tech design captures particulates and micro-organisms from 1 to 2\rmicrons at an efficiency of 99.999%. (VI) The third stage filtration is an expanded foam used to trap activated\rcarbon fines from migrating out of the filter. (VII) Noise level should be less than or equal to 55.0 dBA (VIII) Time\rDelay option through RH sensor for residual smoke. (IX) System should offer 3 suction speed options up to 700\rLt/Minuit. (X) Filter Life should be>34 Hours. (XI) Should have a LED display & should come with a foot-switch.\r(XII) The smoke evacuation system should comply with IEC602001.1 electrical specifications & should have\rClass I Protection against electrical shock (UL606021-1,Clause 5.1) (XIII) Technical Specifications: WEIGHT:\rLess than 4.3 lbs OPERATING ENV. Temp.: 10 degree - 40 degree C Range of operating environment. POWER\rREQUIREMENTS : 220/240 VAC Frequency Auto sensed: 50/60 Hz The unit should comprise of following\rinstrument. 1. Smoke evacuator system with foot-switch- 1pc 2. RF Sensor-1pc 3. Micro safe filter- 1pc 4. Fluid\rtrap- 10 pcs 5. Open surgery smoke evacuator pencil with PTEE coated tip (reduce smoke generation) &\rtelescopic length of device allows surgeon to adjust the pencil by a full of 6 inches. 6. Laparoscopic tubing. | |||||||||
3 | Consignee | MD/CH/MCS | Odisha | 1.00 Numbers | ||||||
4 | AMC1 | Service\r(Y) | Non Stock | --- | Yes | CONSIGNEE | INR | |||
5 | Description :Firm to be furnished: charges of AMC along with the cost of items to be used in preventive\rscheduled for 1st year post warranty period of 2 years. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail