Special Repair/Replacement Of Unserviceable Solar Led Lights In Cantt Area , Provn Of Electrical Steam Generator For Mechanical Laundry In Mh , Soalr Water Heater For Ors Bathroom Of 5221 Asc Bn And Two Fire Alarm Sirens For Sasf At Nasirabad, NASIRABAD-Rajasthan

Military Engineer Services-MES has published Special Repair/Replacement Of Unserviceable Solar Led Lights In Cantt Area , Provn Of Electrical Steam Generator For Mechanical Laundry In Mh , Soalr Water Heater For Ors Bathroom Of 5221 Asc Bn And Two Fire Alarm Sirens For Sasf At Nasirabad. Submission Date for this Tender is 06-10-2020. Sirens Tenders in NASIRABAD Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

25476832
Special Repair/Replacement Of Unserviceable Solar Led Lights In Cantt Area , Provn Of Electrical Steam Generator For Mechanical Laundry In Mh , Soalr Water Heater For Ors Bathroom Of 5221 Asc Bn And Two Fire Alarm Sirens For Sasf At Nasirabad
Open Tender
Indian
Rajasthan
NASIRABAD
06-10-2020

Tender Details

Special Repair/Replacement Of Unserviceable Solar Led Lights In Cantt Area , Provn Of Electrical Steam Generator For Mechanical Laundry In Mh , Soalr Water Heater For Ors Bathroom Of 5221 Asc Bn And Two Fire Alarm Sirens For Sasf At Nasirabad

Key Value

Document Fees
INR 500 /-
EMD
INR 27000.0 /-
Tender Value
INR 13.50 Lakhs /-

BOQ Items

NAME OF WORK : SPECIAL REPAIR/REPLACEMENT OF UNSERVICEABLE SOLAR LED LIGHTS IN CANTT AREA AT NASIRABAD, PROVN OF ELECTRICAL STEAM GENERATOR FOR MECHANICAL LAUNDRY IN MH AT NASIRABAD, PROVN OF SOALR WATER HEATER FOR OR’S BATHROOM OF 5221 ASC BN AND PROVN OF TWO FIRE ALARM SIRENS FOR SASF AT NASIRABAD.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 S&F driver (PCB) suitable as per existing current rating with 12 volt DC system, including taking down old unserviceable driver (PCB) from solar light complete all as specified and directed. Note:-Cost of wire terminals, soldering/clipings required at site for proper fuctioning of the solar lights is deemed to be included quoted rates under this items. 41 Each
2 2 S&F 9 watt LED solar light fittings including cleaning of solar panel and charging to existing 12 Volt, 40 to 200 Ah battery and also top up distilled water/electrolite as required at site and fixing at same place for conditioning battery to make complete functional and testing on completion, Including cleaning the existing surface rust free by scratching out old paint, preparation of the surface and applying two coats of aluminium paint marking pole numbers/writing letters or figures (block, Roman in yellow circle, including taking out old unserviceable solar light fittings any watt, complete all as directed. Make of light fitting :- Bajaj / Havels/Cromption /Philips /Surya Notes :- (a) Cable if required to be replaced shall be measured and paid separately (b) Batteries shall be measured and paid separately. (c) Battery box shall be measured and paid separately.\n 115 Each Job
3 3 S&F solar battery box made of 20 SWG sheet hinged type as per exising design and size with locking arrangement of existing size and model to fix into angle iron frame with suitable size of clamps, nuts, bolts and washers etc., including taking out old UNSV/broken solar battery box complete all as specified and directed by Engr-in-charge.\n 60 Each
4 4 S&F GI tubular pole 6 metre in height and with mounting arrangement for panel/battery/light fitting including excavation and earth work, PCC work of size 300 mm dia and 300 mm in height with PCC 1:3:6 type C-2 using 20mm graded stone aggregate and plastering to exposed surface with rendering 10mm thick in CM 1:4 including taking out old unserviceable rusted GI tubular pole complete all as directed by Engineer-in-Charge. 20 Each Job
5 5 S&F polycrystalline PV panel suitable for 12V/40Ah Battery with Battery backup of min 7 to 8 hrs including taking out old unserviceable /broken solar panel of existing size and capacity, complete all as specified and directed by Engr-in-charge. 10 Each
6 6 S&F polycrystalline PV panle suitable for 12V/75Ah Battery with Battery backup of min 7 to 8 hrs including taking out old unserviceable /broken solar panel of existing size and capacity complete all as specified and directed by Engr-in-charge 8 Each
7 7 S&F polycrystalline PV panle suitable for 12V/100 Ah Battery backup of min 7 to 8 hrs including taking out old unserviceable /broken solar panel of existing size and capacity complete all as specified and directed by Engr-in-charge. 4 Each
8 8 Supply, fixing, jointing and testing PVC insulated copper cable 1 Sqmm 2 core multi strand with fitting / accessories including taking out old unserviceable copper cable laid in pipe, poles complete all as specified and directed 300 RM
9 9 S&F 12 Volt, 40 Ah solar tubular battery with minimum warranty of 2 years including taking out old unserviceable battery any size and capacity complete all as specified and directed. Make: Exide/Amaron/Microtec/Luminous. 50 Each
10 10 S&F 12 Volt , 75 Ah solar tubular battery with minimum warranty of 2 years including taking out old unserviceable battery of any size and capacity complete all as specified and directed. Make: Exide/Amaron/Microtec/Luminous. 10 Each
11 11 S&F 12 Volt , 100 Ah solar tubular battery with minimum warranty of 2 years including taking out old unserviceable battery any size and capacity complete all as specified and directed. Make:Exide/Amaron/Microtec/Luminous. 8 Each
12 12 Supply, installation, commissioning & testing of an electrical steam generator of capacity of 12 KW to run vacuum ironing table, fully automatic with 1 HP heavy duty water feeding pump, heavy duty pressure control, auto pressure control, low water level cut off, fully powder coated with imported safety valve complete, in all respect.\nMake: Super Fab/Electrolux/Fabcare Garments & Textile Machinery (P) Ltd/Supershine Laundary System. 1 Each
13 13 Supply, installation, testing and commissioning of solar water heating system suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of Solar flat plate collector, collector stand assembly, stainless steel insulated hot water storage tank with heat exchanger of 200 Litres per day capacity with electrical back up with collector "A" size aluminium box collector and comprising of following:-\n 1 Each
14 13.1 Solar flat plate collector, ISI Marked {IS-12933 (Pt-I) - 1992 with amendment no 1 & 2 }, having outer nominal dimension of 1860 mm X 1240 mm X 110 mm, material aluminium cast type channel and angle, back covering 22 SWG aluminium sheet, Upper covering not less than 4 mm thick tempered / toughened glass absorber - selectively coated copper fins and tubes, nominal fins size 0.2 mm thick X 1716 mm length, tube size 24 SWG X 12.70 mm OD X 1721 length, insulation 50mm thick mineral wool of 48 Kg/Cum density, reflector 18 guage aluminium foil, gasket EPDM /SPDM/Neoprene, flanges 62mm OD X 3 mm thick brass flanges header pipe 22 SWG X 25.4 mm OD S 1320 mm length complete -01 Nos
15 13.2 Insulated stainless steel hot water storage tank, non pressure type made out of stainless steel grade 04 Cr 18 NI of IS 1570 (Part-3)-1985 , TIG welded of 200 liters capacity, non magnetic tank with stainless steel fittings with following specification -01 Nos (a) Tank shall be insulated with 40 mm thermal grade PU insulation with FRP cladding. Tank stand assembly made of angle of size 38x38x4mm duly pretreated and stove enameled with black colour paint, complete.\n(b) Provision of electrical back up with minimum 4 KW heating element including providing one No 32 Amps MCB 10 KA, rupturing capacity with Metal clad box and top complete.\n(c) The Solar water heating system shall be provided on Platform on ground made out of PCC 1;2;4, type B1 and 45 cm in height as per manufacturer direction.\n(d) Heat exchanger shall be cage type and make of stainless steel tube of grade 04 Cr 18 NI of 07 18 N of IS 1570 (Par-5) -1885\n(e) All other pipe / civil work connection work for PVC tank as per OEM recommendation, electrical work, outlet and inlet thermometer, Air release valve, check valves, gate valves controls and instruments are all as required shall be deemed to be included in Unit rate quoted by contractor. System internal piping shall be ISI marked, GI pipe medium garde of IS:1239 duly insulated with 50 mm thick rock wool of 48 Kg/ Cum density and 26 SWG Aluminium cladding\nNotes - The system shall be tested on completion to ensure that 200 Ltrs (as specified) of water at 60 degree centigrade is available in hot water tank on a normal day in cold season\n
16 14 S&F 500 Litre capacity rotational moulded polyethylene water storage tanks, double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. 1 Each
17 15 M&L for fabrication work of joist, channel, angle or tee sections, flat iron fixed independently, without connecting plates etc complete, Fe-410 W (Gde E-250) quality 'B', complete for mounting of PVC tank of 500 Ltrs capacity for Solar water heater at staging complete all as specified and directed.\n 250 Kg
18 16 Excavation in trenches in any type of soil not exceeding 1.5 m deep and not exceeding 1.5 m wide for foundation of stand of tank, laying of cables, RCC/Steel tubular poles/stays and struts etc and getting out ncluding trimming sides and forming bottom surface, complete, all as specified and directed at site. 18.82 Cum
19 17 M&L for plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation & mass concrete complete all as specified and directed.\n 2 Cum
20 18 M&L for carryout necessary glass wool insulation comprising of 100 mm outer dia (compressed) glass wool on 20 mm bore GI tubing with 26 gauge aluminium sheet over chicken mesh complete all as specified and directed by Engineer-in-charge.\n 42 RM
21 19 S&F 25mm bore Gi tubing medium grade with fittings and fixed to walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-Charge. 36 RM
22 20 S&F 20mm bore Gi tubing medium grade with fittings and fixed to walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-Charge. 48 RM
23 21 S&F stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 20mm bore Gi tubing complete all as specified & directed by Engineer-in-Charge 1 Each
24 22 S&F bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipes or for brass ferrule and fixed of 20mm bore GI tubing complete all as directed by Engineer-in-Charge. 1 Each
25 23 S&F stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle. screwed both ends for of 25mm bore GI tubing complete all as directed by Engineer-in-Charge. 1 Each
26 24 Cutting Existing steel tubing for alterations or additions in 25 mm bore pipe, complete, all as specified and directed by Engineer-in-Charge. 1 Each
27 25 M&L for point wiring in PVC casing & caping/PVC conduit or concealed in some places as required at site of size confirming to IS 2079 1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FR) 4 sq mm, nominal cross sectional area 1100 volts grade complete with all fittings such as Elbow, bends, junction boxes, saddles inc PVC board (ISI Mark) and screws and rawl plugs etc including 2.5 samm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimble all as specified and directed by the Engr in-charge. 1 Each Point
28 26 S&F Sheet metal enclosures with socket plug top and MCBS single pole and neutral enclosure with a two pin and earth plug with socket with one single pole 20 Amp MCB, B series complete all as specified and directed. 3 Each
29 27 S&F 1100 volts grade heavy duty cable PVC insulated copper conductor served with inner sheathing of PVC tape and overall PVC sheathed of size 2.5 Sqmm 3 core complete all as specified and directed.\n 45 RM
30 28 Supply, laying, jointing and fasting of cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty, 1100 volts grade in stranded aluminium conductor of size 6 Sqmm, 2 core, laid in trenches/ducts, or fix to pipe on walls, poles etc., complete, all, as specified and directed.\nNote :- Excavation earth work, sand cushoning and cable cover will be measured and paid separately. 80 RM
31 29 Returning, filing in, including spreading leveling watering and well ramming in layers not exceeding of 25 cm thick in soft/loose soil, complete, all as specified and directed.\n 14.91 Cum
32 30 Removal of surplus soil obtained from excavetion to a dstance not exc. 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point, complete, ali as specified and directed. 1.41 Cum
33 31 Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top cable including spreading, levelling, watering and consolidation, complete all as specified and directed by Engineer-in-charge. Note: Punned thickness only shall be measured and paid. 1.32 Cum
34 32 Supply and laying of bricks of old class ‘B’ as protection cover to UG cable, laid flat adjoining to each other width wise, complete, all as specified. 0.54 Per 1000 Nos
35 33 Supply and laying GI tubing 40 mm bore, light grade with all fittings, laid in trenches/under floor or fixed on pole/on wall for cable protection. 12 RM
36 34 Supply, fabrication & fixing structural mild steel, RS joist, channel, angle iron, flat iron and bracket etc for fabrication of cross arms, bracing supports, clamps including 'D' clamp, eye hook and back plate etc., fabricated from structural steel section including nuts, bolts, washers, welding (cold and hot ), drilling holes for bolts, bend to any shape or size as indicated and directed, incusive of one primer coat and two coats of aluminium paint after preparation of surfaces, complete, all as specified and directed 3.5 Qtl
37 35 M&L for fire alarm sirens, Electronic type, horizontal sngle stage, continuous normal operation for at least 50 minutes with sound level 65 db to 120 db measured at 1.5 M with sound out put Variation of +5 db, 3500 metre range, complete, all as specified and directed. Make:- AHUJA/AGNI/ PHILLIPS/ MOTWANI 2 Each
38 36 M&L for carrying out boring under the black top road for crossing of LT cable protection pipe, by any means, boring machine or otherwise without damaging black top surtace of road for fixing of GI pipe B0mm bore under the road including making good of damaged roard surfaces with same specifications, complete, all as specified and directed. 6 RM
39 37 M&L for sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 6.00 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. 30 RM
40 38 S&F distribution board, single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 4 way, 415 volts suitable for housing MCB's complete all as specified and directed.\nNote: MCB DB and MCBs shall be of same make. 2 Each
41 39 S & F MCB, SPN, 240 volt, 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.\n 2 Each
42 40 S & F MCB SP, 240 volt, 6 Amp to 30 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.\n 2 Each
43 41 M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type C-2 and RCC 1:2:4 type B1 cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 2 Each