| 1 | 1 | Office Repair & Construction of 1st Floor | BI01010001010000000000000515BI0100001150 | | |
|---|
| 2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | BI01010001010000000000000515BI0100001151 | 35.03 | cum |
|---|
| 3 | 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001152 | 19.49 | cum |
|---|
| 4 | 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001153 | 33.83 | cum |
|---|
| 5 | 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001154 | 87.27 | cum |
|---|
| 6 | 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001155 | 37.92 | cum |
|---|
| 7 | 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars | BI01010001010000000000000515BI0100001156 | 4762.75 | Kg |
|---|
| 8 | 8 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001157 | 72.92 | sqm |
|---|
| 9 | 9 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001158 | 252.93 | sqm |
|---|
| 10 | 10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001159 | 17.515 | cum |
|---|
| 11 | 11 | Supplying and stacking at site good earth (exculding rock) and filling in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth, consolidation each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5 m, | BI01010001010000000000000515BI0100001160 | 21.525 | Cum |
|---|
| 12 | 12 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate | BI01010001010000000000000515BI0100001161 | 347.95 | sqm |
|---|
| 13 | 13 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick | BI01010001010000000000000515BI0100001162 | 209.32 | metre |
|---|
| 14 | 14 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001163 | 64.29 | sqm |
|---|
| 15 | 15 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | BI01010001010000000000000515BI0100001164 | 29.58 | sqm |
|---|
| 16 | 16 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001165 | 151.59 | kg |
|---|
| 17 | 17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | BI01010001010000000000000515BI0100001166 | 1008 | kg |
|---|
| 18 | 18 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001167 | 468 | kg |
|---|
| 19 | 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | BI01010001010000000000000515BI0100001168 | 15.6 | sqm |
|---|
| 20 | 20 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001169 | 951.33 | sqm |
|---|
| 21 | 21 | Wire mesh (rabbit) | BI01010001010000000000000515BI0100001170 | 204.24 | sqm |
|---|
| 22 | 22 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer | BI01010001010000000000000515BI0100001171 | 598.39 | sqm |
|---|
| 23 | 23 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. | BI01010001010000000000000515BI0100001172 | 525.86 | sqm |
|---|
| 24 | 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001173 | 76.56 | sqm |
|---|
| 25 | 25 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes | BI01010001010000000000000515BI0100001174 | 30.24 | sqm |
|---|
| 26 | 26 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | BI01010001010000000000000515BI0100001175 | 40.9 | sqm |
|---|
| 27 | 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001176 | 20 | metre |
|---|
| 28 | 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001177 | 20 | metre |
|---|
| 29 | 29 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. | BI01010001010000000000000515BI0100001178 | 500 | per litre |
|---|
| 30 | 30 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | BI01010001010000000000000515BI0100001179 | 3 | each |
|---|
| 31 | 31 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap | BI01010001010000000000000515BI0100001180 | 1 | each |
|---|
| 32 | 32 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. | BI01010001010000000000000515BI0100001181 | 1 | each |
|---|
| 33 | 33 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore | BI01010001010000000000000515BI0100001182 | 4 | each |
|---|
| 34 | 34 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore | BI01010001010000000000000515BI0100001183 | 2 | each |
|---|
| 35 | 35 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | BI01010001010000000000000515BI0100001184 | 27 | metre |
|---|
| 36 | 36 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler 110 mm | BI01010001010000000000000515BI0100001185 | 4 | each |
|---|
| 37 | 37 | Supplying and Fixing Electric pipe. | BI01010001010000000000000515BI0100001186 | 60.4 | metre |
|---|
| 38 | 38 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. | BI01010001010000000000000515BI0100001187 | 8 | each |
|---|
| 39 | 39 | Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. | BI01010001010000000000000515BI0100001188 | 33.75 | sqm |
|---|
| 40 | 40 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete | BI01010001010000000000000515BI0100001189 | 308.06 | sqm |
|---|
| 41 | 41 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) | BI01010001010000000000000515BI0100001190 | 266.05 | sqm |
|---|
| 42 | 42 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One or more coats) applied @ 1.82 ltr/10 sqm. | BI01010001010000000000000515BI0100001191 | 120.16 | sqm |
|---|
| 43 | 43 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work | BI01010001010000000000000515BI0100001192 | 33.36 | sqm |
|---|
| 44 | 44 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | BI01010001010000000000000515BI0100001193 | 7.09 | cum |
|---|
| 45 | 45 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. | BI01010001010000000000000515BI0100001194 | 19.4 | sqm |
|---|
| 46 | 46 | Godown Repair Work | BI01010001010000000000000515BI0100001195 | | |
|---|
| 47 | 47 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In lime mortar | BI01010001010000000000000515BI0100001196 | 52.64 | cum |
|---|
| 48 | 48 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001197 | 4000 | kg |
|---|
| 49 | 49 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on specially designedpipe shaft with brackets, side guides and arrangements for inside andoutside locking with push and pull operation complete, including thecost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover | BI01010001010000000000000515BI0100001198 | 184.08 | sqm |
|---|
| 50 | 50 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured). | BI01010001010000000000000515BI0100001199 | 130.56 | sqm |
|---|
| 51 | 51 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001200 | 706.8 | sqm |
|---|
| 52 | 52 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001201 | 14.81 | cum |
|---|
| 53 | 53 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos cement sheet | BI01010001010000000000000515BI0100001202 | 4578.51 | sqm |
|---|
| 54 | 54 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. | BI01010001010000000000000515BI0100001203 | 1521.2 | kg |
|---|
| 55 | 55 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001204 | 4451.27 | sqm |
|---|
| 56 | 56 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) | BI01010001010000000000000515BI0100001205 | 97.65 | metre |
|---|
| 57 | 57 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001206 | 51.02 | cum |
|---|
| 58 | 58 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001207 | 631.48 | sqm |
|---|
| 59 | 59 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001208 | 243.39 | sqm |
|---|
| 60 | 60 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):From brick work in lime mortar | BI01010001010000000000000515BI0100001209 | 11.017 | 1000 Nos |
|---|
| 61 | 61 | White washing with lime to give an even shade : New work (three or more coats) | BI01010001010000000000000515BI0100001210 | 356.7 | sqm |
|---|
| 62 | 62 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) | BI01010001010000000000000515BI0100001211 | 725.24 | sqm |
|---|
| 63 | 63 | Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. | BI01010001010000000000000515BI0100001212 | 651 | metre |
|---|
| 64 | 64 | INTERNAL ELECTRICAL WORK FOR OFFICE | BI01010001010000000000000515BI0100001213 | | |
|---|
| 65 | 65 | POINT WIRING | BI01010001010000000000000515BI0100001214 | | |
|---|
| 66 | 66 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B | BI01010001010000000000000515BI0100001215 | 16 | Point |
|---|
| 67 | 67 | Supply & Fixing of LED Light with batten suitable for up to 1x22 watt LED Tube light fitting including tube on surface complete in all respect CAT AAAA. | BI01010001010000000000000515BI0100001216 | 16 | Each |
|---|
| 68 | 68 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100001217 | 6 | Each |
|---|
| 69 | 69 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100001218 | 6 | Each |
|---|
| 70 | 70 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001219 | 3 | Each |
|---|
| 71 | 71 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001220 | 3 | Each |
|---|
| 72 | 72 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | BI01010001010000000000000515BI0100001221 | 40 | Metre |
|---|
| 73 | 73 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | BI01010001010000000000000515BI0100001222 | 35 | Metre |
|---|
| 74 | 74 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire | BI01010001010000000000000515BI0100001223 | 20 | Metre |
|---|
| 75 | 75 | DISTRIBUTION BOARDS,MCB'S & ISOLATORS: | BI01010001010000000000000515BI0100001224 | | |
|---|
| 76 | 76 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)2+6 way, Double door | BI01010001010000000000000515BI0100001225 | 1 | Each |
|---|
| 77 | 77 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door | BI01010001010000000000000515BI0100001226 | 1 | Each |
|---|
| 78 | 78 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001227 | 12 | Each |
|---|
| 79 | 79 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001228 | 1 | Each |
|---|
| 80 | 80 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001229 | 10 | Each |
|---|
| 81 | 81 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A | BI01010001010000000000000515BI0100001230 | 1 | Each |
|---|
| 82 | 82 | EARTHING | BI01010001010000000000000515BI0100001231 | | |
|---|
| 83 | 83 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001232 | 1 | Each |
|---|
| 84 | 84 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | BI01010001010000000000000515BI0100001233 | 25 | Metre |
|---|
| 85 | 85 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. | BI01010001010000000000000515BI0100001234 | 50 | Metre |
|---|
| 86 | 86 | INSTALLATION OF LIGHT FIXTURES : | BI01010001010000000000000515BI0100001235 | | |
|---|
| 87 | 87 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | BI01010001010000000000000515BI0100001236 | 16 | Each |
|---|
| 88 | 88 | INSTALLATION OF FANS AND EXHAUST FANS : | BI01010001010000000000000515BI0100001237 | | |
|---|
| 89 | 89 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. | BI01010001010000000000000515BI0100001238 | 3 | Each |
|---|
| 90 | 90 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep | BI01010001010000000000000515BI0100001239 | 2 | Each |
|---|
| 91 | 91 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. | BI01010001010000000000000515BI0100001240 | 2 | Each |
|---|
| 92 | 92 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia | BI01010001010000000000000515BI0100001241 | 5 | Metre |
|---|
| 93 | 93 | LAYING AND TERMINATION OF CABLE: | BI01010001010000000000000515BI0100001242 | | |
|---|
| 94 | 94 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. Mm | BI01010001010000000000000515BI0100001243 | 20 | Metre |
|---|
| 95 | 95 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) | BI01010001010000000000000515BI0100001244 | 2 | each |
|---|
| 96 | 96 | SUPPLY OF FANS AND EXHAUST FANS : | BI01010001010000000000000515BI0100001245 | | |
|---|
| 97 | 97 | Supply and erection of AC 1200mm Swep,230/250 Volts,50Hz ceilling fan with regulater standar down rod,blades including connection etc,complete as requiredMake:CG/Usha/Bajaj/Equivalent Make | BI01010001010000000000000515BI0100001246 | 2 | each |
|---|
| 98 | 98 | Supply of AC 230/250 Volts,50Hz exhaust fans including providing nuts,bolts, mounting frame and other accessories including connections etc complete as required-Make: USHA cat No. TURBO JET DLX 300mm sweep. | BI01010001010000000000000515BI0100001247 | 2 | each |
|---|