Supply Of Battery Discharge Resistor Load Banks Required For Unit#1, 2 & 3 1. 220 Volts, 400A Load Bank 220 Volt, 400 Amps, Discharge Resistor Bank: For 220 Volt, 3600 Ah, Battery Bank.Specification:1 ) Voltage : 220 Volts, 2 ) Current: 400 Amps, 3 ) Current Steps : 50 A X 6, 20 A X 3, 10 A X 3, 5 A X 2.4 ) Resistance: 50 A, 20 A, 10 A & 5 A - Stainless Steel Punched Grid Type Resistors.5 ) Switching: Dc Rotary Switches Of Make Kaycee Or Equivalent Make.6 ) Input Mccb: 400 Amps, Breaking Capacity: 250V, 10 Ka.7 ) Metering: Dc Analog 98X98 Mm Ae Or Equivalent Make.8 ) Cooling: Forced Air Cooled. Fan Supply: 1-Phase, 50Hz, 250Volts Ac, 1400 Rpm.9 ) Discharge Time : 10 Hrs.10 ) Enclosure: Ip-21 With Rotating ( 360 Deg ) Metal Wheels.11 ) The Resistor Elements Are To Be Supported On S.S. Tie Rods To Form Stacks, Insulated From Each Other & The Enclosure.With Micanite Tubes And Ceramic Forms.12 ) Size Of The Panel : Front View Size - 95 Cms, Side View Size-190Cms And Height - 195Cms.13 ) In Each Switches Protection Fuse To Be Provided.14 ) Detailed Drawing Including Panel Dimension To Be Furnished Along With The Enquiry., 2. 415 Volts, 150A Load Bank 384 Volt, 150 Amps, Discharge Resistor Bank: For 384 Volt, 1200 Ah, Battery Bankspecifications:1 ) Voltage: 384 Volts, 2 ) Current : 150 Amps, 3 ) Current Steps : 20 A X 5, 10 A X 4, 5 A X 2. 4 ) Resistance: 20 A, 10 A, & 5 A - Stainless Steel Punched Grid Type Resistors5 ) Switching : Dc Rotary Switches Of Make Kaycee Or Equivalent Make.6 ) Input Mccb: 200 Amps, Breaking Capacity:415V, 10Ka.7 ) Metering: Dc Analog 98X98 Mm Ae Or Equivalent Make.8 ) Cooling: Forced Air Cooled. Fan Supply: 1-Phase, 50Hz, 250Volts Ac, 1400 Rpm 9 ) Discharge Time : 10 Hrs.10 ) Enclosure: Ip-21 With Rotating ( 360 Deg ) Metal Wheels.11 ) The Resistor Elements Are To Be Supported On S.S. Tie Rods To Form Stacks, Insulated From Each Other & The Enclosure With Micanite Tubes And Ceramic Forms.12 ) Size Of The Panel : Front View Size - 95 Cms, Side View Size-190Cms And Height - 195Cms 13 ) In Each Switches Protection Fuse To Be Provided.14 ) Detailed Drawing Including Panel Dimension To Be Furnished Along With The Enquiry., 3. 30 Volts, 70A Load Bank 24 Volt, 70 Amps, Discharge Resistor Bank: For 24 Volt, 645Ah, Battery Bank Specification:1 ) Voltage : 24 Volts, 2 ) Current : 70 Amps, 3 ) Current Steps : 20 A X 2, 10 A X 2, 5 A X 2.4 ) Resistance: 20 A, 10 A, & 5 A - Stainless Steel Punched Grid Type Resistors .5 ) Switching: Dc Rotary Switches Of Make Kaycee Or Equivalent Make.6 ) Input Mccb: 100Amps, Breaking Capacity: 250V, 10 Ka. 7 ) Metering: Dc Analog 98X98 Mm Ae Or Equivalent Make.8 ) Cooling: Forced Air Cooled. Fan Supply: 1-Phase, 50Hz, 250Volts Ac, 40 Watts, 1400 Rpm.9 ) Discharge Time: 10 Hrs10 ) Enclosure: Ip-21 With Rotating ( 360 Deg ) Metal Wheels.11 ) The Resistor Elements Are To Be Supported On S.S. Tie Rods To Form Stacks, Insulated From Each Other & The Enclosure With Micanite Tubes And Ceramic Forms.12 ) Size Of The Panel: Front View Size - 95 Cms.13 ) In Each Switches Protection Fuse To Be Provided.14 ) Detailed Drawing Including Panel Dimension To Be Furnished Along With The Enquiry.,