Food Corporation Of India-FCI has published Conversion Of Valley Gutter Roof Into Single Span Roof Of G-1 And Replacement Of Ac Sheet Roofing With Precoated Gi Profile Sheet Roofing For G2 , G3 , G4 And Isolation Sheds At Fsd Kr Nagar For The Year 2020-21 . . Submission Date for this Tender is 25-08-2020. Shed Construction Tenders in K R NAGAR Karnataka. Bidders can get complete Tender details and download the document.
Name of Work: Conversion of valley gutter roof into single span roof of G-1 and replacment of AC sheet roofing with precoated Galvanised Iron profile sheet roofing for G2,G3 ,G4 & Isolation sheds at FSD KR NAGAR for the year 2020-21. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. | BI01010001010000000000000515BI0100001113 | 33 | Cum |
2 | 2 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet. | BI01010001010000000000000515BI0100001114 | 112 | sqm |
3 | 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : Asbestos sheet. | BI01010001010000000000000515BI0100001115 | 9437 | sqm |
4 | 4 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150 mm dia pipe | BI01010001010000000000000515BI0100001116 | 436 | metre |
5 | 5 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats. | BI01010001010000000000000515BI0100001117 | 22866 | kg |
6 | 6 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. | BI01010001010000000000000515BI0100001118 | 323 | kg |
7 | 7 | Brick work with burnt clay F P S ( non modular) of bricks class designation 7.5 in superstrcture above plinth level up to floor five level in all shpaes and sizes in cement mortar1:6 (1cement 6coarse sand) | BI01010001010000000000000515BI0100001119 | 48 | cum |
8 | 8 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001120 | 42 | Cum |
9 | 9 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand). | BI01010001010000000000000515BI0100001121 | 423 | sqm |
10 | 10 | White washing with lime to give an even shade : Old work (two or more coats) | BI01010001010000000000000515BI0100001122 | 6590 | sqm |
11 | 11 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete | BI01010001010000000000000515BI0100001123 | 5022 | sqm |
12 | 12 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer | BI01010001010000000000000515BI0100001124 | 5772 | sqm |
13 | 13 | Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface | BI01010001010000000000000515BI0100001125 | 5022 | sqm |
14 | 14 | Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. | BI01010001010000000000000515BI0100001126 | 180 | metre |
15 | 15 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. | BI01010001010000000000000515BI0100001127 | 1220 | metre |
16 | 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001128 | 9436 | sqm |
17 | 17 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm). | BI01010001010000000000000515BI0100001129 | 363 | metre |
18 | 18 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) | BI01010001010000000000000515BI0100001130 | 192 | metre |
19 | 19 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001131 | 34016 | kg |
20 | 20 | Labour charges for re-fixing the existing purlin to the newly formed angle truss including fixing in position as directed by Engineer-in-charge. (Required purlins will be supplied at free of cost at site of work) | BI01010001010000000000000515BI0100001132 | 378 | each |
21 | 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001133 | 1043 | sqm |
22 | 22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : one or more coats on old work | BI01010001010000000000000515BI0100001134 | 5055 | sqm |
23 | 23 | Lettering with black japan paint of approved brand and maufacture | BI01010001010000000000000515BI0100001135 | 27342 | per letter per cm height |
24 | 24 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001136 | 43 | cum |
25 | 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size). | BI01010001010000000000000515BI0100001137 | 5 | Cum |
26 | 26 | Providing and fixing turbo/ wind ventilators (extraction capacity of minimum 1800 cubic feet per minute air circulated fan of minimum 22 inches throat dia wind ventilator with FRP base plate) including cost of fixing turbo/ wind ventilators on new 6m thick Asbestos cement corrugated sheet roofing on godown roof including cost & transportation of all materials, tools and plants, fixtures/ fastenings, labour insurance, safety measures, disposal of broken A C sheets as directed by Engineer-in-charge including guarantee for turbo ventilator of minimum 3 years and performance warranty etc. complete. | BI01010001010000000000000515BI0100001138 | 36 | each |
27 | 27 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm. | BI01010001010000000000000515BI0100001139 | 27 | sqm |
28 | 28 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete | BI01010001010000000000000515BI0100001140 | 750 | sqm |
29 | 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete | BI01010001010000000000000515BI0100001141 | 400 | sqm |
30 | 30 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001142 | 400 | sqm |
31 | 31 | Dismantling rolling shutters including stacking the material within 50 metres lead of : | BI01010001010000000000000515BI0100001143 | 8 | each |
32 | 32 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover | BI01010001010000000000000515BI0100001144 | 56 | sqm |
33 | 33 | Repairing and Greasing of rolling shutters at the rate of 500 grams yellow cup grease of good quality each shutter after cleaning with Kerosene oil properly including tensioning of springs/ replacement of spring wherever required including replacement of damaged stripes and side koni complete and making easy push & pull operation and removing the top cover and refixing the same after greasing with all materials and labour etc., complete as directed by Engineer-in-charge. (This excludes the cost of spring and strips but including the cost of side koni).. | BI01010001010000000000000515BI0100001145 | 32 | each |
34 | 34 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001146 | 250 | sqm |
35 | 35 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | BI01010001010000000000000515BI0100001147 | 38 | cum |
36 | 36 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001148 | 263 | sqm |
37 | 37 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001149 | 13 | sqm |
38 | 38 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001150 | 40 | Cum |
39 | 39 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001151 | 3200 | kg |
40 | 40 | Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) at plinth level with - Cement mortar 1:6 (1 cement: 6 coarse sand) - RR Stones will be supplied by Department at free of cost at site of work. | BI01010001010000000000000515BI0100001152 | 27 | Cum |
41 | 41 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001153 | 5 | Cum |
42 | 42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,complete.Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001154 | 228 | sqm |
43 | 43 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in | BI01010001010000000000000515BI0100001155 | 228 | sqm |
44 | 44 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. | BI01010001010000000000000515BI0100001156 | 228 | sqm |
45 | 45 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001157 | 175 | sqm |
46 | 46 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001158 | 175 | sqm |
47 | 47 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001159 | 58 | kg |
48 | 48 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.00 mm thickness. | BI01010001010000000000000515BI0100001160 | 18 | sqm |
49 | 49 | Deduct for Salvage value of dismantled G.S. corrugated sheet and dismantled purlins as is whereis basis. | BI01010001010000000000000515BI0100001161 | 5031 | kg |
50 | 50 | Deduct for Salvage value of dismantled Asbestos sheet as is whereis basis. | BI01010001010000000000000515BI0100001162 | 9437 | sqm |
51 | 51 | Deduct for Salvage value of dismantled CI or PVC rain water pipes of 150mm Dia as is whereis basis. | BI01010001010000000000000515BI0100001163 | 436 | each |
52 | 52 | Deduct for Salvage value of dismantled rolling shutter as is whereis basis. | BI01010001010000000000000515BI0100001164 | 8 | each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy