Renovation Of Building Additions , Alterations And Renovation Of Water Supply And Sanitation Division Office No . 3 And Sub Division Office No . 7/8/9 , S . A . S . Nagar, SAS Nagar-Punjab

Water Supply And Sanitation Department-WSSD has published Renovation Of Building Additions , Alterations And Renovation Of Water Supply And Sanitation Division Office No . 3 And Sub Division Office No . 7/8/9 , S . A . S . Nagar. Submission Date for this Tender is 17-08-2020. Building Repair Tenders in SAS Nagar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

25054726
Renovation Of Building Additions , Alterations And Renovation Of Water Supply And Sanitation Division Office No . 3 And Sub Division Office No . 7/8/9 , S . A . S . Nagar
National Competitive Bid
Indian
Punjab
SAS Nagar
17-08-2020

Tender Details

Renovation Of Building Additions , Alterations And Renovation Of Water Supply And Sanitation Division Office No . 3 And Sub Division Office No . 7/8/9 , S . A . S . Nagar

Key Value

Document Fees
INR 1000 /-
EMD
INR 66500.0 /-
Tender Value
INR 33.24 Lakhs /-

BOQ Items

Name of Work: Additions, Alterations and Renovation of Water Supply and Sanitation Division Office No. 3 & Sub Division Office No. 7/8/9, S.A.S. Nagar Punjab Under PRWSSIP-II Sub Component 4-B
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Civil Work
2 1.01 Dismantling brick work tile masonary or tile lining. 24.38 Cum
3 2 Stripping and stacking slate or tiles of a roof. 393.77 Sqmt
4 3 Removing doors and windows together with the dismantling of walls
5 3.01 Doors 12 Each
6 3.02 Windows 5 Each
7 4 Dismantling asbestos cement, celotax or other hard board ceiling or partition walls including supporting timber. 263.94 Sqm
8 5 Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation 19.06 Cum
9 6 Cement Concrete 1:8:16 with 40mm\ngauge stone aggregate. 3.04 Cum
10 7 First class burnt brick work laid in cement sand mortar 1:7 in foundation and plinth. 16.99 Cum
11 7.01 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. 19.67 Cum
12 7.02 Extra rate for First Floor 2.87 Cum
13 8 Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded. 51 Sqm
14 9 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure 16.77 Sqmt
15 10 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. 1.37 Cum
16 11 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator bu excluding steel reinforcement centring and shuttering in superstructure. 5.67 Cum
17 12 Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 13.15 Sqm
18 13 Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 128.65 Sqm
19 14 Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels 19.6 Sqm
20 15 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25mm mud plaster 7.5cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 kg per sqm top of RCC slab including grouting with cement sand motor 1:4 and top surface to be left clean after wire brushing etc. & labour. ( through rate) ( new area ) 66.51 Sqm
21 15.01 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25mm mud plaster 7.5cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 kg per sqm top of RCC slab including grouting with cement sand motor 1:4 and top surface to be left clean after wire brushing etc. & labour. ( only labour part existing area) 265.07 Sqm
22 16 Repair of existing tIle terracing consisting of 25 mm mud plaster 7.5 cm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including laying existing used tiles over the existing RCC roof slab grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. Complete job\n(For 70% of area) 100.64 Sqmt
23 17 Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C.including bending, binding, and placing in position complete. 4.7 Qtl
24 18 Cement plastering
25 18.01 12.50 mm Cement Plaster 1:5 on walls 61.82 Sqm
26 18.02 12.5 mm thick cement plaster 1:4 24.41 Sqm
27 18.03 12.5 mm thick cement plaster 1:4 on celing 33.17 Sqm
28 19 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. 178.25 Mtr.
29 20 Earth filling with good quality earth obtained from outside the plinth including compensation of earth, loading, unloading, carriage from outside the premises to site of work, spreading, laying watering compacting with rammer complete as per specifications. 11.72 Cum
30 21 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar up to 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead up to 30 metres 7.81 Cum
31 22 Distempering with dry distemper of approved manufacture two coats on old distempetered surface. ( Division office -2000 sqmt + sub division office 1000 sqmt) 3420.1 Sqm
32 23 Providing and fixing alumiumum doors and windows with chowkhat frames, shutters including cost of specials such as hinges, tower bolts, door closers, rubber gaskets, glazing / laminated board. etc. Complete job inlcuding coating of aluminium powder coating
33 23.01 Door Size 2'-3" x 6'-9" = (5 nos for toilet) 5 Each
34 23.02 Door Size 3'-0" x 6'-9" = internal doors 9 Each
35 23.03 Window with glass/wire shutters 120 Sqft
36 24 Cupboards made out of Hollock wood frame, shutters made out of 19 mm thick commercial board duly finihsed with 0.75 mm thick laminate, shelves of 19 mm thick commercial board of 2' depth within cupuboard duly finished with enamel paint. Complete job including all hardwares, iron hold fasts, iron hinges, the cost of handles, bolts, nailing and screw , locks etc along with the internal and external surfaces duly finished with enamel paint of approved colour and make . 20 Sqmt
37 25 Providing and fixing hydraulic door closer ISI marked with necessary screw etc complete. 6 Each
38 26 Public health Works
39 26.01 Providing & fixing in position PVC water storage tanks make as approved by Engineer-in-Charge including hosting and carriage from store to site of work complete with providing and fixing 15mm or 20mm internal Diametre tanki nipple complete.(Excluding cost of platform).
40 26.02 Double Layer Tanks
41 26.03 Total storage = 1 x 1000 1000 Ltr.
42 27 Providing and fixing in position automatic brass ball valves in tanks.
43 27.01 20mm i/d Brass Ball Cock with rod and Plastic Ball 1 Each
44 28 Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
45 28.01 G.I. tank nipple 20mm i/d 2 Each
46 29 Construction of platform for placing PVC water storage tank with brick ballast work, plaster, CC 1 : 8 : 16, 1 : 2 : 4, Cement rendering etc. of size 4'-6" x 4'-6" complete in all respects. 1 Job
47 30 Providing and laying, jointing fixing and testing G.I. Pipe lines B-Class including cost of specials such as tees, bends,sockets, elbows etc. esting, cutting, threading Inside building complete.
48 30.01 15mm i/d 35 M
49 30.02 20mm i/d 60 M
50 31 Providing, fixing and jointing Union Couplings in G.I. Pipe lines.
51 31.01 15mm i/d G.I. Union 2 Each
52 31.02 20mm i/d G.I. Union 2 Each
53 32 Providing, fixing and jointing gun-metal peet valves (Heavy Pattern) with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.
54 32.01 20mm i/d Gun Metal peet valve heavy pattern. 3 Each
55 33 Providing & Fixing in position 15 mm i/d bib cock of approved make complete in all respect.
56 33.01 (i) C.P. brass Bib cock long nose / long body without flange 2 Each
57 33.02 (ii) C.P. brass Bib cock without flange 4 Each
58 34 Providing & Fixing in position stop cock / Angle valve of approved make complete in all respect.
59 34.01 (c) C.P. Brass 15 mm Angle valve without flange 12 Each
60 35 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.
61 35.01 (a) Size 75 mm x 75 mm 50 Rmt
62 36 Cutting holes up to 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.
63 36.01 (b) Through wall 22.86 cm thick 8 Each
64 37 Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
65 37.01 100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm 2 Each
66 38 Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification (IS:1729) of approved make of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required up to floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 150 mm with a minimum seal 50mm.
67 38.01 (a) With 75 mm i/d outlet deep seal 4 Each
68 39 Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drawings, including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 metre, for all works other than connections to complete in all respects.
69 39.01 For depths not exceeding 2.0 metre B.G.L.
70 39.02 For all classes of soil except rocky
71 39.03 110 mm i/d Sewer Line 10.8 Cum
72 39.04 90 mm i/d Sewer Line 8.1 Cum
73 40 Cement concrete 1:6:12 with Stone aggregate 40mm gauge.
74 40.01 For 110 mm i/d S.W. Pipe Sewer line (type-1) 15 mtr @ 0.125 cum/mtr length 1.88 Cum
75 41 Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge) including cutting, jointing, wastage, but excluding cost of lead jointing.
76 41.01 Type -A
77 41.02 110mm o/d SWR UPVC pipe line laid complete (ground+ vertical stack) 25 Mtr
78 41.03 90mm o/d SWR UPVC pipe line laid complete\n(ground+ vertical stack) 25 Mtr
79 42 Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
80 42.01 Door cap 3 Each
81 42.02 Single Junction With Door 3 Each
82 42.03 Single Junction Plain 1 Each
83 42.04 Bend With Door 3 Each
84 42.05 Bend Plain 3 Each
85 42.06 Cowl 3 Each
86 42.07 Reducer 110mm x 75mm 1 Each
87 42.08 Collar 2 Each
88 42.09 P Trap/Floor trap 110mm x110mm 3 Each
89 42.1 P Trap/floor trap 110mm x75mm 3 Each
90 42.11 Door cap 3 Each
91 42.12 Single junction with door 3 Each
92 42.13 Single junction plain 3 Each
93 42.14 Bend with door 3 Each
94 42.15 Bend plain 3 Each
95 42.16 Cowls 3 Each
96 42.17 Cross plain tee 3 Each
97 42.18 Collars 2 Each
98 42.19 Single Y-junction 2 Each
99 43 Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. 63.11 Sqm.
100 44 Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. 10 Sqm.
101 45 Dismantling Sanitary fixtures such as Eurpoean / Indian / Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge.
102 45.01 (a) Indian / Orissa W.C. 2 Each
103 45.02 (b) European W.C. 2 Each
104 45.03 (c) Wash Hand Basin / Urinal Pot / PVC / China Ware Cistern 2 Each
105 45.04 (d) Stainless Steel Sink 1 Each
106 45.05 (e) CP Bib Cock / Angle Cock / Stop Cock / Shower / Bottle Trap 6 Each
107 45.06 (g) Bathroom Assessories such as Soap Dish, Towel Rail, Towel Ring, Towel Bracket, Mirror, Toilet Paper Holder, Seat Cover, Jet Pressure and all other accessories. 3 Each
108 46 Providing and fixing in position best Indian make white ordinary lavatory suites consisting of C.P. brass waste 32mm dia, pair of angle iron bracket with one C.P. brass tap complete.
109 46.01 (ii) Size 550 mm x 400 mm 3 Each
110 47 Providing and fixing vitreous chinaware standard pedestal of approved make for wash hand basin complete in all respect. 3 Each
111 48 Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 3 Each
112 49 Extra for providing and fixing 10 litres capacity Chinaware low level flushing cistern with PVC internal fitting, instead of 10 litres capacity PVC flushing cistern. 3 Each
113 50 Extra for Providing and fixing C.P. brass 32 mm long bend complete 3 Each
114 51 Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P brass screws complete in all respect. 3 Each
115 52 Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect (as required by the Engineer-in- Charge)
116 52.01 (a) Size 600 mm x 450 mm 3 Each
117 53 Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. 12 Each
118 54 Providing and fixing jet spray with 2'-6" long PVC pipe. (a) With C.P. Brass nut 3 Each
119 55 Providing & Fixing in position C.P. Brass Hexa Nipple 15 mm of approved make (to the approval of Engineer-in-charge) complete in all respect. 12 Each
120 56 Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect. 12 Each
121 57 Providing & fixing in position best Indian make PVC flexible tube connection.
122 57.01 (c) PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut 9 Each
123 58 Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
124 58.01 Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal 3 Each
125 59 Extra for every 0.30 metre depth of inspection chamber.
126 59.01 450mm x 450mm inside 1 Each
127 60 Flooring and Wall Tiles & Misc. Works
128 60.01 Base course of floor consisting of 100 mm thick cement concrete 1:8:16 with stone aggreate and 100 mm sand filling.(using mechanical mixer for mixing of material) 548.9 Sqm.
129 61 Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base, including grouting the joints (Tiles to be laid with 2mm to 3 mm gap using spacers and later\nthis gap to be filled with cement based grout) with Cement base grout and matching pigments etc., complete. ( Division office + Sub Divisions) 527.9 Sqm.
130 62 Providing and laying Rectified Porcelain floor tiles 400 x 400 mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20 mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Fine sand) for new flooring complete Rectified tiles have finished edges allowing them to be placed closer together for a narrower grout joint as opposed to other tiles and are more expensive. Unlike typical factory-edged tile, rectified tile is cut to size after the firing process. ( for toilet area) 21 Sqm.
131 63 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm as\napproved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete 60 Sqm.
132 64 Black Granite stone tiles 15 to 20 mm thick in skirting, risers of steps dado, walls and pillars laid in 12.5 mm thick cement mortar 1:3 (1 cement, 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing & polishing including labour for fixing dowels, pins and cramps. 2.82 Sqm.
133 65 Providing and laying 50mm thick factoy made CC interlocking paver block of M-30 grade rubber moulded smooth finish with strong vibratory process and of aproved size and design/ shape laid in Dark fast colour and pattern over and including 50 mm thick compacted bed of coarse sand filling the joints with fine sand etc. all completes as per directions of Engineering charge. (Porch /Driveway) 326.77 Sqm.
134 66 Misc. works
135 66.01 Providing and fixing fibre sheet supported over M.S Angle iron of size 1.5"x1' making square box of 24"x24" with a support of MS Angle 3"x 1.5" and fixing of 3" dia M S Round pipes vertical for the support of the shed.Complete job including, nuts , washers , rivet work , gusset plates if any other structural member required , paint works etc to the entire satisfaction of Engineer in charge . 276.77 Sqm.
136 67 Renovation of existng Chowkidar room & Generating set having following works :-\n(area = 15'x10'=150 sqft+ 10' x 10' = 100 sft) = 250 sqft\na) repair of cracks, re plastering works whereever required\nb) paint polish work, \nc) repair of door and window works, glass panes, grilles etc\nd) repair of C.C flooring , \ne) electrical works and all other minor petty repair works etc. 1 LS
137 68 Replacement of existing broken AC sheet laid over existing Genset area and Chowkidar room with new Corrugated asbestos Sheet roofing 6 mm thick sheets fixed with GI hooks and bolts, limpet and bitumen washers complete fixed in position excluding the cost of erlins, rafters and trusses. 74.35 Sqmt.
138 69 Painting one coat with ready mixed paint of metallic surfaces in all shades on old steel or iron works. ( existing girders/ angles etc. 200 Sqmt.
139 70 Providing & Installing of furniture for office use
140 70.01 Chairs 10 Each
141 70.02 Tables 5 Each
142 70.03 Computer Tables 4 Each
143 70.04 Steel almirahs 6 Each
144 71 Providing Internal Electrical installations
145 71.01 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
146 71.02 Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge, uPVC, fire retardant conduit pipe 20mm/25mm dia. (2mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators, bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20Amp. Sockets and 6Amp./16/20Amp. Switches (Screw Type Modular Accessories) etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100watts, PVC connector (For Fan Box and Electronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) uPVC conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-\nMake :- PVC Insulated copper wire:- Finolex,, Polycab. RR Kabel, Havells, Ecko, Plaza, Anchor, KEI, HPL,\nAccessories:-North-West(Nova), Havell's (Crab Tree), Legrand (Myrius)
147 72 Wiring fan point with sheet metal fan box (shape hexagonal & sheet thickness not less than 1.60 mm) in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts. 9 Each
148 73 Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. 30 Each
149 74 Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade. 24 Each
150 75 Wiring 3 Pin 6 Amp. Plug control comprising wall socket (shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. 20 Each
151 76 Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch. 13 Each
152 77 Wiring call-bell point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer). 5 Each
153 78 Wiring TV sockets and Telephone socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases:-
154 78.01 Wiring Telephone socket point RJ11 (one module) 8 Each
155 79 PVC, HDPE PIPES & PVC FLEXIBLE PIPES:\nSupply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010:-\nMake:- Diplast/Canon/ AKG/ Poly India/ Polycab/ Ravindra/ Supreme
156 79.01 Heavy gauge PVC conduit pipe 20mm dia. (ISI marked 2 mm thick) Flushed 35 Each
157 79.02 Heavy gauge PVC conduit pipe 25mm dia. (ISI marked 2 mm thick) Flushed 35 Each
158 79.03 Heavy gauge PVC conduit pipe 40mm dia. (ISI marked 2 mm thick) Flushed 20 Each
159 79.04 Supply and erection of PVC flexible pipe complete with compression glands, having locking arrangement, check-nuts as required :-\nPVC flexible pipe 40mm dia. 20 Each
160 79.05 HEAVY GUAGE WELDED CONDUIT PIPES:\nSupply and erection of 20mm dia. heavy gauge welded conduit pipe (1.60mm thick) suspension rod for ceiling fan complete in all respect as desired by the Engineer-incharge. 23 Mtr
161 80 PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:
162 80.01 Supply and erection of PVC insulated single core FRLS copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing. Make:-Finolex/Polycab/ RR Kabel/ Havells/KEI
163 80.02 PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq.mm, 1100volts grade 90 Mtr
164 80.03 PVC insulated copper conductor single core FRLS cable (ISI marked) overall 2.5 sq.mm, 1100volts grade 80 Mtr
165 80.04 PVC insulated copper conductor single core FRLS cable (ISI marked) overall 4 sq.mm, 1100volts grade 100 Mtr
166 80.05 PVC insulated copper conductor single core FRLS cable (ISI marked) overall 10 sq.mm, 1100volts grade 100 Mtr
167 81 GALVANIZED IRON PIPES AND G.I. EARTHING :\nEarthing of Sheet metal/ iron clad switches and metallic cases etc., with 8 SWG (4mm dia.) electrolytic copper wire thimbled (with 1 nos. copper thimble) to 30 cm x 60 cm x 3 mm thick tinned copper plate (made cylindrical) burried 10 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) on wall and in floor etc., up to 13 metre in length (including bore length). G.I. pipe 20mm dia. (A-class) should be laid in the hole of excavation from bore surface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation. 2 Each
168 82 Supply and Erection of 8 SWG 4mm dia copper wire run through 20mm dia. Heavy guage welded conduit pipe (As additional length). 20 Mtr
169 83 SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):
170 83.01 Supply and erection of Switch Disconnector fuse unit with HRC Fuses in sheet enclosure on the existing surface (conforms to IS 13947 (PartI&III) complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connection on both sides of switch with sutiable size of Thimbles, including cost of HRC fuses as per PWD General Specifications (Electrical Works).
171 84 32Amp. 415volts three pole & neutral switch disconnector fuse unit with HRC Fuses in sheet enclosure 2 Each
172 85 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:\nSupply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.
173 85.01 GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA), HAGER
174 86 Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's/ RCBO/RCCB's for outgoing 8 way each 2 Each
175 87 GROUP-B: (Havell's, HPL, ABB, Standard & other brands approved by PWD)
176 87.01 MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:\nSupply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.\nGROUP-A: (Siemens (Beta Guard), Legrand (Lexic) & Schneider (Neo Break), L&T (Exora,Hager)
177 87.02 Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply 20 Each
178 87.03 Miniature circuit breaker four pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply 10 Each
179 88 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:\nSupply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size.\nMake : Duraline / Emtel
180 88.01 Double walled corrugated (DWC) HDPE pipe 63/ 51mm (outer/ inner dia.) 35 Mtr
181 89 Supply and erection of High quality aluminium extruded with decorative end caps glazed LED batten of Make Jaguar Item Code LGLZ01x020XC or Its equilant Make and Cat. of Philips / Wipro including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. 17 Each
182 90 S/E of Energy Saving Fan Ceiling Fans 1200 mm sweep ( 48" ) having two ball bearing but without regulator including flexible wire & petty material etc. for connections complete with erection, connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. Make :- Crompton Entrust 50-5 Star or its equillant make Havells ES-50 Premium 5 Star /Orient. 10 Each
183 91 Supply and erection of 12" Heavy Duty Exhaust fan (HDEF) (300mm-900RPM) Single Phase of make Crompton Model EXHD 300-6-1 or Its equialant Make Havell's Turbo Force SP / GE 151 marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections and louver shutter complete in all respectsas appd. and desired by the Engineer in-charge at site 10 Each
184 92 Supply and erection of Plastic Ventialtion Fan Ventilus 10" (250 mm - 900 RPM) single Phase of make Crompton , White Colour or Its equialant Make Havell's / GE including erection, connections and testing etc. complete with flexible wire and petty material regd. for connections and louver shutter complete in all respects as approved and desired by the Engineer in-charge at site 6 Each
185 93 Supply and erection of Wall fan of 400mm sweep (16") High Speed. Make Crompton WM Fizzair Opel White or Its equilant make Havell's / Orient ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections and Aluminium louver shutter complete in all respects as appd. and desired by the Engineer in-charge at site. 4 Each
186 94 Supply and erection of Glazed LED Batten Hgh Qualty Aluminium Extruded with decorative end caps of Make Jaguar Item Code LGLZ01X0410XC or Its equilant Make and Cat. of Philips / Wipro including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer In-charge at site. 27 Each
187 95 Supply & erection of Computer Terminal suitable for Computer Networking with modular accessories one on. metal box 12 module 8" x 6", 3 Nos. Switch 6 Amp, 3 Nos. Socket 3 pin 16 Amp, 1 No. Switch 20 Amp, 1 Nos. Socket 20 Amp and 1 No. Modular Accessories including connections & testing complete in all respect as desired by the Engineer-In-Charge at site. 18 Each
188 96 XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE IN THE EXISTING TRENCH OR PIPE):\nSupply and laying of XLPE/ P.V.C. insulated P.V.C. sheathed aluminium conductor un-armoured cable working voltage upto and including 1100 volts grade to be laid loose in the existing trench or pipe as per PWD General Specifications 2010:- Make:- Polycab, Havells, KEI,
189 97 XLPE/ PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100volts grade 25sq.mm (3 ½ Core) 35 Mtr
190 98 Supply & Erection of LED Street Light 45w in aluminium pressure Die Cast housing with touched glass cover (IP 66 protection ) of Make Jaguar Item Code LSR T 0150 4SxC or its equilant make and Cat Philips / Wipro / Halonix including erection of the same with the existing bracket fixed with pole, connections and testing etc. complete in all respects as aproved by the Engineer in charge at site. 4 Each
191 99 GI PIPE POLE BRACKETS:\nSINGLE ARM BRACKETS:\nSupply and erection of G.I. pipe 40mm dia. (A-class) single arm bracket atleast 1 metre long arm to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm with GI reducer 80mm x 40mm with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site. 6 Each
192 100 SUPPLY AND ERECTION OF WIRING ACCESSORIES:\nSupply and erection of switches, sockets, power switch and sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including connections and petty material etc.
193 100.01 Bakelite batten holder large size 35 Each
194 101 Providing and installing Eveporative Air Coolers (Desert Cooler) of Buleline make steel body complete with fan motor, Filter Pads, Water Pumps etc. complete in all respect 13 Each
195 102 CREDIT ON ACCOUNT OF OLD SCRAP MATERIAL i.e. Door and window frames , shutters, AC sheets etc. 1 LS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail