| 1 | 1 | Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete all as specified and directed. | | 550 | Sqm |
|---|
| 2 | 2 | M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. \nNote:- Liquid WPC will be measured and paid separately. | | 260 | Sqm |
|---|
| 3 | 3 | M&L for 10 mm thick cement plaster on fair faces of bricks/concrete surfaces with cement mortar 1:3 finished even and smooth (without using extra cement) complete on ceiling complete all as specified and directed. | | 150 | Sqm |
|---|
| 4 | 4 | M&L for 15 mm thick plastering in cm (1:6) finished even and smooth without using extra cement on bricks/concrete surfaces etc complete all as specified and directed | | 200 | Sqm |
|---|
| 5 | 5 | M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of Oil emulsion distemper over a coat of chalk whiting complete all as specified and directed. | | 200 | Sqm |
|---|
| 6 | 6 | M&L for prepration of newly plastered surfaces and applying three coats of white wash on wall surfaces complete all as specified and directed. | | 200 | Sqm |
|---|
| 7 | 7 | M&L for applying two coat of cement base paint on prepared new wall surfaces over a coat of primer on wall including preperation of new surfaces etc complete all as specified and directed. | | 240 | Sqm |
|---|
| 8 | 8 | M&L for three coats of white washing on new surfaces in ceiling incl preperation complete all as specified and directed. | | 150 | Sqm |
|---|
| 9 | 9 | M&L for preparing old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots and applying one coat of white wash complete all as specified and directed. | | 11500 | Sqm |
|---|
| 10 | 10 | M&L for preparing old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots and applying one coat of white wash complete all as specified and directed. | | 7000 | Sqm |
|---|
| 11 | 11 | M&L for preparing old decorated plastered or unplastered surfaces of walls any description by washing, rubbing down and applying one coat of cement paint complete all as specified and directed. | | 11600 | Sqm |
|---|
| 12 | 12 | M&L for preparing old decorated plastered or unplastered surfaces of walls any description by washing, rubbing down and applying one coat of distemper oil emulsion, white or tinted complete all as specified and directed.. | | 6000 | Sqm |
|---|
| 13 | 13 | M&L for preparing old decorated plastered or unplastered surfaces of ceiling any description by washing, rubbing down and applying one coat of distemper oil emulsion, white or tinted complete all as specified and directed. | | 600 | Sqm |
|---|
| 14 | 14 | M&L for preparing old painted surfaces of wood and wood based materials of any description not otherwise descriped over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | | 1975 | Sqm |
|---|
| 15 | 15 | M&L for preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | | 3000 | Sqm |
|---|
| 16 | 16 | M&L for writing letters or figures (Block Roman, Italic or Indian) not exceeding 30 cm heights with synthetic enamel paint complete all as specified and as directed. | | 15 | 10 Nos (Per CM of height) |
|---|
| 17 | 17 | M&L for rewriting stops, commas,short lines, dashes, hyphens, brackets etc with synthetic enamel paint complete all as specified and as directed. | | 5 | 10 Nos |
|---|
| 18 | 18 | M&L for preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of Aluminium Paint complete all as specified and directed. | | 15 | Sqm |
|---|
| 19 | 19 | M&L for cleaning of WCs and cleaning of sewage line from gully trap to 1st manholes day to day basis as per complaint slip on working day only by manually [a gang of 2 personnels (un skilled) including all necessary T&P] complete all as specified and directed .\nNote:- The attendance of labour shall be recorded in register daily and signed by contractor, JE (Civ) & Engineer-in-Charge for record of measurement. | | 290 | EACH |
|---|
| 20 | 20 | Desludging of septic tank including sludge pits etc manually for cleaning them throughly and removing muddy soils/sludge to a distance not exc 500mtr and buried it in pits or otherwise disposed off out side defence land including dewatering of efflorescents from septic tank, soak well etc by means of 7.5 HP non clogging diesel driven pump with necessary disel, T&P etc in nearest drain complete all as specified and directed for the following sizes:- | | | |
|---|
| 21 | 20.01 | 10 - 25 users septic tank | | 5 | EACH |
|---|
| 22 | 20.02 | 50 users septic tank | | 8 | EACH |
|---|
| 23 | 20.03 | 100 users septic tank | | 6 | EACH |
|---|
| 24 | 20.04 | 150 users septic tank | | 3 | EACH |
|---|
| 25 | 21 | ~Ditto~ all as per item No 20.00 mentioned above but man holes of any depth and any size. | | 120 | EACH |
|---|
| 26 | 22 | Cleaning of sewage line for 150 mm bore of pipes and connected manholes (any length) from manhole to manhole, manhole to septic tank septic tank to soakwell (length not exc 50 mtr) by roding and well flushing after cleaning and removing mud / sludge etc and burried it in pits and disposed off the same outside defence area complete all as specified and directed. | | 70 | EACH |
|---|
| 27 | 23 | Dewatering of efflorescents from septic tank / soak well etc of any capacity by means of 7.5 HP non clogging diesel driven pump with necessary diesel oil, T&P etc in nearest drain complete all as specified and directed.\nNote : Date and time of the dewatering shall be entered in register and signed by contractor, JE (Civil) and Engineer in charge for record of measurements. | | 12 | EACH |
|---|
| 28 | 24 | M&L for cleaning of sludge of any type from drain and clear to flow of water as directed including removing the excavated sludge n.exc. 50 m and depositing where directed at a level to a distance n.exc. 1.5 m above the starting points complete all as specified and directed. | | 60 | Cum |
|---|
| 29 | 25 | Cutting out any type of vegetation complete from root grouted inside the wall specially in contact with sanitary pipe and pouring/grounting with hydrochloric acid (HCL) on left out roots if any including making good surfaces to match adjacent surfaces in PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) or 15mm thick plaster in CM (1:4) area exc. 0.5 Sqm but n.exc. 1.0 Sqm each complete all as specified and directed. | | 200 | EACH |
|---|
| 30 | 26 | Cleaning and removing all scale and dirt, etc. from PVC water tanks of capacity exc 250 ltrs and not exc 500 ltrs and from mouths of circulating pipes, etc. complete all as specified and directed . | | 100 | Each |
|---|
| 31 | 27 | S&F in repair 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. | | 20 | EACH |
|---|
| 32 | 28 | S&F in repair 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. | | 10 | EACH |
|---|
| 33 | 29 | S&F in repair 110 mm bore PVC (SWR) branch piece , single (Single Y) equal or unequal complete all as specified and directed. | | 5 | EACH |
|---|
| 34 | 30 | S&F in repair 75 mm bore PVC (SWR) branch piece, single (Single Y) equal or unequal complete all as specified and directed. | | 5 | EACH |
|---|
| 35 | 31 | S&F in repair 110 mm bore PVC (SWR) junctions, single (Single T) equal or unequal complete all as specified and directed. | | 5 | EACH |
|---|
| 36 | 32 | S&F in repairs 110 mm bore PVC (SWR) vent cowl complete all as specified and directed. | | 5 | EACH |
|---|
| 37 | 33 | S&F in repair 75 mm bore PVC (SWR) vent cowl complete all as specified and directed . | | 10 | EACH |
|---|
| 38 | 34 | S&F in repair 110 / 110 mm bore PVC (SWR) 'P' trap complete all as specified and directed . | | 5 | EACH |
|---|
| 39 | 35 | S&F in repair 110 / 110 mm bore PVC (SWR) 'S' traps complete all as specified and directed. | | 10 | EACH |
|---|
| 40 | 36 | S&F in repair 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. | | 30 | EACH |
|---|
| 41 | 37 | S&F in repairs 75mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed .(Note : Earth work will be measured & paid separately | | 10 | RM |
|---|
| 42 | 38 | S&F in repairs 110mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. \nNote:- Earth work will be measured & paid separately | | 130 | RM |
|---|
| 43 | 39 | S&F in repairs 110mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, fixed to walls complete all as specified and directed. | | 75 | RM |
|---|
| 44 | 40 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed. | | 5 | Cum |
|---|
| 45 | 41 | Demolition of reinforcement cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. | | 3 | Cum |
|---|
| 46 | 42 | M&L for 100 mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) in floors complete all as specified and directed. | | 50 | Sqm |
|---|
| 47 | 43 | Demolition of brick work built in cement mortor including all quions arches pillar etc. but excluding concrete arches complete all as specified and directed. | | 6 | Cum |
|---|
| 48 | 44 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 and finished even and smooth (without using extra or cement) complete all as specified and directed. | | 75 | Sqm |
|---|
| 49 | 45 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc. or for shafts, cesspits, manholes, pier holes etc. n.exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in soft / loose soil complete all as specifed and directed. | | 8 | Cum |
|---|
| 50 | 46 | M&L for cement concrete bed to drain pipes in cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) including packing under and haunching against the sides of pipe 150 mm dia after they are laid and tested complete all as specified and directed. | | 60 | RM |
|---|
| 51 | 47 | Returning filling in, including spreading levelling watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specifed and directed. | | 6 | Cum |
|---|
| 52 | 48 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specifed and directed. | | 2 | Cum |
|---|
| 53 | 49 | M&L for providing cement concrete (1:4:8) type D-2 (using 40 mm graded stone agregate) as in foundation, filling and mass concrete complete all as specifed and directed. | | 3 | Cum |
|---|
| 54 | 50 | M&L for providing cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping, water toughs including weathering, slighting rounded or chamfered angles and throating including necessary form work all as directed and specified. | | 1 | Cum |
|---|
| 55 | 51 | M&L for precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in man hole cover slabs and set in CM (1:4) after demolition of existing man hole cover complete all as specifed and directed. | | 2 | Cum |
|---|
| 56 | 52 | M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specifed and directed. | | 5 | Cum |
|---|
| 57 | 53 | M&L for Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specifed and directed. | | 75 | Kg |
|---|
| 58 | 54 | M&L for Cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in surface channels and drains complete all as specifed and directed. | | 2 | Cum |
|---|
| 59 | 55 | Supply only integral water proofing compound (Liquid). | | 5 | Ltr |
|---|
| 60 | 56 | M&L in repair 75 mm dia of cast iron nahani trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed. | | 10 | EACH |
|---|
| 61 | 57 | S&F in repair vitreous china squatting pan, Orissa pattern size 580 x 440 mm white with integral foot rest incl connection to trap, and to flush pipe, anti-syphonage etc including making good to floor complete all as specifed and directed. | | 7 | EACH |
|---|
| 62 | 58 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including sheet cover of white colour complete all as specified and directed . | | 5 | EACH |
|---|
| 63 | 59 | M&L for cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) finish smooth and reforming benching as required for 150 mm internal dia of pipe complete all as specifed and directed. | | 5 | EACH |
|---|
| 64 | 60 | ~Ditto~ all as per item No 59.00 above mentioned but for 110/100/75 mm dia of pipe complete all as specifed and directed. | | 5 | EACH |
|---|