Power Development Department has published Annual Stage Contract Of 33/11 Kv Receiving Stations Falling Under The Jurisdiction Of Std I Bemina Srinagar Annual Stage Contract For Repair And Maintenance Of 33/11Kv Receiving Stations Falling Under The Jurisdiction Of Sub Transmission Division-I , Be. Submission Date for this Tender is 14-10-2020. Springs Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-Aug-2020 | Date Extention No 1 | Date | 26-08-2020 |
2 | 26-Aug-2020 | Extension No 02 | Date | 14-09-2020 |
3 | 15-Sep-2020 | Extension No 03 | Date | 28-09-2020 |
4 | 28-Sep-2020 | Extension No 04 | Date | 14-10-2020 |
Name of Work: Annual Stage Contract for "Repair & Maintenance of 33/11kV Receiving Station falling under the jurisdiction of Sub Transmission Division-Ist,Bemina,Srinagar for the year 2020-21 or till the next Stage Contract | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Annual Stage Contract for "Repair & Maintenance of 33/11kV Receiving Station falling under the jurisdiction of Sub Transmission Division-Ist,Bemina,Srinagar for the year 2020-21 or till the next Stage Contract.The Contract prices provided in the contract are deemed to be inclusive of all taxes like GST toll tax, labour cess etc and return of red material to divisional stores wherever applicable. | 1 | ||
2 | 2 | Installation testing and commissioning of switch gear system complete after dismantling the existing ones (material to be provided by the department) | 2 | ||
3 | 2.01 | 33 KV C&R panel Complete | 3 | 1 | Job |
4 | 2.02 | 33 KV VCB Complete | 4 | 1 | Job |
5 | 2.03 | 11 KV VCB complete | 5 | 1 | Job |
6 | 3 | Installation testing and commissioning of 33 KV CT in out door yard, including replacement of damaged one (Material to be supplied by the department) | 6 | 1 | Job |
7 | 4 | Installation testing and commissioning of 33 KV PT in out door yard including replacement of damaged one (Material to be supplied by the department) | 7 | 1 | Job |
8 | 5 | Installation testing and commissioning of 33 Vaccum Interupter in 33 KV VCBs including replacement of damaged one (Material to be supplied by the department) | 8 | 1 | Job |
9 | 6 | Installation testing and commissioning of 33 KV Lightening Arrestor in the yard including replacement of damaged one (Material to be supplied by the department) | 9 | 1 | Job |
10 | 7 | Replacement/ installation testing and commissioning of burnout buses and Clamps in 33 KV Yard | 10 | 1 | Job |
11 | 8 | Repair/Setting right of control wiring of the 33 KV VCB panels.(Material to be supplied by the department) | 11 | 1 | Job |
12 | 9 | Repair/Setting right of control wiring of the 11 KV VCB panels.(Material to be supplied by the department) | 12 | 1 | Job |
13 | 10 | Repairs of equipment earthing viz CTs, PTs, Transformer , LA etc. | 13 | 1 | Job |
14 | 11 | Fixing, Installation testing and commisioning of :- | 14 | ||
15 | 11.01 | 33 KV Bushes and Bush Rods of power transformer(Material to be supplied by the department) | 15 | 1 | Job |
16 | 11.02 | 11 KV Bushes and Bush Rods of power transformers.(Material to be supplied by the department) | 16 | 1 | Job |
17 | 12 | Plugging oil leakage of Power Transformer from :- | 17 | ||
18 | 12.01 | Main Tank leakage. | 18 | 1 | Job |
19 | 12.02 | Radiator leakage. | 19 | 1 | Job |
20 | 12.03 | Conservator/ OLTC tank leakage. | 20 | 1 | Job |
21 | 13 | Providing fixing installation testing and commissioning of following by way of replacement of damaged one, suitable for 33/11 KV, 10/6.3/5 MVA power transformers | 21 | ||
22 | 13.01 | WTI (WTM) | 22 | 1 | Job |
23 | 13.02 | OTI (WTM) | 23 | 1 | Job |
24 | 14 | Providing fixing installation testing and commissionig of 11 KV Panel bushes(Spouts) and dismantling of the damaged one. | 24 | 1 | Job |
25 | 15 | Providng Fixing installation testing and commisioning of lugs /thimbles, CT bushes and cleaning thereof. | 25 | 1 | Job |
26 | 16 | Providng Fixing installation testing and commisioning of Breather along with silica jel for Power Transformer | 26 | 1 | Job |
27 | 17 | Fixing, Testing & Commissioning of fresh 11 KV PT Set after replacement of damaged one (Material to be supplied by the department) | 27 | 1 | Job |
28 | 18 | Installation testing and commissioning of 11 KV LA after replacement of damaged one (Material to be supplied by the department) | 28 | 1 | Job |
29 | 19 | Fixing, Testing & Commissioning of fresh 11kV CT after replacement of damaged / burnt out 11kV CT.(materal to be supplied by the department) | 29 | 1 | Job |
30 | 20 | Fixing, Testing & Commissioning of fresh 11kV Vacuum Interruptor after replacement of damaged 11kV Vacuum Interruptor .(materal to be supplied by the department) | 30 | 1 | Job |
31 | 21 | Fixing, Testing & Commissioning of fresh Numerical / Digital Relay in place of damaged /obsolute relay or digital relay (materal to be supplied by the department) | 31 | 1 | Job |
32 | 22 | General overhauling of the 11 KV VCB which includes providing, rectification and setting right of multiple damaged mechanical parts with subsequent installation testing and commissioning and loading/unloading at site and carriage upto work place. | 32 | 1 | Job |
33 | 23 | Providing,Rectification and setting right Electrical section and wiring of 11kV Breakers with replacement of mutiple damaged Electrical parts. | 33 | 1 | Job |
34 | 24 | Providing,Rectification and setting right of mutiple damaged Mechanical parts of 11kV VCB { like charging/discharging spring, drum,, Gears, Rods etc}. | 34 | 1 | Job |
35 | 25 | Providing and Fixing of Following for 11kV Switchgear Panel:- | 35 | ||
36 | 25.01 | Auxillary Switch of 11kV VCB. | 36 | 1 | Job |
37 | 25.02 | Switch(Close/Trip) | 37 | 1 | Job |
38 | 25.03 | LED Indicators of 11kV panels | 38 | 1 | Job |
39 | 25.04 | Alarm bells | 39 | 1 | Job |
40 | 25.05 | Tripping coil / Closing Coil of 11kV VCB. | 40 | 1 | Job |
41 | 26 | General overhauling of the 33 KV VCB which includes providing, rectification of and setting right of multiple damaged mechanical parts with subsequent testing and commissioning. | 41 | 1 | Job |
42 | 27 | Providing,Rectification and setting right Electrical section and wiring of 33kV Breakers with replacement of mutiple damaged Electrical parts. | 42 | 1 | Job |
43 | 28 | Providing,Rectification and setting right of mutiple damaged Mechanical parts of 33kV VCB { like charging/discharging spring, drum,, Gears, Rods etc}. | 43 | 1 | Job |
44 | 29 | Providing Fixing testing Commissioning of Master Relays. | 44 | 1 | Job |
45 | 30 | Providing Fixing, testing & commissioning of copper bus bar (2'x10mm) for coupling of 11kV Panels. | 45 | 1 | Job |
46 | 31 | Laying, Testing & Commissioning of 11kV (E) grade armoured, 3-Core XLPE Power Cable of follwing sizes, (materal to be supplied by the department) | 46 | ||
47 | 31.01 | 185 mm2 | 47 | 1 | Job |
48 | 31.02 | 240 mm2 | 48 | 1 | Job |
49 | 31.03 | 300 mm2 | 49 | 1 | Job |
50 | 31.04 | 400 mm2 | 50 | 1 | Job |
51 | 32 | Fixing, testing & commissioning of 11kV (3)- Core Cable end kits INDOOR/OUTDOOR TYPE 3M or equivalent (materal to be supplied by the department) suitable for:- 3-Core, 400mm2, 3-Core, 400mm2, 3-Core, 240mm2 and 3-Core, 185mm2. | 51 | 1 | Job |
52 | 33 | Laying, Testing & Commissioning of 11kV (E) grade armoured, 1-Core XLPE Power Cable of follwing sizes, (materal to be supplied by the department) Core, 630nn2, 400mm2 , 300mm2 and , 240mm2 ,185 mm | 52 | ||
53 | 33.01 | 630 mm2 | 53 | 1 | Job |
54 | 33.02 | 400 mm2 | 54 | 1 | Job |
55 | 33.03 | 300 mm2 | 55 | 1 | Job |
56 | 34 | Fixing, testing & commissioning of 11kV Single Core Cable end kits INDOOR/OUTDOOR TYPE 3M or equivalent (materal to be supplied by the department) suitable for:- 3-Core, 400mm2,i. 3-Core, 400mm2, 3-Core, 240mm2 and 3-Core, 185mm2 | 56 | 1 | Job |
57 | 35 | Laying testing and commissioning of 2.5 mm2 , 2/4/6/8/12/16 core control cable armoured copper conductor sheathed PVC insulated multi colur voltage grade 1.1 KV . | 57 | 1 | Job |
58 | 36 | Oil Topping of Power Transformer / CT / PT(materal to be supplied by the department) | 58 | 1 | Job |
59 | 37 | Installation /testing/commissioning of 36 V Battery Bank (materal to be supplied by the department) | 59 | 1 | Job |
60 | 38 | Installation /testing/commissioning of 33 KV Isolator, 1250 Amps heavy duty (wth and witout EB) materal to be supplied by the department | 60 | 1 | Job |
61 | 39 | Installation /testing/commissioning of 11 KV Isolator, 400 Amps heavy duty (with and witout EB) materal to be supplied by the department | 61 | 1 | Job |
62 | 40 | Repairing of 33 KV Isolator viz replacing Copper Male/female contacts, conductor clamps etc (materal to be supplied by the department) | 62 | 1 | Job |
63 | 41 | Fixing, Testing & Commissioning of fresh 11kV Link sets (materal to be supplied by the department) | 63 | 1 | Job |
64 | 42 | Deweeding of out door yard. | 64 | 1 | sft |