Military Engineer Services-MES has published Repair/Maintenance Of Earth Pits , Lightning Conductor , Street Lights , Dg Sets , Amf Panel , Lt Panel , Underground Cable And Connected Item ( S ) Of Work At Af Stn Darbhanaga Under Ge ( Af ) Bihta. Submission Date for this Tender is 04-08-2020. Conductor Tenders in Darbhanga Bihar. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Jul-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-08-2020 |
Name of Work :Repair/Maintenance of existing earth pits,lighting conductor,DG set, AMF panel,LT panel,UG cables,street lights, and connecting work at AF Stn Darbhanga | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Overhauling/servicing oil sump of 10 Kva DG Sets , turbochargers, self starter motor, rectfication of oil and leakage from turbocharge refilling new oil as per is stander and testing complete, cleaning, removing sediments/foriegn particles from the complete oil circulation system, refixing, incl replacing oil sump gasket , fillter all (oil filtter,air filtter,and testing for fuel pipeline PVC connection with new highly transperent PVC flexible pipes of suitable diameter, painting of outer surfaces of fuel tank Check, clean, adjust/tighten, grease and set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head incl decarbonising electrical wirings all bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, coupling, alternator terminals, carbons brushes, springs, AVR's, exhause pipes etc of following DG Sets complete test DG set after fixing all items in load as per directed by Engineer-in-Charge:-:- | 3 | job | |
2 | 1.01 | 1. Fuel Pump service | 2 | Nos | |
3 | 1.02 | 2. Fuel injector service | 2 | Nos | |
4 | 1.03 | 3. Self starter repair | 2 | Nos | |
5 | 1.04 | Parts(a) Engine oil 7.5 Ltrs | 15 | LTR | |
6 | 1.05 | (b) Air filter | 2 | Nos | |
7 | 1.06 | ( c) Diesel Filter | 2 | Nos | |
8 | 1.07 | (d) Mobil filter | 2 | Nos | |
9 | 1.08 | (e) painting | 2 | Nos | |
10 | 1.09 | (f) coolent | 8 | LTR | |
11 | 1.1 | (g) batrry 80 Amps Black | 2 | Nos | |
12 | 2 | Overhauling/servicing oil sump of 62.5/50 Kva DG Sets, turbochargers, self starter motor, rectfication of oil and leakage from turbocharge refilling new oil as per is stander and testing complete, cleaning, removing sediments/foriegn particles from the complete oil circulation system, refixing, incl replacing oil sump gasket , fillter all (oil filtter,air filtter,and testing for fuel pipeline PVC connection with new highly transperent PVC flexible pipes of suitable diameter, painting of outer surfaces of fuel tank Check, clean, adjust/tighten, grease and set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head incl decarbonising electrical wirings all bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, coupling, alternator terminals, carbons brushes, springs, AVR's, exhause pipes etc of following DG Sets complete test DG set after fixing all items in load as directed by Engineer-in-Charge:-:- | 3 | JOB | |
13 | 2.01 | 1. Radiater Repair | 2 | Nos | |
14 | 2.02 | 2. Main alterneter service and varnish | 2 | Nos | |
15 | 2.03 | 3. Charging alterneter service | 2 | Nos | |
16 | 2.04 | 4. Turbo charger service | 2 | Nos | |
17 | 2.05 | 5. Fuel pump service | 2 | Nos | |
18 | 2.06 | 6. Fuel injecter service | 2 | Nos | |
19 | 2.07 | 7. self starter repair | 2 | Nos | |
20 | 2.08 | Parts (a) Engine oil 13.5 Ltrs | 27 | LTR | |
21 | 2.09 | (b) Air filter | 2 | Nos | |
22 | 2.1 | ( c) Diesel Filter | 4 | Nos | |
23 | 2.11 | (d) Mobil filter | 2 | Nos | |
24 | 2.12 | ( e) Coolant | 6 | LTR | |
25 | 2.13 | (f) Battry 130 Amps Black | 2 | Nos | |
26 | 2.14 | (g) door kabza | 2 | Nos | |
27 | 2.15 | (i) door Lock | 2 | Nos | |
28 | 2.16 | (j) V belt | 2 | Nos | |
29 | 3 | M&L for removing US absestos rope and S/F new absestos rope 12mm dia wound spirally around exhaust pipe of DG sets all as specified and directed. | 20 | Kg | |
30 | 4 | Dismanting overhauling/servicing existing unserviceable AVR of the alternator of S&F new AVR of same capacity/model/type incl connecting up and testing and battriy charger assembly (a) 62.5 KVA capacity | 2 | Each | |
31 | 4.01 | (b) 10 KVA capacity | 2 | Each | |
32 | 5 | Rep/Maintenance and complete overhauling of AMF panel upto 62.5 KVA/10 kva and supply in repair Micro controller based AMF relay unit (GCU) complete with all accessories including new follwoing items supply , disconnecting the existing unserviceable three phase unit and existing connections and re-fixing the connections to the new unit, testing and setting the timing, voltages low oil temp, low battery eingin file to strat etc, making the AMF panel tuned with the D.G. set etc complete all as specified and directed by Engineer-in-Charge. 1. battry charger change 2. timer chenge controal dg set on-off 3. contactor | 2 | job | |
33 | 6 | S&F in repair Power Contactor 4P 125 A, with NO NC contacts for AMF panel upto 62.5 KVA including disconnecting the existing unserviceable contactor and connecting the new unit, testing complete all as specified and directed by Engineer-in-Charge. Make: HPL or equivalent in specified makes. | 3 | Each | |
34 | 7 | S&F in repair Power Contactor 4P 63A, with NO NC contacts for AMF panel upto 50 KVA including disconnecting the existing unserviceable contactor and connecting the new unit, testing complete all as specified and directed by Engineer-in-Charge. Make: HPL or equivalent in specified makes. | 3 | Each | |
35 | 8 | Supply and fix in repair MCCB 4 pole, 415 V, adjustable type100 Amp with braking capacity 16KA . (Make : Havells Cat No IHLASF0100 or equivalent and approved model of L&T/MDS/Scheineder) | 3 | Each | |
36 | 9 | Supply and fix in repair MCCB 4 pole, 415 V, adjustable type63 Amp with braking capacity 16KA . (Make : Havells Cat No IHLASF0630 or equivalent and approved model of L&T/MDS/Scheineder) | 3 | Each | |
37 | 10 | S & F in repair change over switch in steel sheet enclosure with side of handle 100 Amps type(SCHS), 415 V AC 50 HZ, four poles. (Make " Havells cat No : IHBFFE0100 or equivelant model of L&T /Stnadard) | 3 | Each | |
38 | 11 | S & F in repair change over switch in steel sheet enclosure with side of handle 63 Amps type(SCHS), 415 V AC 50 HZ, four poles. (Make " Havells cat No : IHBFFE063 or equivelant model of L&T /Stnadard) | 3 | Each | |
39 | 12 | S & F in repair change over switch in steel sheet enclosure with side of handle 40 Amps type(SCHS), 415 V AC 50 HZ, four poles. (Make " Havells IHCNFE0040 or equivelant model of L&T /Stnadard) | 3 | Each | |
40 | 13 | Supply and fixing in repair for contactor 40 amp cn695f 4 Pole with NO/NC relay along with wire for connection complete all as specified and directed by Eng-in-charge.Make L&T/Havells | 4 | Each | |
41 | 14 | S & F in repair change over switch in steel sheet enclosure with side of handle 32 Amps type(SCHS), 415 V AC 50 HZ, four poles. (Make " Havells IHBFFE032 or equivelant model of L&T /Stnadard) | 1 | Each | |
42 | 15 | Supply and fixing in repair driver for flood light LED fitting 80/60 W of any company complete all as directed .Make-Havells/Philips/Crompton | 24 | Each | |
43 | 16 | Supply and fixing in repair driver for securty light LED fitting 45/72 W of any company complete all as directed .Make-Wipro/Philips/Crompton | 65 | Each | |
44 | 17 | Supply and fixing in repairPCB for securty light LED fitting 45/72 W of any company complete all as directed .Make-Wipro/Philips/Crompton | 45 | Each | |
45 | 18 | Supply and fixing digital astronomical timer along with relay for automatic on/off fuctioning of high mast along the year complete with all accessories as directed .Make Havells cat pat No 67DDTO | 2 | Each | |
46 | 19 | Supply and fixing in repair driver for post top LED light fitting 40 W complete all as directed .Make:CG Cat S0DQL-54-700-40W | 4 | Each | |
47 | 20 | Material and labour for stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 complete all as specified and directed. (Note : excavation and concrete shall be measured separately) | 6 | Per Set | |
48 | 21 | Supply and fix in repair ammeter with selector switch 96 x 96mm size and 3 Nos of CT coils 0 to 200 Amp capacity complete all as directed. | 3 | Set | |
49 | 22 | Supply and fix in repair voltmeter with selector switch 96 x 96mm size 0 to 500 volts capacity all as directed. | 3 | Set | |
50 | 23 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 25x4mm, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ | 13 | Job | |
51 | 24 | All as per item No 23.00 here-in-before but GI wire size 4mm dia | 13 | job | |
52 | 25 | Repair/replacement for brazing of earth continuity conductor or main earthing lead 25mm X 3mm, aluminum strip/earth lead, in any position including jointing by existing tinned copper/brass nuts, bolts and washers complete all as specified & directed. \nNote:-\n(i) Each joint shall be considered for measurement purpose.\n(ii) Existing nut bolts & washers shall be reused for jointing of strips.\n(iii) Brazing shall be done with gas welding using brass electrode.\n | 230 | RM | |
53 | 26 | S&F 40 mm dia GI tubing , light grade for protection of strip passing across the road, wall under floor etc complete all as specified and directed. | 120 | RM | |
54 | 27 | Reparing of existing damaged earthing pit and exstantion hight of the above ground level 9'' construction of brick masonary earthing pit chamber canectivity of earthing to earthing pit and earthing concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 including earth work as required complete | 25 | Nos | |
55 | 28 | Repair /repleacment earthing pit cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, | 10 | Nos | |
56 | 29 | S & F Lightning arresters suitable for 11000 Volts, non-linear type complete with all fittings, transmission class, dischange capacity 65 KA | 3 | Per Set of 3 Nos | |
57 | 30 | Taking out old unserviceable cable from tenches/pole etc | 1100 | RM | |
58 | 31 | Supply and laying XLPE insulated, armoured heavy duty electric under ground cable with aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core complete all as specified and directed by Engineer-in-Charge. | 150 | RM | |
59 | 32 | All as per item No 31.00 here-in-before but of cross sectional area 25 Sqmm 4 Core. | 350 | RM | |
60 | 33 | All as per item No 31.00 here-in-before but of cross sectional area 50 Sqmm 3.5 Core. | 300 | RM | |
61 | 34 | All as per item No 31.00 here-in-before but of cross sectional area 95 Sqmm 3.5 Core. | 300 | RM | |
62 | 35 | Excavation In trenches not exceeding 1.5 mtr. In depth and not exceeding 1.5 mtr. In width and getting out in soft/loose soil for laying of cables/pipes, erection of poles, stays, cable fault detection etc. | 225.8 | Cu.m | |
63 | 36 | Returning re-filling of excavated soil after laying the cable with spreading leveling watering with ramming in layers not exceeding 25cm thick in loose/soft soil complete all as directed. | 127.3 | Cu.m | |
64 | 37 | Removing excavated materials/ surplus soil and depositing where directed at a distence not exceeding 50 mtr.at a level not exceeding 1.5 mtr. from starting point. | 131.5 | Cu.m | |
65 | 38 | Supply , lay / spread in trenches, River sand , clean ,including spreading , levelling , punning for laying / cushioning of cables all as specified and as directed. | 67.2 | Cu.m | |
66 | 39 | M&L well burnt sub class “B” bricks laid flat breadth wise along the length of cable for cable protection complete all as specified and directed. | 7.06 | Per 1000 Nos. | |
67 | 40 | M&L for cleaning and preperation of surfaces, by scrubbing with wire brushes, emery papers etc., from all metalic surfaces of MS tubular LT electric poles , any type / model, not more than 9 mtr. long above ground level , including cross arms, clamps etc., any size , on the same pole applying one coat of aluminium paint on pole,cross arms, clamps, GI pipes brackets etc., including writting of pole number etc., by paint all as specified and as directed. | 60 | Each | |
68 | 41 | Supply and fixing HT 185 sqmm Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armored aluminum cable. | 2 | Each | |
69 | 42 | Dismantling of old unserviceable Steel tubular pole 9.00 metre long and removing from site complete all as specified and directed. | 2 | Each | |
70 | 43 | Supply and erection of steel tubular swaged pole 9.0mtr long complete with cast iron base plate , finial taper plug, bolts, nuts & screws as specified type 410 SP-31 in true vertical position, including providing blue and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the copping of pole starting with blue strip including shifting of existing conductor, D clamps and other items from old pole to new pole complete all as specified and as directed by Engr-in-Charge. (Earth work and PCC shall be measured and paid separtely) | 2 | Each | |
71 | 44 | M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc compete all as specified and directed. | 6 | Cum | |
72 | 45 | M&L for PCC 1:3:6 type C-2 using 20mm graded aggregate mechanically crushed stone for mass filling in stay pits and pole foundation all as specified. | 7 | Cum | |
73 | 46 | Supply ,installation, testing and commissioning of LT control panel out door , factory made pedastal type fabricated out of 3.15 mm CRCA sheet having inner sheet of MS black and slopy roof , spray painting two coat inside and outside with synthetik enamle paint of approved shade over a coat of red oxide primer complete with locking arrangement, provision of cable gland for all incoming and outgoing cable , grouting of feeder piller box 30 cm above ground level by providing 45 cm long angle iron of size 40x40x6 mm welded on all the for corner embeded in PCC 1:2:4 using 20 mm stone agregrate up to 30 cm deep complete including coprising the following component including taking out the old panel :- (a) MCCB 4 Pole 440 Volt 250 Amp, 25 KA – 01 No (b) MCCB 3 Pole 440 Volt 123 Amp – 04 Nos (d) MCCB 3 Pole 440 Volt 63 Amp – 02 (e) MCB SPN 220 Volt 40 Amp – 02 Nos (e) LED type indecator lamp (green /red)- 01 set Make of MCBs/MCCBs- LEGRAND /\nL & T/SCHNEIDER/ABB | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy