| 1 | 1 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, for laying/taking out CI/GI pip lines, valves, etc and getting out in any type of soil complete all as specified and directed. | | 400 | CUM |
|---|
| 2 | 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. | | 360 | CUM |
|---|
| 3 | 3 | Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | | 40 | CUM |
|---|
| 4 | 4 | Taking up / down existing, cast iron pipe lines / water mains of any description / grade and in position including fittings, accessories and fixtures etc existing in between pipe line, by taking out and opening any type of joints (Tyton /Gasket / Lead joints) complete all as specified and directed by the Engineer-in-Charge for following bore of pipes:- \nNOTE : \n(i) While taking out of water main existing lead shall be recovered by burning out joints carefully from the existing joints of the water mains which shall be sold to the contractor under schedule of credit\n(ii) Old CI pipe / fittings retrieved in serviceable condition from taking down shall be reused in the work as approved by the Engineer-in-Charge.\n | | | |
|---|
| 5 | 4.1 | 80mm bore | | 50 | RM |
|---|
| 6 | 4.2 | 100 mm bore | | 100 | RM |
|---|
| 7 | 4.3 | 150 mm bore | | 100 | RM |
|---|
| 8 | 4.4 | 200 mm bore | | 50 | RM |
|---|
| 9 | 4.5 | 250mm bore | | 20 | RM |
|---|
| 10 | 4.6 | 450mm bore | | 11 | RM |
|---|
| 11 | 5 | Laying only in trenches, spigot and socketed cast iron pipes of any description / grade and in any position, as obtained from taking up or down, after making necessary addition / alterations and properly cleaning the pipes internally and externally, drawing out foregin material/rust, etc for the following sizes complete all as specified and directed :- \nNOTE:-\n(i) Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item of BOQ/Schedule `A'.\n(ii) Old CI pipe / fittings retrieved in serviceable condition from taking down shall be reused in the work after proper cleaning(externally & internally) .\n | | | |
|---|
| 12 | 5.1 | 80mm bore | | 40 | RM |
|---|
| 13 | 5.2 | 100 mm bore | | 70 | RM |
|---|
| 14 | 5.3 | 150 mm bore | | 70 | RM |
|---|
| 15 | 5.4 | 200 mm bore | | 30 | RM |
|---|
| 16 | 5.5 | 250mm bore | | 11 | RM |
|---|
| 17 | 5.6 | 450mm bore | | 11 | RM |
|---|
| 18 | 6 | S&F cast iron pipes with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches for the following sizes complete all as specified and directed :- [MAKE:-ELECTROSTEEL / KAPILANSH / NECO / KEJRIWAL as approved by GE]\nNOTE :- Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item of BOQ/Schedule `A'. | | | |
|---|
| 19 | 6.1 | 80mm bore | | 10 | RM |
|---|
| 20 | 6.2 | 100 mm bore | | 30 | RM |
|---|
| 21 | 6.3 | 150 mm bore | | 30 | RM |
|---|
| 22 | 6.4 | 200 mm bore | | 20 | RM |
|---|
| 23 | 6.5 | 250mm bore | | 9 | RM |
|---|
| 24 | 7 | M&L for push on flexible rubber gasket (Tyton) joint suitable for ductile iron pressure pipes for water mains and pipe fittings with spigot and socketed ends for the following sizes complete all as specified and directed :- | | | |
|---|
| 25 | 7.1 | 80mm bore | | 5 | EACH |
|---|
| 26 | 7.2 | 100 mm bore | | 5 | EACH |
|---|
| 27 | 7.3 | 150 mm bore | | 5 | EACH |
|---|
| 28 | 8 | Cutting cast iron pipes in position for insertion of new tees, branches, etc for the following sizes complete all as specified and directed :- | | | |
|---|
| 29 | 8.1 | 80mm bore | | 6 | EACH |
|---|
| 30 | 8.2 | 100 mm bore | | 6 | EACH |
|---|
| 31 | 8.3 | 150 mm bore | | 6 | EACH |
|---|
| 32 | 8.4 | 200 mm bore | | 3 | EACH |
|---|
| 33 | 8.5 | 250mm bore | | 3 | EACH |
|---|
| 34 | 8.6 | 450mm bore | | 3 | EACH |
|---|
| 35 | 9 | S&F cast iron bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, ‘Y’ junction, double branch, cross (all sockets or socket & spigot or flanged) collars, caps and plugs for spigot socketed pipes upto 150mm bore complete all as specified and directed. \n[MAKE:-ELECTROSTEEL / KAPILANSH / NECO / KEJRIWAL as approved by GE] | | 200 | KG |
|---|
| 36 | 10 | S&F cast iron bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, ‘Y’ junction, double branch, cross (all sockets or socket & spigot or flanged) collars, caps and plugs for spigot socketed pipes 200mm to 450mm bore complete all as specified and directed. \n[MAKE:-ELECTROSTEEL / KAPILANSH / NECO / KEJRIWAL as approved by GE] | | 250 | KG |
|---|
| 37 | 11 | M&L for Run lead joint for cast iron spigot and socket pipes and fitting for the following bores complete all as specified and directed :- | | | |
|---|
| 38 | 11.1 | 80mm bore | | 25 | EACH |
|---|
| 39 | 11.2 | 100 mm bore | | 25 | EACH |
|---|
| 40 | 11.3 | 150 mm bore | | 30 | EACH |
|---|
| 41 | 11.4 | 200 mm bore | | 20 | EACH |
|---|
| 42 | 11.5 | 250mm bore | | 20 | EACH |
|---|
| 43 | 11.6 | 450mm bore | | 20 | EACH |
|---|
| 44 | 12 | M&L for caulking of run lead joint for spigot and socketed pipes and fittings using lead wool including necessary excavation, returning & refilling for the following bores complete all as specified and directed :-\nNOTE:- The quoted rates for above items is inclusive of lead wool, necessary earth work in excavation and dewatering of trenches, etc. | | | |
|---|
| 45 | 12.1 | 80mm bore | | 4 | EACH |
|---|
| 46 | 12.2 | 100 mm bore | | 4 | EACH |
|---|
| 47 | 12.3 | 150 mm bore | | 4 | EACH |
|---|
| 48 | 12.4 | 200 mm bore | | 4 | EACH |
|---|
| 49 | 12.5 | 250mm bore | | 4 | EACH |
|---|
| 50 | 12.6 | 450mm bore | | 4 | EACH |
|---|
| 51 | 13 | Taking out sluice valve top cover, spindle and broken / unsv check nut (gutka); removal to workshop & refixing of sluice valve parts after servicing / maintenance /grinding / cleaning / threading / greasing work to sluice valve parts, including replacment of gland packing, rubber sheet, nuts, bolts, spindle, check nut and washer, etc as required; and reassembling the sluice valve and testing complete all as specified and directed of following size:-\nNOTE :- Replacement of the spindle shall be measured and paid for separately. | | | |
|---|
| 52 | 13.1 | 80mm bore | | 1 | EACH JOB |
|---|
| 53 | 13.2 | 100 mm bore | | 1 | EACH JOB |
|---|
| 54 | 13.3 | 150 mm bore | | 1 | EACH JOB |
|---|
| 55 | 13.4 | 200 mm bore | | 1 | EACH JOB |
|---|
| 56 | 13.5 | 250mm bore | | 1 | EACH JOB |
|---|
| 57 | 13.6 | 450mm bore | | 1 | EACH JOB |
|---|
| 58 | 14 | Taking out old unserviceable Sluice valve and Supply, installation, fixing, jointing and testing, of approved quality cast iron flanged sluice valve of class 1.6 PN, long body, ISI marked (IS-14846) with stainless steel spindle and hand wheel including nuts, bolts, rubber gasket, etc complete of following size:- [MAKE:- KIRLOSKAR / LEADER / L&T as approved by GE] | | | |
|---|
| 59 | 14.1 | 80mm bore | | 2 | EACH |
|---|
| 60 | 14.2 | 100 mm bore | | 2 | EACH |
|---|
| 61 | 14.3 | 150 mm bore | | 2 | EACH |
|---|
| 62 | 14.4 | 200 mm bore | | 2 | EACH |
|---|
| 63 | 14.5 | 250mm bore | | 3 | EACH |
|---|
| 64 | 15 | M&L for replacment of stainless steel splindle with check nut of existing type & size, including opening, grinding , threading , machning of gun metal gate, replacement of nut, bolt and washer including rubber sheet suitable for the following sizes of sluice valves of any description complete all as specified and directed:- \n | | | |
|---|
| 65 | 15.1 | 80mm bore | | 1 | EACH |
|---|
| 66 | 15.2 | 100 mm bore | | 1 | EACH |
|---|
| 67 | 15.3 | 150 mm bore | | 1 | EACH |
|---|
| 68 | 15.4 | 200 mm bore | | 1 | EACH |
|---|
| 69 | 15.5 | 250mm bore | | 1 | EACH |
|---|
| 70 | 16 | M&L for Brick work with sub class ‘B’ bricks (Modular), straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 including demolition of old brickwork where ever required complete all as specified and directed. | | 5 | CUM |
|---|
| 71 | 17 | M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work including demolition of old/loose concrete wherever required complete all as specified and directed. | | 3 | CUM |
|---|
| 72 | 18 | M&L for rendering 15mm thick in cement mortar 1: 4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. | | 20 | SQM |
|---|
| 73 | 19 | S&F Rolled mild steel sections conforming to Fe 410-W (Gde E-250) quality -A as in valve pit chamber cover made of MS equal angle and MS sheet 3 mm thick including welding, cutting, hinges, locking arrangments, etc including taking out old rusted covers complete all as specified and directed. | | 50 | KG |
|---|
| 74 | 20 | Taking up or down steel tubing and connections from trenches / walls / floors / ceilings, etc including cleaning (tubings only and not connections) for refixing for the following sizes complete all as specified and directed :- \n | | | |
|---|
| 75 | 20.1 | 80 mm bore | | 200 | RM |
|---|
| 76 | 20.2 | 50 mm bore | | 250 | RM |
|---|
| 77 | 20.3 | 40mm bore | | 200 | RM |
|---|
| 78 | 20.4 | 25mm bore | | 200 | RM |
|---|
| 79 | 20.5 | 20mm bore | | 500 | RM |
|---|
| 80 | 20.6 | 15mm bore | | 300 | RM |
|---|
| 81 | 21 | Refixing old steel tubing with and provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc) for the following sizes complete all as specified and directed :- | | | |
|---|
| 82 | 21.1 | 80 mm bore | | 70 | RM |
|---|
| 83 | 21.2 | 50 mm bore | | 80 | RM |
|---|
| 84 | 21.3 | 40mm bore | | 90 | RM |
|---|
| 85 | 21.4 | 25mm bore | | 80 | RM |
|---|
| 86 | 21.5 | 20mm bore | | 150 | RM |
|---|
| 87 | 21.6 | 15mm bore | | 75 | RM |
|---|
| 88 | 22 | S&F Steel water tubes, medium grade, ISI marked, galvanised with all fittings, fixed to walls and ceiling or laid in floors/trenches for the following sizes complete all as specified and directed :- [MAKE:-TATA / JINDAL / PRAKASH / SWASTIK as approved by GE]\n | | | |
|---|
| 89 | 22.1 | 80 mm bore | | 30 | RM |
|---|
| 90 | 22.2 | 50 mm bore | | 70 | RM |
|---|
| 91 | 22.3 | 40mm bore | | 30 | RM |
|---|
| 92 | 22.4 | 25mm bore | | 50 | RM |
|---|
| 93 | 22.5 | 20mm bore | | 100 | RM |
|---|
| 94 | 22.6 | 15mm bore | | 50 | RM |
|---|
| 95 | 23 | Drilling and tapping cast iron water mains (in position) by turning off water for branch connections of the internal dia 15mm GI pipe complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 96 | 24 | Drilling and tapping cast iron water mains (in position) by turning off water for branch connections of the internal dia 20mm GI pipe complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 97 | 25 | S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe for the following bores including taking out old unserviceable valve complete all as specified and directed :- [MAKE:-SANT / LEADER / RAMCO / ZOLOTO as approved by GE] | | | |
|---|
| 98 | 25.1 | 50 mm bore | | 8 | EACH |
|---|
| 99 | 25.2 | 40mm bore | | 8 | EACH |
|---|
| 100 | 25.3 | 25mm bore | | 10 | EACH |
|---|
| 101 | 25.4 | 20mm bore | | 20 | EACH |
|---|
| 102 | 25.5 | 15mm bore | | 20 | EACH |
|---|
| 103 | 26 | S&F Rubber gasket joint for cast iron spigot and socket pipes and fitting for the following sizes complete all as specified and directed :- | | | |
|---|
| 104 | 26.1 | 80mm bore | | 5 | EACH |
|---|
| 105 | 26.2 | 100 mm bore | | 5 | EACH |
|---|
| 106 | 26.3 | 150 mm bore | | 5 | EACH |
|---|
| 107 | 26.4 | 200 mm bore | | 4 | EACH |
|---|
| 108 | 26.5 | 250mm bore | | 4 | EACH |
|---|
| 109 | 27 | M&L for joint with rubber or fibre board gasket including necessary bolts, nuts, washers and white lead or mineral oil; for cast iron flanged pipes of following sizes complete all as specified and directed :- | | | |
|---|
| 110 | 27.1 | 80mm bore | | 2 | EACH |
|---|
| 111 | 27.2 | 100 mm bore | | 2 | EACH |
|---|
| 112 | 27.3 | 150 mm bore | | 2 | EACH |
|---|
| 113 | 27.4 | 200 mm bore | | 2 | EACH |
|---|
| 114 | 27.5 | 250mm bore | | 2 | EACH |
|---|
| 115 | 28 | S&F 3 layer PP-R (poly propylene random complymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain Brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors for the following sizes complete all as specified and directed :- [MAKE:-SFMC /VECTUS/ PRINCE/REPOL as approved by GE] | | | |
|---|
| 116 | 28.1 | 32 mm outer bore | | 70 | RM |
|---|
| 117 | 28.2 | 25 mm outer bore | | 200 | RM |
|---|
| 118 | 28.3 | 16 mm outer bore | | 125 | RM |
|---|
| 119 | 29 | S&F 3 layer PP-R (poly propylene random complymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain Brass threaded polypropylene random fittings laid in trenches, etc for the following sizes complete all as specified and directed :- [MAKE:-SFMC /VECTUS/ PRINCE/REPOL as approved by GE] | | | |
|---|
| 120 | 29.1 | 90 mm outer bore | | 100 | RM |
|---|
| 121 | 29.2 | 63 mm outer bore | | 100 | RM |
|---|
| 122 | 29.3 | 50 mm outer bore | | 80 | RM |
|---|
| 123 | 30 | S&F DI fitting such as bends, tappers, straight connection piece, Tee pieces, either one side flanged other socketed/ both flanged/ both socketed any type, radius and up to 150 mm bore including nut, bolt, packing material etc and making th joint leak proof complete all as specified and directed. | | 260 | KG |
|---|
| 124 | 31 | M&L for attending complaint of repair/ rectification of GI pipe line leakage etc by deploying skilled tratesman (plumber and helper) with all necessary GI fittings ie socket, union, elbow, bends etc) required and necessary excavation, earthwork and dewatering required for making leak proof and functional complete all as specified and directed.\nNote :- (i) The quoted rates shall deemed to include for all excavation, earth work and dewatering and new GI fittings of suitable size.\n(ii) The tradesman shall report to E/M complaint cell Bairagarh daily at 8.30 AM to take complaint from concerned JE E/M. The complaint must be attended on same day in stipulated time period by providing material required and deploying sufficient manpower by he contractor. The complaint slip duly signed by the users shall be returned back to complaint cell with proper feedback in the evening.\n(iii) New GI fitting of suitable size, yarn and safeda/ white lead required shall besupplied by the contractor. The quoted rate shall be deemed to include this provision.\n(iii) Complaint slip & other stationery required for attending complaint shall be supplied by the contractor with out ant extra cost to the Dept. | | | |
|---|
| 125 | 31.1 | 15 mm dia pipe | | 30 | Each joint |
|---|
| 126 | 31.2 | 20 mm dia pipe | | 30 | Each joint |
|---|
| 127 | 31.3 | 25 mm dia pipe | | 30 | Each joint |
|---|
| 128 | 31.4 | 40 mm dia pipe | | 25 | Each joint |
|---|
| 129 | 32 | CLEANING OF WATER TANKS (OHT, UG, SEMI-UG) INCLUDING ALLIED WORKS AT BAIRAGARH | | | |
|---|
| 130 | 33 | M&L for carefully washing out settled mud, alum, flocculant, etc from sedimentation tank (2 x 1.50 lakh & 1 x 1.25 lakh gallon capacity) of size 19.50m x 9.75m x 4.35m depth internal size of each tank having 2 nos buffer walls of size 15.15m x 0.15m x 4.0m height in each tank; drainning out complete waste water from tank mannually or by mechanical arrangments; cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush including scrapping out and applying one coat of super quality lime wash on outer stone wall surface of sedimentation tank and wirting the date of cleaning on the wall of tank on blue base with white colour; including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed. \nNote:- 3 tanks shall be measured as one job for payment purpose. | | 15 | EACH JOB |
|---|
| 131 | 34 | M&L for carefully washing out settled mud, alum, flocculant, etc from FLOCCULATOR TANK of 15.16 mtr dia & 4.5 mtr depth including external channels, chambers and outlet, etc; drainning out complete waste water from tank mannually or by mechanical arrangments; cleaning of bottom, all internal side walls, channel using brooms, wiper or nylon brush including scrapping out and applying one coat of super quality lime wash on outer stone wall surface of sedimentation tank and wirting the date of cleaning on the wall of tank on blue base with white colour; including cleaning of the surrounding area of the tank upto a distance of 3 mtrs from the outer edge of tank by cutting of grass, digging out roots, filling holes with earth, levelling of ground and removing waste material to a distance not exceeding 50m complete all as specified and directed. | | 3 | EACH JOB |
|---|
| 132 | 35 | All as per BOQ serial item No. 34.00 above but flocculator (0.5 lakh gallon capacity) including lime & Alum mixing chambers 03 Nos, intake chamber complete all as specified and directed. | | 11 | EACH JOB |
|---|
| 133 | 36 | Cleaning of clear water semi UG sump 1 Lakh gallon capacity at main filter pump house at Bairagarh complete all as specified and directed. . \nNOTE:- Quoted rates is deemed to include for:-\n(i) Cleaning inside walls, floor, dome, ceiling with wire steel brush removing pile/sludge/ silt/ alge and other forgein material and washout with clear water all as specified and upto the satisfaction of EIC .\n(ii) Applying one coat of super quality lime wash on inner wall surface after cleaning of tank\n(iii) Cleaning the surrounding area of the reservoir to a distance of 3 mtrs all around its circumference including cutting of grass, digging out roots, filling holes, levelling of ground and removing waste material to a distance not exceeding 50m complete all as directed.\n | | 2 | EACH JOB |
|---|
| 134 | 37 | All as per BOQ serial item No.36.00 above but for clear water semi UG sump 1.5 lakh gallon capacity at main filter pump house at Bairagarh complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 135 | 38 | All as per BOQ serial item No.36.00 above but for clear warer semi UG sump 3 lakh gallon capacity at main filter pump house at Bairagarh complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 136 | 39 | All as per BOQ serial item No. 36.00 above but for clear water semi UG sump 2 lakh gallon capacity at New MH pump house complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 137 | 40 | All as per BOQ serial item No. 36.00 above but for sump 1.5 lakh gallon capacity at tank No 2 at 1 TB area complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 138 | 41 | All as per BOQ serial item No. 36.00 above but for semi UG sump 6.0m x 6.0m x 2.6m at MH pump house complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 139 | 42 | All as per BOQ serial item No. 36.00 above but for semi UG sump 6.0m x 6.0m x 3m at TRS pump house complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 140 | 43 | All as per BOQ serial item No. 36.00 above but for semi UG sump 6.0m x 6.0m x 2.6m at MH pump house complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 141 | 44 | All as per BOQ serial item No. 36.00 above but for RCC OH tank of 1 Lakh gallon capacity up to 18 mtr staging at 3 EME centre area complete all as specified and directed. | | 5 | EACH JOB |
|---|
| 142 | 45 | All as per BOQ serial item No. 36.00 above but for RCC OH tank of 75000 gallon capacity on 18m staging at TRS complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 143 | 46 | All as per BOQ serial item No. 36.00 above but for RCC OH tank of 50000 gallon capacity on 9.0m staging at ASC Butchery (Khajuri) complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 144 | 47 | All as per BOQ serial item No. 36.00 above but RCC OH tank of 0.5 lakh gallon capacity up to 16.0m staging MAP Offrs Qtr at 3 EME centre area complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 145 | 48 | All as per BOQ serial item No. 36.00 above but RCC OH tank of 0.5 lakh gallon capacity up to 16.0m staging MAP JCOs/ORs Qtr at 3 EME centre area complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 146 | 49 | All as per BOQ serial item No. 36.00 above but RCC OH tank of 1.0 lakh gallon capacity up to 16.0m staging at New MH accn complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 147 | 50 | All as per BOQ serial item No. 36.00 above but for 3 x 10000 Ltr HDPVC tank at key personnel qtrs complete all as specified and directed. \nNote:- 3 x 10000 ltr HDPVC tanks shall be measured as one job for payment purpose. | | 2 | EACH JOB |
|---|
| 148 | 51 | M&L for cutting/treeming grass, buses, and cleaning complete inside area of Main filter pump house and 2 meter outside fencing including cleaning of fencing from grass /treeming carefully taking proper precautions of electric cables, pipe lines, etc including using own T&P reqd at site, etc complete all as specifed and directed. (Approx area of pump house 500m x 150m). | | 2 | EACH JOB |
|---|
| 149 | 52 | M&L for cleaning/taking out sludge, soil, stones, grass, etc from open drain (1 feet to 3 feet in width and 1 feet to 4 feet in depth and approx 600 m in length) and spreading /leveling outside 10 meter from drain with & including applying one coat of white wash on walls at main filter pump house complete all as specified and directed. \n | | 2 | EACH JOB |
|---|
| 150 | 53 | M&L for washing /cleaning of rapid sand gravity filter (02 Nos) mannually by scrapping out upper layer (appx 10 cm) for removing forigen material/mud, etc and cleaning side wall / tiles portion including flushing mud water by using valve & compressor; including applying one coat of white wash and laying fresh sand to makeup level of sand in filter bed up to required level (which decreases due to daily backwashing of filter bed) complete all as specified and directed. | | 11 | EACH JOB |
|---|
| 151 | 54 | M&L for cleaning/taking out sludge, soil, stones, grass, etc from open jack well (3.5 mtr dia, 4 mtr depth) and spreading /leveling outside 10 meter from well with & including applying one coat of white wash on walls at Raw water pump house complete all as specified and directed. \nNote:- 5 Nos. of jack wells of Raw Water PH shall be measured as one job for payment purpose. | | 1 | EACH JOB |
|---|
| 152 | 55 | Disconnecting existing water tanks of capacity upto & including 500 litres, setting aside (or lowering if required) for repairs including making it leak proof using M-Seal or other approved products, replacemnt of barrel nipple, cleaning, etc and hoisting, if required, reconnecting and refixing in position (cleaning, repairing etc to be measured separately) complete all as specified and directed. \nNOTE: Tanks which can not be repaired shall be sold to contractor under schedule of credit. | | 55 | EACH JOB |
|---|
| 153 | 56 | Disconnecting existing water tanks of capacity above 500 litres and upto 1000 ltrs, setting aside (or lowering if required) for repairs including making it leak proof using M-Seal or other approved products, replacemnt of barrel nipple, cleaning, etc and hoisting, if required, reconnecting and refixing in position (cleaning, repairing etc to be measured separately) complete all as specified and directed. \nNOTE: Tanks which can not be repaired shall be sold to contractor under schedule of credit. | | 21 | EACH JOB |
|---|
| 154 | 57 | Cleaning and removing all scale and dirt, using bleaching powder, etc from water tanks and from mouth of circulating pipes, etc of capacity not exceeding 500 litres complete all as specified and directed. \n | | 2190 | EACH |
|---|
| 155 | 58 | Cleaning and removing all scale and dirt, using bleaching powder, etc from water tanks and from mouth of circulating pipes, etc of capacityabove 500 litres upto 1000 ltrs complete all as specified and directed. \nNote (FOR BOQ Serial Item Nos. 56 & 57):- \n(i) Any damage to to tank during cleaning process shall be the sole responsibility of the contractor and he will have to get it reapired/replced without any extra cost to the department.\n(ii) The outlet of tank shall be blocked using cotton waste before cleaning of the tank to avoid blockage of outlet pipes.\n(iii) All care shall be taken by the contractor to avoid blockage of pipes after cleaning of tank, air lock of pipes, etc if any shall be removed immediately.\n(iv) Users signature shall be obtained for each tank cleaned. | | 810 | EACH |
|---|
| 156 | 59 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 15 mm bore (minimum weight 142 gms) complete all as specified and directed. [MAKE:-PRAYAG / POLYTUFF as approved by GE] | | 30 | EACH |
|---|
| 157 | 60 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and directed. [MAKE:-PRAYAG / POLYTUFF as approved by GE] | | 30 | EACH |
|---|
| 158 | 61 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm bore (minimum weight 455 gms) complete all as specified and directed. [MAKE:-PRAYAG / POLYTUFF as approved by GE] | | 100 | EACH |
|---|
| 159 | 62 | Fixing only Rotational moulded, polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes including taking down old tank any type and depositing to MES store complete all as specified and directed. \n[Water tank shall be issued under Schedule ' B' free for fixing\"] \n | | 100 | EACH |
|---|
| 160 | 63 | Fixing only Rotational moulded, polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes including taking down old tank any type and depositing to MES store complete all as specified and directed. \n[Water tank shall be issued under Schedule ' B' free for fixing\"] \n | | 100 | EACH |
|---|
| 161 | 64 | S&F Rotational moulded (three layered), polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes including taking down old tank any type complete all as specified and directed. \n[MAKE:-SINTEX / POLYWELL / ROTAX/ JS POLYPLAST / POLYCON as approved by GE] \n | | 2 | EACH |
|---|
| 162 | 65 | S&F Rotational moulded (three layered), ISI marked polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes including taking down old tank complete all as specified and directed. \n[MAKE:-SINTEX / POLYWELL / ROTAX/ JS POLYPLAST / POLYCON as approved by GE] \n | | 2 | EACH |
|---|
| 163 | 66 | Deduct Schedule of credit (calculation will be done off line) Rs.1,52,870.00 | | | |
|---|