Construction Of Cargo Gsd Gate Complex And Watch Tower At Goa International Airport Sh Providing Of Boom Barrier For Gate No 1 And Bollard At Gate No 1 Entry And Exist Gate Of Mlcp, Goa Airport-Goa

Airports Authority Of India has published Construction Of Cargo Gsd Gate Complex And Watch Tower At Goa International Airport Sh Providing Of Boom Barrier For Gate No 1 And Bollard At Gate No 1 Entry And Exist Gate Of Mlcp. Submission Date for this Tender is 30-06-2020. Gate Barrier Systems Tenders in Goa Airport Goa. Bidders can get complete Tender details and download the document.




Tender Notice

24702229
Construction Of Cargo Gsd Gate Complex And Watch Tower At Goa International Airport Sh Providing Of Boom Barrier For Gate No 1 And Bollard At Gate No 1 Entry And Exist Gate Of Mlcp
Open Tender
Indian
Goa
Goa Airport
30-06-2020

Tender Details

Construction Of Cargo Gsd Gate Complex And Watch Tower At Goa International Airport Sh Providing Of Boom Barrier For Gate No 1 And Bollard At Gate No 1 Entry And Exist Gate Of Mlcp

Key Value

Document Fees
INR 1120 /-
EMD
INR 197880.0 /-
Tender Value
INR 98.93 Lakhs /-

BOQ Items

Name of Work: Construction of Cargo / GSD gate Complex and watch tower at Goa International Airport. SH: Providing of Boom Barrier for Gate no. 1 and Bollard at Gate no. 1, Entry & Exist gate of MLCP.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, Installation, testing and Commissioning of straight type boom barrier of 5 metre suitable for a road width of 9.9 metres with\ni.)torque motor drive\nii.)Microprocessor/PLC based control unit\niii.)Galvanised steel with powder coated enclosure\niv.)housing steel frame of GI\nv.)with open/close option mechanically in case of power failure\nvi.)with push button and remote control panel\nvii.)having IP 54 or higher\nviii.)having warmning light/traffic light\nix.)nominal operating on power supply 0f 230 Volts,50 Hz\nx.)meeting technical specifications attached\nxi.)boom made of aluminium or superior material with retro reflective stickers, rubber pads for safety\nxii.)opening and closing time not more than 5 seconds\nxiii.)providing and laying of control cable, power cable (In ground DWC pipe at a depth of 0.75 mtr), fixing of control switches /remote control modules in designated rooms and all civil works and accessories etc complete as required.\n(Refer Technical Specifications Attached for more details)\n 2 Job
2 2 Supply, Installation, testing and Commissioning of K4 rated hydraulic retractable automatic bollards for a road width of 9.9 metres with\ni.) having minimum 1000 mm height for each bollard\nii.)having minimum 220 mm diamter for each bollard\niii.)raising/lowering time of not more than 4 to 6 seconds\niv.)material of construction of cylinder ST52/S355JR grade steel with Stainless steel cover\nv.)with push button and remote control\nvi.)having IP 66\nvii.)having provision for manual down operation in case of power failure\nviii.)nominal operating on power supply 0f 440Volts(nominal),50 Hz, 3 Phase/230 Volts (nominal),50 Hz ,1 Phase.\nix.)meeting technical specifications attached\nx.)distance between each bollard (centre to centre) shall not be more than 1.2 metres and not less than 10 No. of bollards. \nxi.)shall be provided with circular illuminated LED lights\nxii.)adequate safety against vehicle and humans(loop detectors and photo sensors)\nxiii.)PLC/Microprocessor based control system\nxiv.)providing and laying of control cable, power cable(In ground DWC pipe at a depth of 0.75 mtr) fixing of control switches /remote control modules in designated rooms and all civil works like excavcation for foundation. providing of foundation of suitable size for the system and accessories etc complete as required.\n(Refer Technical Specifications Attached for more details)\n 1 Job
3 3 Supply, Installation, testing and Commissioning of K4 rated hydraulic retractable automatic bollards for a road width of 6.8 metres with\ni.) having miniumum 1000 mm height for each bollard\nii.)having miniumum 220 mm diamter for each bollard\niii.)raising/lowering time of not more than 4 to 6 seconds\niv.)material of construction of cylinder ST52/S355JR grade steel with Stainless steel cover\nv.)with push button and remote control\nvi.)having IP 66\nvii.)having provision for manual down operation in case of power failure\nviii.)nominal operating on power supply 0f 440Volts(nominal),50 Hz, 3 Phase/230 Volts (nominal),50 Hz ,1 Phase.\nix.)meeting technical specifications attached\nx.)distance between each bollard (centre to centre) shall not be more than 1.2 metres and not less than 7 No. of bollards. \nxi.)shall be provided with circular illuminated LED lights\nxii.)adequate safety against vehicle and humans(loop detectors and photo sensors)\nxiii.)PLC/Microprocessor based control system\nxiv.)providing and laying of control cable, power cable(In ground DWC pipe at a depth of 0.75 mtr) fixing of control switches /remote control modules in designated rooms and all civil works like excavcation for foundation. providing of foundation of suitable size for the system and accessories etc complete as required.\n(Refer Technical Specifications Attached for more details)\n 1 Job
4 4 Supply, Installation, testing and Commissioning of K4 rated hydraulic retractable automatic bollards for a road width of 7.8 metres with\ni.) having miniumum 1000 mm height for each bollard\nii.)having miniumum 220 mm diamter for each bollard\niii.)raising/lowering time of not more than 4 to 6 seconds\niv.)material of construction of cylinder ST52/S355JR grade steel with Stainless steel cover\nv.)with push button and remote control\nvi.)having IP 66\nvii.)having provision for manual down operation in case of power failure\nviii.)nominal operating on power supply 0f 440Volts(nominal),50 Hz, 3 Phase/230 Volts (nominal),50 Hz ,1 Phase.\nix.)meeting technical specifications attached\nx.)distance between each bollard (centre to centre) shall not be more than 1.2 metres and not less than 8 No. of bollards.\nxi.)shall be provided with circular illuminated LED lights\nxii.)adequate safety against vehicle and humans(loop detectors and photo sensors)\nxiii.)PLC/Microprocessor based control system\nxiv.)providing and laying of control cable, power cable(In ground DWC pipe at a depth of 0.75 mtr) fixing of control switches /remote control modules in designated rooms and all civil works like excavcation for foundation. providing of foundation of suitable size for the system and accessories etc complete as required.\n(Refer Technical Specifications Attached for more details)\n 1 Job
5 5 Supply of LT power cable of 1.1 KV grade of following sizes Aluminium conductor XLPE insulated PVC sheathed armoured/unarmoured cable confirming to IS 7098 (Part-I) -1988 with upto date ammendment as required. \n4Cx25Sqmm\n 732 Mtrs.
6 6 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. \nUpto 35 sq. mm (clamped with 1mm thick saddle)\n 520 Mtrs.
7 7 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required\nUpto 35 Sqmm\n 90 Mtrs.
8 8 Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing alongwith existing surface /recessed conduit/ submain wiring/cable as required. 1220 Mtrs.
9 9 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required .\n(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)\n 3 Each
10 10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\nSingle pole and neutral 9 Each
11 11 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\nTriple pole and neutral 6 Each
12 12 Supplying and making end termination with brass compression gland and aluminium lugs for following size for PVC/ XLPE insulated and PVC sheathed armoured aluminium conductor cable of 1.1. KV grade as required : \n4 x 25 sq.mm. (28mm) 2 Set
13 13 Supply and laying of 50mm dia ISI marked B class GI pipe after cutting the bituminous/concrete portion of the road, excavating the remaining earth under the road to make a trench of 75cm depth from the surface of the road laying and allignment of pipe, back filling of trench with available earth, filling the bituminus portion with cement concrete upto finished road level after properly consolidating the earth, curing the concrete etc complete as required as per the direction of Engineer In Charge. 10 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail