| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-07-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-07-2020 |
| 2 | 06-07-2020 | AMENDMENT_1 | BOQ | 13-07-2020 |
| Name of Work : REPAIR MAINT OF FIRE ALARM PANEL, VOLTAGE STABLISER, CRANES AND OTHER E/M ASSETS IN TECHNICAL AREA AT AF STN JODHPUR | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply and fixing in repairs 12 Volt 7AH capacity Battery suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 20 | Each | |
| 2 | 2 | Supply and fixing in repairs Charging Card suitable for Autocut Battery Charger complete all as specified and directed by the Engineer in charge. | 6 | Each | |
| 3 | 3 | Supply and fixing in repairs Complete Main Control Card (Mother Card) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 2 | Each | |
| 4 | 4 | Supply and fixing in repairs Zone Card with complete IC suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 5 | 5 | Supply and fixing in repairs Photo Electric Smoke Detector suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 45 | Each | |
| 6 | 6 | Supply and fixing in repairs Detectors complying with and type certified to EN-45 addressable type smoke detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and directed by the Engineer in charge. | 30 | Each | |
| 7 | 7 | Supply and fixing in repairs Heat Detector non addressable type suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 35 | Each | |
| 8 | 8 | Supply and fixing in repairs Heat and Smoke Detector non addressable type suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 35 | Each | |
| 9 | 9 | Supply and fixing in repairs Manual Call Point (Pill Box, Aluminium Body) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 10 | Each | |
| 10 | 10 | Supply and fixing in repairs Hooter capable to work on 24 DC Volt suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 10 | Each | |
| 11 | 11 | Supply and fixing in repairs Response Indicator (RI) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 8 | Each | |
| 12 | 12 | Supply and fixing in repairs Complete FIRE ALARM PANEL with all accessories conventional type suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 3 | Each | |
| 13 | 13 | Supply and fixing in repairs Complete FIRE ALARM PANEL with all accessories addressable type microprocessor based suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge. | 1 | Each | |
| 14 | 14 | Material and labour for rewiring of faulty area of fire alarm system zone wise, rewiring with 1.5 Sqmm (nominal area) PVC insulated and PVC unsheathed FRLS cable, stranded copper conductor with and including steel rigid conduit 20 mm dia medium grade ISI marked with all fittings and accessories complete all as specified & directed by Engineer-in-Charge. | 350 | Running Metre | |
| 15 | 15 | Material and labour for general servicing of over head crane of capacity up to 2 Ton capacity (hand operated crane) with suitable T&P and replacement all connected deffective spare parts of crane and re-assembeling with necessary electric connections including greasing, gear box maintenece, chain pulley, color coating, crain rail allignment, chain replacement and all connecting items for fully operational cranes etc including load testing in presence of engineer in charge.\nNote :- Contractor shall rectify the problem within 4 days from receipt of complaint from engr-in-charge, panelty for not attending the complaint shall be 3% of quoted rate per day. | 10 | Each Job | |
| 16 | 16 | Material & labour in replacement of top lever with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 17 | 17 | Material & labour in replacement of master lock with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 18 | 18 | Material & labour in replacement of main GIRARI with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 19 | 19 | Material & labour in replacement of BEARING SET with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 8 | Each | |
| 20 | 20 | Material & labour in of replacement of main pulley with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 3 | Each | |
| 21 | 21 | Material & labour in replacement of loading chain for wheel of existing crane of suitable size with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 50 | Running Metre | |
| 22 | 22 | Material & labour in replacement of pull chain for wheel of existing crane of suitable size with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 75 | Running Metre | |
| 23 | 23 | Material & labour in replacement of load lever with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 3 | Each | |
| 24 | 24 | Material & labour in replacement of steel side plate with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 8 | Each | |
| 25 | 25 | Material & labour in replacement of main shaft with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 26 | 26 | Repair / maintenance of unserviceable electrically operated crane of capacity upto 2 Ton with suitable T&P and painting of crane replacement all connected deffective spare parts of crane and re-assembeling with necessary electric connections, fully blocking of leakage of hydraullic oil etc, including load testing in presence of engineer in charge complete all as specified and directed by the Engineer in charge. | 2 | Each Job | |
| 27 | 27 | Material & labour in replacement of EOT electric panel wiring including heavy duty contactor (upto 125A) , relay, fuse replacement with suitable electrical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 1 | Each Job | |
| 28 | 28 | Material & labour in of replacement of steel wire rope 10mm size, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 100 | Running Metre | |
| 29 | 29 | Material & labour in replacement of complete gear box of remote operated assembly of forward, reverse, up, down opearation and replacement of brake leather of up and down assembly, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 1 | Each Job | |
| 30 | 32 | Material & labour in replacement of bearing suitable for EOT electric motor capacity upto 02 HP complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 31 | 33 | Material & labour in replacement of EOT control card, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 1 | Each | |
| 32 | 34 | Material & labour in replacement of EOT guider belt both side of crane at crane rail side suitable, for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 2 | Each | |
| 33 | 35 | Material & labour in replacement of EOT limit switch, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 2 | Each | |
| 34 | 36 | Material & labour in replacement of EOT gear box with bushing and break oil, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 1 | Each | |
| 35 | 37 | Material & labour in replacement of power supply copper cable unarmed of size 25 sqmm 4 core with all accesoories, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge. | 150 | Running Metre | |
| 36 | 38 | Material & labour in replacement of copper conductor cable of size 1.5 sqmm 12 core for EOT control panel complete all as specified and directed by the Engineer in charge. | 150 | Running Metre | |
| 37 | 39 | Material & labour in replacement of electric panel board suitable for 7.5 HP electric motor, for both side hanger door complete with suitable electric wiring , cleaning , greasing etc complete all as specified and directed by the Engineer in charge. | 4 | Each | |
| 38 | 40 | Material & labour in replacement of gear box suitable for 7.5 HP electric motor for both side hanger door with hanger door chain replacement complete all as specified and directed by the Engineer in charge. | 8 | Each | |
| 39 | 41 | Material & labour for rewinding of 7.5 HP motor by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying inclujding scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer in Charge. | 1 | Each | |
| 40 | 42 | Supply and fixing in repair electric motor of 2.5 HP capacity with gear box and megnatic coupling of electric motor, for both side hanger door complete etc complete all as specified and directed by the Engineer in charge. | 1 | Each | |
| 41 | 43 | Material & labour for repairing of electric panel suitable for 2.5 HP motor including rewiring with existing size copper wire, replacement of contactor (upto 100 A), relay and other connected items with all accessories, for both side hanger door complete all as specified and directed by the Engineer in charge. | 1 | Each Job | |
| 42 | 44 | General servicing of unserviceable hydaullic operated crane of capacity upto 1 Ton with suitable T&P and painting of crane replacement all connected deffective spare parts of crane and re-assembeling with necessary electric connections testing at LDP lab area, fully blocking of leakage of hydraullic oil etc for fully operational cranes including load testing in presence of engineer in charge complete all as specified and directed by the Engineer in charge.. | 1 | Each Job | |
| 43 | 46 | Repair to existing ELECRTONIC THYRISTOR MODULE or without thyristor module TYPE automatic / manual type APFC panel including painting of APFC panel, cleaning of dust inside the panel from electric blower cleaning of contractors, relays junction points / connectors servicing overhauling of cooling fan complete testing of APFC relay including necessary setting with CTs load adjustment to match with replacement of U/S parts of capacity 5 KVAR to 200 KVAR to set the power factor in range between 0.96 to 0.990 complete all as directed as specified by Engr in Charge. \nNote : 1. Replacement of U/S items which are covered under respective items of BOQ shall be measured & paid separetely. \n2. Replacement of minor items / spares shall deemed to be included in the above items & not to be paid separately. \n | 15 | Each Job | |
| 44 | 47 | Supply and fixing in Replacement of contactor capacitor heavy duty type 3 pole AC of capacity having coil voltage 250 volt up to 20 KVAR along with 1 No + 1 NC auxilary contact complete all as directed as specified by Engr in Charge. Make : L&T / GE /EPCOS | 8 | Each | |
| 45 | 48 | Supply & fix in repairs existing contactor capacitor duty type 3 pole AC of capacity having coil voltage 250 volt up to 40 KVAR along with 1 No + 1 NC auxilary contact complete all as directed as specified by Engr in Charge. Make : L&T / GE /EPCOS | 8 | Each | |
| 46 | 49 | Supply & fix in repairs contactor capacitor duty type 3 pole AC of capcity having coil voltage 250 volt up to 60 KVAR along with 1 No + 1 NC auxilary contact complete all as directed as specified by Engr in Charge. Make: L&T / GE /EPCOS | 5 | Each | |
| 47 | 50 | Supply & fix in repairs APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 8 stage as specified and directed by Engr-in-Charge. Make: EPOCS / ENERCON / DUCATI | 4 | Each | |
| 48 | 51 | Supply & fix in repairs APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 12 stage as specified and directed by Engr-in-Charge. Make: EPOCS / ENERCON / DUCATI | 2 | Each | |
| 49 | 52 | Supply & fix in repairs exhaust fan of APFC panel 220 V AC of suitable size for APFC panel complete all as specified and directed by Engr-in-Charge. | 6 | Each | |
| 50 | 53 | Supply & fix in repairs voltmeter 0-500 volt digital type type, lamp accurracy class -I complete all as specified and directed by Engr-in-Charge. | 6 | Each | |
| 51 | 54 | Supply & fix in repairs CT coil suitable for amp meter 100/5 amp ratio, accurracy Class-I complete all as specified and directed by Engr-in-Charge. make AE/ ENERCON/ EPCOS, | 9 | Each | |
| 52 | 55 | Supply & fix in repairs CT coil suitable for amp meter 200/5 amp ratio, accurracy Class-I complete all as specified and directed by Engr-in-Charge. make AE/ ENERCON/ EPCOS, | 6 | Each | |
| 53 | 56 | Supply and fixing in repairs existing ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC, of capcity having coil voltage 250 volt upto 10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engr-in-Charge Make : L&T / GE Power / C&S/EPCOS | 2 | Each | |
| 54 | 57 | Supply and fixing in repairs existing ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC, of capcity having coil voltage 250 volt upto 25 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engr-in-Charge Make : L&T / GE Power / C&S/EPCOS | 2 | Each | |
| 55 | 58 | Supply and fixing in repairs existing ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC, of capcity having coil voltage 250 volt upto 50 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engr-in-Charge Make : L&T / GE Power / C&S/EPCOS | 2 | Each | |
| 56 | 59 | Supply and fixing in repairs capacitor 440 volts 50 HZ electric complete of capacity 10 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 2 | Each | |
| 57 | 60 | Supply and fixing in repairs capacitor 440 volts 50 HZ, ULTRA HEAVY DUTY complete of capacity 12.5 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 2 | Each | |
| 58 | 61 | Supply and fixing in repairs capacitor 440 volts 50 HZ, ULTRA HEAVY DUTY complete of capacity 15 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 2 | Each | |
| 59 | 62 | Supply and fixing in repairs capacitor 440 volts 50 HZ, ULTRA HEAVY DUTY complete of capacity 20 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 2 | Each | |
| 60 | 63 | Supply and fixing in repairs capacitor 440 volts 50 HZ, ULTRA HEAVY DUTY complete of capacity 25 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 2 | Each | |
| 61 | 64 | Supply and fixing in repairs capacitor 440 volts 50 HZ, complete of capacity 7.5 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 3 | Each | |
| 62 | 65 | Supply and fixing in repairs capacitor 440 volts 50 HZ, complete of capacity 5 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 3 | Each | |
| 63 | 66 | Supply and fixing in repairs capacitor 440 volts 50 HZ, complete of capacity 3 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 3 | Each | |
| 64 | 67 | Supply and fixing in repairs capacitor 440 volts 50 HZ complete of capacity 2 KVAR (Bottle type ) gas filled complete all as specified and directed by Engr-in-Charge | 3 | Each | |
| 65 | 68 | Supply and fixing in repairs capacitor 440 volts 50 HZ complete of capacity 1 KVAR (Bottle type) gas filled complete all as specified and directed by Engr-in-Charge | 3 | Each | |
| 66 | 73 | Supply and fixing in repairs of SCRs used in thyrister switching suitable for 100 KVAR APFC panel complete all as specified and directed by engr in charge. Make : L&T / GE Power / C&S/EPCOS | 18 | Each | |
| 67 | 74 | Supply and fixing in repairs of SMPS 220 V AC input and 24 V DC output and used in APFC panel complete all as specified and directed by engr in charge. | 6 | Each | |
| 68 | 75 | Supply and fixing in repairs MCB TP 450 volts 10 KA 'C' curve type of capacity 32 amp complete all as specified and directed by engr in charge. Make : L&T/ Legrand / ABB / Siemens | 15 | Each | |
| 69 | 76 | Supply and fixing in repairs MCB TP 450 volts 10 KA 'C' curve type of capacity 63amp complete all as specified and directed by engr in charge. Make : L&T/ Legrand / ABB / Siemens | 15 | Each | |
| 70 | 77 | General servicing of Automated vertical storage & retrieval system (Lean lift) consisting of jobs as under :-\n(a) Mechanical maintenance:- 1)Retriever levelling and allignment \n2) Guide wheel alignment \n3) checking of laoding runners oil \n4) Pushers positioning user manual mode \n5) checking of bolted joints \n6) checking of chain tension \n7) checking of breake adjustment \n8) checking of gear box oil level \n9) Lubrication of chains \n(b) Electrical Jobs:- 1) checking & cleaning of all contacts \n2) checking of looser wire connection \n3) checking of limit switches\n(c) Electronic Jobs:-checking and cleaning of all PCBs, checking of sensors, checking of relay functioning.\n(d) Software Jobs:- upgradation in PLC programme and user interface.\nNote:- (i) Each job consists general servicing as described above for one lift.\n(ii) Major items to be replaced in general servicing shall be paid as supply only.\n2. Replacement of minor items / spares shall deemed to be included in the above items & not to be paid separately. | 8 | Each Job | |
| 71 | 77.01 | Supply only S2 Area sensor Ht -844mm analog O/P Make:-Banner or equivellent | 1 | Each Set | |
| 72 | 77.02 | Supply only AC drives FRE 120 FRD 022,036 | 1 | Each Set of three | |
| 73 | 77.03 | Supply only PLC 28SV ,DVP16SP,DVP08SM,AD04 & HMI DOPB07S415 | 1 | Each | |
| 74 | 77.04 | Supply only Height curtain sensor PLCP1-780-A2-V1 | 1 | Each | |
| 75 | 77.05 | Supply only machanical spare part kit (pushers, bolts, tray moulds, rollers, main runners, loading runners, diamond chains, spockets, auto door sliding system etc) | 1 | Each Set | |
| 76 | 78 | Repair maintenance and general servicing of isolation transformer 600 KVA of PS1 and 200 KVA of PS2 including cleaning of winding from dust and checking the electric connection,cooling fan serviceability with necessary wiring and all connecting works all as specified and directed by engr in charge. | 1 | Each job | |
| 77 | 79 | Supply and fixing in repairs cooling fan of isolation transformer of 600 KVA with timing setting including necessary wiring and connecting works all as specified and directed by engr in charge. | 8 | Each | |
| 78 | 80 | Supply and fixing in repairs single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and directed by Engr-in-Charge | 100 | Each | |
| 79 | 81 | Material & labour in repairs 40 mm bore galvanised steel tubing, light grade, 1.50 m long with MS plate of minimum 3 mm thick welded as base for fixing of air termination rod including thrust block complete as specified and directed by engr in charge. | 100 | Each | |
| 80 | 82 | Material & labour for precast cement concrete 1:3:6 type C1 (Using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6, for fixing/ mounting of running earthing conductor complete all as specified and as directed by the Engr-in - Charge. | 3 | Cubic Metre | |
| 81 | 83 | Supply and fixing in repairs aluminium strip 25x3 mm complete with saddles and fixing screw for fitting the strip complete all as specified and as directed by the Engr-in - Charge. | 1000 | Running Metre | |
| 82 | 84 | Supply and fixing in repairs fire hydrant valve type A (single head outlet) of size 63mm dia confirming to IS 5290 complete all as specified and as directed by the Engr-in - Charge. | 2 | Each | |
| 83 | 85 | Supply and fixing in repairs gun metal branch pipe of 63mm dia instantaneous inlet, made threaded outlet 15 mm bore nozzle short complete all as specified and as directed by the Engr-in - Charge. | 2 | Each | |
| 84 | 86 | Supply and fixing in repairs 63mm dia, 15 m CP hose pipe confirming to IS -636 complete with male and female coupling conforming to IS 903 complete all as specified and as directed by the Engr-in - Charge. | 1 | Each | |
| 85 | 87 | Supply and fixing in repairs 63mm dia, 7.5 m hose pipe confirming to IS -636 complete with male and female coupling conforming to IS 903 complete all as specified and as directed by the Engr-in - Charge. | 1 | Each | |
| 86 | 88 | Supply and fixing in repairs Hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard complete all as specified and as directed by the Engr-in - Charge. | 1 | Each | |
| 87 | 89 | Supply and fixing in repairs Hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard but used as internal complete all as specified and as directed by the Engr-in - Charge. | 1 | Each | |
| 88 | 90 | Supply and fixing in repairs 150 mm bore cast iron sluice valve heavy duty, class PN 1.6 flanged ends any pattern with head wheel and bras spindle ISI marked, conforiming to IS 780 with jointing material, flanged joint rubber gasket 6mm thick nuts, MS nuts, bolts, washers, rubber flange complete all as specified and as directed by the Engr-in - Charge. | 1 | Each | |
| 89 | 91 | Supply and fixing in repairs 100 mm bore cast iron sluice valve heavy duty, class PN 1.6 flanged ends any pattern with head wheel and bras spindle ISI marked, conforiming to IS 780 with jointing material, flanged joint rubber gasket 6mm thick nuts, MS nuts, bolts, washers, rubber flange complete all as specified and as directed by the Engr-in - Charge. | 1 | Each | |
| 90 | 92 | Supply and fixing in repairs CI reflux valve of size 150mm dia bore with bypass arrangement complete all as specified and as directed by the Engr-in - Charge. | 2 | Each | |
| 91 | 93 | Supply and fixing in repairs pressure differential switches IPS -100 with wiring etc complete all as specified and as directed by the Engr-in - Charge. | 2 | Each | |
| 92 | 94 | Supply and fixing in repairs 25 mm dia Auto Air Surge and Drain valve for water piping complete all as specified and as directed by the Engr-in - Charge.\n | 12 | Each | |
| 93 | 95 | Material & labour for general servicing of 100 HP centrifugal pumpset with electric motor 100 HP and jockey pump 12.5 HP including replacement of worn out impellers-01 set with bronze impellers, replacing bearing-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house re-assembling with motor and foundation and testing and make it functional to the entire satisfaction of the Engineer in Charge. | 1 | Each Job | |
| 94 | 96 | Material & labour for general servicing of 100 HP centrifugal pumpset including replacement of worn out impellers-01 set with bronze impellers, replacing bearing-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house re-assembling with motor and foundation and testing and make it functional to the entire satisfaction of the Engineer in Charge. | 1 | Each Job | |
| 95 | 97 | Material & labour for General servicing of 100 HP diesal engine used in fire fighting including engine oil change, diesal and oil fielter change, radiator cleaning, coolant chage , air fielter replacement, cleaning of diesal tank, general servicing of DG set self and testing and make it functional to the entire satisfaction of the Engineer in Charge. | 1 | Each Job | |
| 96 | 98 | Material & labour for general servicing of 75 HP centrifugal pumpset with electric motor 75 HP and jockey pump 7.5 HP including replacement of worn out impellers-01 set with bronze impellers, replacing bearing-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house re-assembling with motor and foundation and testing and make it functional to the entire satisfaction of the Engineer in Charge. | 2 | Each Job | |
| 97 | 99 | Material & labour for general servicing of 7.5 HP centrifugal pumpset with electric motor 7.5 HP including replacement of worn out impellers-01 set with bronze impellers, replacing bearing-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house re-assembling with motor and foundation and testing and make it functional to the entire satisfaction of the Engineer in Charge. | 2 | Each Job | |
| 98 | 100 | Material & labour for general servicing of 5 HP centrifugal pumpset with electric motor 5 HP including replacement of worn out impellers-01 set with bronze impellers, replacing bearing-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house re-assembling with motor and foundation and testing and make it functional to the entire satisfaction of the Engineer in Charge. | 6 | Each Job | |
| 99 | 101 | Material & labour in replacement 16 sqmm 3 core aluminium unarmoured PVC sheathed cable for 3 phase motor with PVC conduit of 20mm size for protection of cable complete all as specified and as directed by the Engr-in Charge. | 400 | Running Metre | |
| 100 | 102 | Material & labour for rewinding of MOTOR from 75 HP TO 100 HP motor by opening the motor , taking out burnt out winding and rewinding of motor with super enamelled copper conductor size of same gauge and size as per existing, varnishing, heat drying including scraping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested complete all as specified and as directed by the Engr-in Charge. | 1 | Each job | |
| 101 | 103 | Material & labour for dismantling the submersible pump set and motor assembly of capacity up to 3 HP installed in sump by taking out GI pipe line of any dia and length complete using skilled and experienced labout and transporting the same to workshop for repair and replacement of thrust bearings, replacement of worn impellers -01 set , replacement dof worn of bushings and shifting repaired pump set with repaired motor back to site after repair and re- assembling the same in the bore well after testing, and make it functional to the entire satisfaction of the Engineer in Charge. | 1 | Each Job | |
| 102 | 104 | Supply and fixing in repairs rubber/tyre coupling of pumping set of 100 HP complete all as specified and directed by the Engr - in Charge. | 2 | Each | |
| 103 | 105 | Supply and fixing in repairs rubber/tyre coupling of pumping set of 75 HP complete all as specified and directed by the Engr - in Charge. | 1 | Each | |
| 104 | 106 | Supply and fixing in repairs rubber/tyre coupling of pumping set of 5 to 7.5 HP complete all as specified and directed by the Engr - in Charge. | 2 | Each | |
| 105 | 107 | Material & labour in replacement of water pressure gauge 0-7 kg / cm2 any type Make Febig or equivant suitable makes as per appx 'B' complete all as specified and as directed by the Engr-in Charge. | 10 | Each | |
| 106 | 108 | Material & labour for replacement of Digital AC Voltmeter input 0-60 VAC,Range1%-150% of input complete all as specified and as directed by the Engr-in Charge. | 8 | Each | |
| 107 | 109 | Material & labour for replacement of Digital AC Ammeter input programmable (1A to 5A) Range2%-12% of input complete all as specified and as directed by the Engr-in Charge. | 8 | Each | |
| 108 | 110 | Material & labour for replacement of Indicating Light, 240V AC, LED Type Red, Yellow, Blue complete all as specified and as directed by the Engr-in Charge. | 12 | Each | |
| 109 | 111 | Material & labour for replacement of Mushroom head Push Button, Press to Lock Turn To Release complete all as specified and as directed by the Engr-in Charge. | 10 | Each | |
| 110 | 112 | Material & labour for replacement of ON/OFF Push Button complete all as specified and as directed by the Engr-in Charge. | 8 | Each | |
| 111 | 113 | Material & labour for replacement of Timer GIC star/delta complete all as specified and as directed by the Engr-in Charge. | 4 | Each | |
| 112 | 114 | Material & labour for replacement of DG SET self of DG SET capacity upto 125 KVA, make- Lucas, Bosch, with 12 V DC system all as specified and as directed by the Engr-in Charge. | 2 | Each | |
| 113 | 115 | Material & labour for General servicing and calliberation of fire Fighting system panel of capacity of pump 100 HP with complete testing of power supply cable including lug connection, contactor trip circuit, measuring meter calliberation, No NC point cleaning, complete control wiring repair, relay and trip circuit, maint and all connected accessories regarding serviceability of fire fighting system and testing of system in presence of and upto the entire satisfaction of Engr in charge. | 1 | Each Job | |
| 114 | 116 | General servicing and routine check up of passenger lift of capacity of 5 person for every Quarter or any unserviceability of lift to ensure the serviceability of lift cosisting of following Job:- 1) it will provide emergency services for break down as and when required on priority basis. 2) user complain will be attended on priority basis. 3) time to time general check up of the lift during contract period. \nNote:- (a) For servicing contractor will provide manufacturer service engineer for passenger lift and testing of the same in the presence of engineer in charge.\n(b) Items to be replaced in general servicing shall be paid as supply only. | 4 | Each Job | |
| 115 | 117 | Supply only door sensor | 1 | Each | |
| 116 | 118 | Supply only FLOOR sensor | 1 | Each | |
| 117 | 119 | Supply only LIFT INDOOR LIGHT | 2 | Each | |
| 118 | 120 | Supply only LIFT INDOOR EXHAUST FAN | 2 | Each | |
| 119 | 121 | Supply only limit switch | 2 | Each | |
| 120 | 122 | Supply only cabin floor indicatiing push button mechanism for G+3 Lift | 1 | Each Set | |
| 121 | 123 | Material & labour for Repair of door setting mechanism of lift for proper opening and closing mechanism as directed by engineer in charge | 1 | Each job | |
| 122 | 124 | Material & labour for repair of lift cabin setting mechanism of lift for proper allignment to every floor for safety as directed by eng in charge | 1 | Each job | |
| 123 | 125 | Material & labour in replacement of industrial battery charger FCBC (FLOAT CUM BOOST CHARGER) for charging of lead acid battery of any capacity for 12V DC capacity. Make:-Maha Maya Engineers, NHP or equivellent as approved by GE. The battery charger should have following properties:-\n(1) input voltage 220V AC single phase,+/- 20%\n(2) output voltage 12V ,24 V DC\n(3) output current 10A, 20A\n(4) Protection:-over charge and Rev battery\n(5) Indications for Mains on fail, Charger on fail, auto/manual/boost/float, high voltage chager trip, low voltage load trip\n(6) audio alarm for faults | 1 | Each | |
| 124 | 126 | Material and labour for radium marking of RMU units, LT panels, bus bar panels with radium paint of red color including writing of description of supply, incoming and outgoing with general information all as directed by engrineer in charge. | 100 | Each Job |