Providing Cantilever Gantry Board , Metal Crash Barrier , Solar Led Blinker And Thermoplastic Paint In Other District Roads In Respect Of Thanjavur H Candm Division ., Thanjavur-Tamil Nadu
TDR : 24581906
Tender Notice
Corrigendum Details
BOQ
Expired
Thanjavur
Tamil Nadu
Corrigendum : Providing Cantilever Gantry Board , Metal Crash Barrier , Solar Led Blinker And Thermoplastic Paint In Other District Roads In Respect Of Thanjavur H Candm Division .
Schedule A for the Work of Providing Cantilever Gantry board, Metal Crash Barrier, Solar LED Blinker and Thermoplastic paint in Other District Roads in respect of Thanjavur (H), C&M Division PACKAGE–110Road 1 -Providing Cantilever Gantry board at km 0/2 of Thalavapalayam - Kulichapattu road including solar LED BlinkerRoad 2 -Providing Cantilever Gantry board at km 1/4 of Vallam - Kallaperambur road including solar LED BlinkerRoad 3 -Providing Cantilever Gantry board at km 0/2 of Kurungulam union road including solar LED BlinkerRoad 4 -Providing Cantilever Gantry board at km 0/2 of Vallam - Pudur Road including solar LED BlinkerRoad 5 -Providing Cantilever Gantry board at km 4/4 of Kurungulam union road including solar LED BlinkerRoad 6 -Providing Cantilever Gantry board at km 0/2 of Chellappanpettai road including solar LED BlinkerRoad 7 -Providing Cantilever Gantry board at km 6/2 (i) of Road branching from K.M 3/10 of Vallam - Kallaperambur road to Singaperumalkulam Municipal limit. including solar LED BlinkerRoad 8 -Providing Cantilever Gantry board at km 6/2(ii) of Road branching from K.M 3/10 of Vallam - Kallaperambur road to Singaperumalkulam Municipal limit. including solar LED BlinkerRoad 9 -Providing Metal crash barrier at km 0/6 of Road branching from KM 5/4 of Thanjavur - Budalur road to joint at KM 4/6 of Thanjavur - Vallam road.Road 10 -Providing Metal crash barrier at km 6/10 & 7/4 of Vallam - Kallaperambur roadRoad 11 -Providing Metal crash barrier at km 2/6 & 6/8 of Mehalathur - Pathalapettai roadRoad 12 -Providing Metal crash barrier at km 3/10 of Manayeripatti - Vendayanpatti roadRoad 13 -Providing Metal crash barrier at km 6/2 of Road branching from K.M 5/10 of Thirukkattupalli - Sengipatti - Pattukkottai road to Orathur roadRoad 14 - Providing Metal crash barrier at km 1/4 of Mahadevapuram - Katchamangalam - Maraneri roadRoad 15 -Providing Metal crash barrier at km 3/10, 4/2, 4/6 of Road branching from Cauvery right bank 58/6 of Perambalur - Manamadhurai road to Melauthamanallur roadRoad 16 -Providing Metal crash barrier at km 6/2, 6/4 & 6/6 of Left bank of Vennar - Vettar Ammanpettai - Vinnamangalam (Via) Nagathi - Thenperambur - Allur roadRoad 17 -Providing Metal crash barrier at km 1/6 & 1/8 of Nadukkavery - Kulimathur - Alisakudy- Allur roadRoad 18 -Providing Metal crash barrier at km 2/8, 4/2 of Thiruvaikkavoor - Thirupirambiyam road including solar LED BlinkerRoad 19 -Providing Metal crash barrier at km 0/4 of Keelakorukkupattu road including solar LED BlinkerRoad 20 -Providing Metal crash barrier at km 0/6 of Keelakorukkupattu road including solar LED BlinkerRoad 21 -Providing Metal crash barrier at km 0/8 of Keelakorukkupattu roadRoad 22 -Providing Metal crash barrier at km 0/10 of Keelakorukkupattu roadRoad 23 -Providing Metal crash barrier at km 1/2 of Keelakorukkupattu roadRoad 24 -Providing Metal crash barrier at km 1/0-1/100 of Km 6/10 of Kumbakonam - Kollidakarai road at Neelathanallur to Melanamedu road (Via) Devanacherri roadRoad 25 -Providing Metal crash barrier at km 1/100-1/200 of Km 6/10 of Kumbakonam - Kollidakarai road at Neelathanallur to Melanamedu road (Via) Devanacherri roadRoad 26 -Providing Metal crash barrier at km 1/200-1/300 of Km 6/10 of Kumbakonam - Kollidakarai road at Neelathanallur to Melanamedu road (Via) Devanacherri roadRoad 27 -Providing Metal crash barrier at km 1/300-1/400 of Km 6/10 of Kumbakonam - Kollidakarai road at Neelathanallur to Melanamedu road (Via) Devanacherri roadRoad 28 -Providing Metal crash barrier at km 0/6, 0/8 of Road Branching from 26/8 of Kumabonam - Kudavasal road to Senbagakollai roadRoad 29 -Providing Metal crash barrier at km 1/2 of Nagarasampettai roadRoad 30-Providing Metal crash barrier at km 1/4 of Nagarasampettai road
Sl.No.
Item Description
Item Code / Make
Quantity
Units
1
1
Providing and erecting Single sided Double Guard Metal Beam Crash Barrier System 1.70m high, comprising of 3mm thick wall “W” beams posts and spacer channels shall be made by cold roll forming using HR confirm to IS 5986 FE 410/360 and dip galvanized having Zinc Mass of 550gms/sqm, minimum 950mm above road/ ground level fixed on ISMC series channel vertical post 150x75x5mm spaced 2m center to center 312mmx83mm flange width x 3mm thick, 4318mm long post directly embedded in the concrete (M15) pit size 350x350x800mm for a depth of 750mm below ground. All fixing bolts and nuts hot dip galvanized confirming to IS:1367 clause 4.60 all complete as per Technical Specification and as directed by the Engineer – in – charge.
2
1.01
Road 9
80
Running metre
3
1.02
Road 10
70
Running metre
4
1.03
Road 11
122
Running metre
5
1.04
Road 12
94
Running metre
6
1.05
Road 13
94
Running metre
7
1.06
Road 14
92
Running metre
8
1.07
Road 15
140
Running metre
9
1.08
Road 16
140
Running metre
10
1.09
Road 17
90
Running metre
11
1.1
Road 18
128
Running metre
12
1.11
Road 19
128
Running metre
13
1.12
Road 20
128
Running metre
14
1.13
Road 21
142
Running metre
15
1.14
Road 22
142
Running metre
16
1.15
Road 23
142
Running metre
17
1.16
Road 24
92
Running metre
18
1.17
Road 25
84
Running metre
19
1.18
Road 26
84
Running metre
20
1.19
Road 27
84
Running metre
21
1.2
Road 28
42
Running metre
22
1.21
Road 29
140
Running metre
23
1.22
Road 30
140
Running metre
24
1.23
Road 31
140
Running metre
25
1.24
Road 32
140
Running metre
26
1.25
Road 33
140
Running metre
27
1.26
Road 34
140
Running metre
28
1.27
Road 35
140
Running metre
29
1.28
Road 36
140
Running metre
30
1.29
Road 37
140
Running metre
31
1.3
Road 38
140
Running metre
32
1.31
Road 39
140
Running metre
33
1.32
Road 40
140
Running metre
34
1.33
Road 41
140
Running metre
35
1.34
Road 42
140
Running metre
36
1.35
Road 43
140
Running metre
37
1.36
Road 44
140
Running metre
38
1.37
Road 45
140
Running metre
39
1.38
Road 46
138
Running metre
40
1.39
Road 47
140
Running metre
41
1.4
Road 48
134
Running metre
42
1.41
Road 49
140
Running metre
43
1.42
Road 50
130
Running metre
44
1.43
Road 53
40
Running metre
45
1.44
Road 54
126
Running metre
46
1.45
Road 55
70
Running metre
47
1.46
Road 56
136
Running metre
48
1.47
Road 60
142
Running metre
49
2
Providing and fixing of Digitally Printed Retro-Reflectorized Overhead Cantilever Gantry Informatory Sign Board made out of cube corner Micro Prismatic grade sheeting of Type XI standards of IRC67 - 2012 and ASTM D 4956 - 09 specification, Digitally Printed using Latex Printer for traffic color logos/ text and laminated with clear electro-cuttable film and applied to properly prepared sign substrates, fixed over 2mm thick aluminum sheet with back supporting frame of size 50mm x 50mm x 6mm MS angle and supported on a vertical post of 300 NB (Nominal Bore) MS pipe of 12 mm thick with a ground clearance of 6meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20 mm thick support posts. The sign board should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed substructure and foundation with Reinforced Cement Concrete M20 grade column (1.25m x 1.25m x 1.90m) and footing (1.80m x 1.80m x 0.30m) with Fe 500 steel over Plain Cement Concrete M15 grade levelling course of 100 mm thick. The minimum depth of foundation shall not be less than 2.00m. 1 number of MS Base plate of size 1200mm x 1200mm x 25mm with Anchor bolts of 25mm dia and 1000mm length, 2 numbers of MS Top plates of size 900mm x 2100mm x 16mm with suitable bolts, nuts and washers, suitable numbers of MS stiffener plates of 8mm thick are to be used to hold the sign board at the bottom and top respectively including cost and conveyance of all materials, equipment, machinery and labour with all leads and lifts, loading charges and fixing the overhead cantilever sign board in position, etc., for satisfactory completion of the work as per structural and foundation drawings approved by the competent authority and as directed by the Engineer-in-charge. The micro prismatic grade retro-reflector sheet should have minimum co-efficient of Retro-reflection values as per Table 6.9 of IRC 67¬2012. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance as per IRC 67-2012 and a certified copy of 3 years outdoor exposure report shall be obtained. The warranty shall be inclusive of digitally printed logos/text/legends and their bonding to the retro-reflective sheeting (as per MoRT&H specification No.801). The Latex printer used for digital printing should be used with inks of low VOC emissions and should have green guard, eco logo certificates as per UL 2801 standards.\nDigitally Printed Retro-Reflectorized Overhead Cantilever Gantry Informatory Sign Board of size 5.00m x 1.80m
50
2.01
Road 1
1
Numbers
51
2.02
Road 2
1
Numbers
52
2.03
Road 3
1
Numbers
53
2.04
Road 4
1
Numbers
54
2.05
Road 5
1
Numbers
55
2.06
Road 6
1
Numbers
56
2.07
Road 7
1
Numbers
57
2.08
Road 8
1
Numbers
58
2.09
Road 51
1
Numbers
59
2.1
Road 52
1
Numbers
60
2.11
Road 57
1
Numbers
61
2.12
Road 58
2
Numbers
62
2.13
Road 59
2
Numbers
63
3
Providing end fixing LED Solar Blinker of dimension not less than 300mm in diameter made of unbreakable polycarbonate body with either Amber, Red or Blue color, Wattage should be al 12w and the operating voltage is 12v. The LED bulbs used should not be less than 176 nos. wilts 5mm pitch with high brightness, with 40 blinks per minute controlled by a Micro controller of 12v/5A. The solar blinker must be powered by a solar panel with 40w and 113Ah SMF battery capacity and a retro-reflectorized hazard marker to be used as a back support with LED strip Wiring provided for additional visibility. The solar blinker is erected on a 4 Meter MS Pole powder coated pipe of 3 inch diameter and 2.5mm thickness firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmx45cmx60crn size including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete.\nSolar LED Blinker
64
3.01
Road 1
1
Numbers
65
3.02
Road 2
5
Numbers
66
3.03
Road 4
1
Numbers
67
3.04
Road 18
2
Numbers
68
3.05
Road 19
2
Numbers
69
3.06
Road 20
2
Numbers
70
4
Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from Streaks and holes etc complete as per MORT&H specification No.803
71
4.01
Road 1
6.3
Square metre
72
4.02
Road 2
5.3
Square metre
73
4.03
Road 3
9.3
Square metre
74
4.04
Road 4
7.3
Square metre
75
4.05
Road 5
9.3
Square metre
76
4.06
Road 6
12.3
Square metre
77
4.07
Road 7
9.3
Square metre
78
4.08
Road 8
9.3
Square metre
79
90
Calculation of SubTotal, GST and Total Amount carried out by system automatically
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.