Public Works Department-PWD has published Modernization/Upgradation Of Assam Engineering College At Jalukbari , Guwahati-13 ( Phase-I ) Under The Tejasvi Navadhitamastu Edu-Infra Funds ( Tneif ) . Gr-V ( Modernization Of Works Of Mechanical Engg . Deptt ( New Rcc 2 ( Two ) Storied Bldg. Submission Date for this Tender is 22-07-2020. Building Work Tenders in Jalukbari Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Jun-2020 | Extension Notice | Date | 14-07-2020 |
2 | 13-Jul-2020 | Extension Notice2nd | Date | 22-07-2020 |
3 | 22-Jul-2020 | Order | Technical Bid | 22-07-2020 |
Name of Work: Modernization/Upgradation of Assam Engineering College at Jalukbari, Guwahati-13 ( Phase-I) under the TEJASVI NAVADHITAMASTU EDU-INFRA FUNDS (TNEIF) . Gr-V( Modernization of works of Mechanical Engg. Deptt( new RCC 2 ( two ) storied Bldg.) )” | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil\n | item1 | 400.357 | m3 |
2 | 2 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | item2 | 684 | m3 |
3 | 3 | Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | item3 | 760 | m2 |
4 | 4 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volume\n | item4 | 115.469 | m3 |
5 | 5 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | item5 | 114 | m2 |
6 | 6 | Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 \nC) UNIFORM PILE\nd) Pile Dia 400 mm\nii) Above 10 M | item6 | 2688 | RM |
7 | 7 | Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc)\n(A) TMT bar made of Primary producer (From Primary producer) | item7 | 255.606 | Qtl. |
8 | 8 | b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)\n (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. . | item8 | 0.72 | Qtl |
9 | 9 | Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load) | item9 | 50 | TON |
10 | 10 | Providing & laying reinforcement cement concrete works in prop 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work. (form work and reinforcement will be measured and paid separately)\n(I) Using Mixture machine\n(A) In Sub-Structure up-to Plinth Level Foundation, footings, columns with base, tie & plinth beam, pile cap, base slab retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level.\n(b) M20 or Prop 1:1.5:3 | item10 | 346.089 | m3 |
11 | 11 | (A) In Sub-Structure up-to Plinth Level Foundation, footings, columns with base, tie & plinth beam, pile cap, base slab retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level.\n(a) M20 or Prop 1:2:4 | item11 | 0.641 | m3 |
12 | 12 | (b) M20 or Prop 1:1.5:3 | item12 | 23.085 | m3 |
13 | 13 | (ii) Columns , Pillars , posts, struts , suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer , cantilever, stair case ( except spiral stair case and landing) including preparing the top surface & finishing of nosing.\n(b) M20 or Prop 1:1.5:3 | item13 | 255.918 | m3 |
14 | 14 | 2.2.3 Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level. | item14 | 259.83 | m3 |
15 | 15 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement bar | item15 | 268.56 | Qtl. |
16 | 16 | Providing from work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\n\nColumns, pillars, posts & strut of square / rectangular /polygonal in plan or any shape like Tee/L etc. havingplane vertical face. | item16 | 403.2 | m2 |
17 | 17 | Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\n(a) For depth not exceeding 1.0M | item17 | 370.34 | m2 |
18 | 18 | Flat Surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies and the like .\n(a) Floors etc. upto 200mm in thickness. | item18 | 382.04 | m2 |
19 | 19 | Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. | item19 | 288 | m2 |
20 | 20 | Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.2.1&3.2.3.(b) | item20 | 3242.17 | m2 |
21 | 21 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. | item21 | 304.01 | m2 |
22 | 22 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4. | item22 | 88.389 | m3 |
23 | 23 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(a) In proportion 1:3. | item23 | 4.023 | m3 |
24 | 24 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | item24 | 1.97 | sqm |
25 | 25 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).\n(ii)In Superstructure above plinth level upto 1st floor level. | item25 | 106.25 | Cum |
26 | 26 | Extra for AAC block walling of each subsequent floor or part therof above the 1st floor level. | item26 | 106.25 | Cum |
27 | 27 | Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc. Complete as directed by the department for all levels. (P.C.C. to be measured and paid for separately).\n\n\n(a) 1.25mm thick sheet\n(iii) Size 125mm x 60mm (Single rebate) | item27 | 30.8 | Rm |
28 | 28 | Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws.\na) Decorative type face panel and block board core.\n(i) 40 mm thick . | item28 | 8.4 | m2 |
29 | 29 | b) Non decorative type and block board core.\n(i) 40 mm thick . | item29 | 15.12 | m2 |
30 | 30 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered) | item30 | 115.2 | Kg. |
31 | 31 | Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete etc complete as specified and directed by the department at all levels.\n(a) with 12 mm thick toughened glass | item31 | 4.41 | m2 |
32 | 32 | Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately).\na)Side hung and Top hung windows and ventilators\ni) 6 mm clear glass | item32 | 30 | m2 |
33 | 33 | Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(b)3 Track sliding window\n(i)6mm clear glass | item33 | 44 | m2 |
34 | 34 | Providing, fitting and fixing aluminium curtain wall on the exterior face of building fitting to concrete member by drilling hole fixing by brass screw fabricated with coloured anodised aluminium section of approved brand 101mm x 55mm x 2mm by providing jointing angles including providing coloured reflectory type glass 6mm thick fitted with aluminium at all levels. | item34 | 19.44 | Sqm |
35 | 35 | Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.\n(a) 15 mm thick | item35 | 24.22 | m2 |
36 | 36 | 15 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. | item36 | 850 | m2 |
37 | 37 | 12 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. | item37 | 850 | m2 |
38 | 38 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\nc) In cement mortar 1:5 | item38 | 760 | m2 |
39 | 39 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.\nA) On rough side\nc) In cement mortar 1:5\n | item39 | 760 | m2 |
40 | 40 | B) On fair side\nb) In cement mortar 1:4 | item40 | 24.22 | m2 |
41 | 41 | Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed.\nii) 15 mm thick plaster\nb) In cement mortar 1:4 | item41 | 24.22 | m2 |
42 | 42 | Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.\na) On Single coat plaster | item42 | 760 | m2 |
43 | 43 | Providing, fitting and fixing M.S. Grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, square or round M.S. Bars with round headed bolts and nuts or screws.\nI . Plain grill\n(c) Fixed to Brickwork/P.C.C/R.C.C. | item43 | 660 | Kg |
44 | 44 | Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint. | item44 | 21.6 | m2 |
45 | 45 | Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.\n | item45 | 760 | m2 |
46 | 46 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.\nc) 50mm thick | item46 | 760 | m2 |
47 | 47 | 18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.\n(IV) Rajnagar Slab | item47 | 4.41 | m2 |
48 | 48 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\na) Normal range \nii) Of size 600mmx600mm and above | item48 | 127.6 | m2 |
49 | 49 | Providing and laying 50mm thick C.C. floor with metallic concrete hardener topping under layer of 35 mm thick cement concrete in prop.1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 20 mm and down) and top layer of 15mm thick of metallic cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm and down) by volume with which metallic hardening compound of approved quality is mixed in the ratio of 4:1 (4 parts of cement : 1 part of metallic floor hardening compound of approved quality by weight) including finishing with curing complete as directed. | item49 | 730 | m2 |
50 | 50 | Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).\ni) Of size 300mmx450mm and above | item50 | 14 | m2 |
51 | 51 | Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\n(A) CERAMIC \niii)Executive range-2 (Sizes 600 mm x 600mm and above)\nSomany made- VC Shield (Group- 25) (605x605) mm\na) Deluxe -VC | item51 | 27 | m2 |
52 | 52 | Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. | item52 | 270 | m2 |
53 | 53 | Providing drain with cement concrete (1:3:6)10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cem,ent plastering in prop 1:3: finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified .\n(i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.\n | item53 | 180 | rm |
54 | 54 | PLASTER OF PARIS & WALL PUTTY\nProviding two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick | item54 | 850 | m2 |
55 | 55 | WALL PAINTING \nWall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | item55 | 850 | m3 |
56 | 56 | Extra over item no 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).\n(i).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | item56 | 425 | m2 |
57 | 57 | EXTERIOR PAINTS / COATINGS\nApplying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. | item57 | 425 | m2 |
58 | 58 | Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. | item58 | 425 | m2 |
59 | 59 | Applying primary coat over new steel and other metal surface upto 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed "red-lead/ red oxide" primer. | item59 | 1360 | Rm |
60 | 60 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(ii).Surfaces up to 100mm in width or girth.\na). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | item60 | 1402.75 | Rm |
61 | 61 | Supplying, fitting, fixing electrocoloured iron fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete.\n(a) Sliding door bolts i) 300mm x 16mm | item61 | 45 | Nos |
62 | 62 | (b) Tower bolts (ii) 250mm x 12mm | item62 | 120 | Nos |
63 | 63 | d) MS door handles (ii) 150mm | item63 | 90 | Nos |
64 | 64 | g) MS butt hinge \nI) Heavy type\ni) 50mm x 40mm x 2.5mm | item64 | 60 | Pair |
65 | 65 | ii) 75mm x 60mm x 3.15 | item65 | 31 | Pair |
66 | 66 | Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department.\nA) Godrej\na) Single Speed Door Closer( size166.5x 48mmx 67mm)-Model C071 | item66 | 12 | Each |
67 | 67 | Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. \nCeiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). \n\n\n(ii)12.5mm thick | item67 | 56 | m2 |
68 | 68 | Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.\n(a) Within Guwahati city only | item68 | 4020 | cum |
69 | 69 | Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) \n(a)Using Grading I material | item69 | 213.75 | cum |
70 | 70 | Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD. | item70 | 862.5 | sqm |
71 | 71 | Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 2878 with ISI Mark.(4.5 LITERS) \nBRAND: FIRESTOP / FIREND / FIRESHIELD | item71 | 5 | each |
72 | 72 | Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark\n(05 kg capacity) \nBRAND : FIRESTOP / FIREND / FIRE SHIELD | item72 | 5 | each |
73 | 73 | Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\nA) Parryware make\na) White\n(i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover) | item73 | 19 | each |
74 | 74 | Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\ni) Parryware make\na) White\n(iv) Deluxe Dual Flush (Cat No.C8110) | item74 | 19 | each |
75 | 75 | Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\n(A) Parryware Make\n(a) White\n(i) New Magnum (Cat. No.C0575) | item75 | 16 | Each |
76 | 76 | Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\nBasin (without pedestal)\n(A) Parryware Make\n(a) White\n(i) Star Basin 550 x 400 (Cat. No.C0450) | item76 | 10 | Each |
77 | 77 | Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified. | item77 | 10 | nos |
78 | 78 | Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.\n(i) Jaquar Make\n(a) Continental (Cat.No.ACN-1331N) | item78 | 19 | each |
79 | 79 | Providing, fitting and fixing CP towel rail complete as directed and specified.\n(b) Sona make \n(i) Towel rail Diplomat 300mm long (Cat.No.TR-0605) | item79 | 19 | nos |
80 | 80 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.\na) In exposed surfaces or in trenches.\n(ii) 110mm dia.\n \n | item80 | 15 | nos |
81 | 81 | Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches.\n(ii) 110mm dia. | item81 | 18 | nos |
82 | 82 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches.\n(ii) 110mm dia.\n | item82 | 16 | nos |
83 | 83 | Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches.\n(ii) 110mm dia.\n | item83 | 15 | nos |
84 | 84 | Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed.\nviii) 100 Users\n | item84 | 4 | nos |
85 | 85 | Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified | item85 | 8 | nos |
86 | 86 | Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | item86 | 18 | nos |
87 | 87 | Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 100mm dia. | item87 | 100 | rm |
88 | 88 | Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.\ni) Bore hole of 75mm diameter\n\n | item88 | 150 | Rm |
89 | 89 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.\n(I) G.I. pipe\na) TATA / SAIL (Medium) socket should be welded to the pipes.\ni) 50mm diameter\n | item89 | 150 | Rm |
90 | 90 | Supplying fitting and fixing GI filter 2.00 metre long.\n | item90 | 2 | Nos |
91 | 91 | Supplying fitting and fixing check valve (non return valve) including thread to pipes.\niii) 40mm diameter\n | item91 | 1 | Nos |
92 | 92 | Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained | item92 | 1 | Job |
93 | 93 | Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes\n(iii) 1000 Lt capacity\n(a) Sintex make | item93 | 4 | Nos |
94 | 94 | Labour for erecting and placing PCVCTank over the stagging of 5.00m up to 8.00m complete as directed.\n(c) 1000 litre capacity\n | item94 | 4 | Nos |
95 | 95 | Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. \n(A) Exposed on walls\nb) 40 mm dia (Medium)\ni) Using Tata make\n | item95 | 65 | Rm |
96 | 96 | d) 25 mm dia (Medium)\ni) Using Tata make\n | item96 | 35 | Rm |
97 | 97 | f) 15 mm dia (Medium)\ni) Using Tata make\n | item97 | 45 | Rm |
98 | 98 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately)\n(ii) Jaquare make \n(ii) Bibcock long thread\n | item98 | 80 | nos |
99 | 99 | Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately)\nI) Brass stop cock (heavy) of Sant make\n(v) 40mm dia | item99 | 12 | nos |
100 | 100 | (iii) 25mm dia | item100 | 12 | nos |
101 | 101 | Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately)\n(II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)\n | item101 | 36 | nos |
102 | 102 | Supplying and placing Ferrocement Iron Removal Plant over stagging with movabale G.I. Sheet cover with side ventilation including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging and storage reservoir should be measured and paid separately). \n(i) 1000 lt capacity \n | item102 | 4 | Nos |
103 | 103 | Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 38 Kg. weight complete as directed and specified | item103 | 2 | each |
104 | 104 | Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete\n SP upto 3.00 metre length. | item104 | 74 | point |
105 | 105 | MP upto 6.00 metre length. | item105 | 50 | point |
106 | 106 | LP upto 10.00 metre length. | item106 | 80 | point |
107 | 107 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.\n SP upto 3.00 metre length. | item107 | 15 | point |
108 | 108 | MP upto 6.00 metre length. | item108 | 15 | point |
109 | 109 | LP upto 10.00 metre length. | item109 | 30 | point |
110 | 110 | Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) \nSP upto 3.00 metre length. | item110 | 8 | point |
111 | 111 | MP upto 6.00 metre length. | item111 | 8 | point |
112 | 112 | LP upto 10.00 metre length. | item112 | 8 | point |
113 | 113 | Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item113 | 700 | mtr |
114 | 114 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item114 | 2350 | mtr |
115 | 115 | With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item115 | 280 | mtr |
116 | 116 | With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item116 | 160 | mtr |
117 | 117 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item117 | 80 | mtr |
118 | 118 | With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item118 | 80 | mtr |
119 | 119 | Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item119 | 24 | Each |
120 | 120 | Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item120 | 60 | Each |
121 | 121 | Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item121 | 24 | Each |
122 | 122 | Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item122 | 264 | Each |
123 | 123 | Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.\n3 module | item123 | 60 | Each |
124 | 124 | 6 module | item124 | 16 | Each |
125 | 125 | 12 module | item125 | 10 | Each |
126 | 126 | Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.\n3 module | item126 | 60 | Each |
127 | 127 | 6 module | item127 | 16 | Each |
128 | 128 | 12 module | item128 | 10 | Each |
129 | 129 | Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item129 | 20 | Each |
130 | 130 | Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp | item130 | 4 | Each |
131 | 131 | Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-DN 394B LED 16 S -6500 PSU WH / MV1857RLOO / MV1840RLOO /MV1830RLOO / MV1830RLOO / MV1857R500 / MV1857R500 / MV1840RLOO / CRDL11R023HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / LT / Wipro make). | item131 | 28 | Each |
132 | 132 | Supplying fitting & fixing of LED Kubik Batten tube light fitting 300mm length as required and as directed by the department ( Jaquar or eqvt. make).\nkubik Series Batten tube fitting 10W | item132 | 8 | Each |
133 | 133 | Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.\nBN 021C LED 20 S PSU CW GR S2 | item133 | 100 | Each |
134 | 134 | Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten / angle holder as required and as directed by the department ( Jaquar or eqvt. make).\nPrima Series Bulb 12W | item134 | 4 | Each |
135 | 135 | Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete. | item135 | 4 | Each |
136 | 136 | Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required. | item136 | 4 | Each |
137 | 137 | Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete. | item137 | 80 | Mtr |
138 | 138 | Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)\nEnergy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make | item138 | 60 | Each |
139 | 139 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\nPower Flow 225 mm sweep (ORIENT make) | item139 | 4 | Each |
140 | 140 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \n ABB, Schneider MG, legrand, Hager make)\n 12 way SPN double door | item140 | 2 | Each |
141 | 141 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n 4way TPN (4+12) double door | item141 | 4 | Each |
142 | 142 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series\n(Schneider MG, legrand, Hager make)\n6-32A | item142 | 60 | Each |
143 | 143 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n 100/300mA sensitivity 4P RCCB\n(ABB, Schneider MG, legrand, Hager make)\n40A | item143 | 2 | Each |
144 | 144 | 63A | item144 | 4 | Each |
145 | 145 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n30mA sensitivity DP RCCB\n(ABB, Schneider MG, legrand, Hager make)\n40A | item145 | 2 | Each |
146 | 146 | Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)\n Core - 3 & 1/2 A2XWY A2XFY\n 70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe | item146 | 40 | Mtr |
147 | 147 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:\n1. 20mm X 3mm4 strip copper Bus-Bar 0.6 M length each \n2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no\n3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no\n4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no\n5. Voltmeter & Ammeter Selector Switch - 2 no\n6. 2 A Slide fuse unit - 3nos\n(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) | item147 | 1 | Each |
148 | 148 | Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series (ABB, Schneider MG, legrand, Hager make)\n63A | item148 | 4 | Each |
149 | 149 | 25 KA 415V 50 Hz 3P MCCB \n(Schneider, legrand, Siemens make)\n125A | item149 | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail