Repair/Maintenance Of Internal Electric Supply System ( Day To Day Maintenance ) At Dronachal Top Bhopal, GE Dronachal-Madhya Pradesh

Military Engineer Services has published Repair/Maintenance Of Internal Electric Supply System ( Day To Day Maintenance ) At Dronachal Top Bhopal. Submission Date for this Tender is 14-07-2020. Bolts Tenders in GE Dronachal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24529999
Corrigendum : Repair/Maintenance Of Internal Electric Supply System ( Day To Day Maintenance ) At Dronachal Top Bhopal
Tender
Indian
Madhya Pradesh
Ge Dronachal
14-07-2020

Tender Details

Repair / Maintenance Of Internal Electric Supply System ( Day To Day Maintenance ) At Dronachal Top Bhopal , Supply And Replacement Of Switch Piano Type Flush Type Single Pole One Way 5 Amps , Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Socket Outlet 5 Pin Flush 6 Amps Multi Pin 2 / 3 Pin Complete All As Specified And Directed By Engr-In-Charge . , S&F Switch Socket Combination Flush Type 250 Volts 5 Amps Multipurpose Complete All As Directed . , Supply And Replacement Of Switch Socket Combined Outlet 6 Pin Flush 15 Amp Multi , Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Bell Push Flush Type Sp 5 Amp Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Bell Multi Music Type Single Phase Suitable For 220 V Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Modular Switch Single Pole One Way 6 Amps , Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Modular Socket 6 Amps , 2 Module Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Modular Switch Single Pole One Way 16 Amps , Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Modular Soctet 16 Amps , 02 Module Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Cfl 36 Watts 4 Pin Type ( Base 2G-11 ) , 240V , 6500K Colour Temp , 2900 Lumen . , S & F In Repairs Electronic Ballast 36 / 40 Watt Suitable For Cfl-L / Ftl Lamps For 2 X 36 Watts / 4X36 Watt , Having Input Voltage 240 Volts , 50 Hz . , S & F In Repairs Mcb Db Spn 230 Volts 200 Amps Rated Busbar 8 Way Double Door Complete All As Specified And Directed By Engr-In-Charge . , S&F In Repairs Mcb Db Tpn 4 Way With 100 Amp Mccb As Incomer ( Vertical Type Double Door , 100 Amps Mccb Rate Inclusive ) Complete All As Specified And Directed By Engr-In-Charge . , Supply And Fixing In Repairs Of Mcb Tpn 63 Amps , 415 V With Thimble Suitable For Existing Wires Complete All As Specified And Directed By Engr-In-Charge . , Supply And Fixing In Repairs Of Mcb Single Pole 6 To 32 Amps240 V With Thimble Suitable For Existing Wires Complete All As Specified And Directed By Engr-In-Charge . , Supply And Fixing In Repairs Of Mcb Single Pole With Neutral 240 Volts 6 To 32 Amps With Thimble Suitable For Existing Wires Complete All As Specified And Directed By Engr-In-Charge . , Supply And Fixing In Repairs Of Mcb Single Pole With Neutral 240 Volts 32 To 63 Amps With Thimble Suitable For Existing Wires Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Lamp Holder , Pvc / Poly Carbonate Type With Back Plate Suitable For Batten Fittings Complete All As Specified And Directed By Engr-In-Charge . , S&F , In Replacement , Electronic Ballast Suitable For 36 / 40 Watt Flourescent Tube 230V Ac , 50 Hz Pf<0 . 94 ( Pre Wired Type ) ( Provided With Extra Wires ) To Be Suitable For Installation In Place Of Copper Wound Vpti Ballast . Complete All As Specified And Directed By Engr-In-Charge . , Supply And Fixing In Replacement Of Sheet Metal Enclosures With Socket Plug Top And Mcbs With Two Pin And Earth Plug And Socket Complete With One Double Pole Mcb 240 V Grade 20 Amp . ( A / C Box ) Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Plastic Laminated Sheet Cover Isi Marked With Required Nos Of Space For Switches / Sockets / Regulator Of Size 250X280mm Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of Plastic Laminated Sheet Cover Isi Marked With Required Nos Of Space For Modular Switches / Sockets / Regulator Of Size 250X280mm Complete All As Specified And Directed By Engr-In-Charge . , Supply And Replacement Of 3 Pin Plug Top Ac-230V , 15 Amp Complete All As Specified And Directed By Engr-In-Charge . , Taking Down Carefully Copper & Aluminum Point Wiring For Light , Fan , Socket Or Power Complete And Making Good Distrubuted Surfaces Of Walls Floors Etc . Including Switch & Socket Etc Complete All As Specified And Directed By Engr-In-Charge . , M & L For Point Wiring With 1 . 5 Sqmm Multi Stranded Frls Copper Conductor 1100 V Grade Pvc Insulated Unsheathed Cable Drawn In & Including Pvc Casing Caping , Isi Marked With All Accessories ( Casing Caping As Approved By Eic ) With Pvc 1 . 5 Sqmm Multi Stranded Insulated Unsheathed Copper Wire For Continous Earth , Including Sunk In Cast Iron / Ms Terminal Box Duly Painted With Aluminum Paint Inside And Anticorrosive Paint Out Side With 2 . 8 Mm Thick Backlite Sheet Cover For Mounting Switch & Sockets For The Following:- Complete All As Specified And Directed By Engr-In-Charge . ( Note : Colour Code Wiresas Specified To Be Used For Wiring ) , One Light / Fan / Cal Bell Point Controlled By One Switch . , One 3 Pin Socket Outlet 5 Amps On Independent Board . , One 3 Pin Socket Outlet On Same Board . , M & L For Point Wiring With 4 Sqmm Multi Stranded Frls Copper Conductor 1100 V Grade Pvc Insulated Unsheathed Cable Drawn In & Including Pvc Casing Caping Isi Marked With All Accessories ( Casing Caping As Approved By Eic ) With Pvc 2 . 5 Mm Multi Stranded Insulated Unsheathed Copper Wire For Continous Earth With Sunkbox Of Cast Iron / Ms Terminal Box Duly Painted With Aluminum Paint Inside And Anticorrosive Paint Out Side With 2 . 8 Mm Thick Backlite Sheet Cover For Mounting Switch & Sockets For The Following & Complete All As Specified And Directed By Engr-In-Charge . , S & F 1 X 18 Watt Led Tube Light Fitting Basic All Purpose Surface And Wall Mounted Led Batten With Polycarbonate Housing & Integrated Electronic Driver , Led Decorative Luminaire With Suitable For Lamps Led Light High Efficiency Led Driver , Optimized Heat Dissipation For Ensuring High Led Life Span . , M&L For Earthing Complete With Galvanised Iron Earth Plate Electrode 60Cmx60cmx6mm Thick , Burried Directly In Ground ( Earth Pit Not Less Than 2 . 25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1 . 5 Metres Below Normal Ground Level , Connected To Galvanised Steel Wire 4 Mm Dia By Means Of Galvanised Nuts , Bolts , Check Nuts And Washers Including Excavation And Earth Work , Pcc 1:3:6 Type C-2 Pit , Pcc Pit Cover 1:2:4 Type B-1 With Handle , Gi Protection Pipe 15 Mm Bore Light Grade And 20Mm Medium Grade Gi Watering Pipe , Funnel , Wire Mesh Etc Complete As Shown In Electrical Plate No . 3 Of Ssr Part-I Connected To Earthing Test Point And Metal Part All As Specified Including Testing On Completion . , Supply And Replacement Of Ceiling Fan Regulator Isi Marked , Any Type Complete All As Specified And Directed , Supply & Fixing In Repairs Crystal Glass Led Tubelight ( Double Side Connection Tube Rod ) 1 X 18 Watt , Ultra Bright Glass Led Tubelight With Very High Efficiacy Suited For Installation In Existing T8 Tubelight With G13 Lamp Holders To Give Glare Free Light . Complete All As Specified And Directed By Engr-In-Charge . , S&F In Repairs Ceiling Rose , 3 Phase / Pvc / Polycarbonate , Isolated Body , Taking Down Carefully Aluminium Sub Main Wiring From The Existing Casing / Caping / Pvc Conduit All As Diretced . , M / L For Submain Wiring With 2 Runs Of 2 . 5 Sqmm Single Core Pvc Insulated Stranded Copper Conductor Cable Drawn Through Rigid Non Metallic Pvc Conduit With One Run Of 1 . 5 Sqmm Pvc Insulated Copper Conductor Cable As Earth Continuity Conductor And Necessary Connections All As Directed . Note : 2 Runs Of 2 . 5 Sqmm Pvc Insulated Unsheathed Copper Conductor And 1 Run Of 1 . 5 Sqmm Pvc Insulated Unsheathed Copper Conductor And 1 Run Of Pvc Conduit Of Size 25 Mm Will Be Measured As Single Run

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 07-07-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-07-2020
2 23-06-2020 Corrigendum No 1 BOQ 29-06-2020
3 27-06-2020 Corrigendum No 2 Date 07-07-2020

Key Value

Document Fees
INR 500 /-
Tender Value
INR 20 Lakhs /-
Disclaimer :