| 1 | 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. | | 120 | Sqm |
|---|
| 2 | 2 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. | | 350 | Sqm |
|---|
| 3 | 3 | Demolition of cement concrete (unreinforced) in ground floors and paving n.exc. 15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed. | | 4.5 | Cum |
|---|
| 4 | 4 | Taking down chowkats or frames with shutters with exc. 1.50 Sqm but n.exc. 4 Sqm each (without taking of shutters from the frames) complete all as specified and as directed. | | 1 | Each |
|---|
| 5 | 5 | Dismantling timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as directed | | 4.5 | Cum |
|---|
| 6 | 6 | Material and labour for 25mm thick, PCC (1:2:4), type B0, (using 12.50mm graded aggregate) as in sub base of floor and finished the surface fair and even complete all as specified and as directed. | | 185 | Sqm |
|---|
| 7 | 7 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement complete all as specified and as directed. | | 60 | Sqm |
|---|
| 8 | 8 | Material and labour for well seasoned 2nd class hard wood timber in scantlings, wrought, timber fixed complete all as specified and directed. | | 4.5 | Cum |
|---|
| 9 | 9 | Supply and fixing anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and as directed.\n | | 3.25 | Sqm |
|---|
| 10 | 10 | Supply and fixing anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.\n | | 10 | Kg |
|---|
| 11 | 11 | Supply and fixing 5.50 mm thick Sheet glass, ordinary quality in aluminium shutters complete all as specified and as directed. \n | | 3.25 | Sqm |
|---|
| 12 | 12 | Supply and fixing 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap,fixed with ’J’ type or ‘L’ type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed.\n | | 90 | Sqm |
|---|
| 13 | 13 | Supply and fixing of 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.\n | | 30 | Sqm |
|---|
| 14 | 14 | Supply and fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.\n | | 190 | Sqm |
|---|
| 15 | 15 | Supply and fixing Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners\n12.5mm dia. 40mm long complete all as specified and as directed.\n | | 190 | Sqm |
|---|
| 16 | 16 | Supply and fixing 4mm thick High Pressure Steam Cured (HPSC) Non asbestos fibre cement building boards confirming to IS 14862 fixed/ inserted to GI\nframework complete all as specified and as directed.\n | | 190 | Sqm |
|---|
| 17 | 17 | Materials and labour for preparation of surfaces of false ceiling and applying two coats of acrylic washable distemper complete all as specified and as directed.\n | | 190 | Sqm |
|---|
| 18 | 18 | Supply and fixing 6mm thick plywood, grade BWR, type BB, fixed with nails to timber frame work complete all as specified and as directed.\n | | 160 | Sqm |
|---|
| 19 | 19 | Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc and brushing with neat cement slurry 3 Kg per sqm complete all as specified and as directed. | | 185 | Sqm |
|---|
| 20 | 20 | Material and labour for 20-25 mm thick machine cut kota stone slab flooring over and including 15mm thick screed bed in cement mortar (1:4) with roughening of surface, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. | | 185 | Sqm |
|---|
| 21 | 21 | Material and labour for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.\n | | 160 | Sqm |
|---|
| 22 | 22 | Material and labour for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamal paint complete all as specified and as directed.\n | | 350 | Sqm |
|---|
| 23 | 23 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.\n | | 120 | Sqm |
|---|
| 24 | 24 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed | | 38 | Per Point |
|---|
| 25 | 25 | Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessories and PVC rectangular boxes for mounting switch, socket and fan regulator etc complete all as specified and as directed. \nNote: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.\n | | 18 | Per Point |
|---|
| 26 | 26 | .-Ditto- all as per item No 25.00 here-in-before but for 3 pin 6 amps switch socket combination on the independant board with 1.5 Sqmm cable and -ditto-. | | 8 | Per Point |
|---|
| 27 | 27 | .-Ditto- all as per item No 25.00 here-in-before but for 3 pin 6 amps switch socket combination on the same board with 1.5 Sqmm cable and -ditto-. | | 2 | Per Point |
|---|
| 28 | 28 | .-Ditto- all as per item No 25.00 here-in-before but for one 5 pin 6/16 Amps switch socket combination on independent board with 2.5 sqmm PVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor and -ditto-. | | 10 | Per Point |
|---|
| 29 | 29 | Supply and fixing Piano switch flush button single pole one way 5 Amps complete all as specified and as directed.\n | | 18 | Each |
|---|
| 30 | 30 | Supply and fixing switch socket combination 5 pin, 6 Amps, 230 volt flush type complete all as specified and as directed.\n | | 10 | Each |
|---|
| 31 | 31 | Supply and fixing switch socket combination 5 pin, 6/16 Amps, 230 volt flush type complete all as specified and as directed.\n | | 10 | Each |
|---|
| 32 | 32 | Supply and fixing ceiling rose surface bakelite three terminal 65 x 50mm complete all as specified and as directed.\n | | 3 | Each |
|---|
| 33 | 33 | S & F PVC rectangular block for mounting switches, sockets, fan regulator, etc. with 3mm thick plastic laminated sheet cover of size 250mm x 200mm x50mm deep complete all as specified and directed. | | 2 | Each |
|---|
| 34 | 34 | Supply and fixing as in replacement MCB DB SPN 8 ways double door including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.\n | | 2 | Each |
|---|
| 35 | 35 | Supply and fixing as in replacement MCB 32 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed.\n | | 2 | Each |
|---|
| 36 | 36 | Supply and fixing as in replacement MCB 6 to 32 Amps, SP, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed.\n | | 12 | Each |
|---|
| 37 | 37 | Supply and fixing for lamp holder suitable for batten fittings complete all as specified and as directed.\n | | 4 | Each |
|---|
| 38 | 38 | Supply and fixing for 1 X 10Watt, 6500K, LED lamp suitable for holder fittings complete all as specified and as directed.\n | | 4 | Each |
|---|
| 39 | 39 | Supply and fixing as in replacement for surface mounted ultra bright, glass shell, glare free, wide angle, LED tube light fitting ( LED tube and Batten) 1 X 20Watt, 230V, 1200mm, 6500K with G13 lamp holders including all accessories and connecting to celling rose with twin core 0.75mm flexible copper conductor wire/cable complete all as specified and as directed. \n | | 3 | Each |
|---|
| 40 | 40 | Supply and fixing as in replacement of LED light fitting 1x10w bulk head liminaries,IP-65, environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs including connection with twin core 0.75mm flexible copper conductor wire/cable complete all as specified and as directed. \n | | 2 | Each |
|---|
| 41 | 41 | Supply and fixing as in replacement for environmental friendly, new generation, aesthetically designed, ultra modern 2' x 2' recess mounting LED luminarie 42 W, with high brightness SMD LEDs as light source, white powder coated CRCA housing after phosphochromate treatement, suitable for Grid ceiling and including connection with twin core 0.75mm flexible copper conductor wire/cable complete all as specified and as directed. | | 9 | Each |
|---|
| 42 | 42 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through suitable size of PVC casing caping after and including taking down existing sub main wiring complete all as specified and as directed.\nNote : Three runs of 6 Sqmm cable and PVC casing-caping shall be measured as one unit.\n | | 20 | RM |
|---|
| 43 | 43 | Supply and fixing and testing PVC insulated aluminium conductor cable, 1100 Volt grade, heavy duty served with inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed, two single core stranded conductor flat or circular, 16 Sqmm, nominal cross sectional area, as in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia. suspension wire including taking down existing unserviceable service connections complete all as specified and as directed.\n | | 35 | RM |
|---|
| 44 | 44 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.\nNote: Contractor should submit earth test report to AGE(I). | | 1 | Each Set |
|---|
| 45 | 45 | Supply and fixing house service bracket (hook type) complete with 3m long GI pipe, 40mm bore, medium grade, two Nos 90 degree bends, mild steel hook stay or guy after dismantling of old unserviceable house service brackets, any type complete all as specified and directed. | | 1 | Each |
|---|