}

Addition/Alteration To Toilets And Servant Quarters In Various Omqs Alongwith Provision Of 8 . 5 Tr Ductable Ac , Isolation Transformer And Improvement Of Cfl Bollard Light With Leds At Cgwwa Centre Of Icgs Gandhinagar, ICGS GANDHINAGAR-Gujarat

Military Engineer Services-MES has published Addition/Alteration To Toilets And Servant Quarters In Various Omqs Alongwith Provision Of 8 . 5 Tr Ductable Ac , Isolation Transformer And Improvement Of Cfl Bollard Light With Leds At Cgwwa Centre Of Icgs Gandhinagar. Submission Date for this Tender is 23-06-2020. Transformer Supply Tenders in ICGS GANDHINAGAR Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

24430843
Corrigendum : Addition/Alteration To Toilets And Servant Quarters In Various Omqs Alongwith Provision Of 8 . 5 Tr Ductable Ac , Isolation Transformer And Improvement Of Cfl Bollard Light With Leds At Cgwwa Centre Of Icgs Gandhinagar
Open Tender
Indian
Gujarat
ICGS GANDHINAGAR
23-06-2020

Tender Details

Addition/alteration To Toilets And Servant Quarters In Various Omqs Alongwith Provision Of 8 . 5 Tr Ductable Ac , Isolation Transformer And Improvement Of Cfl Bollard Light With Leds At Cgwwa Centre Of Icgs Gandhinagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 58520.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: ADDITION/ALTN TO TOILETS AND SERVANT QUARTERS IN VARIOUS OMQs ALONGWITH PROVISION OF 8.5 TR DUCTABLE AC, ISOLATION TRANSFORMER AND IMPROVEMENT OF CFL BOLLARD LIGHT WITH LEDs AT CGWWA CENTRE OF ICGS GANDHINAGAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Cutting openings, through brick walls for door window, ventilator and other openings or enlarging existing openings, converting window into door openings etc or cutting out defective brick work in brick wall including removing rubbish n. exc 50 m complete all as specified 7 CUM
2 2 Cutting chases pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, shelves, cills etc and cutting chases for concealed water tubing and conduit wiring etc and making good , cutting not exc 10 cm girth in brick wall complete all as specified 35 RM
3 3 Cutting out bricks for toothing and properly bonding into old brick work and forming facing/ jambs , jointing and pointing to match existing work , new work built in CM 1:6 complete all as specified 35 SQM
4 4 Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thick, including removing rubbish off the premises complete all as directed 8.5 CUM
5 5 M&L for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in sub base of floor / paths etc complete all as specified 65 SQM
6 6 M&L for 25 mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate ) in floors complete all as specified 65 SQM
7 7 Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out for foundation in hard / dense soil complete all as specified 42 CUM
8 8 M&L for Plain Cement concrete1:4:8 (type D-2) ( using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified 0.5 CUM
9 9 M&L brick work with Fly Ash bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified 22 CUM
10 10 M&L brick work with Fly Ash bricks straight or curved on plan to any radius built in CM 1:4 complete all as specified 230 SQM
11 11 M&L for providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, RCC bands , copings etc, including form work complete all as specified 1.4 CUM
12 12 M&L for Mild steel bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified 100 KG
13 13 Taking down plastering in cement mortar on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. complete all as specified 200 SQM
14 14 M&L for rendering 15 mm thick on fair faces of brick work in CM 1:4 finished even and smooth without using extra cement complete all as specified. 260 SQM
15 15 M&L for rendering 15 mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified. 300 SQM
16 16 All as per Item no 15.00 above, but 10 mm thick rendering on ceiling surfaces in CM 1:3 complete all as specified. 125 SQM
17 17 M & L pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering / cladding to wall ,fixed with self tapping screw complete all as specified. 80 SQM
18 18 S&F rolled mild steel (angle iron) as in rafters , purlins where connected to common rafters and running rails and guides fixed with angle cleats or other cleats confirming to Fe-410-W(Gde-E-165) complete all as specified 800 KG
19 19 S&F steel window with side hung shutters on both sides to reveive glass on one side and to receive gauze on other side including projecting type hinges with steel handle on both side shutters and steel peg stay, complete with glazing bars, dovetailed or welded including taking down the existing windows all as directed 10 SQM
20 20 S&F steel ventilator with top hung shutters on both sides to reveive glass on one side and to recive gauze on other side including iron guard bars hinges, steel peg stay, complete including taking down the existing ventilators complete all as specified 10 SQM
21 21 M&L for preparation of new steel surface of any description over 10 cm width and girth and applying 2 coats of synthetic enamel paint complete all as specified 100 SQM
22 22 M&L for applying three coats of white wash on new plastered wall surfaces including preparation of new surfaces complete all as specified 300 SQM
23 23 M&L for three coats of white wash to newly plastered ceiling surfaces including preparation of new surfaces complete all as specified 125 SQM
24 24 M&L for preparation of old surfaces of ceiling and applying one coat of white wash complete all as specified and directed 200 SQM
25 25 M&L for preparation of old surfaces of wall and applying one coat of white wash complete all as specified and directed 350 SQM
26 26 M&L for 2 coats of cement base paint over a coat of primer including preparation of newly plastered surface on walls complete all as specified 260 SQM
27 27 M&L Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube, supplying and fixing in opening as per manufacturers instructions all as directed complete all as specified 130 RM
28 28 S&F Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing complete all as specified 35 SQM
29 29 S&F 100 mm long butt hinges extruded aluminium alloy with MS hinge pin anodised and fixed type complete all as specified 81 EACH
30 30 S/F 150mm size aluminium anodised handles, fabricated type complete all as specified 54 EACH
31 31 S/F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified 54 EACH
32 32 M&L Concrete bed to drain pipes of 150mm bore in PCC 1:3:6 type C2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified. 80 RM
33 33 M&L for SGSW (salt glazed stone ware) drain / soil waste pipe 150 mm dia laid in trenches and jointed as specified 80 RM
34 34 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified 33 CUM
35 35 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified 60 CUM
36 36 S & F vitreous china squatting pan, 'orissa' pattern of size 580x440mm white, with integral foot rests including concrete bedding and connection to flush pipe complete all as specified 9 EACH
37 37 S&F PVC low level flushing cistern 10 litres capacity white with inlet ball valve, float and handle including brackets complete all as specified 8 EACH
38 38 S&F vitreous china wash basin angle back of size 400 x 400 mm white , excluding taps waste pipe but including brackets complete all as specified 8 EACH
39 39 S&F PVC connection pipe 15mm bore 450mm long complete all as specified 16 EACH
40 40 S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed 16 EACH
41 41 S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified 8 EACH
42 42 S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and laid in treanches and under floors etc complete all as specified 30 RM
43 43 S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and laid in trenches and under floor etc complete all as specified 20 RM
44 44 S&F 110mm PVC (SWR) bends any radius complete all as specified 8 EACH
45 45 S&F 75 mm PVC (SWR) bends any radius complete all as specified 8 EACH
46 46 S&F 110mm PVC (SWR) bends any radius but with access doors complete all as specified 8 EACH
47 47 S&F 75 mm PVC (SWR) bends any radius but with access doors complete all as specified 8 EACH
48 48 Taking up or down steel tubing & connections, 15 mm dia complete all as specified 20 RM
49 49 Taking up or down steel tubing & connections, 20 mm dia complete all as specified 20 RM
50 50 S & F 15mm dia. steel water tubing 'medium grade' galvanised, with all fittings & fixed complete to walls & ceilings or laid in floors complete all as specified 75 RM
51 51 S & F 20mm dia. steel water tubing 'medium grade' galvanised, with all fittings & fixed complete to walls & ceilings or laid in floors complete all as specified 60 RM
52 52 S&F 500 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Dismantling of existing water tanks complete all as specified 8 EACH
53 53 S&F 20 Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified 8 EACH
54 54 S&F PTMT Nipple suitable for HDPE water tanks (Min weight 20 mm - 45 gms) 8 EACH
55 55 S&F PTMT Bib taps fancy type of any colour screwed for iron pipe and fixed . Min weight - 15 mm - 90gms) complete all as specified 24 EACH
56 56 S&F PTMT Pillar taps fancy type of any colour screwed for iron pipe and fixed . Min weight - 15 mm - 110gms) complete all as specified 8 EACH
57 57 S&F PTMT stop valves fancy type of any colour screwed for iron pipe and fixed . Min weight - 15 mm - 90 gms) complete all as specified 8 EACH
58 58 S&F PTMT angle valves fancy type of any colour screwed for iron pipe and fixed . Min weight - 15 mm - 90 gms) complete all as specified 8 EACH
59 59 S&F swivel shower of PTMT any colour for fixing with 15 mm pipe complete ( Minimum weight 40 gms) 8 EACH
60 60 S&F looking mirror of size 450x600 with aluminium frame mounted on 6mm ply confirming to IS, with 2 Nos of hanging hooks fixed in repairs complete all as specified 8 EACH
61 61 S&F Towel rail 600 mm long of PTMT solid fixed with and including chromium plated brass screws and wooden/ plastic cleats (Min weight 190 gms) 8 EACH
62 62 S&F Harrison rails/ curtain rods of anodised aluminium alloy with fixing brackets and knobs etc complete all as specfied 35 RM
63 63 S&F in for low density polythelyne pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB etc. 32mm bore complete all as specified 8 EACH
64 64 S&F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified 8 EACH
65 65 S&F Grating round 140 mm size of PTMT. (Minimum weight 50gms) complete all as specified 8 EACH
66 66 S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified 5 SQM
67 67 S&F Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified 8 SQM
68 68 Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified 8 SQM
69 69 M&L for Machine cut kota stone slab 20-25 mm thick fixed as in Cupboard and shelves laid and jointed with greay cement mixed with pigment complete all as specified 9 SQM
70 70 M&L cement concrete 75 mm thick type C-2 (using 20 mm graded stone aggregate)as in Plinth Protection / Path etc finished even and smooth without using extra cement complete all as specified 20 SQM
71 71 M&L for Precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs set in cement mortar 1:6. 0.1 CUM
72 72 Sub main wiring complete with two runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia PVC casing capping and accessories complete all as specified and as directed. 12 RM
73 72.01 Note : 2 runs of 4 Sqmm cable and one runs of 4 Sqmm copper wire cable shall be considered one unit i.e RM .
74 73 M&L for lamp holder PVC polycarbonate type with back plate suitable for batten fitting 8 EACH
75 74 S&F LED retrofit lamp B-22 holder base with polycarbonate diffuser and aluminium heat sink of capacity 15W minimum lumens 900, suitable for 180 volt to 240 volt.\n Make : Orient/philips/C&S/Havells 8 EACH
76 75 Supply and fixing for LED tube light fittings 1x22Watts, single side connection 230 volts surface and wall mounted LED type, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm all as specified. Make : HAVELLS cat No. ENDURA LINE ARNEOBS22WLED865SPCWH/Orient/philips/C&S 8 EACH
77 76 S&F wall mounting fans , single phase, 240 volts, of 400 mm sweep 8 EACH
78 77 Supply and fixing sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 4 ways SPN complete all as directed by Engineer-in-Charge. 8 EACH
79 78 Supply and fixing MCB, 2 pole 240 volts, 32 Amps capacity complete all as specified and directed by Engineer-in-Charge. 8 EACH
80 79 Supply and fixing MCB, single pole 240 volts capacity 5 Amps to 32 Amps current rating, 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge. 24 EACH
81 80 S&F ductable airconditioner of capacity 8.5 TR complete with all necessary duct system and connecting accessories of model no DSA1021R1 of Blue star or equivalent of daikin / LG/Carrier . It includes (A) Standard installation charges of ductable Ac. (i) Installation of 8.5 TR AC ductable AC (ii) Approx copper piping for ducteble AC. (iii) Electric cable (IDU to ODU ductable AC. (iv) PVC drain pipe . (B) MS standard for out door unit. (i) MS Patla type stand for out door units ductable AC (ii) Ducta fabrication (iii) Thermal insulation (iv) Accoustic Insulation (v) canvass connection for ductable AC . (vi) Testing & commisioning along with topping up refrigerant .(C) Loading unloding tranporation charge for ductable units (D) Civil work- wall zari work (without filling) (E) Civil work- RCC Zari work (without filling) (F) Civil work - wall hole work without filling (G) Civil work- RCC core cutting (without filling) 4 EACH
82 81 2. M&L for sub main wiring complete with PVC insulated FRLS cable of single core 06 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting with accessories incl 6 Sqmm unsheathed multi standard FRLS copper conductor as earth wire.\nNote: Two runs of cable and one run of conduit & earth wire shall be measured as one run length. 100 RM
83 82 3. M&L for sub main wiring complete with PVC insulated FRLS cable of single core (4x10 Sqmm )1100 volts grade with multi standard copper conductor for drawn through and including conduiting / PVC casing capping with accessories incl 6x2 Sqmm unsheathed multi standard FRLS copper conductor as earth wire. \nNote: Four runs of cable and one run of conduit & earth wire shall be measured as one run length. 30 RM
84 83 Supply & fix sheet metal enclosure double door TPN 04 way , 415 volt. 1 EACH
85 84 Supply & fix MCB TPN 32 A, 10 KA, C Series. 5 EACH
86 85 Supply, installation, testing and commissining of isolation transformer of capacity 30 KVA, indoor type floor mounted, copper wound 3 phase 50Hz Air cooled primary voltage 415V AC and secondary voltage 415V AC at no load line to line including all necessary connected items,and all as directed by Engr-In-Charge. 1 EACH
87 86 Supply, laying, testing & commissioning cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electrical power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3½ core complete all as specified and directed. 40 RM
88 87 M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below Ground level with top edge of the plate not less than 1.5 mtr below normal GI earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt earth lead GI earth strips 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and other end of the earth strip connected to test point and protected by GI steel pipe light grade 40mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt-I of 2009 completed allas specified and directed by Engineer-in-Charge. 1 EACH
89 88 Supply and fix Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. 35 RM
90 89 Excavating in trenches not exceeding1.5m wide and not exceeding 1.5m in depth for foundation or for shafts, laying of pipelines, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed. 47 CUM
91 90 Supply and laying clean dry sand for cable cushioning including gently punning down all as directed. 14.17 CUM
92 91 M & L for burnt brick old size, 230x115x75mm size, sub class 'B' laid in trenches abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complte all as specified and as directed. 1514 EACH
93 92 Supply and laying LT XLPE insulated (ISI Marked), armoured heavy duty electric cable with aluminium conductor, 1100 volts grade 10 sqmm 2 core in trench/duct/on pole/wall etc. complete all as specified and directed.\nNote:- Excavation/earth work, sand cushioning/brick protection shall be measured and paid separately. 200 RM
94 93 S&F square shape integral decorative LED bollard with opal acrylic with IP 65 protection suitable for lamp type BGBOS 600 9W LED \nMake:- Bajaj / Philips/Havells/CG/ Syska/ Orient 2 EACH
95 94 S&F LED post top made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP 65 protection with 70W LED and inbuilt driver.\nMake: Bajaj / Havells/ Philips/ CG/ Syska/Orient 2 EACH
96 95 S&F SPN DB two way, 240 Volt, 50 Hz, single door type without busbar as directed. 2 EACH
97 96 Supply only MCB SPN 5 to 32 A, 10 KA, C Series. 2 EACH
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail