| 1 | 1 | SCHEDULE \"A\" Part - I (BUILDING WORKS)\nDetails of prepriced schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 2 | 2 | SCHEDULE \"A\" PART-II ( EARTH WORK AND SITE CLEARENCE) \nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 3 | 3 | SCHEDULE \"A\" PART-III (INTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 4 | 4 | SCHEDULE \"A\" PART-IV (INTERNAL ELECTRIFICATION)\n Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 5 | 5 | SCHEDULE \"A\" PART-V (ROAD/PATH/CULVERT)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 6 | 6 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 7 | 7 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 8 | 8 | SCHEDULE \"A\" PART-VIII (EXTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 9 | 9 | SCHEDULE \"A\" PART-IX (EXTERNAL ELECTRIFICATION)\n Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 10 | 10 | SCHEDULE \"A\" PART-X (REFRIGERATION AND AIR CONDITION)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 11 | 11 | SCHEDULE \"A\" PART -XI (MISCELLANIOUS ITEMS) Note:- \nThis schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.' E ' signifies this fact only. | | | |
|---|
| 12 | 11.01 | INTERNAL WATER SUPPLY\nS&F Sink cock with swinging casted round shape spout 15 mm dia complete all as specified. | | 2 | Each |
|---|
| 13 | 11.02 | S & F Two way bib tap 15 mm complete all as specified. Make – Drizzel or Prayag or equivalent | | 14 | Each |
|---|
| 14 | 11.03 | SUPPLY AND FIXING ANGLE COCK, 15MM FANCY TYPE,\nCHROMIUM PLATED, SCREWED DOWN, HIGH\nPRESSURE, WITH SCREWED BOTH ENDS\nFOR IRON PIPE OR FOR UNIONS AND FIXED\nCOMPLETE ALL AS SPECIFIED AND AS DIRECTED.\nMAKE : PRAYAG (CAT PAT NO-8510) OR I\nEQUIVALENT AS APPROVED BY GE. | | 49 | Each |
|---|
| 15 | 11.04 | SUPPLY AND FIXING 15MM DIA BIB TAPS LONG BODY\nWITH FLANGE CHROMIUM PLATED CAST\nCOPPER ALLOY WITH COMPLETE ALL AS\nSPECIFIED AND DIRECTED.\nMAKE : PRAYAG (CAT PAT NO-8608) OR EQUIVALENT\n AS APPROVED BY GE. | | 6 | Each |
|---|
| 16 | 11.05 | SUPPLY AND FIXING 7\" OVER HEAD SHOWER WITH\n225MM WITH FLANGE COMPLETE ALL AS SPECIFIED.\nMAKE : PRAYAG (CAT PAT NO BS-78) OR EQUIVALENT\n AS APPROVED BY GE. | | 6 | Each |
|---|
| 17 | 11.06 | SUPPLY ONLY STOP VALVE (CONCEALED TYPE)\n15 MM BORE CAST COPPER ALLOY FANCY TYPE,\nCHROMIUM PLATED WITH LONG SHANK AND CUP,\nHIGH PRESSURE, WITH SCREWED BOTH ENDS FOR\nIRON PIPE OR FOR UNIONS\nMAKE : PRAYAG (CAT PAT NO-8518) OR EQUIVALENT\n AS APPROVED BY GE. | | 6 | Each |
|---|
| 18 | 11.07 | INTERNAL ELECTRIC SUPPLY\nS & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed.\nMake: Legrand Arteor Cat-Part No. 5734 43 or equivalent model of ABB (snieo) / L&T (Entice) / Wipro | | 2 | Each |
|---|
| 19 | 11.08 | S & F modular type 1 module TV socket complete all as specified and directed. \nMake: Legrand Arteor Cat-Part No. 5734 25 or equivalent model of ABB / Hager / Wipro / L&T | | 1 | Each |
|---|
| 20 | 11.09 | S&F DB VTPN, 4Way, Double Door, IP43 protection with connected accessories like insulated bus bars, insulated IP2X neutral bars and earth Bars, blanking plates, cable management kit, incoming as MCCB and outgoing SP/TP MCB all as specified and directed. | | 1 | Each |
|---|
| 21 | 11.1 | S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.\nMake: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent model of Havells, Philips or Wipro | | 138 | Each |
|---|
| 22 | 11.11 | S&F 10W surface/ wall mounted LED batten light having high efficiency long light LED chips with luminious efficiency of >100lumen/W, Independent isolated SMPS based constant current electronic LED driver with TSD<20%, Surge voltage protection and other safety test as per IS:15885(part 2/ sec 13:2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220V-240VC, input Frequency 50-60Hz, PF>0.945, including electrical connection with 2 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make:Bajaj cat part No: 112785 BCLAB 20W or Equivalent model of Phillips/Havells/ Wipro | | 35 | Each |
|---|
| 23 | 11.12 | S&F LED street light 25W, lumen output not less than 2500 lumens high pressure die cast aluminium housing 140/270V, 50Hz, PF>0.90, including 1.2Mtr long 40/50mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of FI 40mmX6mm with bolts,nuts,washers and conductors to fitting with 3 core 1sqmm PVC insulated copper cable from control box to fitting complete all as specified.NOTE:The quoted unit rate deemed include for painting to clamps with one coat of red oxide paint before fixing. Complete all as specified and directed by Engineer-in-Charge.Make:-Wipro Cat No: LR02-291-xxx-57xx/GE Cat No: PALM-MIN or equivalent in Phillips | | 12 | Each |
|---|
| 24 | 11.13 | S & F BEE five star rated energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. \nMake: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent model of Usha or BAJAJ. | | 34 | Each |
|---|
| 25 | 11.14 | S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery upto1600CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. \nMake: Crompton Cat-Part No. TRANS AIR 12\" or equivalent model of Usha, Havells or BAJAJ | | 2 | Each |
|---|
| 26 | 11.15 | S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery upto 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. \nMake: Crompton Cat-Part No. VENTILUS 10\" or equivalent model of Usha, Havells or BAJAJ | | 14 | Each |
|---|
| 27 | 11.16 | S & F single phase static energy meter of accuracy class 1.0, 240 V , 50 Hz with backlite LCD Optical ports & RS 232 port display of rating 10-60 A with DLMS compliance as per IS 15959 ( Measures Kwh, KVAh, V, I, PF, Frequency< KW, KVA, Six month history of Energy & MD in KW & KVA and anti temper features and load profile complete as specified and directed.\nMake:Schneider/HPL/ L&T/ Secure | | 2 | Each |
|---|
| 28 | 11.17 | S & F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. \nMake: Schneider, Legrand, Havells | | | |
|---|
| 29 | 11.18 | 6 A, SP MCB, C- curve | | 41 | Each |
|---|
| 30 | 11.19 | 16 A, SP MCB, C- curve | | 16 | Each |
|---|
| 31 | 11.2 | 63 A, FP MCB, C- curve | | 1 | Each |
|---|
| 32 | 11.21 | 20 A, DP MCB, C- curve | | 4 | Each |
|---|
| 33 | 11.22 | 32 A, DP MCB, C- curve | | 1 | Each |
|---|
| 34 | 11.23 | 32 A, SPN MCB, C- curve | | 2 | Each |
|---|
| 35 | 11.24 | 20 A, SPN MCB, C- curve | | 12 | Each |
|---|
| 36 | 11.25 | 80 A, TP MCB, C- curve | | 1 | Each |
|---|
| 37 | 11.26 | S & F MCCB of 100 A, 25 kA, 04 pole all as specified and directed. | | 1 | Each |
|---|
| 38 | 11.27 | M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel wire of diameter 4.0 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 15 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed. | | 3 | Each |
|---|
| 39 | 11.28 | EXTERNAL ELECTRIFICATION\nSupply and lay double corrugated (DWC) High density polythene pipes having corrugation on the outer wall and plain surface on the inner wall, size 63mm outer dia for protection of UG Cable, with all fittings, laid in trenches/roads/ drain or fixed along wall/poles or laid under PCC interlocking tiles including road cutting and making good, complete all as specified and directed.\nMAKE: REX/POLY/ Gemini or equivalent. | | 140 | Rm |
|---|
| 40 | 11.29 | REFRIGERATION AND AIR CONDITIONING\nSupply and fix voltage stabilizing for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140V to 280V, with output voltage stabilized at 230 Volt with accuracy of +/- 2.5% and of capacity 1.0 KVA.\nMake: V-Guard/Volina/AE/ Aplab.\n | | 2 | Each |
|---|