Irrigation And Flood Control Department-IFCD has published Comprehensive Annual Maintenance Contract ( Amc ) For Electrical Gadgets ( Transformer , Stabilizer And Allied Equipments ) Installed At Various Irrigation Cum Dewatering Scheme Fall Under The Mechanical Irrigation Division Shadipora For The Year 202. Submission Date for this Tender is 30-05-2020. Transformer Supply Tenders in s Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-May-2020 | Extension of Closing Date | Date | 30-05-2020 |
Name of Work: Comprehensive Annual Maintenance Contract (AMC) for Electrical Gadgets (Transformer, Stabilizer and allied equipments) installed at various Irrigation Cum Dewatering scheme fall under the Mechanical Irrigation Division Shadipora for the year 2020-21 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: | |||
2 | 2 | Private car, auto-rickshaw or similar with 1.0 km lead | 1 | trip | |
3 | 3 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
4 | 4 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
5 | 5 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
6 | 6 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
7 | 7 | Load carrier auto, mini van or similar with 1.0 km lead | 1 | trip | |
8 | 8 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
9 | 9 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
10 | 10 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
11 | 11 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
12 | 12 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead | 1 | trip | |
13 | 13 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
14 | 14 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
15 | 15 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
16 | 16 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
17 | 17 | Truck, tipper or similar with 1.0 km lead | 1 | trip | |
18 | 18 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
19 | 19 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
20 | 20 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
21 | 21 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
22 | 22 | Disconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, taking out the rotor from the stator, and complete disassembly as per requirement of job: | |||
23 | 23 | upto 10 HP | 1 | job | |
24 | 24 | >10HP upto 60 HP | 1 | job | |
25 | 25 | >60 upto 200 HP | 1 | job | |
26 | 26 | >200 HP upto 350 HP | 1 | job | |
27 | 27 | greater than 350 HP | 1 | job | |
28 | 28 | Assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load. | |||
29 | 29 | upto 10 HP | 1 | job | |
30 | 30 | >10HP upto 60 HP | 1 | job | |
31 | 31 | >60 upto 200 HP | 1 | job | |
32 | 32 | >200 HP upto 350 HP | 1 | job | |
33 | 33 | greater than 350 HP | 1 | job | |
34 | 34 | Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. | |||
35 | 35 | upto 50 kVA | 1 | job | |
36 | 36 | >50 upto 100kVA | 1 | job | |
37 | 37 | >100kVA upto 250 kVA | 1 | job | |
38 | 38 | greater than 250 kVA | 1 | job | |
39 | 39 | Dismantling of 33/0.4 kv or 11/0.4kV transformer by way of disconnecting of all HT and LT connections, opening of top lid, draining out of T. Oil and its safe placement for further refilling, taking out of coils after removal of core assembly, etc. Job also includes detaching of core HV/LV coils. | |||
40 | 40 | upto 50 kVA | 1 | job | |
41 | 41 | >50 upto 100kVA | 1 | job | |
42 | 42 | >100kVA upto 250 kVA | 1 | job | |
43 | 43 | greater than 250 kVA upto 630kVA | 1 | job | |
44 | 44 | Complete assembling of 33/0.4 kv or 11/0.4kV transformer after cleaning of tank, fitting of coil assembly in the tank. Job further includes closing of the transformer lid by way of fitting of existing nuts/bolts and gaskets, insulators, etc. Refilling of t.oil upto required level in tank. Reconnecting of HT/ LT connections and testing. | |||
45 | 45 | upto 50 kVA | 1 | job | |
46 | 46 | >50 upto 100kVA | 1 | job | |
47 | 47 | >100kVA upto 250 kVA | 1 | job | |
48 | 48 | greater than 250 kVA upto 630kVA | 1 | job | |
49 | 49 | Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil | |||
50 | 50 | upto 50 kVA | 1 | job | |
51 | 51 | >50 upto 100kVA | 1 | job | |
52 | 52 | >100kVA upto 250 kVA | 1 | job | |
53 | 53 | greater than 250 kVA | 1 | job | |
54 | 54 | Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. | |||
55 | 55 | >60 upto 200 HP | 1 | job | |
56 | 56 | >200 HP upto 350 HP | 1 | job | |
57 | 57 | greater than 350 HP | 1 | job | |
58 | 58 | Fitting of autotransformer coil assembly in the starter oil tank, refilling of collected t.oil in the tank, reconnecting all leads and load testing of the starter. | |||
59 | 59 | >60 upto 200 HP | 1 | job | |
60 | 60 | >200 HP upto 350 HP | 1 | job | |
61 | 61 | greater than 350 HP | 1 | job | |
62 | 62 | Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) | 1 | ltr | |
63 | 63 | Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)\n(Process loss maximum of 5% allowed) | 1 | ltr | |
64 | 64 | Complete rewinding of stator coils of 3-phase LV horizontal/ vertical induction motor with suitable copper wire after complete removal of burnt out winding, cleaning of slots, etc., insulation class F, varnishing, tapping, etc. excluding carriage and dismantling/ reassembling charges.\n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). | |||
65 | 65 | 5 HP 4-pole | 1 | job | |
66 | 66 | 20 HP 4-pole | 1 | job | |
67 | 67 | 25 HP 4-pole | 1 | job | |
68 | 68 | 30 HP 4-pole | 1 | job | |
69 | 69 | 40 HP 4-pole | 1 | job | |
70 | 70 | 50 HP 4-pole | 1 | job | |
71 | 71 | 50 HP 6-pole | 1 | job | |
72 | 72 | 60 HP 4-pole | 1 | job | |
73 | 73 | 60 HP 6-pole | 1 | job | |
74 | 74 | 75 HP 4-pole | 1 | job | |
75 | 75 | 100 HP 4-pole | 1 | job | |
76 | 76 | 100 HP 6-pole | 1 | job | |
77 | 77 | 120 HP 4-pole | 1 | job | |
78 | 78 | 125 HP 8-pole | 1 | job | |
79 | 79 | Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. | |||
80 | 80 | upto 5HP | 1 | job | |
81 | 81 | > 5 HP upto 20 HP | 1 | job | |
82 | 82 | > 20 HP upto 50 HP | 1 | job | |
83 | 83 | > 50 HP upto 100 HP | 1 | job | |
84 | 84 | > 100 HP upto 200 HP | 1 | job | |
85 | 85 | > 200 HP upto 350 HP | 1 | job | |
86 | 86 | > 350 HP | 1 | job | |
87 | 87 | Providing and fitting of brake lining for AC solenoid brake having nominal wheel diameter as under: | |||
88 | 88 | 4 inch | 1 | job | |
89 | 89 | 5.5 inch | 1 | job | |
90 | 90 | 7 inch | 1 | job | |
91 | 91 | 10 inch | 1 | job | |
92 | 92 | Providing and fitting of brake shoe assembly for AC solenoid brake having nominal wheel diameter as under: | |||
93 | 93 | 4 inch | 1 | job | |
94 | 94 | 5.5 inch | 1 | job | |
95 | 95 | 7 inch | 1 | job | |
96 | 96 | 10 inch | 1 | job | |
97 | 97 | Providing and fitting of brake coil for AC solenoid brake having nominal wheel diameter as under: | |||
98 | 98 | 4 inch | 1 | job | |
99 | 99 | 5.5 inch | 1 | job | |
100 | 100 | 7 inch | 1 | job | |
101 | 101 | 10 inch | 1 | job | |
102 | 102 | Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation.\n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). | |||
103 | 103 | 10kVA rating | 1 | limb | |
104 | 104 | 25kVA rating | 1 | limb | |
105 | 105 | 50kVA rating | 1 | limb | |
106 | 106 | 75kVA rating | 1 | limb | |
107 | 107 | 100kVA rating | 1 | limb | |
108 | 108 | 150kVA rating | 1 | limb | |
109 | 109 | 175kVA rating | 1 | limb | |
110 | 110 | 200kVA rating | 1 | limb | |
111 | 111 | 250kVA rating | 1 | limb | |
112 | 112 | 500kVA rating | 1 | limb | |
113 | 113 | 600kVA rating | 1 | limb | |
114 | 114 | Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality Almunium wire of proper gauge as per requirement with superior insulation.\n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). | |||
115 | 115 | 10kVA rating | 1 | limb | |
116 | 116 | 25kVA rating | 1 | limb | |
117 | 117 | 50kVA rating | 1 | limb | |
118 | 118 | 75kVA rating | 1 | limb | |
119 | 119 | 100kVA rating | 1 | limb | |
120 | 120 | 150kVA rating | 1 | limb | |
121 | 121 | 175kVA rating | 1 | limb | |
122 | 122 | 200kVA rating | 1 | limb | |
123 | 123 | 250kVA rating | 1 | limb | |
124 | 124 | 500kVA rating | 1 | limb | |
125 | 125 | Providing and replacement of copper contact points on regulator plate | 1 | kg | |
126 | 126 | Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) | 1 | kg | |
127 | 127 | Rewinding burnt/ damaged limb/s of autotransformer coil assembly (comprising of three limbs) of below specified rating using superior quality copper wire of proper gauge as per requirement with superior insulation, varnish, etc. \n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates). | |||
128 | 128 | 125 HP | 1 | limb | |
129 | 129 | 275 HP | 1 | limb | |
130 | 130 | 300 HP | 1 | limb | |
131 | 131 | 375 HP | 1 | limb | |
132 | 132 | 400 HP | 1 | limb | |
133 | 133 | 425 HP | 1 | limb | |
134 | 134 | Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: | |||
135 | 135 | L&T ML 2 | 1 | no. | |
136 | 136 | L&T ML 4 | 1 | no. | |
137 | 137 | L&T ML 10 | 1 | no. | |
138 | 138 | L&T MNX 50 | 1 | no. | |
139 | 139 | L&T MNX 70 | 1 | no. | |
140 | 140 | L&T MNX 80 | 1 | no. | |
141 | 141 | L&T MNX 95 | 1 | no. | |
142 | 142 | L&T MNX 110 | 1 | no. | |
143 | 143 | L&T MNX 225 | 1 | no. | |
144 | 144 | L&T MNX 250 | 1 | no. | |
145 | 145 | Schneider Electric LC1F265 (without coil) | 1 | no. | |
146 | 146 | Schneider Electric LC1F330 (without coil) | 1 | no. | |
147 | 147 | Schneider Electric LC1F400 (without coil) | 1 | no. | |
148 | 148 | Schneider Electric LC1F630 (without coil) | 1 | no. | |
149 | 149 | 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) | 1 | no. | |
150 | 150 | 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) | 1 | no. | |
151 | 151 | Providing and fitting of new coil with specified coil voltage for contactors as under: | |||
152 | 152 | 9A to 45A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) | 1 | no. | |
153 | 153 | L&T ML 2/ 3 | 1 | no. | |
154 | 154 | L&T ML 4/ 6 | 1 | no. | |
155 | 155 | L&T ML 10/ 12 | 1 | no. | |
156 | 156 | L&T MNX 50/ 70/ 80 | 1 | no. | |
157 | 157 | L&T MNX 95/ 110/ 140 | 1 | no. | |
158 | 158 | L&T MNX 185/ 225/ 250 | 1 | no. | |
159 | 159 | L&T MNX 300/ 400 | 1 | no. | |
160 | 160 | L&T MNX 550/ 650 | 1 | no. | |
161 | 161 | Schneider Electric LC1F185/ LC1F225 | 1 | no. | |
162 | 162 | Schneider Electric LC1F265/ LC1F330 | 1 | no. | |
163 | 163 | Schneider Electric LC1F400 | 1 | no. | |
164 | 164 | Schneider Electric LC1F630 | 1 | no. | |
165 | 165 | Providing and fitting of new Contact kit set for contactors | |||
166 | 166 | 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) | 1 | set | |
167 | 167 | L&T ML 2 | 1 | set | |
168 | 168 | L&T ML 3 | 1 | set | |
169 | 169 | L&T ML 4 | 1 | set | |
170 | 170 | L&T ML 6 | 1 | set | |
171 | 171 | L&T ML 10 | 1 | set | |
172 | 172 | L&T ML 12 | 1 | set | |
173 | 173 | Providing and fitting of auxillary/ control relay (L&T MX0 or similar) for AC control | 1 | no. | |
174 | 174 | Providing and fitting of auxillary/ control relay (L&T MN0 or similar) for DC control | 1 | no. | |
175 | 175 | Providing and fitting of (1NO+1NC) side mounting auxillary contact block (For L&T/ Schneider Electric make contactors). | 1 | no. | |
176 | 176 | Providing and fitting of front mounting auxillary contact block having 04 contacts (all combinations) (For L&T/ Schneider Electric/ Siemens make contactors) | 1 | no. | |
177 | 177 | Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . | |||
178 | 178 | (2NO + 2NC) double block; ON delay | 1 | no. | |
179 | 179 | (2NO + 2NC) double block; ON & OFF delay | 1 | no. | |
180 | 180 | Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) | |||
181 | 181 | (2NO + 2NC) contact block | 1 | no. | |
182 | 182 | Magnetic coil 415V AC | 1 | no. | |
183 | 183 | Magnet frame assembly without coil | 1 | no. | |
184 | 184 | Providing, fitting and setting of DIN mounted electronic Timer (L&T or equivalent make) | |||
185 | 185 | Star Delta (range from 3s - 120s) 240V AC | 1 | no. | |
186 | 186 | Star Delta (range from 3s - 30s) 240 - 415V AC | 1 | no. | |
187 | 187 | ON delay (0.3s - 30hrs) 240V AC | 1 | no. | |
188 | 188 | Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) | 1 | no. | |
189 | 189 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T MN2) | |||
190 | 190 | Relay range in between 0.2A to 15A | 1 | no. | |
191 | 191 | 14-23A | 1 | no. | |
192 | 192 | 20-33A | 1 | no. | |
193 | 193 | 24-40A | 1 | no. | |
194 | 194 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T MN5) | |||
195 | 195 | 30-50A | 1 | no. | |
196 | 196 | 36-60A | 1 | no. | |
197 | 197 | 45-75A | 1 | no. | |
198 | 198 | 66-110A | 1 | no. | |
199 | 199 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T ML2/3) | |||
200 | 200 | Relay ranges in between 9A to 42A | 1 | no. | |
201 | 201 | Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots | 1 | sft | |
202 | 202 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. | 1 | job | |
203 | 203 | Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. | 1 | job | |
204 | 204 | Providing and fitting of Jaw contact for ACB (L&T C-power) | |||
205 | 205 | Providing new CRGO lamination to the core in place of damaged core wherever necessary including cost of materials and labour | 1 | kg | |
206 | 206 | Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. | 1 | kg | |
207 | 207 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. | 1 | kg | |
208 | 208 | Providing and fitting of finished new aluminium strip windings with insulation in place of damaged windings including labour costs, etc., (Both HV & LV) - per kg of winding. | 1 | kg | |
209 | 209 | providing, fitting Rewinding with re-insulation of new copper/ aluminium conductors (HV/ LV) by way of providing and replacement of inter-layer insulation - per kg of winding. | 1 | kg | |
210 | 210 | Rewinding without re-insulation of existing / aluminium conductors ( LT) - per kg of winding. | 1 | kg | |
211 | 211 | Providing and fitting of Hot dipped galvanised MS nuts, bolts and washers of assorted sizes | 1 | kg | |
212 | 212 | Providing and fitting of 6mm thick neoprene rubber gasket | 1 | no. | |
213 | 213 | 1600A/ 2000A | 1 | no. | |
214 | 214 | Providing and fitting of Fixed arcing contact for ACB (L&T C-power) | |||
215 | 215 | 800- 1600A | 1 | set of 03 | |
216 | 216 | 2000A | 1 | set of 03 | |
217 | 217 | Providing and fitting of Moving arcing contact for ACB (L&T C-power) | |||
218 | 218 | 800- 2000A | 1 | set of 09 | |
219 | 219 | Providing and fitting of Shunt release for ACB (L&T C-power) | 1 | no. | |
220 | 220 | Providing and fitting of Under Voltage Release for ACB (L&T C-power) | 1 | no. | |
221 | 221 | Providing and fitting of Earth Fault Release for ACB (L&T C-power) | 1 | no. | |
222 | 222 | Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: | |||
223 | 223 | upto 800 - 1250A | 1 | no. | |
224 | 224 | 1600 - 2000A | 1 | no. | |
225 | 225 | Providing and fitting of CT for DN1 type L&T C-power ACB | |||
226 | 226 | 800/ 1000A | 1 | no. | |
227 | 227 | 2000A | 1 | no. | |
228 | 228 | Providing and fitting of main spring for 3-pole ACB (L&T C-power) | |||
229 | 229 | 800- 1600A | 1 | no. | |
230 | 230 | 2000A | 1 | no. | |
231 | 231 | Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) | 1 | no. | |
232 | 232 | Providing and fitting of flush type analog moving iron AC meter as under:\n(Make: Rishabh/ AE/ C&S/ BCH) | |||
233 | 233 | 48x48mm 500V voltmeter | 1 | no. | |
234 | 234 | 96x96mm 500V voltmeter | 1 | no. | |
235 | 235 | 144x144mm 500V voltmeter | 1 | no. | |
236 | 236 | 96x96mm ammeter (5A CT operated) | 1 | no. | |
237 | 237 | Volt-Ammeter 500V, current ranges upto 125A (AE/ Rishabh/ L&T) | 1 | no. | |
238 | 238 | Providing and fitting of flush type frequency meter with range 45-55Hz:\n(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) | 1 | no. | |
239 | 239 | Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) | 1 | no. | |
240 | 240 | Providing and fitting of 10A voltmeter selector switch with OFF\n(Make: L&T/ Rishabh/ AE/ Teknic) | 1 | no. | |
241 | 241 | Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: | |||
242 | 242 | 100/5A or 150/5A - Class 1 - Burden 5VA | 1 | no. | |
243 | 243 | 200/5A - Class 1 - Burden 10VA | 1 | no. | |
244 | 244 | 400/5A - Class 1 - Burden 15VA | 1 | no. | |
245 | 245 | 600/5A - Class 1 - Burden 15VA | 1 | no. | |
246 | 246 | 800/5A - Class 1 - Burden 15VA | 1 | no. | |
247 | 247 | 1000/5A - Class 1 - Burden 15VA | 1 | no. | |
248 | 248 | 2000/5A - Class 1 - Burden 15VA | 1 | no. | |
249 | 249 | Extra for 1A secondary upto 600/1A over corresponding rate | 1 | no. | |
250 | 250 | Providing and fitting of analog VAC hour meter\n(Make: L&T or equivalent make) | |||
251 | 251 | Flush mounting type | 1 | no. | |
252 | 252 | Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) | 1 | no. | |
253 | 253 | Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) | 1 | no. | |
254 | 254 | Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) | 1 | no. | |
255 | 255 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) | |||
256 | 256 | 50V or less unbalance & 1 C/O DIN mounted | 1 | no. | |
257 | 257 | 50V or less unbalance & 1 C/O Panel wall mounted | 1 | no. | |
258 | 258 | 70V or less unbalance & 2 C/O DIN mounted | 1 | no. | |
259 | 259 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) | 1 | no. | |
260 | 260 | Providing of HRC fuses (2A - 32A) ratings | 1 | no. | |
261 | 261 | Providing and fitting of Fuse holders for fuses upto 32A rating | 1 | no. | |
262 | 262 | Providing and fixing uPVC panel trunking with cover | |||
263 | 263 | 15x15mm | 1 | mtr | |
264 | 264 | 25x25mm | 1 | mtr | |
265 | 265 | Providing and fitting of Terminal Block 100A - 3 way | 1 | no. | |
266 | 266 | Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: | |||
267 | 267 | 16 sq. mm | 1 | no. | |
268 | 268 | 25 sq. mm | 1 | no. | |
269 | 269 | 35 sq. mm | 1 | no. | |
270 | 270 | 50 sq. mm | 1 | no. | |
271 | 271 | 70 sq. mm | 1 | no. | |
272 | 272 | 95 sq. mm | 1 | no. | |
273 | 273 | 120 sq. mm | 1 | no. | |
274 | 274 | 150 sq. mm | 1 | no. | |
275 | 275 | 185 sq. mm | 1 | no. | |
276 | 276 | 225 sq. mm | 1 | no. | |
277 | 277 | 240 sq. mm | 1 | no. | |
278 | 278 | 300 sq. mm | 1 | no. | |
279 | 279 | 400 sq. mm | 1 | no. | |
280 | 280 | 500 sq. mm | 1 | no. | |
281 | 281 | 630 sq. mm | 1 | no. | |
282 | 282 | Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: | |||
283 | 283 | 16 sq. mm | 1 | no. | |
284 | 284 | 25 sq. mm | 1 | no. | |
285 | 285 | 35 sq. mm | 1 | no. | |
286 | 286 | 50 sq. mm | 1 | no. | |
287 | 287 | 70 sq. mm | 1 | no. | |
288 | 288 | 95 sq. mm | 1 | no. | |
289 | 289 | 120 sq. mm | 1 | no. | |
290 | 290 | 150 sq. mm | 1 | no. | |
291 | 291 | 185 sq. mm | 1 | no. | |
292 | 292 | 225 sq. mm | 1 | no. | |
293 | 293 | 240 sq. mm | 1 | no. | |
294 | 294 | 300 sq. mm | 1 | no. | |
295 | 295 | 400 sq. mm | 1 | no. | |
296 | 296 | 500 sq. mm | 1 | no. | |
297 | 297 | 630 sq. mm | 1 | no. | |
298 | 298 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. | 1 | mtr | |
299 | 299 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 1 | mtr | |
300 | 300 | Providing and fitting of LT/HT Bush Rode | 1 | mtr | |
301 | 301 | 12 MM | 1 | mtr | |
302 | 302 | 16MM | 1 | mtr | |
303 | 303 | 19MM | 1 | mtr | |
304 | 304 | 35MM | 1 | mtr | |
305 | 305 | Providing and fitting of HT Bush | 1 | no. | |
306 | 306 | Providing and fitting of LT Bush cup | 1 | no. | |
307 | 307 | Providing and fitting of LT Bus Bar | 1 | no. | |
308 | 308 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess with GI saddles and allied fittings for connections etc. as required. | 1 | mtr | |
309 | 309 | Providing and fitting of condut/Baklite/Sleeves/Hard Board/Lathiride paper/Gum/HT paper for 100/250/300 Kva | 1 | job | |
310 | 310 | Credit value for scrap copper | 1 | kg |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail