Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-05-2020 | The time period of completion will be 6 Months | Other | 09-06-2020 |
| Name of Work : CONSTRUCTION OF ITI AT VILLAGE : MANAN KE, BLOCK : GANDIWIND, DISTRICT TARN TARAN (PUNJAB) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORKS (A-1) | |||
| 2 | 2 | Construction of Main Building Two storey | |||
| 3 | 3 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | 1544.03 | cum | |
| 4 | 4 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides up to height of 300mm by uniformly spraying solution @ 5 Litre / sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter (width - 300 mm, depth - 450 mm) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per sqm. | 1235.03 | ltr | |
| 5 | 5 | Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type | 158.19 | cum | |
| 6 | 6 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. | 503.93 | Cum | |
| 7 | 7 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 912.72 | sqm | |
| 8 | 8 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. | |||
| 9 | 9 | BEAMS | |||
| 10 | 10 | Ground Floor | 95.44 | Cum | |
| 11 | 11 | First Floor | 58.35 | Cum | |
| 12 | 12 | Extra rate for First Floor | 58.35 | Cum | |
| 13 | 13 | Second Floor | 2.64 | Cum | |
| 14 | 14 | Extra rate for Second Floor | 2.64 | Cum | |
| 15 | 15 | SLAB | |||
| 16 | 16 | Ground Floor | 311.62 | Cum | |
| 17 | 17 | First Floor | 198.96 | Cum | |
| 18 | 18 | Extra rate for First Floor | 198.96 | Cum | |
| 19 | 19 | Second Floor | 4.7 | Cum | |
| 20 | 20 | Extra rate for Second Floor | 4.7 | Cum | |
| 21 | 21 | DOOR LINTEL | |||
| 22 | 22 | Ground Floor | 7.93 | Cum | |
| 23 | 23 | First Floor | 4.93 | Cum | |
| 24 | 24 | Extra rate for First Floor | 4.93 | Cum | |
| 25 | 25 | Second Floor | 0.24 | Cum | |
| 26 | 26 | Extra rate for Second Floor | 0.24 | Cum | |
| 27 | 27 | COLUMNS (Rect. & Square) | |||
| 28 | 28 | Ground Floor | 88.78 | Cum | |
| 29 | 29 | First Floor | 58.68 | Cum | |
| 30 | 30 | Extra rate for First Floor | 58.68 | Cum | |
| 31 | 31 | Second Floor | 1.92 | Cum | |
| 32 | 32 | Extra rate for Second Floor | 1.92 | Cum | |
| 33 | 33 | SHELVES | |||
| 34 | 34 | Ground Floor | 3.86 | Cum | |
| 35 | 35 | First Floor | 0.14 | Cum | |
| 36 | 36 | Extra rate for First Floor | 0.14 | Cum | |
| 37 | 37 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain) | |||
| 38 | 38 | Ground Floor | 1134 | Sqm | |
| 39 | 39 | First Floor | 469.44 | Sqm | |
| 40 | 40 | Extra rate for First Floor | 469.44 | Sqm | |
| 41 | 41 | Second Floor | 15.36 | Sqm | |
| 42 | 42 | Extra rate for Second Floor | 15.36 | Sqm | |
| 43 | 43 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. | |||
| 44 | 44 | Ground Floor | 2602.72 | Sqm | |
| 45 | 45 | First Floor | 1642.58 | Sqm | |
| 46 | 46 | Extra rate for First Floor | 1642.58 | Sqm | |
| 47 | 47 | Second Floor | 38.78 | Sqm | |
| 48 | 48 | Extra rate for First Floor | 38.78 | Sqm | |
| 49 | 49 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels | |||
| 50 | 50 | Ground Floor | 826.96 | Sqm | |
| 51 | 51 | First Floor | 506.24 | Sqm | |
| 52 | 52 | Extra rate for First Floor | 506.24 | Sqm. | |
| 53 | 53 | Second Floor | 23.04 | Sqm | |
| 54 | 54 | Extra rate for Second Floor | 23.04 | Sqm. | |
| 55 | 55 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. | |||
| 56 | 56 | Ground Floor | 5.61 | Sqm | |
| 57 | 57 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. | 14.48 | sqm | |
| 58 | 58 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. | 325.64 | Cum | |
| 59 | 59 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.. | |||
| 60 | 60 | Ground Floor | 277.03 | Cum | |
| 61 | 61 | First Floor | 168.7 | Cum | |
| 62 | 62 | Extra rate for First Floor | 168.7 | Cum. | |
| 63 | 63 | Second Floor | 54.28 | Cum | |
| 64 | 64 | Extra rate for Second Floor | 54.28 | Cum. | |
| 65 | 65 | Third Floor | 2.15 | Cum | |
| 66 | 66 | Extra rate for Third Floor | 2.15 | Cum. | |
| 67 | 67 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005. | |||
| 68 | 68 | Ground Floor | 105.32 | Cum | |
| 69 | 69 | First Floor | 103.12 | Cum | |
| 70 | 70 | Extra rate for First Floor | 103.12 | Cum. | |
| 71 | 71 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. | |||
| 72 | 72 | Ground Floor | 332.09 | Sqm | |
| 73 | 73 | First Floor | 58.79 | Sqm | |
| 74 | 74 | Extra rate for First Floor | 58.79 | Sqm | |
| 75 | 75 | 12.5mm thick cement plaster 1:5. | 2423.83 | Sqm. | |
| 76 | 76 | 20 mm thick cement plaster 1:5 in two coats work. | 2423.83 | Sqm | |
| 77 | 77 | 12.5 mm thick cement plaster 1:4. | 1296.48 | Sqm. | |
| 78 | 78 | 20 mm thick cement plaster 1:4. | 1296.48 | Sqm | |
| 79 | 79 | Extra rate for Smooth Surface of Ceiling. | 2797.32 | sqm | |
| 80 | 80 | Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) | 393.02 | Rmt. | |
| 81 | 81 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. | 54 | Nos. | |
| 82 | 82 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. | 215 | Nos. | |
| 83 | 83 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. \nM.S. Holder bats clamps for 100mm i/d H.C.I. pipes | 215 | Nos. | |
| 84 | 84 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. | 54 | Nos. | |
| 85 | 85 | Providing and fixing in position gratings 150mm x 150mm for gully trap.\nPVC grating | 54 | Nos. | |
| 86 | 86 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. | 54 | Nos. | |
| 87 | 87 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement | |||
| 88 | 88 | First Floor | 823.73 | Sqm. | |
| 89 | 89 | Extra rate for First Floor | 823.73 | Sqm. | |
| 90 | 90 | Second Floor | 1190.83 | Sqm. | |
| 91 | 91 | Extra rate for Second Floor | 1190.83 | Sqm. | |
| 92 | 92 | Thrid Floor | 25.93 | Sqm. | |
| 93 | 93 | Extra rate for Third Floor | 25.93 | Sqm. | |
| 94 | 94 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. | 411.92 | Rmt | |
| 95 | 95 | Earth filling with good quality earth obtained from out side the plinth including compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compacting with rammer complete as per specifications. | 2960.48 | cum | |
| 96 | 96 | Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres | 617.61 | cum | |
| 97 | 97 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) | 2020.27 | Sqm. | |
| 98 | 98 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping (Using mechanical mixer for mixing of material). | |||
| 99 | 99 | First Floor | 819.01 | Sqm. | |
| 100 | 100 | Extra rate for First Floor | 819.01 | Sqm. | |
| 101 | 101 | Second Floor | 23.25 | Sqm. | |
| 102 | 102 | Extra rate for Second Floor | 23.25 | Sqm. | |
| 103 | 103 | Baroda green marble flooring 15mm to 20mm thick over 12.5mm thick base of Cement mortar 1:3 laid and jointed with white cement slurry with pigment to match the shade of marble including rubbing & Polishing.\nTiles Size 45 cm x 60 cm & above | |||
| 104 | 104 | Ground Floor | 132.42 | Sqm. | |
| 105 | 105 | First Floor | 16.52 | Sqm. | |
| 106 | 106 | Extra rate for First Floor | 16.52 | Sqm. | |
| 107 | 107 | Kota stone tile flooring 20mm to 30 mm thick over 12.5mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing. | |||
| 108 | 108 | Ground Floor | 524.55 | sqm | |
| 109 | 109 | First Floor | 252.57 | sqm | |
| 110 | 110 | Extra rate for First Floor | 252.57 | Sqm. | |
| 111 | 111 | Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing | |||
| 112 | 112 | Ground Floor | 28.11 | sqm | |
| 113 | 113 | First Floor | 14.9 | sqm | |
| 114 | 114 | Extra rate for First Floor | 14.9 | Sqm. | |
| 115 | 115 | Providing and fixing Morwad marble strip 18mm to 20mm thick and 100mm wide in Kotah Stone Flooring over 12.50 mm thick base of cement mortar 1:3 jointed with cement slurry including cost of aditional mortar equivallent to the kotah stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. | 850.7 | rmt | |
| 116 | 116 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with cement contents 350kg per cum and coarse and fine aggregates conforming to IS:383 mixed with concrete mixer using weigh batcher, laid in position over 125 micron thick polythene sheet, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, including provision of contraction and expansion joints as required, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications | 138.2 | Cum | |
| 117 | 117 | Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Double Charge Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base, including grouting the joints (Tiles to be laid with 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout). with cement based grout and matching pigments etc., complete (Design is homogenous throughout the tile body). \n | |||
| 118 | 118 | Ground Floor | 357.99 | Sqm. | |
| 119 | 119 | First Floor | 575.69 | Sqm. | |
| 120 | 120 | Extra rate for First Floor | 575.69 | Sqm. | |
| 121 | 121 | Coloured Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. | |||
| 122 | 122 | Ground Floor | 4.23 | Sqm. | |
| 123 | 123 | Extra labour for projected nosing of stair case of any shape and design | 144.7 | rmt | |
| 124 | 124 | Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. | |||
| 125 | 125 | Ground Floor | 138.64 | Sqm. | |
| 126 | 126 | Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. | |||
| 127 | 127 | Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter. | 290.77 | Rmt | |
| 128 | 128 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. | 294.96 | Rmt | |
| 129 | 129 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) | 1237.5 | kg | |
| 130 | 130 | Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects. | 19.16 | Sqm | |
| 131 | 131 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area. | 69.62 | Sqm | |
| 132 | 132 | Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect | 251.45 | rmt | |
| 133 | 133 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. | 37.88 | qtl | |
| 134 | 134 | Extra for providing Polyster Powder Coating 60 to 70 micron any coloured specified to M.S Grills section of various sizes including carriage of material from market to workshop | 3787.5 | Kg | |
| 135 | 135 | Supplying and fixing rolling shutters of approved make, made of 80mm x 1.25mm M.S. Laths, interlocked together through their entire length, and jointed together, at the end by end locks, mounted on specially designed pipe shaft, with brackets, side guides 27.5 cm long wire spring grade No. 2 and arrangement for inside and outside locking, with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening; where rolling shutter is to be fixed). | 46.45 | Sqm | |
| 136 | 136 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : | |||
| 137 | 137 | For fixed portion & Chaukhat | 1624.86 | kg | |
| 138 | 138 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required | 1577.4 | kg | |
| 139 | 139 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop. | 3202.26 | Kg | |
| 140 | 140 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) | |||
| 141 | 141 | With float glass panes of 5.5 mm thickness. | 234.57 | sqm | |
| 142 | 142 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineer-in-charge. | 83 | nos | |
| 143 | 143 | ACOUSTICAL SLATS FOR WALL PANELING \nSupply & installation of Slats made of pinewood E1 grade fiberboard, veneer/Melamine laminated finish, groove perforated slats L8-2 - (2mm grooves @ 8mm centers) / L16-2 - (2mm Slats@16mm pitch) / L32-2 - (2mm grooves @ 32mm centers) / L64-2 - (2mm grooves @ 64mm centers), backlined with black acoustical fleece, tongue-groove edge for a seamless look, FR grade, of size 128x2440x16mm thick having base density 800Kg/m3, weight 12Kgs/m2 installed by using GI strut system.\nThe GI strut system includes GI Cross channel (CC10) having thickness 0.45mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened horizontally at every 600mm centers. Aluminium core cross channel (CC18) having thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & centre brackets is then fixed perpendicular to the CC10 with the help of fasteners at every 400mm centers. Slats of size 128x 2440x16mm in then fixed perpendicular to CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 5mtrs bothways. Note:-Wooden packing of appropriate thickness to be used at rear of strut to bring finish inline with Subtex NRC finish.\nPanels shall be backlined with acoustical infill of Anutone Synth PF 10x25mm thick adhered to the wall using Stick 7 adhesive Complete in all respect to the entire satisfation of Engineer-in-charge./Drawing. \nTechnical Parameters\n• Core Variants - Pinewood E1 Fibreboard\n• Fire – Class 1 & P\n• Acoustics – NRC upto 0.75\n• Climate (OC RH) – 50, 70\n• Light reflectance – 75%\n• Green (RC %) – 25\n• Hygiene (VoC, Clean room) – Low, Class 1\n• Strength, Load capacity (Kg) - Ball-Impact | 256.4 | Sqm | |
| 144 | 144 | Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc.complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge. | 19.51 | Sqm | |
| 145 | 145 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,\nCommercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-\n | |||
| 146 | 146 | 35mm thick | 150.54 | Sqm | |
| 147 | 147 | Wire gauge Hollock wood door shutter without springs housed in chowkhat.\n35mm thick | 42.92 | Sqm | |
| 148 | 148 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)\nFor shutter area above 0.50 sqm | 318.13 | Sqm | |
| 149 | 149 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :\n300mm x 16mm | 64 | Nos | |
| 150 | 150 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect | 18.29 | Rmt. | |
| 151 | 151 | Providing & fixing 16 gauge stainless steel pipe of top of various size railing of grade 304 duly fixed on ramp with the help of bolts grouted on floor with hand rail and newel post of 50mm dia Stainless steel pipe , Balusters of 40mm dia Stainless steel pipe complete in all respect as per specification and entire satisfaciton of Engineer-in-Charge. (Railing on Enterance Ramp Design as per guidelines issued for persons with disability) | 44.35 | rmt | |
| 152 | 152 | Providing & fixing 16 gauge stainless steel pipe of various sizes railing of grade 304 duly fixed on side wall with the help of bolts fixed with hand rail, S.S square bar 25 x 25mm welded to S.S flat 50 x 5mm complete in all respect as per specification and entire satisfaciton of Engineer-in-Charge. (Railing along wall in Ramp for upper storey Design as per guidelines issued for persons with disability) | 100.58 | rmt | |
| 153 | 153 | Providing and fixing of false ceiling at all heights of 600x600x15mm/600*1200*15mm Mineral Fibre ceiling tiles RH-99 laid in grid system. The frame work comprise of made of GI 120 GSM coating with minimum 0.3mm thickness main runner spaced at 1200mm centre to centre securely fixed to the structural soffit by approved hangers at 1200mm maximum centres. Hangersa (GI wire of 4mm dia) to be fixed by approved roof plug, level adjusters and screw etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees (with double stiching) to be interlocked between main runners at 600mm centres to form 1200x600mm modules. Cut across tees longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trim to be wall angle secured to walls at 450mm maximum centres complete in all respects as per specifications. | 210.65 | sqm | |
| 154 | 154 | Providing and Fixing of flase Ceiling at all heights of 600x600x0.50mm / 600*1200*0.50mm Metal ceiling perforated tiles without Fleece Powder Coated of 60 to 70 microne type OREO GI Laid in grid system The frame work comprise of made of GI 120 GSM coating with minimum 0.3 mm thicness main runner spaced at 1200 mm centre ot center secruely fixed to the structural soffit by approved hangers at 1200mm maximum centres. Hangers (GI wire of 4mm dia) to be fixed by approved roof plug, level adjusters and screw etc. The last hanger at the end of each main runner should not be greater than 450mm from the ajacent wall. Flush fitting 1200mm long cross tees (with double stiching) to be interlocked between main runners at 600mm centres to form 1200x600mm modules. Cut across tees longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600 long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trim to be wall angle secured to walls at 450mm maximum centres. Wall height of Cross toe 24mmx26mmx32mm and Main Runner 24mmx38mmx32mm complete in all respects as per specifications. | 76.1 | sqm | |
| 155 | 155 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete | |||
| 156 | 156 | Foundation & Ground Floor | 1180.79 | qtl | |
| 157 | 157 | First Floor | 379.52 | qtl | |
| 158 | 158 | Extra rate for First Floor | 379.52 | qtl | |
| 159 | 159 | Second Floor | 11.78 | qtl | |
| 160 | 160 | Extra rate for Second Floor | 11.78 | qtl | |
| 161 | 161 | Extra rate for using steel produced by primary producer such as SAIL/RINL/TATA/JINDAL complete in all respect as per the directions of Engineer-in-charge. | 1572.09 | Qtl. | |
| 162 | 162 | Providing and applying plaster of paris (ISI marked) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. | 2510.57 | sqm | |
| 163 | 163 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish | 7440.62 | Sqm | |
| 164 | 164 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior sufrace | 10237.9 | Sqm | |
| 165 | 165 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats) | 7644.98 | Sqm | |
| 166 | 166 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. \nWith ordinary quality Paint | 116.13 | sqm | |
| 167 | 167 | Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work With ordinary quality Paint | 116.13 | sqm | |
| 168 | 168 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. | 338.72 | Sqm | |
| 169 | 169 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. | 548.72 | Sqm | |
| 170 | 170 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade with ordinary quality paint. | 338.72 | sqm | |
| 171 | 171 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm | 2592.96 | Sqm | |
| 172 | 172 | Providing & Fixing writing board Size 6'-00\" x 4'-00\" finished with 1 mm thick white sunmica having aluminium frame work complete as per specification & desired by Engineer-in-Charge. | 8 | Nos | |
| 173 | 173 | Construction of Plinth protection complete as per drawing. | |||
| 174 | 174 | Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. | 30.5 | Cum. | |
| 175 | 175 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. | 12.2 | Cum. | |
| 176 | 176 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. | 14.64 | Cum. | |
| 177 | 177 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) | 120.15 | Sqm. | |
| 178 | 178 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). | 144.18 | Sqm. | |
| 179 | 179 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. | 96.12 | Sqm. | |
| 180 | 180 | Total A1:- | 1 | Sqm. | |
| 181 | 181 | Outer Infrastructure (B-1) | |||
| 182 | 182 | Construction of Boundary Wall With Grill | |||
| 183 | 183 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | 189.68 | Cum. | |
| 184 | 184 | Cement Concrete 1:5:10 with 40mm gauge stone aggregate Using mechanical mixer. | 51.32 | Cum. | |
| 185 | 185 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. | 102.09 | Cum | |
| 186 | 186 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. | 109.68 | Cum | |
| 187 | 187 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 1302.96 | Sqm | |
| 188 | 188 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. | 63.12 | Cum | |
| 189 | 189 | Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain) | 869.54 | Sqm | |
| 190 | 190 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels | 335.14 | Sqm | |
| 191 | 191 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete | 251.75 | Qtl | |
| 192 | 192 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005. | 237.98 | Cum | |
| 193 | 193 | 12.5 mm thick cement plaster 1:4. | 792.61 | Sqm. | |
| 194 | 194 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. | 260 | Qtl | |
| 195 | 195 | Iron grated doors, including pintle hinges and arrangements. | 10.8 | Qtl | |
| 196 | 196 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish | 792.61 | sqm. | |
| 197 | 197 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm | 792.61 | sqm. | |
| 198 | 198 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface | 503.15 | Sqm | |
| 199 | 199 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. \nWith ordinary quality paint | 503.15 | Sqm | |
| 200 | 200 | Total B1 :- | 1 | S | |
| 201 | 201 | (B-2)\nConstruction of Internal Concrete Roads, Pavements with Pavers & foot Path | |||
| 202 | 202 | Earth filling with good quality earth obtained from out side including compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compacting with road roller complete as per specifications. | 24914.9 | Cum. | |
| 203 | 203 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type | 325.01 | Cum | |
| 204 | 204 | Providing and laying 60 mm thick cement concrete interlocking paver block of M- 35 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro-hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Medium Traffic Areas such as City streets, small & medium market roads, low volume roads, utility cuts on arterial roads, etc. | 842.47 | sqm. | |
| 205 | 205 | Providing and laying 60 mm thick cement concrete interlocking paver block of M- 35 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro-hydraulic compaction machine and of approved size and design / shape laid in Dark fast and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Medium Traffic Areas such as City streets, small & medium market roads, low volume roads, utility cuts on arterial roads, etc. | 561.65 | sqm. | |
| 206 | 206 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with cement contents 350kg per cum and coarse and fine aggregates conforming to IS:383 mixed with concrete mixer using weigh batcher, laid in position over 125 micron thick polythene sheet, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, including provision of contraction and expansion joints as required, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications | 148.04 | Cum | |
| 207 | 207 | Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position including carriage to site of work complete as per technical clause 408 of MORT&H specifications | 444.12 | rmt. | |
| 208 | 208 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) | 648.21 | sqm. | |
| 209 | 209 | Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. | 304.58 | sqm. | |
| 210 | 210 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior sufrace | 199.85 | sqm. | |
| 211 | 211 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. \nWith special quality paint | 199.85 | sqm. | |
| 212 | 212 | Total B2 :- | 1 | sqm. | |
| 213 | 213 | Total A+B1+B2 | 1 | sqm. | |
| 214 | 214 | Public Health Services | |||
| 215 | 215 | Sub Work-1 Internal Water Supply, Sewerage, Sanitation | |||
| 216 | 216 | Sub Head-1.1 Internal Sewerage System | |||
| 217 | 217 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but excluding cost of lead jointing.\nType - B | |||
| 218 | 218 | 110mm o/d SWR UPVC pipe line laid complete | 118.87 | mtr | |
| 219 | 219 | 75mm o/d SWR UPVC pipe line laid complete | 173.73 | mtr | |
| 220 | 220 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. | |||
| 221 | 221 | For 110mm i/d pipes | |||
| 222 | 222 | Bend Plain | 26 | Nos | |
| 223 | 223 | Cowls | 3 | Nos | |
| 224 | 224 | Collars | 21 | Nos | |
| 225 | 225 | Single junction with door | 4 | Nos | |
| 226 | 226 | For 75mm i/d pipes | |||
| 227 | 227 | Bend Plain | 16 | Nos | |
| 228 | 228 | Cowls | 3 | Nos | |
| 229 | 229 | Collars | 20 | Nos | |
| 230 | 230 | Single junction with door | 5 | Nos | |
| 231 | 231 | With 75mm i/d outlet deep seal at Ground Floor | |||
| 232 | 232 | With 75mm i/d outlet shallow seal at First Floor | 38 | Nos | |
| 233 | 233 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. | |||
| 234 | 234 | M.S. Holder bats clamps for 110mm i/d SWRUPVC pipes | 9 | Nos | |
| 235 | 235 | M.S. Holder bats clamps for 90mm i/d SWRUPVC pipes | 9 | Nos | |
| 236 | 236 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. | |||
| 237 | 237 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm | 8 | Nos | |
| 238 | 238 | Construction of brick masonry inspection chambers size as given below upto 0.60 m average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. | |||
| 239 | 239 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal | 2 | Nos | |
| 240 | 240 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal | 6 | Nos | |
| 241 | 241 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. | |||
| 242 | 242 | uPVC Pipe 6 Kgf/cm2\n50mm i/d | 13.72 | mtr | |
| 243 | 243 | Total Sub Head-1:- | 1 | S | |
| 244 | 244 | Sub Head-1.2 Internal Water Supply System | |||
| 245 | 245 | Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. | |||
| 246 | 246 | 15mm i/d | 82 | mtr | |
| 247 | 247 | 20mm i/d | 244 | mtr | |
| 248 | 248 | 25mm i/d | 351 | mtr | |
| 249 | 249 | 40mm i/d | 168 | mtr | |
| 250 | 250 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. \nSize 75mm x 75mm | |||
| 251 | 251 | qty same as GI P 15mm i/d to 25 mm | 677 | mtr | |
| 252 | 252 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. | |||
| 253 | 253 | Through wall 11.43 cm thick | 60 | nos | |
| 254 | 254 | Through wall 22.86 cm thick | 60 | nos | |
| 255 | 255 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. | |||
| 256 | 256 | 15mm i/d G.I. Union | 24 | Each | |
| 257 | 257 | 20mm i/d G.I. Union | 24 | Each | |
| 258 | 258 | 25mm i/d G.I. Union | 24 | Each | |
| 259 | 259 | 32mm i/d G.I. Union | 12 | Each | |
| 260 | 260 | 40mm i/d G.I. Union | 12 | Each | |
| 261 | 261 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.\n | |||
| 262 | 262 | 25mm i/d Brass Ball valves | 12 | Each | |
| 263 | 263 | 40mm i/d Brass Ball valves | 12 | Each | |
| 264 | 264 | Painting G.I. Pipes and Specials with synthetic enamel Paint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc. | |||
| 265 | 265 | 15mm & 20mm i/d G.I. Pipe | 326 | mtr | |
| 266 | 266 | 25mm & 32mm i/d G.I. Pipe | 351 | mtr | |
| 267 | 267 | 40mm & 50mm i/d G.I. Pipe | 168 | mtr | |
| 268 | 268 | Total Sub Head-2:- | 1 | S | |
| 269 | 269 | Sub Head - 1.3 Sanitary Installation | |||
| 270 | 270 | Providing and fixing in position Chinaware Indian Orisa water closet size 580mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. | 2 | Nos | |
| 271 | 271 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer in charge ) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer in charge. | 12 | Nos | |
| 272 | 272 | Providing and fixing in position Chinaware wall hunged European type water closet with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. \nChinaware wall mounted E.W.C without cistern including seat cover complete in all respect. | 1 | Nos | |
| 273 | 273 | Providing and fixing in position Metropole flush valve 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect. | 1 | Nos | |
| 274 | 274 | Providing and fixing jet spray with 2'-6\" long PVC pipe.With PTMT nut | 13 | Nos | |
| 275 | 275 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. | 13 | Nos | |
| 276 | 276 | Providing and fixing in position vitreous Chinaware white large flat back or angular lipped front urinal 610 mm high of approved make (to the approval of the Engineer-in-charge) (610 mm x 410 mm x 380mm) consisting of C.P. waste 32 mm dia and C.P. brass spreader, complete. | 15 | Nos | |
| 277 | 277 | Providing and fixing partition for different type of urinals.\n15 to 20 mm thick Dungri marble partition \nsize 375mm x 750mm | 15 | Nos | |
| 278 | 278 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. | |||
| 279 | 279 | Size 49 cm dia (above counter round) | 16 | Nos | |
| 280 | 280 | Size 550 mm x 400 mm | 3 | Nos | |
| 281 | 281 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. | 16 | Nos | |
| 282 | 282 | Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. | 3 | Nos | |
| 283 | 283 | Providing and fixing in position best quality stainless steel sinks with complete fitting. \n | |||
| 284 | 284 | Size 600 mm x 450 mm x 225 mm (Net size excluding flat edge) | 1 | Nos | |
| 285 | 285 | Providing & fixing in position best Indian make PVC flexible tube connection.\nPVC tube connection of size 15 mm x 375 mm with PTMT nut | 56 | nos | |
| 286 | 286 | Providing and fixing PVC waste pipe 32mm complete in all respect. | 33 | Nos | |
| 287 | 287 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. | 10 | Nos | |
| 288 | 288 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.\n | |||
| 289 | 289 | C.P. brass towel Rails size 15mm dia 600mm long | 2 | Nos | |
| 290 | 290 | C.P brass towel ring | 8 | Nos | |
| 291 | 291 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. | |||
| 292 | 292 | C.P. brass Bib cock long nose/ long body without flange | 11 | Nos | |
| 293 | 293 | C.P Brass bib cock without flange | 15 | Nos | |
| 294 | 294 | Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer-in-charge). | |||
| 295 | 295 | C.P.brass 15mm Angle valve | 56 | Nos | |
| 296 | 296 | C.P.brass 15mm Concealed stop cock with flange | 13 | Nos | |
| 297 | 297 | Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. | 95 | each | |
| 298 | 298 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. | 95 | each | |
| 299 | 299 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) | 19 | Nos | |
| 300 | 300 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.\nC.P. Brass Accessories: | |||
| 301 | 301 | C.P. brass toilet paper holder | 13 | Nos | |
| 302 | 302 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.\nC.P. Brass khunti with 3 pegs | 13 | Nos | |
| 303 | 303 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. | 8 | Nos | |
| 304 | 304 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. \nDouble Layer Tanks | 11000 | ltr | |
| 305 | 305 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball \n | |||
| 306 | 306 | Brass Ball Cock with rod and Plastic Ball \n32mm i/d | 4 | Nos | |
| 307 | 307 | Brass Ball Cock with rod and Plastic Ball \n25mm i/d | 4 | Nos | |
| 308 | 308 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. | |||
| 309 | 309 | G.I. tank nipple 25mm i/d | 8 | Nos | |
| 310 | 310 | G.I. tank nipple 40mm i/d (for flush valve) | 8 | Nos | |
| 311 | 311 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge | |||
| 312 | 312 | For 2000 ltr Water Tank | 4 | Nos | |
| 313 | 313 | For 500 & 1000 ltr Water Tank | 4 | Nos | |
| 314 | 314 | Providing and fixing in position Grab Bar vertical swing white epoxy coated model WAC-WHT-BG0800 make Jaguar or any equivalent approved make (to the approval of the Engineer-in-charge) fixed in to wall with nylon fastener, brass screws along EWC complete in all respect. | 2 | Nos | |
| 315 | 315 | Providing and fixing in position Grab Bar 842 mm long white epoxy coated vertical model WAC-WHT-BR0750 make Jaguar or any equivalent approved make (to the approval of the Engineer-in-charge) fixed in to wall with nylon fastener, brass screws along EWC/WB complete in all respect. | 2 | Nos | |
| 316 | 316 | Providing and fixing in position Grab Bar 2400 mm long white epoxy coated make Jaguar or any equivalent approved make (to the approval of the Engineer-in-charge) fixed in to wall with nylon fastener, brass screws infront and around WB complete in all respect. | 2 | Nos | |
| 317 | 317 | Total Sub Head-3:- | 1 | S | |
| 318 | 318 | Sub Head-1.4 Flooring and Wall Tile | |||
| 319 | 319 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) including carrage | |||
| 320 | 320 | Ground Floor | 81.75 | sqm | |
| 321 | 321 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping. Using machanical mixer for mixing of material includirng carrage | |||
| 322 | 322 | First Floor | 30.58 | sqm | |
| 323 | 323 | Extra rate for First Floor | 30.58 | sqm | |
| 324 | 324 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 30.58 | sqm | |
| 325 | 325 | Kota stone tile flooring 20mm to 30 mm thick over 12.5mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing. | |||
| 326 | 326 | Ground Floor | 81.75 | sqm | |
| 327 | 327 | First Floor | 30.58 | sqm | |
| 328 | 328 | Extra Rate for First Floor | 30.58 | sqm | |
| 329 | 329 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 300 x 300mm mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. | |||
| 330 | 330 | Ground Floor | 242.4 | sqm | |
| 331 | 331 | First Floor | 94.05 | sqm | |
| 332 | 332 | Extra Rate for First Floor | 94.05 | sqm | |
| 333 | 333 | Coloured Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. | |||
| 334 | 334 | Ground Floor | 6.41 | sqm | |
| 335 | 335 | First Floor | 1.86 | sqm | |
| 336 | 336 | Extra Rate for First Floor | 1.86 | sqm | |
| 337 | 337 | Extra labour for projected nosing of stair case of any shape and design | 5.62 | sqm | |
| 338 | 338 | Total Sub Head-4:- | 1 | SS | |
| 339 | 339 | Sub Head -1.5 Drinking Water Coller & Air Conditions | |||
| 340 | 340 | Supply & installation of self contained drinking water cooler with (Non CFC Refrigerant) energy efficient compressor of make USHA, Model No. SRA 60 120 G, cooling capacity Ltrs/hr. 60, storage type capacity 120 Ltrs. Including installation etc. Complete in all respect as approved and desired by the Engineer-in-charge at site. Make...USHA/ Voltas – or its equivalent. | 2 | nos | |
| 341 | 341 | Supply & installation of self contained drinking water cooler with (Non CFC Refrigerant) energy efficient compressor of make USHA, Model No. SRA 40 80 G, cooling capacity Ltrs/hr. 40, storage type capacity 80 Ltrs. including installation etc. Complete in all respect as approved and desired by the Engineer-in-charge at site. Make...USHA / Blue Star / Bajaj – or its equivalent. | 2 | Nos | |
| 342 | 342 | Supply & Erection of automatic voltage stabilizer for storage type water cooler, Wall mounted, Heavy duty, copper wounded with volt meter etc. along with 3 core cord of suitable length and 3 pin power shoe including erection, connection & testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. Make... V – Guard or its equivalent. | 4 | Each | |
| 343 | 343 | Supply & installation of RO Ultra Violet Filter and Censor system, capacity 120 ltr. Per hour, 100% chemical free, including installation etc. Complete in all respect as approved and desired by the Engineer-in-charge at site. Make... Aquasure – or its equivalent. | 4 | Nos | |
| 344 | 344 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Make:- Carrier, Hitachi, Voltas, Blue Star, Daikin or equilant with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects | 1 | Each | |
| 345 | 345 | Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Make:- Carrier, Hitachi, Voltas, Blue Star, Daikin or equilant with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects | 8 | Each | |
| 346 | 346 | Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. | 90 | mtr | |
| 347 | 347 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.\nuPVC Pipe 10 Kgf/cm2\n25mm i/d | 90 | mtr | |
| 348 | 348 | Total Sub Head-5:- | 1 | S | |
| 349 | 349 | Total of Sub Work-1 | 1 | S | |
| 350 | 350 | Sub Work-2 | |||
| 351 | 351 | Sub Head-2-Estate Water Supply | |||
| 352 | 352 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. | |||
| 353 | 353 | Earth work upto 1.5 m. Depth \nAll classes of soil except rocky | 137.32 | cum | |
| 354 | 354 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.\nD.I. Pipe as per IS 8329 DI-K7 | |||
| 355 | 355 | D.I. Pipe as per IS 8329 DI-K7\n80mm i/d pipe lines laid complete | 132.96 | Mtr. | |
| 356 | 356 | Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects. | |||
| 357 | 357 | D.I. specials upto 300mm i/d | 57.79 | kg | |
| 358 | 358 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).\nClass PN-1 as per ISI | |||
| 359 | 359 | 80mm i/d Sluice Valves flanged | 3 | Nos | |
| 360 | 360 | Providing, fixing and jointing Cast Iron surface box for Sluice valve, Air valve, Fire hydrant etc. including all carriages complete. | 9 | Kg | |
| 361 | 361 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. | |||
| 362 | 362 | Size 0.6 m. x 0.6 m. | 3 | Nos | |
| 363 | 363 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. | |||
| 364 | 364 | 50mm i/d | 248.48 | mtr | |
| 365 | 365 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. | |||
| 366 | 366 | 50mm i/d G.I. Union | 8 | nos | |
| 367 | 367 | Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. | |||
| 368 | 368 | 50mm i/d Gun Metal peet valve heavy pattern. | 8 | Nos | |
| 369 | 369 | Providing GM ferrule as per IS:2692 drilling and tapping cast iron pipe lines of all diametres and screwing in Ferrule and connections complete in all respect.\n25mm i/d Ferrule medium | 1 | nos | |
| 370 | 370 | Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. | |||
| 371 | 371 | Boring with 200mm id Housing Pipe | 150 | MTR | |
| 372 | 372 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. | |||
| 373 | 373 | 150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness | 131 | Mtr | |
| 374 | 374 | Supply, fixing & lowering of stainless steel cage type wire wound screen as per IS:8110-2000 or latest ISI makred, Duly welded with suitable grade S.S Welding electrode to lower the strainer into tubewell bore. | |||
| 375 | 375 | 150mm internal diameter (slot size 0.15mm) 5.00 mm thickness | 15 | Mtr | |
| 376 | 376 | Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI makred duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respects. | |||
| 377 | 377 | 150mm internal diameter | 6 | nos | |
| 378 | 378 | supplying, lowering and fixing of special MS sockets to connect S.S. containter to MS pipe duly welded with suitable grade welding electrode complete in all respects.\n150mm internal diameter | 4 | No | |
| 379 | 379 | Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample received from the bore | 1 | No | |
| 380 | 380 | Collection ofwater sample from different strata and testing of sample from aproval laboratory (Physical & Chemical Analysis) | 3 | each | |
| 381 | 381 | Supplying and fixing well cap having threads to fix on housing pipe complete in all respect 200mm id. | 1 | No | |
| 382 | 382 | Supply & fixing of ball plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects.\n150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness | 4 | Mtr | |
| 383 | 383 | Supplying and fixing mild steel clamps of 150mm x 12mm made out of MS Flat (1.52 mtr long suitable to fit the housing pipe including the cost of Nut or bolt of suitable size complete in all respects | 1 | No | |
| 384 | 384 | Development and stabilizing of the Tubewell with Air Compressor required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge. | |||
| 385 | 385 | With air compressor of size 300 cfm 250 PSI | 10 | hrs | |
| 386 | 386 | Development and stabilizing of the Tubewell with Air Compressor and submersible pumping set of required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge. | 4 | hrs | |
| 387 | 387 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) | 1 | each | |
| 388 | 388 | Providing & Installing industrial type domestic RO | 1 | each | |
| 389 | 389 | Providing & Installing Testing & commissioning of One No Electrically driven submersible pumping set 5 BHP of reputed Make capable of delivering along with elctric panel board consisting of elcetric appliances such as automatic star Delta push button or oil lmmersed starter, Main switch, VM ampere Meter, ELCB, shunt capacitor, single phase preventer, indicating Lamps Kit-Kat etc including M.S Column pipe of suitable size of 50mm = 50mtr (in 3 mtr lengths each with flanges, screwed and welded on both sides) rubber gasket, nuts and bolts submersible cable (reputated make) complete in all respect as per standard specifications. | 1 | each | |
| 390 | 390 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. | |||
| 391 | 391 | 50mm i/d | 60 | mtr | |
| 392 | 392 | Providing & Installation of Automatic on/off controller make Boparai or its. Equivalent including cost of required length of cable up to main board. | 1 | job | |
| 393 | 393 | Total Sub Work-2 | 1 | S | |
| 394 | 394 | Sub Head-3 Estate Sewerage including Septik tank & sockage pit | |||
| 395 | 395 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. | |||
| 396 | 396 | 110 mm i/d pipes | 24 | mtr. | |
| 397 | 397 | 160 mm o/d pipes | 48 | mtr. | |
| 398 | 398 | For Sewer Line as per Detail attached | 163.8 | mtr. | |
| 399 | 399 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. | |||
| 400 | 400 | For depth exceeding 3.0 m but not exceeding 4.5 m B.G.L.\nFor all classes of soil except rocky | 319.85 | cum | |
| 401 | 401 | Sand Fillling around UPVC Pipe | 8.65 | cum | |
| 402 | 402 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. | |||
| 403 | 403 | Inside size75x120cm and 120 cm deep | 16 | nos | |
| 404 | 404 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.84 upto 1.80 m increase in depth. | 5 | nos | |
| 405 | 405 | Construction of Septic Tank size 6.00 Mtr x 4 Mtr. Working depth 2.70 mtr and medium duty man hole cover complete as per drawing / specification and to the entire satisfaction of Engineer-in-charge. (Note :- Payment will be made as per CSR Based Rates Plus/Minus Quoted rates). | 1 | nos | |
| 406 | 406 | Making soak pit 2.5 m Diametre 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design.\nWith F.P.S. bricks | 2 | nos | |
| 407 | 407 | Total 3:- | 1 | S | |
| 408 | 408 | Sub Head-4 Roof Top Rain water Harvesting System | |||
| 409 | 409 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. | |||
| 410 | 410 | 200mm o/d pipe of 4 Kgf. / sqcm | 285.25 | mtr. | |
| 411 | 411 | 160mm o/d pipe of 4 Kgf. / sqcm | 342 | mtr. | |
| 412 | 412 | Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects. | |||
| 413 | 413 | For depths not exceeding 3.0 metre B.G.L.\nFor all classes of soil except rocky | 465.13 | cum | |
| 414 | 414 | Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge | 26 | nos | |
| 415 | 415 | Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge | 57 | nos | |
| 416 | 416 | No. of Haudi @ 5mtr. C/c Distance of Rain water Pipe line | |||
| 417 | 417 | Construction of Rain water harvesting system consisting of drilling bore 500mm dia depth as per drawing, supplying and lowering pvc perforated housing pipe 200 mm dia 50 mtr depth as per drawing sorrunded with filtermedia , stainer PVC medium 200mm i/d 1 mtr duly plugged from top with bail plug, fixing MS clamp, MS socket, Well size 5.00 mtr internal dia, 5mtr deep constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 3 Layers, 1Nos RCC Man hole cover conneted with collecting chamber size 1mtr x 1mtr x 1.20 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge . | 2 | No | |
| 418 | 418 | Total 4:- | 1 | S | |
| 419 | 419 | Fire Fighting Arrangements | |||
| 420 | 420 | Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.\n4.5kg capacity | 8 | Nos | |
| 421 | 421 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.\n6kg Capacity | 8 | Nos | |
| 422 | 422 | Total 5:- | 1 | S | |
| 423 | 423 | Total of Sub Work (1+2+3+4+5) :- | 1 | S | |
| 424 | 424 | Electrical Services | |||
| 425 | 425 | Providing Internal Electrical Installations | |||
| 426 | 426 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100volts grade to be laid in heavy gauge, PVC, fire retardant conduit pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators, bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20Amp. Sockets and 6Amp./16/20Amp. Switches (Screw Type Modular Accessories) etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100watts, PVC connector (For Fan Box and Electronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) PVC conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:- Make :- PVC Pipe = Anchor, Polycab, Norpack, Adarh Plast, Diplast. PVC Copper Wires = Bonton,Polycab, Tamra, Gemscab, KEI, Grandlay, Ecko, Ultracab, RR kabel, Rallison, Havell's, L&T, Batra Henlay, V-Guard, CMI, Great White Securex,HPL, Goldmedal.\nAccessories:-North-West(Nova), Havell's (Crab Tree), Legrand (Myrius), Hager\n | |||
| 427 | 427 | Wiring fan point with sheet metal fan box (shape hexagonal) in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts. | 171 | Each | |
| 428 | 428 | Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. | 347 | Each | |
| 429 | 429 | Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade. | 74 | Each | |
| 430 | 430 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket (shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. | 136 | Each | |
| 431 | 431 | Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch. | 35 | Each | |
| 432 | 432 | Wiring call-bell point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer). | 4 | Each | |
| 433 | 433 | Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with double control switches. | 2 | Each | |
| 434 | 434 | Wiring TV sockets and Telephone socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases:-\nWiring Telephone socket point RJ11 (one module) | 11 | Each | |
| 435 | 435 | Wiring Telephone socket point RJ45 (one module) | 39 | Each | |
| 436 | 436 | PVC INSULATED SINGLE CORE FRCOPPER CONDUCTOR CABLE:Supply and erection of PVC insulated single core FRcopper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing. Make:-Bonton,Polycab, Tamra, Gemscab, KEI, Grandlay, Ecko, Ultracab, RR kabel, Rallison, Havell's, L&T, Batra Henlay, V-Guard, CMI, Great White Securex,HPL, Goldmedal.. | |||
| 437 | 437 | PVC insulated copper conductor single core FR cable (ISI marked) overall 1sq.mm, 1100volts grade | 600 | Mtr. | |
| 438 | 438 | PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm, 1100volts grade | 500 | Mtr. | |
| 439 | 439 | PVC insulated copper conductor single core FR cable (ISI marked) overall 4 sq.mm, 1100volts grade | 3500 | Mtr. | |
| 440 | 440 | PVC insulated copper conductor single core FR cable (ISI marked) overall 10 sq.mm, 1100volts grade | 1000 | Mtr. | |
| 441 | 441 | PVC insulated copper conductor single core FR cable (ISI marked) overall 16 sq.mm, 1100volts grade | 850 | Mtr. | |
| 442 | 442 | PVC insulated copper conductor single core FR cable (ISI marked) overall 25 sq.mm, 1100volts grade | 650 | Mtr. | |
| 443 | 443 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):\nSupply & laying of aluminium conductor XLPE/ P.V.C. insulated un-armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specidications 2010:-\nMake :- Polycab, KEI, Ecko, RR kabel, Rallison, Havell's. | |||
| 444 | 444 | XLPE/ PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100volts grade 150sq.mm (3 ½ Core) | 200 | mtr. | |
| 445 | 445 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:\nSupply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010:-\nMake:- Anchor, Polycab, Norpack, Adarh Plast, Diplast. | |||
| 446 | 446 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed | 900 | Mtr. | |
| 447 | 447 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed | 200 | Mtr. | |
| 448 | 448 | PVC flexible pipe 40mm dia. | 300 | Mtr. | |
| 449 | 449 | HEAVY GUAGE WELDED CONDUIT PIPES:\nSupply & erection of pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications :- | |||
| 450 | 450 | Supply and erection of 20mm dia. heavy gauge welded conduit pipe (1.60mm thick) suspension rod for ceiling fan complete in all respect as desired by the Engineer-in-charge. | 550 | Mtr. | |
| 451 | 451 | COPPER EARTHING: | |||
| 452 | 452 | Earthing of Sheet metal/ iron clad switches and metallic cases etc., with 20 mm x 3 mm thick electrolytic copper tape rivetted (with 10 nos. copper rivets) to 30 cm x 120 cm x 3 mm thick tinned copper plate (made cylindrical) burried 10 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper tape on wall and in floor etc., up to 13 metre in length (including bore length). G.I. pipe 20mm dia. (A-class) should be laid in the hole of excavation from bore surface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation. | 8 | Each | |
| 453 | 453 | Earthing of Sheet metal/ iron clad switches and metallic cases etc., with 8 SWG (4mm dia.) electrolytic copper wire thimbled (with 1 nos. copper thimble) to 30 cm x 60 cm x 3 mm thick tinned copper plate (made cylindrical) burried 10 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) on wall and in floor etc., up to 13 metre in length (including bore length). G.I. pipe 20mm dia. (A-class) should be laid in the hole of excavation from bore surface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation. | 6 | nos | |
| 454 | 454 | Supply and Erection of 20mm x 3mm thick copper tape (As additional length). | 80 | Each | |
| 455 | 455 | Supply and Erection of 8 SWG 4mm dia copper wire run through 20mm dia. GI pipe (A-Class) (As additional length). | 500 | mtr | |
| 456 | 456 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:\nSupply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs. \nGROUP-A: (Siemens (Beta Guard), Legrand (Lexic) & Schneider (Neo Break), L&T (Exora,Hager) | |||
| 457 | 457 | Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 156 | Each | |
| 458 | 458 | Miniature circuit breaker four pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 18 | Each | |
| 459 | 459 | Miniature circuit breaker four pole 40amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 9 | Each | |
| 460 | 460 | Miniature circuit breaker four pole 50,63amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 20 | Each | |
| 461 | 461 | Miniature circuit breaker triple pole 40amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 18 | Each | |
| 462 | 462 | Miniature circuit breaker triple pole 50,63amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 20 | Each | |
| 463 | 463 | Miniature circuit breaker double pole 6 to 32 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply | 27 | Each | |
| 464 | 464 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:\nSupply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.\n | |||
| 465 | 465 | GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA), HAGER | |||
| 466 | 466 | Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 4 way each | 27 | Each | |
| 467 | 467 | Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's/ RCBO/ RCCB's for outgoing 4 way each | 8 | Each | |
| 468 | 468 | Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's/ RCBO/ RCCB's for outgoing 6 way each | 3 | Each | |
| 469 | 469 | Sheet metal double door T.P. & N. (vertical design) distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's/ RCBO/ RCCB's for outgoing 4 way each | 3 | Each | |
| 470 | 470 | MOULDED CASE CIRCUIT BREAKERS:\nSupply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.\nMCCB (Fixed Type Thermal and Magnetic Protection Make: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager | |||
| 471 | 471 | 100amp. 415 volts breaking capacity =25kA four pole fixed type thermal and magnetic setting MCCB unit | 4 | Each | |
| 472 | 472 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:\nSupply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size.\nMake :-TeleRex,Gemni,CPE,Dura Line | |||
| 473 | 473 | Double walled corrugated (DWC) HDPE pipe 50/38 mm (outer/ inner dia.) | 500 | mtr | |
| 474 | 474 | Double walled corrugated (DWC) HDPE pipe120/103.5mm (outer/ inner dia.) | 180 | mtr | |
| 475 | 475 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make: Jaquar LGLZ01X020XC / Philips BN02IC LED20S PSU CW GR/ Havells ENDURALINEARNEOBS20WLED830SPCWH, Crompton:-LDL-20-CDL,WIPPRO:-LL20-221-XXX-65 ALI, C&S:-LTTB4F20WLED/W | 53 | Each | |
| 476 | 476 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- WIPRRO:- LL24-541-XXX-57-CD,BAJAJ Cat No. BCLAB40W ,JAQUAR CAT NO. LGLZ01X040XC, PHILLIPS Cat no:-BN108C LED 40 S PSU CDL WH , CROMPTON:-LDL-40-CDL,C&S:-LTTB4F40WLED /W,HAVELLS:-STOUTPLUS1200BS40WLED840SPCWH | 166 | Each | |
| 477 | 477 | Supply and erection of Retrofit LED Batten box of CRCA sheet 2*20watt (including LED driver) & led tubelight with High quality extruded aluminium heat sink with efficacy of LED fixture more than 100 Lumens per watt,Fitting glass of Industrial grade polycarbonate cover, THD< 10%, CRI>70 complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by HON. Technical Advisor to CM Punjab vide letter No. ATPB/20/GL Dated 30/11/2017. . Make:- Wipro WIO 921 208 & LL13-181-65SE, Jaquar-LUNI01X220XW ,Crompton DMLN1LT8-16 & LTTT8-20, | 96 | Each | |
| 478 | 478 | Supply and erection of Recessed mounted 36watt LED panel(including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per circular issued by Hon. Tech. Advisor to CM Punjab Letter no ATBP/20/CL Dated 30/09/2017. Make:- PhilipsRC380B LED36S -6500 G4 L60 W60 PSD OD WH OC /jaquar LULTO1SO36XC/CROMPTON :-LCTLRNE-36-FO-CDL (2X2),WIPRO:- LM25-361-XXX-65-G1/ C&S :- LTCRP36WLED2X2/ HALONIX :- HLFPU22-02-36-CW | 12 | Each | |
| 479 | 479 | Supply and erection of Heavy duty Exhust Fans 300mm 900RPM with aluminium louver shutter Canon of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make:- Crompton EXHD300-6-1 /Havells Turbo Force SP / Anchor Anmol Heavy Duty . | 20 | Each | |
| 480 | 480 | Supply and erection of Ceiling Fan 1200mm, 48\" with double ball bearing including flexible wire & petty material etc. for connections and testing . complete in all respects as appd. and desired by the Engineer in-charge at site. Makes:- Crompton Entrust 50-5 Star Opel White/ Havell's ES-50/ ANCHOR:-Panta Turbo Star code 13671WH / V-Guard Coolgate 5 Star 48, Halonix:- Zephyr(ISI With 5 Star Rating) | 171 | Each | |
| 481 | 481 | Supply & Erection of Vertical Three phase Double door distribution board 8way (IP43 with metal door) complete with loose wire box, terminal blocks, tinned cu. Busbar, neutral link, earth bar, din bar, detachable gland plate, powder coated painting, earthing etc. as reqd. with with provision for 4pole,100/160.,=35kA four pole, djustable thermal and magnetic protection MCCB unit as Incomer and 8 Nos. TP MCB 40/63Amp.,Type-C, 10KA, . as outgoing switches complete with insulated busbar arrangement recessed in wall including the cost of cutting & filling of chases with complete connections with suitable size of thimbles/ lugs (copper/aluminium) and bonding to existing earth as per satisfaction of the Engineer -in- charge. Make:- Hager , LEGRAND , L&T | 3 | Each | |
| 482 | 482 | Supply & Erection of Vertical Three phase Double door distribution board 4way (IP43 with metal door) complete with loose wire box, terminal blocks, tinned cu. Busbar, neutral link, earth bar, din bar, detachable gland plate, powder coated painting, earthing etc. as reqd. with with provision for 4pole,100/160.,=35kA four pole, djustable thermal and magnetic protection MCCB unit as Incomer and 4 Nos. TP MCB 40/63Amp.,Type-C, 10KA, . as outgoing switches complete with insulated busbar arrangement recessed in wall including the cost of cutting & filling of chases with complete connections with suitable size of thimbles/ lugs (copper/aluminium) and bonding to existing earth as per satisfaction of the Engineer -in- charge. Make:- Hager , LEGRAND , L&T | 1 | Each | |
| 483 | 483 | Supply, Erection, Testing & commissioning of indoor Type Sub LT cubical panel Enclosure (dust ,vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments) . The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP44 and minimum 50kA. \nFabrication:-Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623.The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should \"Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44).\nFabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.\"\n\"The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. \nPainting :- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . \nBusbars :-The panel shall be provided with TPN copper busbar of suitable size according to the size of MCCB's. All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.\n\"Metering :-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. \nManufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.\nDetail of capacities of MCCB's to be installed in the cubical panel Enclosure (including the cost of MCCB's+E.R.H.) as per following . \"\nIncomer-1\n¦315Amp.415volts 36FPMCCB Unit with Adjustable Thermal and Magnetic Protection = 1Nos.\n(MCCB Adjustable Thermal and Magnetic Protection Make: L&T (DSINE), ABB (T-MAX), Schneider (NSX), Seimens(3VL),Hager):\n¦ On load change over switch 4P 160amp 415v = 1 No.\n¦ (Make: L&T-U Power, ABB-E Max, Seimens-3WL, Schneider-MVS,Hager )\nOutgoings:\n¦63 Amp.415volts =25 FP MCCB Unit with Adjustable Thermal and Magnetic Protection = 10 Nos .\n¦100Amp.415volts =35 FP MCCB Unit with Adjustable Thermal and Magnetic Protection=3Nos.. \n¦40-80Amp.415volts =35 FP MCCB Unit with Adjustable Thermal and Magnetic Protection) =1Nos.. \n¦(MCCBA djustable Thermal and Magnetic Protection Make: L&T (DSINE), ABB (T-MAX), Schneider (NSX), Seimens(3VL),Hager):r: \n¦ All Incomers & Out going With Extendable Rotary Handle with adjustabledepth \ncomplete as per schematic diagram attached / analysis & Satisfaction of the Engineer in charge at site.\nPanel Manufacturer :-Kalyani Switchgear / ETE ELECTROGEARS / POWE ASSOCIATE / UNIX | 1 | Each | |
| 484 | 484 | Total D1:- | 1 | S | |
| 485 | 485 | Providing Networking System | |||
| 486 | 486 | Supply & erection of Supply & erection of 24 Port Web managed 10/100 Mbps Smart Data switch with 2 Combo 10/100/1000 Mbps copper & SFP Port..complete in all respect as desired by the engineer in charge at site. Make:D-LINK/NETGEAR/EXTREME\n | 2 | nos | |
| 487 | 487 | Supply and erection of CAT 6 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination complete in all respect as desired by the engineer in charge at site. Make:_ D-LINK/NETGEAR/EXTREME/Schneider | 2 | nos | |
| 488 | 488 | Supply & Erection of CAT 6 UTP networking cable 4 pair support up-to 10/100/1000 mbps speed PVC insulated.. complete in all respects as approved and desired by the Engineer-in-charge at site. Make D-Link/Digi-Link/AMP/SCHNEDER | 600 | Mtr | |
| 489 | 489 | Supply & Erection of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps.. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: D-link/Panduit/Schneider | 48 | nos | |
| 490 | 490 | Supply & erection of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps. complete in all respects as approved and desired by the Engineer-in-charge at site.Make: D-link/Panduit/Schneider | 40 | nos | |
| 491 | 491 | Supply & erection of 600VA Online LIT sine wave UPS/ Power Plant with in built SMF batteries having 30 Minutes backup time complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make-APC/NUMERIC/ UNILINE/EATON/AQUA POWER. | 2 | nos | |
| 492 | 492 | Supply & erection of 6U Wall mount 19’’ Rack with glass door,lock & key facility 450mm-550mm depth with CPD, Cable Manager & Fan.Make: D-Link/Comrack/Netrack | 2 | nos | |
| 493 | 493 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:\nSupply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications (Electrical Works):- | |||
| 494 | 494 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed | 300 | mtr | |
| 495 | 495 | Total D2:- | 1 | S | |
| 496 | 496 | Providing EPBAX System | |||
| 497 | 497 | Supply & erection of Digital Hybrid IP-PBX System Digital 100% Non Blocking, 06 No. Universal Slots, Universal SMPS,Auto Attendant, CLI, GSM Trunk, Digital Extension & IP Connectivity, Voice Mail, PRI Connectivity including all features listed in Product Boucher. Configured for 04 Trunk,04 Digital Extn Ports, 00 GSM Trunk Ports, 00 PRI of 32 Channels & 24 Normal Extensions Expendable to 48 TDM\nPorts & 50 IP Extension.Make: Matrix Eternity PE6S/LG/CISCO | 1 | nos | |
| 498 | 498 | Supply and Erection of Operator-cum-maintenance console with Small Backlit Display, 12 Direct Dialling Keys, HD sound quality, Duplex Speaker Phone, Touch sense keys including all features listed in Product Boucher complete in all respect as desired by the engineer in charge at site. Make: Matrix/LG/CISCO | 1 | nos | |
| 499 | 499 | Supply and erection 50 Pairs MDF + 50 Pair IDF with Krone Modules & Lockable Box complete in all respect as desired by the engineer in charge at site. Make: Krone | 1 | nos | |
| 500 | 500 | Supply & Erection of 10 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel | 1 | nos | |
| 501 | 501 | Supply & erection of Basic Phone with CLIP and display complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Beetel Model M51/C51/P-Tel/ Binatone/PANASONIC/Siemens. | 10 | nos | |
| 502 | 502 | Supply & erection of Featured Wired Telephone with Large Backlit Display, Redial, CLIP, 2 Way Speaker, Calculator, Alarm & Mute Compatible with EPABX System Without Addition Programming complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Beetel Model: M71/M73/P-Tel/ Binatone/panasonic/ Siemens. | 2 | nos | |
| 503 | 503 | Supply & erection of 02 Pair 0.5mm PVC Dual sheathed Telephone Cable as per ITD Specification 113-B With Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar. | 600 | nos | |
| 504 | 504 | Supply & erection of 20 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar. | 50 | Mtr | |
| 505 | 505 | Supply & erection of 50 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar. | 10 | Mtr | |
| 506 | 506 | Supply & erection of 1KVA Online LIT sine wave UPS/ Power Plant with in built SMF batteries having 30 Minutes backup time complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make-APC/NUMERIC/ UNILINE/EATON/AQUA POWER. | 1 | nos | |
| 507 | 507 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:\nSupply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications (Electrical Works):- | |||
| 508 | 508 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed | 300 | mtr | |
| 509 | 509 | Total D3:- | 1 | S | |
| 510 | 510 | Providing Campus Lighting | |||
| 511 | 511 | 3-STEPPED STEEL TUBULAR POLE:\nSupply and erection of 3-Stepped steel tubular swaged and welded pole of suitable length conforming to I.S. 2713-1969 (Part I to III) / 1980 and I.S. 1161-1979 (UTS 42 kgf/mm sq.) to fixed up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to filled in up to 15 cm below G/L with 1:2:4 cement concrete mixture and having 1:2:4 cement concrete muff of dia. 450mm, 80cm long above ground level sufficient to completely flush a MCB distribution board SPN 4way (double door) with hinged water tight cover with locking arrangement having one single pole MCB of required capacity fixed on din bar. The outer surface of the plinth to be finished with pure cement including painting of pole with two coats of approved aluminium paint as required:- | |||
| 512 | 512 | Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre,1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.50mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. | 31 | Nos | |
| 513 | 513 | GI PIPE POLE BRACKETS:\nSupply and erection of G.I. pipe ‘A’ quality of suitable length and dia. conforming to I.S. 1239 part-I 1979, including fixing up to a given depth below G/L, the hole of excavation about 30 cm dia. and given depth to be filled in up to 15 cm below and above G/L with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thick ness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a MCB distribution board SPN 4way with hinged water tight cover with locking arrangement having one single pole MCB of required capacity of the same size the outer surface of the plinth to be finished with 1:2 cement plaster 6 mm thick M.S. fuse box shall have a water proof hinged cover with locking arrangement including painting of pole with two coats of approved aluminium paint as required:-\nSINGLE ARM BRACKETS: | |||
| 514 | 514 | Supply and erection of G.I. pipe 40mm dia. (A-class) single arm bracket atleast 1 metre long arm to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm with GI reducer 80mm x 40mm with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site. | 31 | Nos | |
| 515 | 515 | Supply and erection of LED Street Light 45 watt with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection), toughened glass fitting, surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site .LED Fitting as per circular issued by Hon. Tech. Advisor to CM Punjab Letter no ATPB/20/GL Dated 30/11/2017 Make:- HavellENDURAPEARLNEOSL45WLED757SASYTOPC / Wipro LR02-501-XXX-57-GI /Jaquar LSRT01S045XC /CROMPTON LSTP-45-CDL. | 31 | Nos | |
| 516 | 516 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE): | |||
| 517 | 517 | Supply & laying of aluminium conductor XLPE/ P.V.C. insulated un-armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specidications 2010:- Make :-Havell's/ RRKable/ Finolex | |||
| 518 | 518 | Aluminium conductor XLPE/ PVC insulated PVC sheathed un-armoured and served cable working voltage 1100volts grade 16sq.mm (4 Core) | 1000 | mtr | |
| 519 | 519 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: | |||
| 520 | 520 | Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size. Make :- REX/ Duraline / Amtel | |||
| 521 | 521 | Double walled corrugated (DWC) HDPE pipe63/51mm (outer/ inner dia.) | 750 | mtr | |
| 522 | 522 | GALVANIZED IRON PIPES AND G.I. EARTHING:\nSupply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications (Electrical Works):-\nG.I. EARTHING: | |||
| 523 | 523 | Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 15mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling). | 2 | nos | |
| 524 | 524 | G.I. EARTHING (AS ADDITIONAL LENGTH):\nEarthing of metallic cases etc., with G.I. wire No. 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe on surface including painting etc. (as additional length) | 10 | mtr. | |
| 525 | 525 | Supply and Erection of earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire No. 8SWG. The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The road shall be grouted upto complete length vertically. | |||
| 526 | 526 | GI Earth rod 20 mm dia. 3 mtr. Long | 31 | nos | |
| 527 | 527 | PVC INSULATED SINGLE CORE FRCOPPER CONDUCTOR CABLE: Make:- Finolex / / RRkable Havell's | |||
| 528 | 528 | Supply and erection of PVC insulated single core FRcopper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing. | |||
| 529 | 529 | PVC insulated copper conductor single core FRcable (ISI marked) overall 1.5 sq.mm, 1100volts grade | 700 | mtr | |
| 530 | 530 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT MISCELLANEOUS ITEMS:\nS/E of SMCpedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\" hinges & locking system with heavy duty 12\" sliding door.Placed on MS strip of size 12.5mmx2.5mm thick welded with MS sheet with 4no. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs.Front door welded x-actionally with MS flat 25mmx5mm.The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high.And pedestial with 4 Nos supporting members each of MS flat 50mmx6mm thick acc. to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint &bonding to the existing earth to be erected in the 1:2:4 CC, the platform of 150mm high from ground level & 450mm thick & 150mm from the top of the CCplatform as per Drawing attached. | |||
| 531 | 531 | Cubical Size 900mm high, 600mm wide and 350mm deep | 1 | No | |
| 532 | 532 | Supply and erection of Switch Disconnector fuse unit with HRC Fuses in sheet enclosure on the existing surface (conforms to IS 13947 (PartI&III) complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connection on both sides of switch with sutiable size of Thimbles, including cost of HRC fuses as per PWD General Specifications (Electrical Works). | |||
| 533 | 533 | 32Amp. 415volts three pole & neutral switch disconnector fuse unit with HRC Fuses in sheet enclosure | 1 | No | |
| 534 | 534 | Total D4:- | 1 | S | |
| 535 | 535 | Supply, Erection, Testing and Successful Commissioning of Diesel Generating Set1 No. 40KVA For General Light Load) | |||
| 536 | 536 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 40 KVA /32KW .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).\nENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor OF TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.\nENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication.\nALTERNATOR: The alternator should be designed as per (IS4722 AND IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 voltS, SPDP (Screen Protected Drip Proof), Degree of protection : IP-23, Ventilation : Self ventilated air cooled \n | 1 | Job | |
| 537 | 537 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):\nSupply & laying of aluminium conductor XLPE/ P.V.C. insulated un-armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specidications 2010:-\nMake :- Polycab,KEI, Grandlay, Ecko, RR kabel, Rallison, Havell's, | |||
| 538 | 538 | Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 35sq.mm (3 ½ Core) | 200 | nos. | |
| 539 | 539 | COPPER EARTHING: | |||
| 540 | 540 | Earthing of Sheet metal/ iron clad switches and metallic cases etc., with 20 mm x 3 mm thick electrolytic copper tape rivetted (with 10 nos. copper rivets) to 30 cm x 120 cm x 3 mm thick tinned copper plate (made cylindrical) burried 10 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper tape on wall and in floor etc., up to 13 metre in length (including bore length). G.I. pipe 20mm dia. (A-class) should be laid in the hole of excavation from bore surface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation. | 4 | nos. | |
| 541 | 541 | Supply and Erection of 20mm x 3mm thick copper tape (As additional length). | 10 | mtr | |
| 542 | 542 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:\nSupply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size. \nMake :-TeleRex,Gemni,CPE,Dura Line | |||
| 543 | 543 | Double walled corrugated (DWC) HDPE pipe 50/38 mm (outer/ inner dia.) | 180 | mtr | |
| 544 | 544 | Total D5: | 1 | S | |
| 545 | 545 | Solar Generation System | |||
| 546 | 546 | Supply, Installtion testing & commissioning of Grid Interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 35KWp including required quantities of SPV modules (Hight Power density Perc Bifacial Mococrytalline based) formed in to arrays, their mounting arrangement, Power conditioning units (i.e string Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through cable tray Bi Directional Energy Meter required Earthing (i.e 2 Nos GI strip earthing for GI Strcuture, 2 Nos GI Strip earthing for string inverter, AC & DC Distribution system) ESE stroke master (As per NFC 17 102 standard with suitable radius of protection) & 3 Nos chemical earthing with copper bonded rods along with high rise GPSP structure (Rated wind speed 170Kph) including mounting height up to 8 feet complete with transportaion, fabrication labour & civil work.\nFeatures :- \n1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286\n2. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529\n3. Structure 25 Years service life with AMC & certified under IS 2062 2011\n4. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)\n5. Annual Maintenance contract for the period of 5 Years\nMake :-\n1 Solar PV Module = EMBRO, VIKRAM, ADANI, WAREE\n2 Power Conditioning Unit = KEHUA, DELTA, LUMINOUS, SOLAX, TESA\n3 AC/DC Distribution Board = EMBRO, ABB, SCHNEIDER ELECTRIC, HAVELL'S\n4 Fusion Mount structure = TATA GALVUME, POSMAC\n5 ESE Stroemaster with chemical Earthing = SABO, JMC, TP, HIGH GRID\nThe work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor\nThe Rate are inclusive of all taxes including GST | 30 | kW | |
| 547 | 547 | Calculation fo PSPCL charges (According to PSPCL Regulatory Act): for On Grid Solar Power Plants including Bio Dementional Meter Testing and cost of Uni Directional Meter\nApplication Processing Fee = RS 50/- per KVA | 1 | Each | |
| 548 | 548 | Total D6:- | 1 | S | |
| 549 | 549 | Total D1+D2+D3+D4+D5+D6:- | 1 | S | |
| 550 | 550 | Cost of Ciivil work | 1 | S | |
| 551 | 551 | Cost of Public health services | 1 | S | |
| 552 | 552 | Cost of Electrical services | 1 | S |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy