Bharat Sanchar Nigam Limited-BSNL has published Supply , Installation , Testing , Commissioning Of 2X5 Kva Parallel Redundant On Line Ups For Infrastructure For Gsat-20 Ka Beacon Station At Nayapura , Kota . . Submission Date for this Tender is 10-06-2020. Bolts Tenders in Nayapura kota Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-May-2020 | EXTENSION OF DATES | Date | 10-06-2020 |
Name of Work: Supply, Installation, Testing, Commissioning of 2x5 KVA (1:1) Parallel redundant On line UPS for Infrastructure for GSAT-20 Ka Beacon station at Nayapura, Kota. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | SITC of Floor mounted 5/6 KVA On line UPS Suitable for single phase Input voltage range (100-285 ) V and 230V Single phase output AC supply with Input PF 0.9 & above, High-efficiency (double conversion )technology, suitable for 30 minute battery backup with 192 V DC SMF Battery bank voltage (Cost of SMF battery and stand not included in this item ), internal static bypass switch for smoth transfer, Suitable for parellel redundancy, Network grade power conditioning for protecting from damaging surges and disruptive noise. Provision of voltage regulation, frequecy regulation, and zero transfer time to battery during power events i/c Provision of network manageable card via serial, USB or Ethernet. System should include power chute software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities. UPS shall have 2 Years manufacturer warantee as per specification attached. (Make CEPO approved make as per attached list). | 2 | Set | |
2 | 2 | Supplying and Fixing of SMF battery bank for UPS having 16 Nos 12 Volt 17 AH Sealed Maintenance Free Batteries in charged condition i/c connection with suitable copper conductor with lugs and nut bolt and fixing the same on suitable angle iron battery stand as rack/tower configuration i/c testing on UPS etc as reqd (Note- Battery should be 2 year warranty )(M/s Hitachi/Exide/Amron make) | 2 | Set | |
3 | 3 | S/F of Parallel Box for (1+1) redundancy of 2 no 5/6 KVA UPS having Single phase 230 V AC output supply i/c all standard acessories i/c connection for input and output supply with suitable copper conductor etc as required. | 1 | No. |