Comprehensive Annual Maintenance Contract ( Amc ) For Electrical Gadgets ( Transformer , Stabilizer And Allied Equipments ) Installed At Various Irrigation Cum Dewatering Scheme Fall Under The Mechanical Irrigation Division Shadipora For The Year 202, SHADIPORA-Jammu And Kashmir

Irrigation And Flood Control Department-IFCD has published Comprehensive Annual Maintenance Contract ( Amc ) For Electrical Gadgets ( Transformer , Stabilizer And Allied Equipments ) Installed At Various Irrigation Cum Dewatering Scheme Fall Under The Mechanical Irrigation Division Shadipora For The Year 202. Submission Date for this Tender is 22-05-2020. Transformer Supply Tenders in SHADIPORA Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24337814
Comprehensive Annual Maintenance Contract ( Amc ) For Electrical Gadgets ( Transformer , Stabilizer And Allied Equipments ) Installed At Various Irrigation Cum Dewatering Scheme Fall Under The Mechanical Irrigation Division Shadipora For The Year 202
Open Tender
Indian
Jammu And Kashmir
SHADIPORA
22-05-2020

Tender Details

Comprehensive Annual Maintenance Contract ( Amc ) For Electrical Gadgets ( Transformer , Stabilizer And Allied Equipments ) Installed At Various Irrigation Cum Dewatering Scheme Fall Under The Mechanical Irrigation Division Shadipora For The Year 2020-21

Key Value

Document Fees
INR 500 /-
EMD
INR 25000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Comprehensive Annual Maintenance Contract (AMC) for Electrical Gadgets (Transformer, Stabilizer and allied equipments) installed at various Irrigation Cum Dewatering scheme fall under the Mechanical Irrigation Division Shadipora for the year 2020-21
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under:
2 2 Private car, auto-rickshaw or similar with 1.0 km lead 1 trip
3 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 1 km
4 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 1 km
5 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 1 km
6 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 1 km
7 7 Load carrier auto, mini van or similar with 1.0 km lead 1 trip
8 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 1 km
9 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 1 km
10 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 1 km
11 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 1 km
12 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 1 trip
13 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 1 km
14 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 1 km
15 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 1 km
16 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 1 km
17 17 Truck, tipper or similar with 1.0 km lead 1 trip
18 18 Extra per kilometer for lead >1.0 kms upto 5.0 kms 1 km
19 19 Extra per kilometer for lead >5.0 kms upto 10.0 kms 1 km
20 20 Extra per kilometer for lead >10.0 kms upto 20.0 kms 1 km
21 21 Extra per kilometer for lead >20.0 kms upto 30.0 kms 1 km
22 22 Disconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, taking out the rotor from the stator, and complete disassembly as per requirement of job:
23 23 upto 10 HP 1 job
24 24 >10HP upto 60 HP 1 job
25 25 >60 upto 200 HP 1 job
26 26 >200 HP upto 350 HP 1 job
27 27 greater than 350 HP 1 job
28 28 Assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load.
29 29 upto 10 HP 1 job
30 30 >10HP upto 60 HP 1 job
31 31 >60 upto 200 HP 1 job
32 32 >200 HP upto 350 HP 1 job
33 33 greater than 350 HP 1 job
34 34 Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling.
35 35 upto 50 kVA 1 job
36 36 >50 upto 100kVA 1 job
37 37 >100kVA upto 250 kVA 1 job
38 38 greater than 250 kVA 1 job
39 39 Dismantling of 33/0.4 kv or 11/0.4kV transformer by way of disconnecting of all HT and LT connections, opening of top lid, draining out of T. Oil and its safe placement for further refilling, taking out of coils after removal of core assembly, etc. Job also includes detaching of core HV/LV coils.
40 40 upto 50 kVA 1 job
41 41 >50 upto 100kVA 1 job
42 42 >100kVA upto 250 kVA 1 job
43 43 greater than 250 kVA upto 630kVA 1 job
44 44 Complete assembling of 33/0.4 kv or 11/0.4kV transformer after cleaning of tank, fitting of coil assembly in the tank. Job further includes closing of the transformer lid by way of fitting of existing nuts/bolts and gaskets, insulators, etc. Refilling of t.oil upto required level in tank. Reconnecting of HT/ LT connections and testing.
45 45 upto 50 kVA 1 job
46 46 >50 upto 100kVA 1 job
47 47 >100kVA upto 250 kVA 1 job
48 48 greater than 250 kVA upto 630kVA 1 job
49 49 Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil
50 50 upto 50 kVA 1 job
51 51 >50 upto 100kVA 1 job
52 52 >100kVA upto 250 kVA 1 job
53 53 greater than 250 kVA 1 job
54 54 Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank.
55 55 >60 upto 200 HP 1 job
56 56 >200 HP upto 350 HP 1 job
57 57 greater than 350 HP 1 job
58 58 Fitting of autotransformer coil assembly in the starter oil tank, refilling of collected t.oil in the tank, reconnecting all leads and load testing of the starter.
59 59 >60 upto 200 HP 1 job
60 60 >200 HP upto 350 HP 1 job
61 61 greater than 350 HP 1 job
62 62 Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) 1 ltr
63 63 Filtration of existing/ reclaimed T-oil at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)\n(Process loss maximum of 5% allowed) 1 ltr
64 64 Complete rewinding of stator coils of 3-phase LV horizontal/ vertical induction motor with suitable copper wire after complete removal of burnt out winding, cleaning of slots, etc., insulation class F, varnishing, tapping, etc. excluding carriage and dismantling/ reassembling charges.\n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates).
65 65 5 HP 4-pole 1 job
66 66 20 HP 4-pole 1 job
67 67 25 HP 4-pole 1 job
68 68 30 HP 4-pole 1 job
69 69 40 HP 4-pole 1 job
70 70 50 HP 4-pole 1 job
71 71 50 HP 6-pole 1 job
72 72 60 HP 4-pole 1 job
73 73 60 HP 6-pole 1 job
74 74 75 HP 4-pole 1 job
75 75 100 HP 4-pole 1 job
76 76 100 HP 6-pole 1 job
77 77 120 HP 4-pole 1 job
78 78 125 HP 8-pole 1 job
79 79 Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement.
80 80 upto 5HP 1 job
81 81 > 5 HP upto 20 HP 1 job
82 82 > 20 HP upto 50 HP 1 job
83 83 > 50 HP upto 100 HP 1 job
84 84 > 100 HP upto 200 HP 1 job
85 85 > 200 HP upto 350 HP 1 job
86 86 > 350 HP 1 job
87 87 Providing and fitting of brake lining for AC solenoid brake having nominal wheel diameter as under:
88 88 4 inch 1 job
89 89 5.5 inch 1 job
90 90 7 inch 1 job
91 91 10 inch 1 job
92 92 Providing and fitting of brake shoe assembly for AC solenoid brake having nominal wheel diameter as under:
93 93 4 inch 1 job
94 94 5.5 inch 1 job
95 95 7 inch 1 job
96 96 10 inch 1 job
97 97 Providing and fitting of brake coil for AC solenoid brake having nominal wheel diameter as under:
98 98 4 inch 1 job
99 99 5.5 inch 1 job
100 100 7 inch 1 job
101 101 10 inch 1 job
102 102 Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation.\n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates).
103 103 10kVA rating 1 limb
104 104 25kVA rating 1 limb
105 105 50kVA rating 1 limb
106 106 75kVA rating 1 limb
107 107 100kVA rating 1 limb
108 108 150kVA rating 1 limb
109 109 175kVA rating 1 limb
110 110 200kVA rating 1 limb
111 111 250kVA rating 1 limb
112 112 500kVA rating 1 limb
113 113 600kVA rating 1 limb
114 114 Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality Almunium wire of proper gauge as per requirement with superior insulation.\n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates).
115 115 10kVA rating 1 limb
116 116 25kVA rating 1 limb
117 117 50kVA rating 1 limb
118 118 75kVA rating 1 limb
119 119 100kVA rating 1 limb
120 120 150kVA rating 1 limb
121 121 175kVA rating 1 limb
122 122 200kVA rating 1 limb
123 123 250kVA rating 1 limb
124 124 500kVA rating 1 limb
125 125 Providing and replacement of copper contact points on regulator plate 1 kg
126 126 Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) 1 kg
127 127 Rewinding burnt/ damaged limb/s of autotransformer coil assembly (comprising of three limbs) of below specified rating using superior quality copper wire of proper gauge as per requirement with superior insulation, varnish, etc. \n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates).
128 128 125 HP 1 limb
129 129 275 HP 1 limb
130 130 300 HP 1 limb
131 131 375 HP 1 limb
132 132 400 HP 1 limb
133 133 425 HP 1 limb
134 134 Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage:
135 135 L&T ML 2 1 no.
136 136 L&T ML 4 1 no.
137 137 L&T ML 10 1 no.
138 138 L&T MNX 50 1 no.
139 139 L&T MNX 70 1 no.
140 140 L&T MNX 80 1 no.
141 141 L&T MNX 95 1 no.
142 142 L&T MNX 110 1 no.
143 143 L&T MNX 225 1 no.
144 144 L&T MNX 250 1 no.
145 145 Schneider Electric LC1F265 (without coil) 1 no.
146 146 Schneider Electric LC1F330 (without coil) 1 no.
147 147 Schneider Electric LC1F400 (without coil) 1 no.
148 148 Schneider Electric LC1F630 (without coil) 1 no.
149 149 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 1 no.
150 150 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) 1 no.
151 151 Providing and fitting of new coil with specified coil voltage for contactors as under:
152 152 9A to 45A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 1 no.
153 153 L&T ML 2/ 3 1 no.
154 154 L&T ML 4/ 6 1 no.
155 155 L&T ML 10/ 12 1 no.
156 156 L&T MNX 50/ 70/ 80 1 no.
157 157 L&T MNX 95/ 110/ 140 1 no.
158 158 L&T MNX 185/ 225/ 250 1 no.
159 159 L&T MNX 300/ 400 1 no.
160 160 L&T MNX 550/ 650 1 no.
161 161 Schneider Electric LC1F185/ LC1F225 1 no.
162 162 Schneider Electric LC1F265/ LC1F330 1 no.
163 163 Schneider Electric LC1F400 1 no.
164 164 Schneider Electric LC1F630 1 no.
165 165 Providing and fitting of new Contact kit set for contactors
166 166 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 1 set
167 167 L&T ML 2 1 set
168 168 L&T ML 3 1 set
169 169 L&T ML 4 1 set
170 170 L&T ML 6 1 set
171 171 L&T ML 10 1 set
172 172 L&T ML 12 1 set
173 173 Providing and fitting of auxillary/ control relay (L&T MX0 or similar) for AC control 1 no.
174 174 Providing and fitting of auxillary/ control relay (L&T MN0 or similar) for DC control 1 no.
175 175 Providing and fitting of (1NO+1NC) side mounting auxillary contact block (For L&T/ Schneider Electric make contactors). 1 no.
176 176 Providing and fitting of front mounting auxillary contact block having 04 contacts (all combinations) (For L&T/ Schneider Electric/ Siemens make contactors) 1 no.
177 177 Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) .
178 178 (2NO + 2NC) double block; ON delay 1 no.
179 179 (2NO + 2NC) double block; ON & OFF delay 1 no.
180 180 Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent)
181 181 (2NO + 2NC) contact block 1 no.
182 182 Magnetic coil 415V AC 1 no.
183 183 Magnet frame assembly without coil 1 no.
184 184 Providing, fitting and setting of DIN mounted electronic Timer (L&T or equivalent make)
185 185 Star Delta (range from 3s - 120s) 240V AC 1 no.
186 186 Star Delta (range from 3s - 30s) 240 - 415V AC 1 no.
187 187 ON delay (0.3s - 30hrs) 240V AC 1 no.
188 188 Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) 1 no.
189 189 Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T MN2)
190 190 Relay range in between 0.2A to 15A 1 no.
191 191 14-23A 1 no.
192 192 20-33A 1 no.
193 193 24-40A 1 no.
194 194 Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T MN5)
195 195 30-50A 1 no.
196 196 36-60A 1 no.
197 197 45-75A 1 no.
198 198 66-110A 1 no.
199 199 Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T ML2/3)
200 200 Relay ranges in between 9A to 42A 1 no.
201 201 Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots 1 sft
202 202 Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. 1 job
203 203 Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. 1 job
204 204 Providing and fitting of Jaw contact for ACB (L&T C-power)
205 205 Providing new CRGO lamination to the core in place of damaged core wherever necessary including cost of materials and labour 1 kg
206 206 Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. 1 kg
207 207 Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. 1 kg
208 208 Providing and fitting of finished new aluminium strip windings with insulation in place of damaged windings including labour costs, etc., (Both HV & LV) - per kg of winding. 1 kg
209 209 Rewinding with re-insulation of existing copper/ aluminium conductors (HV/ LV) by way of providing and replacement of inter-layer insulation - per kg of winding. 1 kg
210 210 Rewinding without re-insulation of existing copper/ aluminium conductors (HV/ LV) - per kg of winding. 1 kg
211 211 Providing and fitting of Hot dipped galvanised MS nuts, bolts and washers of assorted sizes 1 kg
212 212 Providing and fitting of 6mm thick neoprene rubber gasket 1 no.
213 213 1600A/ 2000A 1 no.
214 214 Providing and fitting of Fixed arcing contact for ACB (L&T C-power)
215 215 800- 1600A 1 set of 03
216 216 2000A 1 set of 03
217 217 Providing and fitting of Moving arcing contact for ACB (L&T C-power)
218 218 800- 2000A 1 set of 09
219 219 Providing and fitting of Shunt release for ACB (L&T C-power) 1 no.
220 220 Providing and fitting of Under Voltage Release for ACB (L&T C-power) 1 no.
221 221 Providing and fitting of Earth Fault Release for ACB (L&T C-power) 1 no.
222 222 Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under:
223 223 upto 800 - 1250A 1 no.
224 224 1600 - 2000A 1 no.
225 225 Providing and fitting of CT for DN1 type L&T C-power ACB
226 226 800/ 1000A 1 no.
227 227 2000A 1 no.
228 228 Providing and fitting of main spring for 3-pole ACB (L&T C-power)
229 229 800- 1600A 1 no.
230 230 2000A 1 no.
231 231 Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) 1 no.
232 232 Providing and fitting of flush type analog moving iron AC meter as under:\n(Make: Rishabh/ AE/ C&S/ BCH)
233 233 48x48mm 500V voltmeter 1 no.
234 234 96x96mm 500V voltmeter 1 no.
235 235 144x144mm 500V voltmeter 1 no.
236 236 96x96mm ammeter (5A CT operated) 1 no.
237 237 Volt-Ammeter 500V, current ranges upto 125A (AE/ Rishabh/ L&T) 1 no.
238 238 Providing and fitting of flush type frequency meter with range 45-55Hz:\n(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) 1 no.
239 239 Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) 1 no.
240 240 Providing and fitting of 10A voltmeter selector switch with OFF\n(Make: L&T/ Rishabh/ AE/ Teknic) 1 no.
241 241 Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under:
242 242 100/5A or 150/5A - Class 1 - Burden 5VA 1 no.
243 243 200/5A - Class 1 - Burden 10VA 1 no.
244 244 400/5A - Class 1 - Burden 15VA 1 no.
245 245 600/5A - Class 1 - Burden 15VA 1 no.
246 246 800/5A - Class 1 - Burden 15VA 1 no.
247 247 1000/5A - Class 1 - Burden 15VA 1 no.
248 248 2000/5A - Class 1 - Burden 15VA 1 no.
249 249 Extra for 1A secondary upto 600/1A over corresponding rate 1 no.
250 250 Providing and fitting of analog VAC hour meter\n(Make: L&T or equivalent make)
251 251 Flush mounting type 1 no.
252 252 Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 1 no.
253 253 Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 1 no.
254 254 Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) 1 no.
255 255 Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make)
256 256 50V or less unbalance & 1 C/O DIN mounted 1 no.
257 257 50V or less unbalance & 1 C/O Panel wall mounted 1 no.
258 258 70V or less unbalance & 2 C/O DIN mounted 1 no.
259 259 Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) 1 no.
260 260 Providing of HRC fuses (2A - 32A) ratings 1 no.
261 261 Providing and fitting of Fuse holders for fuses upto 32A rating 1 no.
262 262 Providing and fixing uPVC panel trunking with cover
263 263 15x15mm 1 mtr
264 264 25x25mm 1 mtr
265 265 Providing and fitting of Terminal Block 100A - 3 way 1 no.
266 266 Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:
267 267 16 sq. mm 1 no.
268 268 25 sq. mm 1 no.
269 269 35 sq. mm 1 no.
270 270 50 sq. mm 1 no.
271 271 70 sq. mm 1 no.
272 272 95 sq. mm 1 no.
273 273 120 sq. mm 1 no.
274 274 150 sq. mm 1 no.
275 275 185 sq. mm 1 no.
276 276 225 sq. mm 1 no.
277 277 240 sq. mm 1 no.
278 278 300 sq. mm 1 no.
279 279 400 sq. mm 1 no.
280 280 500 sq. mm 1 no.
281 281 630 sq. mm 1 no.
282 282 Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:
283 283 16 sq. mm 1 no.
284 284 25 sq. mm 1 no.
285 285 35 sq. mm 1 no.
286 286 50 sq. mm 1 no.
287 287 70 sq. mm 1 no.
288 288 95 sq. mm 1 no.
289 289 120 sq. mm 1 no.
290 290 150 sq. mm 1 no.
291 291 185 sq. mm 1 no.
292 292 225 sq. mm 1 no.
293 293 240 sq. mm 1 no.
294 294 300 sq. mm 1 no.
295 295 400 sq. mm 1 no.
296 296 500 sq. mm 1 no.
297 297 630 sq. mm 1 no.
298 298 Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. 1 mtr
299 299 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 1 mtr
300 300 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess with GI saddles and allied fittings for connections etc. as required. 1 mtr
301 301 Credit value for scrap copper 1 kg
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail