Replacement Of 09 No . Age Old 16 . 66 Mva Single Phase Power Transformers By 03 No . 50 Mva 132/33 Kv Three Phase Power Transformers At 132/33 Kv Grid Station Pampore Replacement Of 09 No . Age Old 16 . 66 Mva Single Phase Power Transformers By 03 No . 50 Mva 132/33 Kv 3 Phase Power Transformers At 132/33 Kv Grid Station Pampore By Way Of Design , Manufacture , Supply , Unloading , Installation , Testing Commissioning , ( A ) Design , Manufacture , Supply , Packing & Forwarding , Transportation , Unloading , Delivery At Site Of Equipments And Materials . , Power Transformer , 50 Mva , 132/33 Kv Three Phase Power Transformers With Oltc , Scada Compatible Rtcc , Nifpes , Hv And Lv Connectors And Other Required Accessories And Fittings With Inbuilt Ncts . , Power And Control Cables Including Termination Of The Cables , 1100 V , Pvc Insulated , Pvc Sheathed , Frls , Galvanised Steel Wire/ Strip Armoured Stranded Copper Conductor Control Cable Complete As Per Specification . , 4 Core , 2 . 5 Sq Mm , 8 Core , 2 . 5 Sq Mm , 12 Core , 2 . 5 Sq Mm , Cable Glands , Ferrules & Lugs For All Above Cables Etc . , Ancillary Items , 500Mm2 Acsr Moose Conductor ( A ) Aluminium =54/3 . 53 Mm ( B ) Steel= 7/3 . 53 Mm Overall Diameter =31 . 77Mm Approx . Wt . =1998 Kg/Km Ultimate Strength = 159 . 60 Kn , Single Tension Fittings For Twin 500 Mm2 Acsr Shall Have Minimum Failing Load Of 100% Ultimate Strength Of Bundle Conductors With Compressive Type Tension Clamps Having Slipping Strength 95% Of Ultimate Strength Of Conductors . The Ball And Socket Designation Must Be 20Mm . Minimum Ultimate Strength ( Tensile Strength ) Shall Be 70 Kn . , Single Tension Fittings For Single 500Mm2 Acsr Shall Have Minimum Failing Load Of 100% Ultimate Strength Of Bundle Conductors With Compressive Type Tension Clamps Having Slipping Strength 95% Of Ultimate Strength Of Conductors . The Ball And Socket Designation Must Be 20Mm . Minimum Ultimate Strength ( Tensile Strength ) Shall Be 70 Kn . , T Clamps Twin 500Mm2 / Twin 500Mm2 , Made Of Alluminium Alloy And Shall Comply In All Respects With Is:5561-1970 ( Latest Edition ) , T Clamps Single 500Mm2 / Single 500Mm2 , Made Of Alluminium Alloy And Shall Comply In All Respects With Is:5561-1970 ( Latest Edition ) , Ct Clamps Suitable For Twin 500Mm Sq Acsr , Ct Clamps Suitable For Single 500Mm Sq Acsr , Disc Insulators 120 Kn , Ball & Socket Type , 145Mm Height And 280Mm Dia . Creepage Total 430 Mm And 260 Mm Protected . , Spacers For Twin 500Mm2 Must Be One-Piece Construction Of Aluminum Alloy Of An Approved Type Without Any Projection , Cuts , Abrasions Etc . Or Chattering Parts And Shall Conform To Is:10162 , Mandatory Spares , Set Of Spares For 132/33Kv Power Transformer , Ancilliary Items Etc . As Per Schedule Of Spares Given In Sbd . , ( B ) Handling , Storage , Preservation , Erection ( Except Civil Works ) , Dehydration , Testing & Commissioning Of Equipments And Material , Power Transformer , 50 Mva , 132/33 Kv Three Phase Power Transformers With Oltc , Scada Compatible Rtcc , Nifpes , Hv And Lv Connectors And Other Required Accessories And Fittings With Inbuilt Ncts . , Power And Control Cables , 1100 V , Pvc Insulated , Pvc Sheathed , Frls , Galvanised Steel Wire/ Strip Armoured Stranded Copper Conductor Control Cable Complete As Per Specification . , 4 Core , 25 Sq Mm , 8 Core , 2 . 5 Sq Mm , 12 Core , 2 . 5 Sq Mm , Cable Glands , Ferrules & Lugs For All Above Cables Etc . , Ancillary Items , 500Mm2 Acsr Moose Conductor ( A ) Aluminium =54/3 . 53 Mm ( B ) Steel= 7/3 . 53 Mm Overall Diameter =31 . 77Mm Approx . Wt . =1998 Kg/Km Ultimate Strength = 159 . 60 Kn , Single Tension Fittings For Twin 500 Mm2 Acsr Shall Have Minimum Failing Load Of 100% Ultimate Strength Of Bundle Conductors With Compressive Type Tension Clamps Having Slipping Strength 95% Of Ultimate Strength Of Conductors . The Ball And Socket Designation Must Be 20Mm . Minimum Ultimate Strength ( Tensile Strength ) Shall Be 70 Kn . , Single Tension Fittings For Single 500Mm2 Acsr Shall Have Minimum Failing Load Of 100% Ultimate Strength Of Bundle Conductors With Compressive Type Tension Clamps Having Slipping Strength 95% Of Ultimate Strength Of Conductors . The Ball And Socket Designation Must Be 20Mm . Minimum Ultimate Strength ( Tensile Strength ) Shall Be 70 Kn . , T Clamps Twin 500Mm2 / Twin 500Mm2 , Made Of Alluminium Alloy And Shall Comply In All Respects With Is:5561-1970 ( Latest Edition ) , T Clamps Single 500Mm2 / Single 500Mm2 , Made Of Alluminium Alloy And Shall Comply In All Respects With Is:5561-1970 ( Latest Edition ) , Ct Clamps Suitable For Twin 500Mm Sq Acsr , Ct Clamps Suitable For Single 500Mm Sq Acsr , Disc Insulators 120 Kn , Ball & Socket Type , 145Mm Height And 280Mm Dia . Creepage Total 430 Mm And 260 Mm Protected . , Spacers For Twin 500Mm2 Must Be One-Piece Construction Of Aluminum Alloy Of An Approved Type Without Any Projection , Cuts , Abrasions Etc . Or Chattering Parts And Shall Conform To Is:10162