| 1 | 0.5 | Schedule 'A' Part I - B/R portion | | | |
|---|
| 2 | 1 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed. | | 0.25 | Cum |
|---|
| 3 | 2 | Taking down chowkat or frames n exc 1.5 sqm each and re fixing in the same opening including all fixing arrangements with minor repairs without taking of shutters from the frame all as specified and as directed. | | 2 | Each |
|---|
| 4 | 3 | Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm and re fixing in the same opening each including all fixing arrangements with minor repairs without taking of shutters from the frame and removing to store all as specified and as directed. | | 2 | Each |
|---|
| 5 | 4 | Taking down shutter any type exc 1 sqm but not exc 2 sqm each and re fixing in the same opening each including all fixing arrangements with minor repairs without taking of shutters from the frame and removing to store all as specified and as directed. | | 13 | Each |
|---|
| 6 | 5 | Taking down PVC (SWR) pipes 75/110 mm bore from walls all as specified and as directed. | | 40 | RM |
|---|
| 7 | 6 | M&L for 50mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate, finishing the surface even and fair as in plinth protections and similar work all as specified and as directed. | | 50 | Sqm |
|---|
| 8 | 7 | M&L for taking down loose & damaged concrete/ cement plaster, from soffits of ceiling, floor/roof slabs,vertical surfaces of column beams slabs etc including exposing and removing rust from the reinforcement by rubbing with wire brush and removal of debris to a distance n exc 50m and deposited where directed all as specified and as directed. | | 180 | Sqm |
|---|
| 9 | 8 | M&L for preparation of surface by application of rust remover on exposed reinforcement using rust remover of approved make, apply passivator coat using zinc primer of approved make on reinforcement bars. Apply bond coat using \"Epoxy bonding agent\" on entire surface, when bond coat becomes tacky apply repair mortar (using universal polymerised repair mortars single pack like Pagel U40 or Microconcrete) in layers of 15mm and subsequently built up the required thickness (45mm) in subsequent layers of 15mm and finishing the final layer even and smooth as per manufacturers instruction and as directed weld the additonal steel bar when ever required. \nMake : M/s Pidilite Industrues Ltd or Equivalent in M/S Krishna Conchen Products/ STP Ltd.\nNotes: (i)Work to be done by authorised applicators only.\n(ii) TMT bar shall be measured and paid separately. | | 180 | Sqm |
|---|
| 10 | 9 | Supply only welded steel wire fabric weight n.exc 4 kg/sqm for structural member all as specified and as directed. | | 500 | Kg |
|---|
| 11 | 10 | M&L for TMT steel CRS bars 8mm dia, cut to length, bent to shape required and welded to existing reinforcement of any description and any position of RCC structure after binding with mild steel wire annealed n less than 0.9 mm dia as an additional bar complete all as specified and as directed. | | 50 | Kg |
|---|
| 12 | 11 | M&L for TMT steel CRS bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. | | 75 | Kg |
|---|
| 13 | 12 | Dismantling/taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface or RCC slab including removing the dismantled debris to a distance exc 200 m & n exc 250 m all as specified and as directed. | | 600 | Sqm |
|---|
| 14 | 13 | M&L for rendering 10mm average thickness on concrete surface over roof slabs in cement mortar 1:4 finished even and fair to receive roof treatment mixed with water proofing compound all as specified and as directed. | | 600 | Sqm |
|---|
| 15 | 14 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) and on primed surface by forced application complete all as specified and as directed.\nNote : Quoted rate should be inclusive of rate of primer/silver paint. | | 600 | Sqm |
|---|
| 16 | 15 | M & L for applying evenly a priming/tack coat of paving bitumen with bituminous primer at 0.4 kg per sqm over new/old plastered surface over roof top all as specified and as directed. | | 60 | 10Sqm |
|---|
| 17 | 16 | M & L for applying two coats of aluminium paint over roof surfaces of any description, over 10cm in width or girth,not otherwise described including cleaning of surface all as specified and as directed. | | 600 | Sqm |
|---|
| 18 | 17 | M&L in repair prelaminated particle board 18/19 mm, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work all as specified and as directed. | | 10 | Sqm |
|---|
| 19 | 18 | S&F aluminium powder coated barrel tower bolts of extruded section 100 mm long all as specified and as directed. | | 5 | Each |
|---|
| 20 | 19 | S&F extruded aluminium alloy, fabricated type handle, powder coated 150mm long all as specified and as directed. | | 10 | Each |
|---|
| 21 | 20 | S&F hasp & staple, safety type of aluminium, powder coated 125mm all as specified and as directed. | | 5 | Each |
|---|
| 22 | 21 | Supplying & fixing magnetic catchers in cupboard/ cabinet shutters including fixing with necessary screws etc complete all as specified and as directed.. | | 5 | Each |
|---|
| 23 | 22 | S&F in repairs curtain rails 19mm dia stainless steel with brackets stops rollers etc all as specified and as directed. | | 150 | RM |
|---|
| 24 | 23 | M&L for preparing old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. | | 120 | Sqm |
|---|
| 25 | 24 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and as directed. | | 145 | Sqm |
|---|
| 26 | 25 | S&F glazed ceramic tiles 300 x 200 x 7mm thick coloured on vertical surfaces such as dado skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. | | 100 | Sqm |
|---|
| 27 | 26 | M&L for rendering 10mm thick cement mortar 1:4 on fair faces of stone masonry wall surfaces, finished even and fair to receive glazed tiles all as specified and as directed. | | 120 | Sqm |
|---|
| 28 | 27 | M&L for vitrified ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42sqm, in floors etc. set and jointed neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. | | 275 | Sqm |
|---|
| 29 | 28 | M&L for vitrified ceramic tiles 10mm thick dark shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42sqm, in floors etc. set and jointed neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. | | 15 | Sqm |
|---|
| 30 | 29 | M&L for vitrified ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42sqm, in floors etc. set and jointed neat cement slurry and pointed in white or coloured cement to match in vertical surface all as specified and as directed. | | 20 | Sqm |
|---|
| 31 | 30 | S&F Non skid coloured ceramic tile 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. | | 25 | Sqm |
|---|
| 32 | 31 | M & L for providing adhesive for fixing floor tile all as specified and as directed. | | 290 | Sqm |
|---|
| 33 | 32 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and as directed. | | 20 | RM |
|---|
| 34 | 33 | M&L for screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor tiles all as specified and as directed. | | 25 | Sqm |
|---|
| 35 | 34 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, all as specified and as directed. | | 290 | Sqm |
|---|
| 36 | 35 | M&L for granite (of any type) tiles 18- 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in steps of stair case/floor all as specified and as directed. | | 10 | Sqm |
|---|
| 37 | 36 | M&L for granite (of any type) tiles 18-20 mm thick machine cut in dado/skirting/riser of steps, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in steps of stair case and vertical surface of wall all as specified and as directed. | | 4 | Sqm |
|---|
| 38 | 37 | Demolition of Stone slabs and tiles of any description or thickness in floors, laid and pointed in any mortar etc, all as specified and as directed. | | 1.4 | 10Sqm |
|---|
| 39 | 38 | M&L for 15 mm thick screed bed in cement mortar 1:4 for cooking flatform, for marble work etc, all as specified and as directed. | | 10 | Sqm |
|---|
| 40 | 39 | Taking down cement plaster of any description on brick or stone walls including racking out joint hacking for key, scrubbing down with water etc, all as specified and as directed. | | 350 | Sqm |
|---|
| 41 | 40 | M&L for rendering 15mm thick plaster in cement mortar 1:4 in two coats (10 mm thick backing coat + 5mm thick finishing coat) finished even and smooth without using extra cement including mixing of integral water proofing compound etc complete all as specified and as directed. \nNote : Integral water proofing compound shall be measured and paid separately | | 150 | Sqm |
|---|
| 42 | 41 | M&L for rendering 10 mm thick in cement mortar 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement all as specified and as directed. | | 100 | Sqm |
|---|
| 43 | 42 | M&L for preparing newly plastered surfaces of wall and applying two coats of Oil bound distemper over a coat of alkali resistant primer all as specified and as directed. | | 100 | Sqm |
|---|
| 44 | 43 | M & L for preparing newly plastered surface of walls and applying two coats of acrylic weather proof antifungal paint (Exterior grade) over a coat of primer complete all as specified and as directed. | | 150 | Sqm |
|---|
| 45 | 44 | M&L for rendering 5 mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified and as directed. | | 100 | Sqm |
|---|
| 46 | 45 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed. | | 100 | Sqm |
|---|
| 47 | 46 | Complete removal of old existing treatment and applying two coats of acrylic weather proof antifungal paint (Exterior grade) over a coat of primer complete all as specified and as directed. | | 800 | Sqm |
|---|
| 48 | 47 | M&L for complete removal of old/ existing treatment and applying two coats of distempering wall wih oil emulsion paint over a coat of 3 mm wall care putty all as specified and as directed. | | 250 | Sqm |
|---|
| 49 | 48 | M&L for complete removal of old/ existing treatment and applying three coats of white wash all as specified and as directed. | | 500 | Sqm |
|---|
| 50 | 49 | Supply only integral water proofing compound all as specified and as directed. | | 15 | Kg |
|---|
| 51 | 50 | M & L for filling the cracks by using the suitable chemical after cutting ‘V’ grooves 3 mm wide and 3 mm depth complete all as specified and as directed. | | 50 | RM |
|---|
| 52 | 51 | M&L for UPVC pipe, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls all as specified and as directed. | | 20 | RM |
|---|
| 53 | 52 | S&F UPVC (SWR) 110 mm bore single socketed, in any length with rubber ring joints, fixed to walls all as specified and as directed. | | 20 | RM |
|---|
| 54 | 53 | S &F UPVC (SWR) bends 75mm bore any radius dismantling pieces or tapers all as specified and as directed. | | 6 | Each |
|---|
| 55 | 54 | All as per item No.53 here in before,but 110mm bore | | 6 | Each |
|---|
| 56 | 55 | S&F UPVC (SWR) branch piece, single, (single Y) equal or unequal with access door, for 75mm bore pipes all as specified and as directed. | | 4 | Each |
|---|
| 57 | 56 | S&F UPVC (SWR) branch piece, single, (single Y) equal or unequal with access door, for 110mm bore pipes all as specified and as directed. | | 4 | Each |
|---|
| 58 | 57 | S&F 110mm dia UPVC (SWR) vent cowl all as specified and as directed. | | 3 | Each |
|---|
| 59 | 58 | S&F Nahani traps CL 75mm dia with grating including jointing to waste pipe fixed in cement concrete type B1 1:2:4 all as specified and as directed. | | 6 | Each |
|---|
| 60 | 59 | S&F in repairs looking mirror 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC bldg board or commercial ply wood and fixed to wooden plugs with CP brass screws and cup washers all as specified and as directed. | | 6 | Each |
|---|
| 61 | 60 | S&F UPVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement all as specified and as directed. | | 3 | Each |
|---|
| 62 | 61 | S&F stainless steel glass railing of height 0.9m and grade SS T-316 including all accessories with 12mm thick toughned glass and fitting to verandah, balconies etc all as per manufaturers instruction and as directed. | | 20 | RM |
|---|
| 63 | 62 | S & F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and as directed. | | 2 | Each |
|---|
| 64 | 63 | S&F in repair sheet glass good quality 8-10 mm thick and glazing with wooden beads/ply in any shape & size in each pane all as directed and fixed in any type of frame including all fixing arrangement all as specified and as directed. | | 5 | Sqm |
|---|
| 65 | 64 | S&F vitreous china coloured water closet European type with and including jet spray/faucet and seat cover fixed including fixing in repair with P trap all complete all as specified and as directed. | | 2 | Each |
|---|
| 66 | 65 | S&F in repairs vitreous china squatting pan orissa pattern, size 580x440 mm white with integral foot rest (excluding flushing cistern and flush pipe including provisionn of lime concrete bedding ,trap etc all as specified and as directed. | | 2 | Each |
|---|
| 67 | 66 | Treating and finishing the sunken portion of WC area n exc 1.2 Sqm each by sealing the edges of holes through which sanitary pipes are entering the sunken portion, using seal tape and grout the the gaps using a non-shrink cementitious grout (Dr. Fixit Pidicrete URP or equivalant of Focroc/STP/Krishnaconchem), providing 10mm thick rendering in cm 1:3 with and including water proofing compound. Apply first coat of WPC (cementitious product with acrylic emulsion polymer as binder using Dr. fixit Pidifin 2K of Pidilite Industries or equivalant of Focrock/Krishna Conchem) in the sunken portion and extended up to 15 on the wall above the FFL. Immediately cover all the angle fillets with a 150 mm wide strip of ope woven glass fiber mesh of 2mm x 2mm. Apply the second coat of WPC after the first coat dries completely and allow it to dry completely, providing necessary connection items suitable for WC, providing lime concretete complete all as per manufactures instruction and as directed. | | 2 | Each Job |
|---|
| 68 | 67 | All as per item 66 here in before, but for bath/lobby without any PVC connections, fittings, for area exceeding 1.2 Sqm and not exceeding 2 sqm each all as specified and as directed. | | 2 | Each Job |
|---|
| 69 | 68 | Taking up or down steel water tubing 15mm bore and connections, including cleaning for re-fixing all as specified and as directed. | | 25 | RM |
|---|
| 70 | 69 | All as per item No. 68 here in before, but 20mm bore pipe. | | 50 | RM |
|---|
| 71 | 70 | Supplying & laying CPVC water tubing outer dia 20mm, SDR-11 grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and as directed. | | 25 | RM |
|---|
| 72 | 71 | All as per item No. 70 here in before, but 25mm bore pipe. | | 50 | RM |
|---|
| 73 | 72 | S&F in repair 15 mm bore Bib tap cast copper alloy chromium plated long boby fancy type screwed for CPVC pipe all as specified and as directed. | | 6 | Each |
|---|
| 74 | 73 | Supply only pillar taps, fancy type cast copper alloy, with capstan heads chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for PVC pipe and fixed 15 mm bore all as specified and as directed. | | 6 | Each |
|---|
| 75 | 74 | M&L for waste fittings, brass,chromium plated for glazedware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed 32 mm all as specified and as directed. | | 6 | Each |
|---|
| 76 | 75 | S&F low density polythene (LDPE) pipes of pressure rating 6 Kg/Sqm of 32mm bore complete all as specified and as directed. | | 10 | RM |
|---|
| 77 | 76 | S&F in repairs vitreous china WHB, white, flat back, size 550mm x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets all as specified and as directed. | | 6 | Each |
|---|
| 78 | 77 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth in stone concret block or slab walls all as specified and as directed. | | 25 | RM |
|---|
| 79 | 78 | S & F in repairs stop valves CP long shank and cup (conseald type) , cast copper alloy, chromium plated screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed all as specified and as directed. | | 10 | Each |
|---|
| 80 | 79 | Supply and fix in repairs PVC low/high level flushing cistern, 10 Ltrs capacity including float valve, chain, PVC flush pipe all as specified and as directed. | | 6 | Each |
|---|
| 81 | 80 | S&F in repairs PVC connections, 600mm long with brass CP/PTMT nuts suitable for connecting 15mm bore pipes, superior quality all as specified and as directed. | | 12 | Each |
|---|
| 82 | 81 | S & F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Including of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and as directed. | | 6 | Each |
|---|
| 83 | 82 | S&F Vitreous china urinal partition white of size 310x700 mm all as specified and as directed. | | 2 | Each |
|---|
| 84 | 83 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required, reconnecting and refixing in position upto 1000 Ltr capacity complete all as specified and as directed. | | 6 | Each |
|---|
| 85 | 84 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation all as specified and as directed. | | 0.5 | Cum |
|---|
| 86 | 85 | M&L for precast cement concrete block masonary 1:3:6 type C-1, using 20mm graded stone aggregate with solid blocks exc 10cm in width and setting in mortar 1:6 complete all as specified and as directed. | | 2 | Cum |
|---|
| 87 | 86 | S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long all as specified and as directed. | | 10 | Each |
|---|
| 88 | 87 | M&L for PVC kitchen Cabinet(18 mm PVC both side prelaminated sheets of Rajshri Plastiwood)complete all as specified and as directed. | | 5 | Sqm |
|---|
| 89 | 88 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and as directed. | | 30 | Sqm |
|---|
| 90 | 89 | S&F aluminium (powder coated) snap grid frame work for false ceiling for size of grid 605 x 605 mm all as specified and as directed. | | 30 | Sqm |
|---|
| 91 | 90 | S&F 12mm thick mineral fibre boards as in false ceiling pannel made of aluminium grid all as specified and as directed.\nNote:- Aluminium grid shall be measured and paid separately. | | 30 | Sqm |
|---|
| 92 | 91 | M & L for PCC 25 mm Type B0, 1:2:4 using 12.5 mm graded stone aggregates as in floor or similar work all as specified and as directed. | | 50 | Sqm |
|---|
| 93 | 92 | M&L for painting to old steel surfaces over of 10 cm width or girth and applying two coats of synthetic enamel paint etc complete including preparation of surfaces all as specified and as directed. | | 75 | Sqm |
|---|
| 94 | 93 | S&F in repairs Pre-painted galvalume aluminium zinc coating GI based corrugate steel sheet 0.50 mm thick of an colour having Tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. | | 15 | Sqm |
|---|
| 95 | 94 | M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates all as specified and as directed. | | 50 | Kg |
|---|
| 96 | 95 | Dismantling iron or mild steel work of any description not otherwise provided for all as specified and as directed. | | 0.5 | Qtl |
|---|
| 97 | 96 | M&L for new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of anti corrossive paint over a coat of primer all as specified and as directed. | | 5 | Sqm |
|---|
| 98 | 97 | M&L for preparing surfaces and writing letters or fiqures (Block English/Hindi) upto 1 mtr height and width exceeding 30 cm & n.exc 45cm on Bldg or at any height by using good quality of paint & primer all all as specified and as directed. | | 20 | Each letter |
|---|
| 99 | 97.1 | Schedule 'A' Part II - E/M portion | | | |
|---|
| 100 | 98 | Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish all as specified and as directed. | | 175 | Point |
|---|
| 101 | 99 | M & L for point wiring complete with 1100 volt grade PVC insulated un-sheathed multi stranded 1.5 sqmm copper conductor cable confirming to IS : 694 drawn through and including rigid PVC casing –capping medium grade of size 25/20 mm, fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3 mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and as directed. | | | |
|---|
| 102 | 99.1 | (a) One light/fan point controlled by one switch | | 100 | Point |
|---|
| 103 | 99.2 | (b) One 3 pin socket outlet, 5 Amps. Independent, with cables 1.5 sqmm size | | 35 | Point |
|---|
| 104 | 99.3 | (c) One 3 pin socket, 5 Amps on the same board, with cables 1.5 sqmm size | | 30 | Point |
|---|
| 105 | 100 | All as per Item No 99 here in before, but complete with 1100 volt grade PVC insulated un-sheathed multi stranded wire with 2.5 sqmm copper cable through casing –capping of suitable size and one run of 2.5 sqmm copper cable as earth continuity conductor including connecting with earth dolly for 15 Amps socket outlet on independent board all as specified and as directed. | | 10 | Point |
|---|
| 106 | 101 | S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal all as specified and as directed. | | 65 | Each |
|---|
| 107 | 102 | S&F switch socket combination 5 in 1 pin, 5/16 Amp piano type,flush type all as specified and as directed. | | 10 | Each |
|---|
| 108 | 103 | S & F ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed. | | 100 | Each |
|---|
| 109 | 104 | S&F switch piano flush type single pole 5 Amps one way all as specified and as directed. | | 100 | Each |
|---|
| 110 | 105 | S&F deluxe stepped type electronic fan regulator deluxe flush 200 watt type on the phenolic laminated sheet etc complete all as specified and directed. | | 20 | Each |
|---|
| 111 | 106 | Removing and dismantling of any type tube light fitting and keep in safe custody for re use all as specified and directed. | | 120 | Each |
|---|
| 112 | 107 | Refixing of LED tube light fittings for wall/ceiling after completed building works with connected in original position complete and making electrical connection with copper cable all as specified and directed. | | 120 | Each |
|---|