| 1 | 1 | Earth work in excavation by manual / mechanical means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 mtr. in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, depth upto 1.5 mtr. including disposal of excavated earth lead upto as directed by Engineer-in-Charge, disposed earth is to be leveled and neatly dressed in ; All kind of soil. (Complete Job). | code1 | 162 | Cum |
|---|
| 2 | 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:5:10 (1 cement:5 coarse sand:10 graded stone aggregate 40 mm nominal size) (Crushed) (Complete Job) | code2 | 5 | Cum |
|---|
| 3 | 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:3:6(1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) (Crushed) (Complete Job) | code3 | 13 | Cum |
|---|
| 4 | 4 | Providing and laying 50mm thick damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size (Crushed) (Complete Job) | code4 | 6 | Sqm |
|---|
| 5 | 5 | Brick work with common burnt clay F.P.S (non-modualar) bricks of class designation 75 in foundation and plinth in cement mortar 1:6 (1 cement : coarse sand) Extra for brick work in superstructure above plinth level upto floor V level. (By mannual means) (Complete Job)(Complete Job) | code5 | 12 | Cum |
|---|
| 6 | 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutmen\"ts, posts ans sturts, etc. upto floor five level excluding cost of centring, shuttering, fmishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size) (Complete Job) | code6 | 11 | Cum |
|---|
| 7 | 7 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete.\nThermo-Mechanically treated bars. (Complete Job) | code7 | 1278 | Kg. |
|---|
| 8 | 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. (Complete Job) | code8 | 47 | Sqm |
|---|
| 9 | 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and centilevers. (Complete Job) | code9 | 8 | Sqm |
|---|
| 10 | 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roof, landings, balconies and access platform (Complete Job) | code10 | 57 | Sqm |
|---|
| 11 | 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls.\n under 20 cms wide (Complete Job) | code11 | 31 | Rmt. |
|---|
| 12 | 12 | Tile brick masonry work 5 cm thick with tile bricks of class designation 100 in cement mortar 1:3 (1 cement: 3 coarse sand) in superstructure. (Complete Job) | code12 | 16 | Sqm |
|---|
| 13 | 13 | 6 mm cement plaster to ceiling of mix 1 : 3 ( 1 cement : 3 fine sand) (Complete Job) | code13 | 61 | Sqm |
|---|
| 14 | 14 | 12 mm Cement plaster of mix:\n1:6(1 cement:6 fine sand). (Complete Job) | code14 | 136 | Sqm |
|---|
| 15 | 15 | Extra for plastering done on moulding cornices or architraves including neat finish to line and level: In one coat (Complete Job) | code15 | 6 | Sqm |
|---|
| 16 | 16 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber I neoprene gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed\nmechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminium (minimum thckness kg 396.35 of powder coated 50 microns) (Complete Job) | code16 | 253 | Kg. |
|---|
| 17 | 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber I neoprene gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed\nmechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns) (Complete Job) | code17 | 288 | Kg. |
|---|
| 18 | 18 | Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type-11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass I stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative\nlamination on both sides.(Complete Job) | code18 | 6 | Sqm |
|---|
| 19 | 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg I sqm) (Complete Job) | code19 | 11 | Sqm |
|---|
| 20 | 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 8 mm thickness\n(weight not less than 20.0 kg I sqm) (Complete Job) | code20 | 4 | Sqm |
|---|
| 21 | 21 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo em,possed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot\" and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-incharge. With Stainless Steel cover plate minimum 1.25 mm thickness. (Complete Job) | code21 | 2 | Each |
|---|
| 22 | 22 | Providing and fixing 100mm brass locks (best make of approved quality)for aluminium doors including necessary cutting and making good etc complete. (Complete Job) | code22 | 1 | Each |
|---|
| 23 | 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.\nSize of tiles 60 cm x 60 cm (Complete job) | code23 | 42 | Sqm |
|---|
| 24 | 24 | Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface. Water thinable Cement primer (Complete Job) | code24 | 197 | Sqm |
|---|
| 25 | 25 | Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade/ colour complete as per manufacturer's specifications Two or more coats on new work (Complete Job) | code25 | 93 | Sqm |
|---|
| 26 | 26 | Providing and applying white cement based putty off average thickness 2 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Complete job) | code26 | 93 | Sqm |
|---|
| 27 | 27 | Finishing walls with water proofing cement paint of required shade. New work (two or more coats) applied @ 3.84 Kg/10 Sqm, (Complete Job) | code27 | 104 | Sqm |
|---|
| 28 | 28 | Providing and fixing lSI marked aluminium butt hinges lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x63x3.2 mm (Complete Job) | code28 | 6 | Each |
|---|
| 29 | 29 | Providing and fixing lSI marked aluminium butt hinges lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 75x45x3.2 mm (Complete Job) | code29 | 35 | Each |
|---|
| 30 | 30 | Providing and fixing aluminium sliding door bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm (Complete Job) | code30 | 1 | Each |
|---|
| 31 | 31 | Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm (Complete Job) | code31 | 4 | Each |
|---|
| 32 | 32 | Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm (Complete Job) | code32 | 34 | Each |
|---|
| 33 | 33 | Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm (Complete Job) | code33 | 10 | Each |
|---|
| 34 | 34 | Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125mm (Complete Job) | code34 | 16 | Each |
|---|
| 35 | 35 | Providing and fixing aluminium hanging floor door stopper lSI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Twin rubber stopper (Complete Job) | code35 | 2 | Each |
|---|
| 36 | 36 | Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm (Complete Job) | code36 | 2 | Each |
|---|
| 37 | 37 | Providing and fiixng of powder coated aluminium gul mesh 2'-5\"x2'-5\" grid to window / ventilator shutters including complete fittings (Complete Job) | code37 | 147 | Sft. |
|---|
| 38 | 38 | Supply and fixing of 19mm thick ply wooden table 15'-0\" in length 21'-0\" wide and 2'-6\" in depth for 6 Nos. chairs (6 counters) with sunmica sheets on both sides of ply horizental / vertical supports including cost of fevicol, nails, sunmica of approved quality as well as 19mm ply anti termite water proof with 6 No. foot rests. (Complete Job) | code38 | 30 | Sft. |
|---|
| 39 | 39 | Supply of official chairs for 6 No. counter of approved make and size (movable) as per directions of engineer-in-charge (Complete Job) | code39 | 6 | Each |
|---|
| 40 | 40 | Supply and fiixng of stainless steel benches three seater for public use in (waiting Hall) (Complete Job) | code40 | 6 | Each |
|---|
| 41 | 41 | Supply and fixing of galvanized wire gauge to aluminium window shutters including U-shape beeding and steel stairs (Complete Job) | code41 | 10 | Sqm |
|---|
| 42 | 42 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead. 1:3:6 or richer mix (Complete Job) | code42 | 14 | Cum |
|---|
| 43 | 43 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : In cement mortar (Complete Job) | code43 | 5 | Cum |
|---|
| 44 | 44 | Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 metres lead (Complete Job) | code44 | 2300 | Kg. |
|---|
| 45 | 45 | Disposal of mulba including loading unloading from site of work to dumping site (Complete Job) | code45 | 100 | Cum |
|---|